• Title/Summary/Keyword: access charge

Search Result 180, Processing Time 0.028 seconds

A Characteristics of Maintenance Planning of Trees in Historical Landscape Forest of Royal Tombs of the Joseon Dynasty (조선왕릉 역사경관림 수목 정비 계획의 특성)

  • So, Hyun-Su;Lee, Jong-Keun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.36 no.3
    • /
    • pp.88-99
    • /
    • 2018
  • After UNESCO appointed Royal Tombs of the Joseon Dynasty to be World Cultural Heritages(2009), Cultural Heritage Administration in Korea established Management Office of Royal Tombs of the Joseon Dynasty(2012) and conducted Mid to Long-Term Plan on Conservation, Management, Utilization of World Heritage 'Royal Tombs of the Joseon Dynasty(2015)'. The report, as an implementation plan, provides detailed contents of the maintenance planning of Royal Tombs of the Joseon Dynasty. From this background, with a view to comprehending the characteristics of the maintenance planning of trees in historical landscape forests, this study extracted the contents related to the historical landscape forests of the 40 Royal Tombs of the Joseon Dynasty from the "Mid to Long-term Plan" and conducted literature research. The results of the study are as follows. First, from 2016, the short-term plans have provided detailed contents on logging, transplanting and planting trees in the plans divided by stages. On the other hand, the long-term plans, instead of presenting abstract contents repeatedly for each royal tomb, should seek vegetation landscape that each royal tomb should aim for. Second, since the areas that are in charge of the various functions of the royal tombs have been subjects to the maintenance planning, it is effective to establish a maintenance planning by separating functional areas instead of the comprehensive concept as historical landscape forests. Third, the maintenance planning of trees in historical landscape forest of the Royal Tombs of Joseon Dynasty is based on daily management such as density control and maintaining the shape of trees, which is necessary to sustain the forest. Also, due to the goal of preserving the pine forest, which is recognized as a prototype vegetation landscape, foreign species and other trees have been more cut down. With a few limited types of tall tree but few shrubs and flowers, it is characterized that the orientation toward aesthetic landscapes is insufficient in large green spaces. Fourth, according to the function of the tomb, it is divided into entrance area, ceremonial area, burial area and outer forest, and the contents of the maintenance planning are analyzed by basic conditions of tree management: prototype, ecology, functionality, and aesthetics. After studying the tree management characteristics of each area, four suggestions are made: understanding the diversity of trees that form prototype landscape as a management plan, sustainability of various forests adapted to ecological environment, convenience required in addition to ceremony and safety characterizing the Royal Tombs of Joseon Dynasty, and the necessity of access to aesthetic landscape on the tombs.

Diagnosis and Improvements Plan Study of CIPP Model-based Vocational Competency Development Training Teacher Qualification Training (Training Course) (CIPP 모형 기반 직업능력개발훈련교사 자격연수(양성과정) 진단 및 개선 방안 연구)

