• Title/Summary/Keyword: accident distribution test

Search Result 64, Processing Time 0.032 seconds

A Study on the Confirmation of non-flammabikity of the Cast Resin Mold Transformer in Subway Substation (지하철 변전실용 진공주형형 몰드변압기의 난연성 확인에 관한 연구)

  • 정용기;장성규;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.99-107
    • /
    • 1998
  • This dissertationhas confirmed the non-flam mability of cast mold transformer that is increasingly used lately. As a research progress, the investigation has been performed on the installation status and each line of the subway system which have the most mold transformer accidents, and the impediment status of the transformer for rectifier and the high-voltage distribution transformer per each manufacturer. Then, a high voltage mold of the actual mold transformer has been installed in the horiwntal heating furnace and the heat has been applied by the standard heating temperature curve of KSF 2257(Fireproof testing meth od of the construction structures: 1993). Accordingly, the combustibility of the mold transformer based on the test results has been found that 78 minutes has been required for the complete burning per the KSF 2257 combustion test curve and that, after stopping the heat application of the horizontal furnace after ignition, the flame progress has not been made but shown as the self-extinguishing characteristics when the flame progress has been checked. Thus, the non-flammability and self-extinguishability of the mold transformer have been confirmed. The result of this dissertation has indicated that the accident involving mold transformer has been progressed and expanded by the dielectric breakdown or void due to the crack in the mold rather than a fire accident caused by a short-circuit or an overload.r an overload.

  • PDF

The Study Image Aquisition System for Radiation Source Using the Stereo Gamma-ray Detector (스테레오 감마선 탐지장치를 이용한 감마선원 분포측정 시스템에 관한 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Lee, Seung-Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.197-203
    • /
    • 2015
  • Nuclear power plant has increased continuously for power production in all over the world and the interest about nuclear accident and the dismantling of aging nuclear power plant has been a growing. The leaked radioactive source that is generated by radiation accidents must detect and remove to minimized the damage as soon as possible. Gamma-ray detection system that have been developed until now cannot provide the precise position of radioactive sources because they detect and imaging the position of radiation sources in just two dimensions. In this paper, stereo gamma ray detection system has developed and the algorithm for calculation of the distance has implemented to be able to measure the distribution of the leakage gamma ray source for the system. Stereo camera calibration for distance detection was conducted with the correction pattern and LED light and we carried out performance test of the system for the LED light source and a gamma ray source. In both experiments the results of the performance test, it was confirmed to have a 5% error. The results of this paper is used as a material for the development of gamma-ray imaging device.

Study of The Area of Nursing Need by the Family Developmental Stage (가족발달단계에 따른 간호요구영역에 관한 연구)

