• Title/Summary/Keyword: accuracy indicator

Search Result 279, Processing Time 0.028 seconds

New accuracy indicator to quantify the true and false modes for eigensystem realization algorithm

  • Wang, Shuqing;Liu, Fushun
    • Structural Engineering and Mechanics
    • /
    • v.34 no.5
    • /
    • pp.625-634
    • /
    • 2010
  • The objective of this paper is to apply a new proposed accuracy indicator to quantify the true and false modes for Eigensystem Realization Algorithm using output-based responses. First, a discrete mass-spring system and a simply supported continuous beam were modelled using finite element method. Then responses are simulated under random excitation. Natural Excitation Technique using only response measurements is applied to compute the impulse responses. Eigensystem Realization Algorithm is employed to identify the modal parameters on the simulated responses. A new accuracy indicator, Normalized Occurrence Number-NON, is developed to quantitatively partition the realized modes into true and false modes so that the false portions can be disregarded. Numerical simulation demonstrates that the new accuracy indicator can determine the true system modes accurately.

A study on sensitivity of representativeness indicator in survey sampling (표본 추출법에서 R-지수의 민감도에 관한 연구)

  • Lee, Yujin;Shin, Key-Il
    • The Korean Journal of Applied Statistics
    • /
    • v.30 no.1
    • /
    • pp.69-82
    • /
    • 2017
  • R-indicator (representativeness indicator) is used to check the representativeness of samples when non-responses occur. The representativeness is related with the accuracy of parameter estimator and the accuracy is related with bias of the estimator. Hence, unbiased estimator generates high accuracy. Therefore, high value of R-indicator guarantees the accuracy of parameter estimation with a small bias. R-indicator is calculated through propensity scores obtained by logit or probit modeling. In this paper we investigate the degree of relation between R-indicator and different non-response rates in strata using simulation studies. We also analyze a modified Korea Economic Census data for real data analysis.

The Design, Fabrication, and Characteristic Experiment for Control Rod Position Indicator Using Reed Switch in System-Integrated Modular Advanced Reactor (리드스위치를 이용한 일체형원자로용 제어봉 위치지시기 설계 제작 및 특성해석)

  • Hur, Hyung;Kim, Jong-In;Kim, Kern-Jung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.8
    • /
    • pp.452-461
    • /
    • 2003
  • The reliability and accuracy of the information on control rod position are very important to the reactor safety and the design of the core protection system. A survey on the RSPT(Reed Switch Position Transmitter) type control rod position indicator system and its actual implementation in the existing nuclear power plants in Korea was performed first. The control rod position indicator having the high performance for SMART was developed on the basis of RSPT technology identified through the survey. The arrangement of permanent magnet and reed switches is the most important procedure in the design of control rod position indicator. The hysteresis of reed switches is one of the important factors in a repeat accuracy of control rod position indicator as well. This paper investigates efficiency of the magnetic flux concentrator and the hysteresis using FEM and verified differences in physicals characteristics by comparing the results of FEM and those of the experiment. As a result, it is shown that the characteristics of prototype control rod position indicator have a good agreement with the results of FEM.

Experimental and Field Investigations for the Accuracy of the Frost Depth Indicator with Methylene Blue Solution (실내실험과 현장실험을 통한 Methylene Blue 동결깊이 측정장치 신뢰성 검토에 관한 연구)

  • Kim, Hak Seung;Lee, Jangguen;Kim, Young Seok;Kang, Jae-Mo;Hong, Seung-Seo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.3
    • /
    • pp.75-79
    • /
    • 2013
  • The frost depth is one of important factors in the design of structures such as roadways, buried pipeline, and foundations. A frost indicator with methylene blue solution has several advantages with respect to installation cost, maintenance, and simple measurement. However, as a geotechnical engineering aspect, the accuracy of the frost indicator has not been proved yet. This paper presents experimental and field investigations of the accuracy of the frost indicator and contour maps of maximum frost depth. The contour maps of maximum frost depth can be applied to design geo-infrastructure in South Korea.

Correlation between the Position Accuracy of the Network RTK Rover and Quality Indicator of Various Performance Analysis Method (Network RTK 품질 분석 방법론별 성능 지표와 사용자 항법 정확도의 상관성)

  • Lim, Cheol-soon;Park, Byung-woon;Heo, Moon-beom
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.375-383
    • /
    • 2018
  • In order to apply the Network RTK (real time kinematics) technology, which has been used for positioning of stationary points, to the navigation of vehicles, its infrastructure should provide correction data with a quality indicator that can show the expected accuracy in real time. In this paper, we analyzed various indicator generation algorithms such as I95 (ionospheric index 95) / G95 (geodetic index 95), SBI (semivariance based index) and RIU (residual interpolation uncertainty). We also applied them to the raw observables from the reference stations of National Geographic Information Institute and VRS (virtual reference station) users, and then examined its feasibility to be used as a real-time performance index of the Network RTK rover. 24 hour data analysis shows that the RIU index, which can represent the non-linearty of the correction, has the strongest correlation with the Network RTK rover accuracy. Therefore, RIU index is expected to be used as a real-time performance index of the Network RTK rover.