  • Bae, Gwang-Min;Woo, Hye-Jung;Choi, Myung-Ran;Yoon, Gwan-Sik
    • Journal of vocational education research
    • /
    • v.36 no.2
    • /
    • pp.95-121
    • /
    • 2017
  • The vocational competency development training teacher must complete the training course for the training of vocational competency development training instructor and get the qualification of the vocational competency development training teacher from the Ministry of Employment & Labor with the criteria set by the Presidential Decree. Therefore, it can be said that H_university 's educational performance, which is the only vocational competency development training teacher in Korea and that plays a role of mass production in the labor market, has a great influence on vocational competency development training. The purpose of this study is to identify the problems through the analysis of actual condition of vocational competency development training education based on CIPP model, Furthermore, it was aimed to suggest improvement plan of qualification training education. In order to accomplish the purpose of the research, the present situation of the training course for the vocational competency development training teacher training students was grasped. And We conducted a survey to draw out the improvement plan and utilized the results of 173 copies. We conducted interviews by selecting eight subjects for in-depth analysis and Understand the details of the results of the surveys conducted. As a result of the study, positive responses were obtained from the educational objectives and educational resources in the context factors. On the other hand, there were negative opinions about the curriculum reflecting the learner and social needs. In the input factors, positive opinions were derived from the educational objectives and training requirements. However, there were many negative opinions about the achievement of the learner's educational goals. In addition, there were many negative opinions of online contents education. In the process factors, positive evaluation was high in class related part, learner attendance management, and institutional support. However, negative opinions were drawn on the comprehensive evaluation of qualification training period, and the learner's burden due to lack of learning period appeared to be the main reason. In the factor of calculation, Positive opinions were derived from the applicability of the business curriculum for training courses for training teachers who are in charge of education and training in industry occupations. However, there were negative opinions such as learning time, concentration of learning, and communication of instructors. Based on the results of the study, suggestions for improving the operation of vocational competency training teacher qualification training are as follows. First, it is necessary to flexibly manage the training schedule for the weekly training course for vocational competency development training teachers. Second, it is necessary to seek to improve the online education curriculum centered on consumers. Third, it is necessary to seek access to qualification training for local residents. Fourth, pre - education support for qualified applicants is required. Finally, follow-up care of qualified trainees is necessary.

Operative Challenges in Releasing Administrative Information and Records (행정정보 및 보존기록물 공개의 운영과제)

  • Lee, Won-Kyu
    • The Korean Journal of Archival Studies
    • /
    • no.12
    • /
    • pp.81-135
    • /
    • 2005
  • The release of administrative information has been the challenge of our age following the maturation of democratic ideology in our society. However, differences of opinion and conflict still exist between the government and private sectors regarding the issue, and it seems that the technical and policy-related insufficiencies of information and record management that actually operate the release of information are the main causes. From the perspective of records management, records or information are variable in their nature, value, and influence during their life span. The most controversial issue is the records and information in the current stage of carrying out business activities. This is because the records and information pertaining to finished business are but evidence to ascertain the past, and have only a limited relationship to the ideal of the 'democratic participation' by citizens in activities of the public sector. The current information release policies are helpless against the 'absence of information,' or incomplete records, but such weakness can be supplemented by enforcing record management policies that make obligatory the recording of all details of business activities. In addition, it is understood that the installation of 'document offices("Jaryogwan")' that can manage each organization's information and records will be an important starting point to integrate the release, management, and preservation of information and records. Nevertheless, it seems that the concept of 'release' in information release policies refers not to free use by all citizens but is limited to the 'provision' of records according to public requests, and the concept of 'confidential' refers not to treating documents with total secrecy but varies according to the particulars of each situation, making the actual practice of information release difficult. To solve such problems, it is absolutely necessary to collect the opinions of various constituents associated with the recorded information in question, and to effectively mediate the collective opinions and the information release requests coming from applicants, to carry out the business more practically. Especially crucial is the management of the process by which the nature and influence of recorded information changes, so that information which has to be confidential at first may become available for inquiry and use over time through appropriate procedures. Such processes are also part of the duties that record management, which is in charge of the entire life span of documents, must perform. All created records will be captured within a record management system, and the record creation data thus collected will be used as a guide for inquiry and usage. With 'document offices(Jaryogwan)' and 'archives' controlling the entire life span of records, the release of information will become simpler and more widespread. It is undesirable to try to control only through information release policies those records the nature of which has changed because, unlike the ones still in the early stages of their life span and can directly influence business activities, their work has finished, and they have become historical records or evidences pointing to the truth of past events. Even in the past, when there existed no formal policy regarding the release of administrative information, the access and use of archival records were permitted. A more active and expanded approach must be taken regarding the 'usage' of archival records. If the key factor regarding 'release' lies in the provision of information, the key factor regarding 'usage' lies in the quality and level of the service provided. The full-scale usage of archival records must be preceded by the release of such records, and accordingly, a thorough analysis of the nature, content, and value of the records and their changes must be implemented to guarantee the release of information before their use is requested. That must become a central task of document offices and "Today's information" will soon become "yesterday's records," and the "reality" of today will become "history" of the past. The policies of information release and record management share information records as their common objective. As they have a mutual relationship that is supplementary and leads toward perfection, the two policies must both be differentiated and integrated with each another. It is hoped that the policies and business activities of record management will soon become normalized and reformed for effective and fair release of information.