  • 최부옥
    • Journal of Korean Academy of Nursing
    • /
    • v.7 no.2
    • /
    • pp.43-59
    • /
    • 1977
  • The Community Health Service considers the family as a service unit and places the emphasis of its service on the health problems and the nursing needs of the family rather than the individual. From the conceptual point of view that tile community health service is both health maintenance and health promotion of the family, the community health nurse should have a knowledge of the growth and development of the family and be responsible for the comprehensive support of normal family development. The community health nurse often is in a position to make a real contribution to normal family development. In order to investigate the relationship between the areas of nursing need and family development, the following objectives were established 1. To discover the general characteristics of the study population by the stage of family development. 2. To discover specific nursing needs in relation to the family developmental stage, and to determine the intensity of the nursing needs and the ability of the family to cope with these needs. 3. To discover overall family health nursing problems in relation to the family developmental stage and determine the intensity of the nursing need and the problem solving ability of family. Definitions : The family developmental stages as classified by Dually were used stage 1. Married couples(without children) stage 2. Childbearing Families (oldest child birth to 30 months of age) stage 3. Families with preschool children (oldest child 2½-to 6 years) stage 4. Families with schoolchildren (oldest child 6 to 13 years). stage 5. Families with teenagers (oldest child 13 to 20 years) stage 6. Families as launching centers (first child gone to last child′s leaving home). stage 7. Middle- aged parents (empty nest to retirement) stage 8. Aging family member (retirement to death of both spouses) The areas of nursing need were defined as those used in the study, "A Comprehensive Study about Health and Nursing Need and a Social Diagram of the Community", by tile Nursing research Institute and Center for population. and Family Planning, July 1974. The study population defiled and selected were 260 nuclear families ill two myron of Kang Hwa Island. Percent, mean value and F- test were utilized in tile statistical analysis of the study result. Findings : 1. General characteristics of the study population by tile family developmental stage ; 1)The study population was distributed by the family developmental stage as follows : stage 1 : 3 families stage 2 : 13 families stage 3 : 24 families stage 4 : 41 families stage 5 : 50 families stage 6 : 106 families stage 7 : 13 families stage 8 : 10 families 2) Most families had 4 or 5 members except for those in stage, 1, 7, and 8. 3) The parents′ present age was older in the higher developmental stage and their age at marriage was also younger in the higher developmental stages. 4) The educational level of parents was primarily less than elementary school irrespective of the developmental stage. 5) More than half of parents′ occupations were listed as laborers irrespective of the developmental stage, 6) More than half of the parents were atheists irrespective of the developmental stage. 7) The higher the developmental stage(from stage 2 to stage 6 ), the wider the distribution of children′s ages. 8) More than half of the families were of middle or lower socio-economic level. 2. Problems in specific areas of nursing need by family developmental stage, the intensity of nursing need and the problem solving ability of the family : 1) As a whole, many problems, irrespective of the developmental stage, occurred in tile areas of Housing and Sanitation, Eating Patterns, Housekeeping, Preventive Measures and Dental care. Problems occurring ill particular stages included the following ; stage 1 : Prevention of Accident stage 2 : Preventive Vaccination, Family Planning. stage 3 : Preventive Vaccination, Maternal Health, Family Planning, Health of Infant and Preschooler. stage 4, 5 : Preventive Vaccination, Family Planning, Health of School Children. stage 6 : Preventive Vaccination, Health of School Children. 2) The intensity of the nursing need in the area of Acute and Chronic Diseases was generally of moderate degree or above irrespective of the developmental stages except for stage 1. Other areas of need listed as moderate or above were found in the following stages: stage 1 : Maternal Health stage 3 . Horsing and Sanitation, Prevention of Accident. stage 4 . Housing and Sanitation. stage 5 : Housing and Sanitation, Diagnostic and Medical Care. stage 6 : Diagnostic and Medical care stage 7 : Diagnostic and Medical Care, Housekeeping. stage 8 : Housing and Sanitation, Prevention of Accident, Diagnostic and Medical Care, Dental Care, Eating Patterns, Housekeeping. 3) Areas of need with moderate problem solving ability or less were as follows : stage 1 : Diagnostic and Medical Care, Maternal Health. stage 2 : Prevention of Accident, Acute and Chronic Disease, Dental Care. stage 3 : Housing and Sanitation, Acute and Chronic Disease, Diagnostic and Medical Care, Preventive Measure, Dental Care, Maternal Health, Health of Infant and preschooler, Eating Patterns. stage 4 : Housing and Sanitation, Prevention of Accident, Diagnostic and Medical Care, Preventive Measure, Dental Care, Maternal Health, Health of New Born, Health of Infant and Preschooler, Health of school Children, Eating Patterns, Housekeeping. stage 5 . Housing and Sanitation, Prevention of Accident, Acute and Chronic Disease, Diagnostic and Medical Care, Preventive Measure, Dental Care, Preventive Vaccination, Maternal Health, Eating Patterns. stage 7, 8 : Housing and Sanitation, Prevention of Accident, Acute and Chronic Disease, Diagnostic and Medical Care, Preventive Measures, Dental Care, Preventive Vaccination, Eating Patterns , Housekeeping. Problem occurrence, the degree of nursing need and the degree of problem solving ability 1 nursing need areas for the family as a whole were as follows : 1) The higher the stages(except stage 1 ), the lower the rate of problem occurrence. 2) The higher the stage becomes, the lower the intensity of the nursing need becomes. 3) The higher the stages (except stages 7 and 8), the higher. the problem solving ability. Conclusions ; 1) When the nursing care plan for the family is drawn up, depending upon the stage of family development, higher priority should be give to nursing need areas ① at which problems were shown to occur ② where the nursing need is shown to be above moderate degree and ③ where the problem solving ability was shown to be of moderate degree. 2) The priority of the nursing service should be Placed ① not on those families in the high developmental stage but on those families in the low developmental stage ② and on those areas of need shown in stages 7 and 8 where the degree nursing need was high and the ability to cope low.