Determination of In-focus Criteria In Image Processing Method for Particle Size Measurement (입경측정을 위한 영상처리기법에서 입자 초점면 존재 판단 기준의 설정)

  • Koh, Kwang Uoong;Kim, Joo Youn;Lee, Sang Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.3
    • /
    • pp.398-407
    • /
    • 1999
  • In the present image processing technique, the concept of the gradient indicator(GI) has been introduced to find out the depth-of-field in sizing large particles ranging from $30{\mu}m$ to $30{\mu}m$ where using of the concept of the normalized contrast value(VC) is not appropriate. The gradient indicator is defined as the ratio of the local value to the maximum possible value of the gray-level gradient in an image frame. The gradient indicator decreases with the increases of the particle size and the distance from the exact focal plane. A particle is considered to be in focus when the value of the gradient indicator at its image boundary stays above a critical value. This critical gradient indicator($GI_{critical}$) is defined as the maximum gradient indicator($GI_{max}$) subtracted by a constant ${\Delta}GI$ which is to account for the particle-size effect. In the present ca.so, the value of ${\Delta}GI$ was set to 0.28 to keep the standard deviation of the measured particles mostly within 0.1. It was also confirmed that, to find the depth-of-field for small particles(${\leq}30{\mu}m$) with the same measurement accuracy, tho concept of the critical normalized contrast($VC_{critical}$) is applicable with 85% of the maximum normalized contrast value($VC_{max}$). Finally, the depth-of-field was checked for the size range between $10{\mu}m$ and $300{\mu}m$ when the both in-focus criteria ($GI_{critical}$ and $VC_{critical}$) were adopted. The change of the depth-of-field with the particle size shows good linearity in both the VC-applicable and the GI-applicable ranges with a reasonable accuracy.

Development of Position Indicator for System-Integrated Reactor SMART (일체형원자로 SMART의 제어봉 위치지시기 개발)

  • Yu, Je-Yong;Kim, Ji-Ho;Huh, Hyung;Kim, Jong-In;Chang, Moon-Hee
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.921-926
    • /
    • 2001
  • The reliability and accuracy of the information on control rod position are very important to the reactor safety and the design of the core protection system. In this study, a thorough investigation on the RSPT(Reed Switch Position Transmitter) type control rod position indication system and its actual implementation in the exiting nuclear power plants in Korea was performed first. A design of the control rod position indication system using reed switch for the CEDM on the system-integrated reactor SMART was developed based on the position indicator technology identified through the investigation. The feasibility of the design was evaluated by test of manufactured control rod position indicator using reed switch for SMART.

  • PDF

Long-Term Load Forecasting in Metropolitan Area Considering Economic Indicator (대도시 지역의 경제지표를 고려한 장기전력 부하예측 기법)

  • Choe, Sang-Bong;Kim, Dae-Gyeong;Jeong, Seong-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.8
    • /
    • pp.380-389
    • /
    • 2000
  • This paper presents a method for the regional long-term load forecasting in metropolitan area considering econimic indicator with the assumption that energy demands propoprtionally increases under the economic indicators. For the accurate load forecasting, it is very important to scrutinize the correlation among the regional electric power demands, economic indicator and other characteristics because load forecasting results may vary depending on many different factors such as electric power demands, gross products, social trend and so on. Three steps for the regional long-term load forecasting are microscopically and macroscopically used for the regional long -term load forecasting in order to increase the accuracy and practicality of the results.

  • PDF

Design and Manufacture of Position Indicator for Cryogenic Valve (극저온 밸브용 위치지시기 설계 및 제작)

  • Koh, Hyeon-Seok;Han, Sang-Yeop
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.850-853
    • /
    • 2011
  • The position indicator for cryogenic valves used in space launch vehicle should have high reliability and accuracy. Because the valves operate in cryogenic environment, the position indicator has to measure the valve status independently of the environmental factor, such as moisture and external contamination. We have developed the position indicator using a permanent magnet and reed switches to satisfy these requirements. We analyzed the characteristics of a permanent magnet and reed switches, then selected the appropriate components for cryogenic temperature. The shape and position of components were also considered to measure the open/close information of valve accurately Finally, the position indicator was applied to the valve prototype model, and verified the feasibility of design parameters.

  • PDF

Comparative Study of Contrast-Enhanced Ultrasound Qualitative and Quantitative Analysis for Identifying Benign and Malignant Breast Tumor Lumps

  • Liu, Jian;Gao, Yun-Hua;Li, Ding-Dong;Gao, Yan-Chun;Hou, Ling-Mi;Xie, Ting
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.19
    • /
    • pp.8149-8153
    • /
    • 2014
  • Background: To compare the value of contrast-enhanced ultrasound (CEUS) qualitative and quantitative analysis in the identification of breast tumor lumps. Materials and Methods: Qualitative and quantitative indicators of CEUS for 73 cases of breast tumor lumps were retrospectively analyzed by univariate and multivariate approaches. Logistic regression was applied and ROC curves were drawn for evaluation and comparison. Results: The CEUS qualitative indicator-generated regression equation contained three indicators, namely enhanced homogeneity, diameter line expansion and peak intensity grading, which demonstrated prediction accuracy for benign and malignant breast tumor lumps of 91.8%; the quantitative indicator-generated regression equation only contained one indicator, namely the relative peak intensity, and its prediction accuracy was 61.5%. The corresponding areas under the ROC curve for qualitative and quantitative analyses were 91.3% and 75.7%, respectively, which exhibited a statistically significant difference by the Z test (P<0.05). Conclusions: The ability of CEUS qualitative analysis to identify breast tumor lumps is better than with quantitative analysis.