• 제목/요약/키워드: accessibility standard

검색결과 140건 처리시간 0.025초

코드감소와 성능향상을 위한 이질 레지스터 분할 및 명령어 구조 설계 (Code Size Reduction and Execution performance Improvement with Instruction Set Architecture Design based on Non-homogeneous Register Partition)

  • 권영준;이혁재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권12호
    • /
    • pp.1575-1579
    • /
    • 1999
  • Embedded processors often accommodate two instruction sets, a standard instruction set and a compressed instruction set. With the compressed instruction set, code size can be reduced while instruction count (and consequently execution time) can be increased. To achieve code size reduction without significant increase of execution time, this paper proposes a new compressed instruction set architecture, called TOE (Two Operations Execution). The proposed instruction set format includes the parallel bit that indicates an instruction can be executed simultaneously with the next instruction. To add the parallel bit, TOE instruction format reduces the destination register field. The reduction of the register field limits the number of registers that are accessible by an instruction. To overcome the limited accessibility of registers, TOE adapts non-homogeneous register partition in which registers are divided into multiple subsets, each of which are accessed by different groups of instructions. With non-homogeneous registers, each instruction can access only a limited number of registers, but an entire program can access all available registers. With efficient non-homogeneous register allocator, all registers can be used in a balanced manner. As a result, the increase of code size due to register spills is negligible. Experimental results show that more than 30% of TOE instructions can be executed in parallel without significant increase of code size when compared to existing Thumb instruction set.

  • PDF

영유아보육시설의 생태교육 활성화를 위한 외부공간계획에 관한 연구 (A Study on the Outdoor Space Planning of Child Care Facility for Ecological Education)

  • 이지수;남해경
    • 한국농촌건축학회논문집
    • /
    • 제22권3호
    • /
    • pp.9-16
    • /
    • 2020
  • The trend emphasizes children-oriented, play-oriented ecological education programs for children's ecological education. And most of these nature -friendly and eco-friendly education takes place outdoors. Therefore, outdoor space planning is important in childcare facilities. This case study aims to analyze the actual conditions of outdoor spaces in daycare centers and to provide standard data for outdoor space planning. In order to provide basic data on the improvement direction and planning standards of outdoor spaces, this present study conducted the composition, utilization status and related problems of outdoor spaces for nature -friendly ecological education in childcare facilities. Accordingly, outdoor space planning for ecological education should consider outdoor space characteristics such as free and easy accessibility between indoor and outdoor spaces, openness of space, flexibility, dynamic/static space, and nature affinity. Therefore, for an ecological education environment, children should be able to freely approach nature and play in the natural environment without any restrictions and artificial controls. Also, in urban areas, natural environment such as parks and open spaces should be considered as outdoor play spaces for children.

웹 구술사료(口述史料) 아카이브 정보시스템의설계 및 평가용 가이드라인 개발에 관한 연구 (A Study on Designing and Developing Guidelines for Evaluation of Web Oral History Archives Information System)

  • 최은주;이정연
    • 정보관리학회지
    • /
    • 제26권4호
    • /
    • pp.277-298
    • /
    • 2009
  • 본 연구는 구술자료 아카이브 정보시스템 설계를 위하여 구술기록물의 생산, 수집절차, 접근의 용이성, 저작권 등에 대하여 논의하였으며, 웹 구술사료 아카이브 설계 구축을 위한 기본 방안과 평가를 위한 가이드라인을 개발함으로써 웹 구술사료 아카이브 구축을 위해 활용 가능한 기준을 제시해 보고자 하였다. 이를 위해 평가 프레임워크를 기반으로 국내외 웹 구술사료 아카이브 5개 기관을 선정하여 연구자가 제시한 평가용 가이드라인을 적용하여 사례분석을 하였다. 여기에서 얻어진 결과를 바탕으로 국내의 웹 구술사료 아카이브 정보시스템 구축을 위한 개선점을 논의하였다.