  • PDF

A Study on Improving the Tractor ROPS and Seatbelt use of Korean Farmers (농용트랙터 보호구조물 사용실태 및 좌석벨트 편이성 평가에 관한 연구)

  • Kim, Hyuck-Joo;Kim, Kwan-Woo;Choi, Sun;Kim, Jong-Sun;Kim, Yu-Yong;Kim, Jin-Oh;Kim, Hak-Kyu;Kwon, Soon-Hong
    • Journal of Biosystems Engineering
    • /
    • v.35 no.5
    • /
    • pp.294-301
    • /
    • 2010
  • This study was performed to improve the utilization of the ROPS and seatbelt of tractors in Korea. We surveyed the ROPS and seatbelt use and the tractor related accidents through the personal interviews for 141 farmers. And comfort test for tractor seatbelts is done for 4 different subjects by measuring the body pressure distribution. The survey showed that 79.3% of the tractor accidents was overturning accidents. And, in case the tractor has ROPS and seatbelt, there was no serious injuries. With this results, we could confirm that ROPS and seatbelt is very effective devices for protecting drivers in overturning accidents. But, in case farmers didn't wear seatbelt, there was some fatal injuries. This shows the importance of the seatbelt use in working and driving tractors. Therefore, we tested the comfort of the tractor seatbelt for 4 different subjects operating the pedal in tractor seat simulator and in the tractor running on various roads. From the results of the static test in the Lab, it was shown that more the seatbelt anchorage point is far form SIP point, more the body pressure of the belly became higher, and more the subjects feel uncomfortable. Not only in the static test in the simulator, but also in the dynamic test in riding tractors, it was shown that non retractable seatbelt was more uncomfortable than retractable seatbelt. According to this study, we concluded that we need to promote the utilization of the ROPS and seatbelt use. And, the non retractable seatbelt need to be replaced by retractable seatbelt. Also, we recommend that the seatbelt anchorage position should to be in the seatbelt anchorage area of the ISO 3776 standard.

Development of Silm Type ELCB For Airport Distribution Panel through Increased short Circuit Capacity (단락용량 증대를 통한 슬림형 공항 분전반용 누전 차단기 개발)

  • Joo, Nam-Kyu;Lee, Jong-Myong;Kim, Nam-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.2
    • /
    • pp.360-366
    • /
    • 2012
  • In the power distribution panel installed in airport or industrial facilities, MCCB has been used for main switch and ELCB for branch switch to perform human body and leakage-inducing fire protection as well as overcurrent and short circuit protection. Especially for the airport panel, increase in accident protection is needed for stable power supply due to rapid modernization with fast-growing users, higer capacity and diversification of equipment, the increase of power capacity and the breaker made slim is a main issue for now because the issue for installation space is standing out by making panel with two-row arrangement connection method, etc. due to a many use of branch ELCBs. In this thesis, we designed arc extinguishing mechanism, considered movement direction change of contact in mechanism design. Also, we designed the breaker to work stably in case of miniaturization of leakage detection circuit and reverse connection. We conducted short circuit test to verify its function and developed the breaker that can be improved protection against accidental current with slim size operating leakage function when reverse connection to help solve the problem in using space that is increasing in the airport distribution panel.