Military Activity and Combat in Hapcheon Area during the Imjin Invasion Period (임진왜란시기 합천지역의 의병 활동과 전투)

  • Kwak, Nak-hyun
    • (The)Study of the Eastern Classic
    • /
    • no.70
    • /
    • pp.257-301
    • /
    • 2018
  • The purpose of the study is to examine righteous army activity and combat in Hapcheon during the Imjin invasion period. The resulting conclusions are as follows. First, Chung In-hong raised a righteous army in Hapcheon and Kim Myeon raised an army in Goryeong. Chung In-hong commanded the army and fought against Japanese army with a leadership of knowing the enemy and himself, and Kim Myeon commanded the army and fought against Japanese military with a leadership of harmony. Second, battles of Chung In-hong's righteous army are the first Mugye battle, the ambush battle in Sawon-dong, the Chogye Majin battle, the Aneon battle, and the third Seongju Castle battle. Battles of Kim Myeon's righteous army are the Yeongang battle, the Gaesanpo battle, the second Mugye battle, the Ucheok-hyeon battle, the Jirye battle, and the Sarangam battle. Battles that Chung In-hong and Kim Myeon united and fought are the first and second Seongju Castle battles. In Jeongyu Jaeran, Chung In-hong played a role of Jodosa who takes charge of provisions in the right area of Gyeongsang. In addition, Hapcheon was the access road and transport route where Japanese army entered Jeolla-do. Third, participation and role of Ming troops are part of restraint device against Japanese army with military tactics of ii chei(using foreigners to control foreigners) to remove Japanese army from Joseon and defend Yodong. After a victory of Li Rusong in Pyeongyang Castle in January, 1593(the 26th year of Seongjo), Ming troops pursued practical interest through peace talks rather than active battles. When there was practically Siege of Jinju, Yujeong troops of Ming entered with hand-to-hand martial arts of Sacheon soldiers in late June, 1593, but did not participate because they should wait for orders of Gyeongnyak Song Eung-chang and Admiral Li Rusong. Fourth, in the Imjin invasion period, Joseon suffered terrible damage such as ruin of the whole country by invasion of Japanese army and in need of aid of military rice from Ming troops, but righteous armies and the royal forces in each area cooperated so defeated Japanese army. It is understood through a case of Hapcheon in the right area of Gyeongsang. Especially, Joseon did not succumb to pressure of Ming troops that used full powers to two aspects such as settlement and battle with Japan during the war, and did not lose national confidence and pride by showing a fighting will to fight against Japanese army to the end with independence. Such a spiritual culture originated from homeland protection and loyalty to the king, and is national spirit of resistance that sublimates the united mind and spirit of community to protect a country against foreign invasion.

Survey of Operation and Status of the Human Research Protection Program (HRPP) in Korea (2019) (임상시험 및 대상자보호프로그램의 운영과 현황에 대한 설문조사 연구(2019))

