• Title/Summary/Keyword: accumulator

Search Result 245, Processing Time 0.025 seconds

Effects of Accumulator Heat Exchanger on the Performance of a Refrigeration System (열교환기 내장형 어큐뮬레이터가 냉동시스템의 성능에 미치는 영향에 관한 연구)

  • Kang Hoon;Choi Kwang-Min;Park Cha-Sik;Kim Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.5
    • /
    • pp.418-425
    • /
    • 2006
  • An AHX (Accumulator Heat exchanger) consists of a commercial accumulator and an inner heat exchanger located inside of the accumulator. The AHX is used in multi air-conditioners to assure that liquid-phase refrigerant enters into the expansion device. This purpose is achieved by heat transfer between the refrigerant leaving the evaporator and the refrigerant leaving the condenser. In this study, the effects of AHX on the performance of a refrigeration system using R-22 were measured and the test results were analyzed. The operating characteristics of the refrigeration system with the AHX are considerably different from those without the AHX. Therefore, it is required to determine optimum refrigerant charge and optimum operating conditions when the AHX is used in the refrigeration system having a constant flow-area expansion device such as capillary tube.

Dynamic Response of Hydraulic Transmission Lines with an Accumulator (축압기를 갖는 유압관로의 동특성에 관한 연구)

  • Lee, Ill-Yeong;Hong, Bong-Ki
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.17 no.1
    • /
    • pp.29-34
    • /
    • 1981
  • More recently, unsteady flow in small-diameter pipes plays a major role in liquid propellantrocket systems, hydraulic and pneumatic control system, and elsewhere. And it has shown that line dynamics can have a marked effect on the hydraulic system characteristics. In this paper, transfer function of hydraulic lines with an accumulator and an outlet orifice is' developed and compared with experimental data from frequency response tests at various airvolume(V.) and the location of accumulator(ld1t), so that their performance may be correctly and easily predicted and the design of the systems incorporating them improved. The obtained results are as follows: 1. The dynamic response of hydraulic lines may be analyzed more accurately by use of the viscous term(22) in unsteady laminar flow. 2. There was good agreement between the theoretical and experimental results of this investigation, and hydraulic systems with liines included an accumulator can be analyzed more accurately by use of the pressure transfer function given by eq. (16). 3. For the mitigation of surge in hydraulic lines, it is more effective that the location ofaccumulator is close to the pipe outlet side. 4. According to the gas volume of accumulator is increased(the sealing pressure is close tomean line pressure), the damping effect of pressure wave is improved.

  • PDF

The Experimental Study on Uniform Distribution of Oil at the Air Conditioning System using Two Compressors (두 대의 압축기를 적용한 에어컨의 오일분배 특성에 관한 실험적 연구)

  • 김철민;황윤제;정백영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.103-108
    • /
    • 2003
  • The common accumulator was designed for solving the maldistribution problem of oil at the air conditioning system with two compressors. The oil level inside two compressors was visualized by using a common accumulator on the various operating conditions. As a result of the visualization, oil distribution inside two compressors was achieved appropriately according to the capacity of each compressor. Uniform distribution of oil was also accomplished at on and off operation condition.

Experimental Reduction of the Noise Radiated by Rotary Compressor (로터리 컴프레서 방사소음의 실험적 저감)

  • 박상영;이상현;이수일;이장무
    • Journal of KSNVE
    • /
    • v.9 no.1
    • /
    • pp.189-195
    • /
    • 1999
  • The noise radiated by the rotary compressor for a room air-conditioner was investigated experimentally. Noise characteristics and structural eigen modes of the compressor were identified through sound tests and modal tests each other. From these tests. we found that the accumulator has a big contribution to the noise radiation. So, various structural modifications for the accumulator were performed and these modification methods were found efficient to the noise reduction from verification tests.

  • PDF

Development of Tube End-forming Process using Roll Die (롤다이를 이용한 튜브 축관공정 개발)

  • Kim, Yeong-Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.4
    • /
    • pp.121-126
    • /
    • 2011
  • An accumulator placed on the refrigerant cycle pipe lines is a part to relax fluctuations of pressure within the pipe lines and stabilize refrigerants flowed into pipe. The accumulator has been mainly manufactured by the process of tube spinning using CNC(Computer Numerical Control) lathe. However, this process has the defects which are low productivity per hour and high cost. For that reason, tube end-forming using roll die is actively being developed, recently. The purpose of this study is to develope the tube end-forming process using roll die in order to manufacture the accumulator for the refrigeration pipe lines. First, the process design of tube end-forming was performed based on specification of product, and then was verified with FE analysis. Also, the effects of friction coefficient and revolution speed of roll die on forming load were investigated. The analytical results were applied in the final process design of tube end-forming. Finally, tube end-forming test was carried out to verify the validity of the FE analysis and the process design.