ASSESSMENT OF WIND CHARACTERISTICS AND ATMOSPHERIC DISPERSION MODELING OF 137Cs ON THE BARAKAH NPP AREA IN THE UAE

  • Lee, Jong Kuk;Kim, Jea Chul;Lee, Kun Jai;Belorid, Miloslav;Beeley, Philip A.;Yun, Jong-Il
    • Nuclear Engineering and Technology
    • /
    • v.46 no.4
    • /
    • pp.557-568
    • /
    • 2014
  • This paper presents the results of an analysis of wind characteristics and atmosphere dispersion modeling that are based on computational simulation and part of a preliminary study evaluating environmental radiation monitoring system (ERMS) positions within the Barakah nuclear power plant (BNPP). The return period of extreme wind speed was estimated using the Weibull distribution over the life time of the BNPP. In the annual meteorological modeling, the winds from the north and west accounted for more than 90 % of the wind directions. Seasonal effects were not represented. However, a discrepancy in the tendency between daytime and nighttime was observed. Six variations of cesium-137 ($^{137}Cs$) dispersion test were simulated under severe accident condition. The $^{137}Cs$ dispersion was strongly influenced by the direction and speed of the main wind. A virtual receptor was set and calculated for observation of the $^{137}Cs$ movement and accumulation. The results of the surface roughness effect demonstrated that the deposition of $^{137}Cs$ was affected by surface condition. The results of these studies offer useful information for developing environmental radiation monitoring systems (ERMSs) for the BNPP and can be used to assess the environmental effects of new nuclear power plant.

The Study on User's Continuance Intention of Traceability System between Agricultural and Marine Products (식품 유형간 이력추적시스템의 지속사용의도에 미치는 영향에 관한 연구)

  • Lee, Seung-Yook;Park, Hyeon-Suk
    • Journal of Distribution Science
    • /
    • v.14 no.4
    • /
    • pp.67-79
    • /
    • 2016
  • Purpose - Over recent years, we have concerned about safety and quality on food products because of delivery complexity. The dependence of foreign food products escalate supply of products. And there are often negligent accident of marine and agricultural products. Therefore, the complexity increases the importance of safety on food and information quality for consumers. In spite of the interest augmentation of various interested parties, there is decrease in reliability and effectiveness, if it would be established without the right directivity. For the study, we tried to examine the first considerations the point of - view in service environment and information quality with accepting and diffusing the Traceability System. Then, we tried to verify the relationships between the factors of TS and the determinants of behavior decision. Next, we made efforts to find the mutual relationship among distributors, producers, consumers and the other prerequisite factors from the point of view in service environment and information quality in order to operate effectively the information perspective and system. Research design, data, and methodology - For the purpose of this study, the samples of consumers were targeted to Traceability System, and 661 people have been investigated. Through theoretical discussion of previous research, nine hypotheses were established, the influence of Continuous User Intention in TS. In order to test the hypotheses, a survey had conducted for 661 consumers as opinion leaders in their 20s-60s as data, and structural equation modeling was used. The difference analysis between Agricultural and Marine Products in TS; SPSS 22.0 and AMOS 22.0 were used for statistical analysis. Results - The major findings from this study were as follow; all factors of information quality excluding completeness and a social-impact had effects on the ease of use; all factors excluding understand ability in information quality and a social-impact had effects on the usefulness; completeness and social-impact had effects on perceived value; the ease of use had effects on usefulness and perceived value; usefulness had effects on perceived value and the intention of continuous use. From the results of different analysis, the CPLT(Completeness) factor has positive effects on Easy of USE and PV(Perceived Value) strongly in agricultural products. On the other hand, Social Duty has positive effects on Easy of Use strongly in marine products. Conclusion - In the age of information overflowing, TS will be a burden for users if it places too much emphasis upon accessibility. To accept and diffuse TS safely, therefore, Information System should be settled first into initial market formation. In addition, if TS elements are considered in conjunction with information factors and user environment, the acceptance and diffusion of TS would make synergy effect, even better. That is, this study contributes to the acceptance and diffusion of Traceability System. Accordingly, information quality will be settled into initial market formation. Also, social-impact element will be considered in conjunction with information quality's factors, and it will make synergy effect.

A Study on the Vent Path Through the Pressurizer Manway and Steam Generator Manway under Loss of Residual Heat Removal System During Mid-loop Operation in PWR (가압경수로의 부분충수 운전중 잔열제거계통 기능 상실사고시 가압기와 증기발생기 Manway 유출유로를 이용한 사고완화에 관한 연구)