  • Maeng, Chi Hoon;Lee, Sun Ju;Cho, Sung Ran;Kim, Jin Seok;Rha, Sun Young;Kim, Yong Jin;Chung, Jong Woo;Kim, Seung Min
    • The Journal of KAIRB
    • /
    • v.2 no.2
    • /
    • pp.37-48
    • /
    • 2020
  • Purpose: The purpose of this study is to assess the operational status and level of understanding among IRB and HRPP staffs at a hospital or a research institute to the HRPP guideline set by the Ministry of Food and Drug Safety (MFDS) and to provide recommendations. Methods: Online survey was distributed among members of Korean Association of IRB (KAIRB) through each IRB office. The result was separated according to topic and descriptive statistics was used for analysis. Result: Survey notification was sent out to 176 institutions and 65 (37.1%) institutions answered the survey by online. Of 65 institutions that answered the survey; 83.1% was hospital, 12.3% was university, 3.1% was medical college, 1.5% was research institution. 23 institutions (25.4%) established independent HRPP offices and 39 institutions (60.0%) did not. 12 institutions (18.5%) had separate IRB and HRPP heads, 21 (32.3%) institutions separated business reporting procedure and person in charge, 12 institutions separated the responsibility of IRB and HRPP among staff, and 45 institutions (69.2%) had audit & non-compliance managers. When asked about the most important basic task for HRPP, 23% answered self-audit. And according to 43.52%, self-audit was also the most by both institutions that operated HRPP and institutions that did not. When basic task performance status was analyzed, on average, the institutions that operated HRPP was 14% higher than institutions that only operated IRB. 9 (13.8%) institutions were evaluated and obtained HRPP accreditation from MFDS and the most common reason for obtaining the accreditation was to be selected as Institution for the education of persons conducting clinical trial (6 institutions). The most common reason for not obtaining HRPP accreditation was because of insufficient staff and limited capacity of the institution (28%). Institutions with and without a plan to be HRPP accredited by MFDS were 20 (37.7%) each. 34 institutions (52.3%) answered HRPP evaluation method and accreditation by MFDS was appropriate while 31 institutions (47.7%) answered otherwise. 36 institutions answered that HRPP evaluation and accreditation by MFDS was credible while 29 institutions (44.5%) answered that HRPP evaluation method and accreditation by MFDS was not credible. Conclusion: 1. MFDS's HRPP accreditation program can facilitate the main objective of HRPP and MFDS's HRPP accreditation program should be encouraged to non-tertiary hospitals by taking small staff size into consideration and issuing accreditation by segregating accreditation. 2. While issuing Institution for the education of persons conducting clinical trial status as a benefit of MFDS's HRPP accreditation program, it can also hinder access to MFDS's HRPP accreditation program. It should also be considered that the non-contact culture during COVID-19 pandemic eliminated time and space limitation for education. 3. For clinical research conducted internally by an institution, internal audit is the most effective and sole method of protecting safety and right of the test subjects and integrity for research in Korea. For this reason, regardless of the size of the institution, an internal audit should be enforced. 4. It is necessary for KAIRB and MFDSto improve HRPP awareness by advocating and educating the concept and necessity of HRPP in clinical research. 5. A new HRPP accreditation system should be setup for all clinical research with human subjects, including Investigational New Drug (IND) application in near future.

  • PDF

A Study on the Policy Directions of Sports Welfare in Gangwon Province for Improving Quality of Life (삶의 질 향상을 위한 강원도 스포츠복지 정책방향 연구)

  • Kim, Heung-Tae;Kim, Tae-Dong
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.8
    • /
    • pp.411-424
    • /
    • 2019
  • The purpose of this study is to explore the feasible policy directions for sports welfare that can not only improve the standard of living through health but also ensure a happy and enjoyable life for the people of Gangwon Province. For this purpose, I have conducted studies such as the analysis on the sports class voucher project being implemented by the South Korean government and the case analysis in sports welfare, and present policy directions as follows. First of all, it is about upgrading the sports class voucher project. And as its implementation plans, I suggest ① increased publicity, ② the earmarking of the province's own budget for the sports class voucher project, ③ the establishment of a system for cooperation for work implementation between the related organizations and their staff in charge with a view to activating the sports class voucher project, and ④ the upgraded services for the sports class voucher project and the upgraded access to the life cycle-based universal welfare. Second, it is about using public sports facilities and developing various programs. I suggest the active utilization of the public sports facilities that enable people to learn the skills for such sports disciplines as baseball, badminton, ice sports, and golf and the development and distribution of distinctive educational programs for dance for media entertainment shows for female youths, climbing, cheer leading, fencing, surfing and horseback riding. Third, it is about nurturing the human resources and networking. For this, I suggest the creation of 'Sports Welfare Specialist Training Program' and the training of the college students majoring in sports science with the aim of creating a number of jobs. Fourth, it is about refurbishing the system and establishing the support system. I suggest the dismantling of the partitions in the welfare policy related to sports activities and the formation of (tentatively named) 'Gangwon Province Sports Welfare Implementation Committee', and the creation of (tentatively named) 'Sports Welfare Project Support Team' in Health, Welfare & Women's Affairs Bureau or Culture, Tourism and Sports Bureau in the short term and then its long-term expansion into (tentatively named) 'Gangwon Province Sports Welfare Support Center' in responding to the needs that reflect the provincial demographics, with a view to establishing a single lineup for the administrative support system. Furthermore, as budget and manpower are needed to realize customized sports welfare that suits the characteristics of the province and in which all the provincial residents can collect benefits, I suggest that the province provide the legal basis through creating 'Ordinance Promoting Sports Welfare in Gangwon Province' and pushing forward with (tentatively named) 'Gangwon Province Sports Welfare Competition' as what revises the sports class voucher project for the purpose of broadening the basis for sports welfare promotion.