숲길에서의 Barrier-Free 인증제도 개발에 관한 연구 (Development of Certification Program for Barrier-Free in Forest Trail)

  • 권형근;최윤호;김명준;염인환;이준우
    • 농업과학연구
    • /
    • 제37권1호
    • /
    • pp.37-43
    • /
    • 2010
  • This study carried out to develop barrier-free certification program in forest trail. It is done to provide the certification system presented about certification organized, certification standard and indexes, evaluation method and operation plan. In order to develop certification program in forest trail, detailed measurement index must be developed earlier based on an accessbility, a stability, a preservation and a walking continuity. The suitable forest trail for weak pedestrian was investigated that running slope should be 1/20(5%) maximum, cross slope cannot exceed 1/50(2%) maximum and clear tread width should be above of minimum 90cm. In addition, the trail type is designed as a mixed trail system which is a combination of the loop and the line form and its distance should be 225~675m. Finally, forest trail should be manage sustainably by having regular monitoring and evaluation.

A comparison study between the AESOPUS Low Temperature Opacity and that of Ferguson, on Standard Stellar Models and Isochrones

  • Kim, Yong-Cheol;Beom, Minje
    • 천문학회보
    • /
    • 제43권1호
    • /
    • pp.63.3-63.3
    • /
    • 2018
  • A comparison study between two low temperature opacity tables has been conducted. The opacity is the one of the major input physics in stellar model construction. Opacity is generally provided in a tabular form and as a function of 3 parameters, ie, density, temperature and chemical composition. Among available opacity tables, it has been common practice to utilize OPAL opacity table (Iglesias & Rogers, 1996) augmented with Ferguson opacity table (Ferguson et al. 2005) for the low temperature domain. For low temperature domain, another table, AESOPUS (Marigo & Aringer, 2009), has been announced in 2007. Reportedly, this opacity covers even lower temperature region, and is compatible with that of Ferguson in the overlapping temperature domain. To test the compatibility, stellar models and isochrones for various ranges in mass, metallicity and chemical composition, have been constructed. It is confirmed that there is no significant difference in the stellar models and isochrones constructed with the two different low temperature opacities. Therefore, in the construction of stellar models and isochrones, Ferguson low temperature opacity can be replaced with the AESOPUS opacity. The wider range in the temperature and chemical mixtures, and the easier accessibility make AESOPUS favorable in practical purpose.

  • PDF

학령기 여아를 위한 경기용 피겨 스케이팅복 패턴 설계에 관한 연구 (Pattern Development of Figure Skating Wear for Schoolgirls)

  • 박상희
    • 패션비즈니스
    • /
    • 제18권2호
    • /
    • pp.54-65
    • /
    • 2014
  • This study developed basic pattern for competition figure skating wear for school girls. Figure skating wears are difficult for making basic patterns based on standard size chart, because girls' body size are slimmer and more slender compared to the general girl's and the competition wears such as, swim suit with sleeves are, closely in contact with the player's body. The competition wears for school girl was made with consideration of changing of the body shape, physical exercises, and various specificities according to stretch material. To raise artistic effect while doing beautiful motions, and to assist in facile technique motions, competition wears need to have enough ease on the side line from waist to armpit, from armpit to wrist, and in trunk girth including crotch girth. Also, to stand out in beauty, a costume designing has a proper skirt position, length, flare width, and a tight bodice according to the player's body proportion. Most of the customers are displeased at the high price, unfitness of size, insufficient design, and difficulty in access, since they are not sold in sporting goods store. Therefore, a competition wear's basic pattern was made through scientific and emotional process including concerns on material properties, room for activities, and ideal body proportion. Systemizing the basic patterns of production method will solve high repairing expenses, unsuitable sizing, and improve accessibility for purchase.