Development of a Simulator of Vehicle Equipped with Hydrostatic Transmission and Hydraulic Accumulator Type-Braking Energy Regeneration System (유압 축압기식 제동에너지 회생시스템을 장착한 정유압구동식 차량의 모의시험기 개발)

  • 이성래
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.5
    • /
    • pp.119-126
    • /
    • 2003
  • The simulator of a vehicle equipped with hydrostatic transmission and hydraulic accumulator type-braking energy regeneration system is developed using a PC. The simulator receives the accelerator pedal angle and the brake pedal angle generated by the operator using the keyboard, updates the state variables of the energy regeneration system responding to the input signals, and draws the moving pictures of the accumulator piston, pump plate angle and pump/motor plate angle every drawing time on the PC monitor. Also, the operator can observe the accel pedal angle, brake pedal angle, pressures of accumulators, vehicle speed, hydraulic torque, engine torque and air brake torque representing the operation of braking energy regeneration system through the PC monitor every drawing time. The simulator can be a very useful tool to design and improve the braking energy regeneration system.

Adder-and-Accumulator ($A^{2}C$) for Pipelined $\Delta\Sigma$ Modulator (Pipelined $\Delta\Sigma$ 변조기에 적합한 Adder-and-Accumulator ($A^{2}C$))

  • 이주애;김선호;김대정;민경식;김동명
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.967-970
    • /
    • 2003
  • A new adder-and-accumulator (A$^2$C) adapted to pipelined Δ$\Sigma$ modulators is proposed in this paper. With the viewpoint of area consumption, registers are removed in the existing pipelined Δ$\Sigma$ modulator, and then adder and accumulator are merged. In order to optimize area consumption, speed and power consumption, dynamic carry look-ahead adder (CLA) is adopted in $A^2$C. Moreover, a guideline for the transistor sizing in CLA with regard to the minimization of the energy-delay-area product (EDAP) is proposed[1]. The proposed $A^2$C has been verified by HSPICE simulations.

  • PDF

A Study on Capacity Selection of Accumulator by Mathematical Model in Hydraulic Regenerative Brake System (수학적 모델에 의한 유압 재생 브레이크 시스템의 축압기 용량 선정에 관한 연구)

  • 이재구;함영복;김도태;김성동
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.2
    • /
    • pp.48-55
    • /
    • 2001
  • An accumulator in hydraulic systems stores kinetic energy during braking action, and then that control hasty surge pres-sure. This study suggests a method to select the capacity of accumulator to control surge pressure to a desired degree. The selection method is based upon a trial and error approach and computer simulation. A mathematical dynamic model of the system was derived and the parameters in the model were identified from experimental data. A series of computer simulation were done for the brake action. The results of the simulation work were compared with those of experiments. These results of the computer simular-tion and experiments show that the proposed method can be applied effectively to control the surge pressure of the hydraulic regenerative brake systems.

  • PDF

Attenuation of Pressure Fluctuations in Oil Hydraulic Pipeline with Bellows Type Accumulator (벨로스형 어큐뮬레이터의 압력 맥동 감쇠 특성)

  • Lee, I.Y.;Jung, Y.G.;Lee, S.J.
    • Journal of Power System Engineering
    • /
    • v.5 no.4
    • /
    • pp.31-37
    • /
    • 2001
  • Pressure propagation and attenuation characteristics in a hydraulic pipeline with a bellows type accumulator was investigated by theoretical analyses and experiments. In the first stage of the study, equations to evaluate the amount of oil volume charged into the bellows together with nitrogen gas were proposed. In the next stage, the authors suggested a mathematical model based on transfer matrix method to describe the dynamic characteristics of the pipe element with a metal bellows type accumulator. Through comparisons and considerations of the experimental and the numerical data shown in frequency domain, the validity of the mathematical model was confirmed.

  • PDF

Development of a Simulator of Vehicle Equipped with Mechanical Transmission and Hydraulic Accumulator Type-Braking Energy Regeneration System (유압 축압기식 제동에너지 희생시스템을 장착한 기계식 변속기 차량의 모의시험기 개발)

  • 이성래
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.5
    • /
    • pp.180-186
    • /
    • 2004
  • The simulator of a vehicle equipped with mechanical transmission and hydraulic accumulator type-braking energy regeneration system is developed using a PC. The simulator receives the shift lever position, the accelerator pedal angle and the brake pedal angle generated by the operator using the keyboard, updates the state variables of the energy regeneration system responding to the input signals, and draws the moving pictures of the accumulator piston and pump/motor plate angle every drawing time on the PC monitor. Also, the operator can observe the shift lever position, the accel pedal angle, brake pedal angle, pressures of accumulators, vehicle speed, hydraulic torque, engine torque and air brake torque representing the operation of braking energy regeneration system through the PC monitor every drawing time. The simulator can be a very useful tool to design and improve the braking energy regeneration system.