A Study on the Operation Plan of the Gangwon-do Disaster Management Resources Integrated Management Center (강원도 재난관리자원 통합관리센터 운영방안에 관한 연구)

  • Hang-Il Jo;Sang-Beom Park;Kye-Won Jun
    • Journal of Korean Society of Disaster and Security
    • /
    • v.17 no.1
    • /
    • pp.9-16
    • /
    • 2024
  • In Korea, as disasters become larger and more complex, there is a trend of shifting from a focus on response and recovery to a focus on prevention and preparedness. In order to prevent and prepare for disasters, each local government manages disaster management resources by stockpiling them. However, although disaster management resources are stored in individual warehouses, they are managed by department rather than by warehouse, resulting in insufficient management of disaster management resources due to the heavy workload of those in charge. In order to intensively manage these disaster management resources, an integrated disaster management resource management center is established and managed at the metropolitan/provincial level. In the case of Gangwon-do, the subject of this study, a warehouse is rented and operated as an integrated disaster management resource management center. When leasing an integrated management center, there is the inconvenience of having to move the location every 1 to 2 years, so it is deemed necessary to build a dedicated facility in an available site. To select a location candidate, network analysis was used to measure access to and use of facilities along interconnected routes of networks such as roads and railways. During network analysis, the Location-Allocation method, which was widely used in the past to determine the location of multiple facilities, was applied. As a result, Hoengseong-gun in Gangwon-do was identified as a suitable candidate site. In addition, if the integrated management center uses our country's logistics system to stockpile disaster management resources, local governments can mobilize disaster management resources in 3 days, and it is said that it takes 3 days to return to normal life after a disaster occurs. Each city's disaster management resource stockpile is 3 days' worth per week, and the integrated management center stores 3 times the maximum of the city's 4-day stockpile.

The Location of Medical Facilities and Its Inhabitants' Efficient Utilization in Kwangju City (광주시(光州市) 의료시설(醫療施設)의 입지(立地)와 주민(住民)의 효율적(效率的) 이용(利用))