옥상녹화의 녹화유형별 기온저감효과 (A Study on the Analysis of Temperature Reduction Effect by the Types of the Green Roof)

  • 이춘우;김수봉;문혜식
    • 한국주거학회논문집
    • /
    • 제22권3호
    • /
    • pp.25-33
    • /
    • 2011
  • Recently, concerns about conserving proper size of urban green spaces and accessibility are increasing, regarding it as a solution to diverse urban environmental problems including pollution, ecosystem deterioration, urban climate change. Artificial ground greening such as green roofs is regarded as the only alternative that can conserve green spaces which are impossible to be secured on the ground. However, green roofs are not popularized yet and levels are very low in provincial cities despite of related technology development and support systems of related agencies. Based on the background, this study tries to present a theoretical basis of methods for green roofs, conducting green roof simulations Finally, it aims to offer base data which help establish policy direction for activation of green roof technology. As a result of a simulation for verifying temperature reduction effect, it was possible to affirm effect of a plot that green roofs applied. Especially, it was revealed that a green roof method using ground covers such as mixed planting was the most effective way to reduce temperature. Based on precise analysis of the users, actual study for activation of green roofs should be developed in the future, by presenting a standard model for experiments and obtaining information about examples of green roofs on private houses.

도심지에 있어서 공공도서관 지역계획에 관한 연구(1) - 공공도서관 지역배치계획 기준을 중심으로 - (A Study on the Planning of Public Library System to Regional Area in Downtown - Focused on the Standards of Arrangement to Regional Area in Public Library -)

  • 최동식;이상호
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2004년도 추계학술발표대회 논문집
    • /
    • pp.19-24
    • /
    • 2004
  • The Necessity of extending the local library become inevitable because of the swift increasing the volume of information and enlarging the accessibility and increasing the requirements approached to the latest information, caused by continuous development of communication techniques. But these requirements have been concentrated at the quantitative growth to some extent such as an unique and mammoth library at an region or some few independent libraries, never to be considered enough for the users' convinience so that these locational conditions impede the utilization of library As to this matter, this is a basic research what's the best selection of arrangement for establishing public libraries in the future according to the planning regional area and this is the purpose to present a standard of planning regional area in consideration with user's easyaccesibility and also the facilities selecting activities of user's character and set up a planning the basic data about facilities arrangement and space scale before unfolding it's own public service activities of public library as the role of the regional and social information center

  • PDF

항로표지 충·방전조절기의 제어에 관한 연구 (Studies on the Control of AtoN Charge and Discharge Controller)

  • 예성현;한순희
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 추계학술대회
    • /
    • pp.654-657
    • /
    • 2014
  • 본 논문에서는 항로표지 충 방전조절기의 근거리 제어방법을 제안하였다. 제안하는 제어방법은 국내에서 운용되는 충 방전조절기의 제어기능을 분석하여 항로표지시설의 통신규격인 NEMA018을 적용하여 구성하였다. 제안된 제어방법을 이용하면 제품분해 없이 방수성을 유지하면서 유 무선통신으로 제어가 가능한 장점이 있다. 또한 운용중인 충 방전조절기의 접근성을 확보할 수 있어 유지보수에 효과적이다. 본 논문에서는 스마트폰에 충 방전조절기 제어를 위한 응용프로그램을 설치하고 블루투스 통신과 PC를 이용하여 제어정보의 유효성을 검토한다. 향후 제안하는 충 방전조절기의 제어방법은 국내 표준으로 제안할 수 있다.

  • PDF

원격측정용 다기능 PCM 데이터 저장장치 개발 (Developement of Multifunction PCM Recorder for Telemetry System)

  • 김대연;김재민;고광렬;이상범
    • 한국군사과학기술학회지
    • /
    • 제26권2호
    • /
    • pp.171-178
    • /
    • 2023
  • PCM data is result of air-vehicle flight test, this data is distributed for each engineers to analyze its condition. Since line-of-sight between the air-vehicle and the ground receiver cannot always be secured, remote PCM data recording system was claimed to be required. In this paper multi-function PCM data recorder has been described. This PCM data recorder was intended to place on inside of flight object. It can record about two hours in 32 GB SD card with maximum 7 Mbps data rate. RS-422/485 and RJ-45 interface enhanced accessibility for users. 5 V and 1 A power consumption and 19.5 mm × 152.5 mm × 102.3 mm allow to connect with mobile PCM devices. It acquired more than 190-minutes data in 12-times flight test. Also, it achieved military standard environmental test MIL-STD-810G to prove its stability and solidness.