  • Y. J. Chung;Kim, W. S.;K. S. Ha;W. P. Chang;K. J. Yoo
    • Nuclear Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.137-149
    • /
    • 1996
  • The present study is to analyze an integral test, BETHSY test 6.9c, which represent loss of RURS accident under mid-loop operation. Both the pressurizer manway and the steam generator outlet plenum manway are opened as vent paths in order to prevent the system from pressurization by removing the steam generated in the core. The main purposes are to gain insights into the physical phenomena and identify sensitive parameters. Assessment of capability of CATHARE2 prediction can be established the effective recovery procedures using the code in an actual plant. Most of important physical phenomena in the experiment could be predicted by the CATHARE2 code. The peak pressure in the upper plenum is predicted higher than experimental value by 7 kPa since the differential pressure between the pressurizer and the surge line is overestimated. The timing of core uncovery is delayed by 500 seconds mainly due to discrepancy in the core void distribution. It is demonstrated that openings of the pressurizer manwey and the steam generator manway can prevent the core uncovery using only gravity feed injection. Although some disagreements are found in the detailed phenomena, the code prediction is considered reasonable for the overall system behaviors.

  • PDF

Comparison Of CATHARE2 And RELAP5/MOD3 Predictions On The BETHSY 6.2% TC Small-Break Loss-Of-Coolant Experiment (CATHARE2와 RELAP5/MOD3를 이용한 BETHSY 6.2 TC 소형 냉각재상실사고 실험결과의 해석)

  • Chung, Young-Jong;Jeong, Jae-Jun;Chang, Won-Pyo;Kim, Dong-Su
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.126-139
    • /
    • 1994
  • Best-estimate thermal-hydraulic codes, CATHARE2 V1.2 and RELAP5/MOD3, hate been assessed against the BETHSY 6.2 tc six-inch cold leg break loss-of-coolant accident (LOCA) test. Main objective is to analyze the overall capabilities of the two codes on physical phenomena of concern during the small break LOCA i.e. two-phase critical flow, depressurization, core water level de-pression, loop seal clearing, liquid holdup, etc. The calculation results show that the too codes predict well both in the occurrences and trends of major two-phase flow phenomena observed. Especially, the CATHARE2 calculations show better agreements with the experimental data. However, the two codes, in common, show some deviations in the predictions of loop seal clearing, collapsed core water level after the loop seal clearing, and accumulator injection behaviors. The discrepancies found from the comprision with the experimental data are larger in the RELAP5 results than in the CATHARE2. To analyze the deviations of the two code predictions in detail, several sensitivity calculations have been performed. In addition to the change of two-phase discharge coefficients for the break junction, fine nodalization and some corrections of the interphase drag term are made. For CATHARE2, the change of interphase drag force improves the mass distribution in the primary side. And the prediction of SG pressure is improved by the modification of boundary conditions. For RELAP5, any single input change doesn't improve the whole result and it is found that the interphase drag model has still large uncertainties.

  • PDF

An Experimental Study on Flow Distributor Performance with Single-Train Passive Safety System of SMART-ITL (SMART-ITL 1 계열 피동안전계통을 이용한 유동분사기 성능에 대한 실험연구)

  • Ryu, Sung Uk;Bae, Hwang;Yang, Jin Hwa;Jeon, Byong Guk;Yun, Eun Koo;Kim, Jaemin;Bang, Yoon Gon;Kim, Myung Joon;Yi, Sung-Jae;Park, Hyun-Sik
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.124-132
    • /
    • 2016
  • In order to estimate the effect of flow distributors connected to an upper nozzle of CMT(Core Makeup Tank) on the thermal-hydraulic characteristics in the tank, a simplified 2 inch Small Break Loss of Coolant Accident(SBLOCA) was simulated by skipping the decay power and Passive Residual Heat Removal System(PRHRS) actuation. The CMT is a part of safety injection systems in the SMART (System Integrated Modular Advanced Reactor). Each test was performed with reliable boundary conditions. It means that the pressure distribution is provided with repeatable and reproducible behavior during SBLOCA simulations. The maximum flow rates were achieved at around 350 seconds after the initial opening of the isolation valve installed in CMT. After a short period of decreased flow rate, it attained a steady injection flow rate after about 1,250 seconds. This unstable injection period of the CMT coolant is due to the condensation of steam injected into the upper part of CMT. The steady injection flow rate was about 8.4% higher with B-type distributor than that with A-type distributor. The gravity injection during hot condition tests were in good agreement with that during cold condition tests except for the early stages.