  • Jeon, Kyung-Sook
    • Journal of the Korean association of regional geographers
    • /
    • v.3 no.2
    • /
    • pp.163-193
    • /
    • 1997
  • Medical services are a fundamental and essential service in all urban areas. The location and accessibility of medical service facilities and institutions are critical to the diagnosis, control and prevention of illness and disease. The purpose of this paper is to present the results of a study on the location of medical facilities in Kwangju and the utilization of these facilities by the inhabitants. The following information is a summary of the findings: (1) Korea, like many countries, is now witnessing an increase in the age of its population as a result of higher living standards and better medical services. Korea is also experiencing a rapid increase in health care costs. To ensure easy access to medical consultation, diagnosis and treatment by individuals, the hierarchical efficient location of medical facilities, low medical costs, equalized medical services, preventive medical care is important. (2) In Korea, the quality of medical services has improved significantly as evident by the increased number of medical facilities and medical personnel. However, there is still a need for not only quantitative improvements but also for a more equitable distribution of and location of medical services. (3) There are 503 medical facilities in Kwangju each with a need to service 2,556 people. This is below the national average of 1,498 inhabitants per facility. The higher locational quotient and satisfactory population per medical facility showed at the civic center. On the other hand, problem regions such as the traditional residential area in Buk-Gu, Moo-deung mountain area and the outer areas of west Kwangju still maintain rural characteristics. (4) In the study area there are 86 general medicine clinics which provide basic medical services. i. e. one clinic per every 14,949 residents. As a basic service, its higher locational quotient showed in the residential area. The lower population concentration per clinic was found in the civic center and in the former town center, Songjeong-dong. In recently build residential areas and in the civic center, the lack of general medicine clinics is not a serious medical services issue because of the surplus of medical specialists in Korea. People are inclined to seek a consultation with a specialist in specific fields rather than consult a general practitioner. As a result of this phenomenon, there are 81 internal medicine facilities. Of these, 32.1% provide services to people who are not referred by a primary care physician but who self-diagnose then choose a medical facility specializing in what they believe to be their health problem. Areas in the city, called dongs, without any internal facilities make up 50% of the total 101 dongs. (5) There are 78 surgical facilities within the area, and there is little difference at the locational appearance from internal medicine facilities. There are also 71 pediatric health clinics for people under 15 years of age in this area, represents one clinic per 5,063 people. On the quantitative aspect, this is a positive situation. Accessibility is the most important facility choice factor, so it should be evenly located in proportion to demander distribution. However, 61% of 102 dongs have no pediatric clinics because of the uneven location. (6) There are 43 obstetrical and gynecological clinics in Kwangju, and the number of residents being served per clinic is 15,063. These services need to be given regularly so it should increase the numbers. There are 37 ENT clinics in the study area with the lower concentration in Dong-gu (32.4%) making no locational differences by dong. There are 23 dermatology clinics with the largest concentration in Dong-Gu. There are 17 ophthalmic clinics concentrated in the residential area because of the primary function of this type of specialization. (7) The use of general medicine clinics, internal medicine clinics, pediatric clinics, ENT clinics by the inhabitants indicate a trend toward primary or routine medical services. Obstetrics and gynecology clinics are used on a regular basis. In choosing a general medicine clinic, internal medicine clinic, pediatric clinic, and a ENT clinic, accessibility is the key factor while choice of a general hospital, surgery clinic, or an obstetrics and gynecology clinic, thes faith and trust in the medical practitioner is the priority consideration. (8) I considered the efficient use of medical facilities in the aspect of locational and management and suggest the following: First, primary care facilities should be evenly distributed in every area. In Kwangju, the number of medical facilities is the lowest among the six largest cities in Korea. Moreover, they are concentrated in Dong-gu and in newly developed areas. The desired number of medical facilities should be within 30 minutes of each person's home. For regional development there is a need to develop a plan to balance, for example, taxes and funds supporting personnel, equipment and facilities. Secondly, medical services should be co-ordinated to ensure consistent, appropriate, quality services. Primary medical facilities should take charge of out-patient activities, and every effort should be made to standardize and equalize equipment and facility resources and to ensure ongoing development and training in the primary services field. A few specialty medical facilities and general hospitals should establish a priority service for incurable and terminally ill patients. (9) The management scheme for the inhabitants' efficient use of medical service is as follows: The first task is to efficiently manage medical facilities and related services. Higher quality of medical services can be accomplished within the rapidly changing medical environment. A network of social, administrative and medical organizations within an area should be established to promote information gathering and sharing strategies to better assist the community. Statistics and trends on the rate or occurrence of diseases, births, deaths, medical and environment conditions of the poor or estranged people should be maintained and monitored. The second task is to increase resources in the area of disease prevention and health promotion. Currently the focus is on the treatment and care of individuals with illness or disease. A strong emphasis should also be placed on promoting prevention of illness and injury within the community through not only public health offices but also via medical service facilities. Home medical care should be established and medical testing centers should be located as an ordinary service level. Also, reduced medical costs for the physically handicapped, cardiac patients, and mentally ill or handicapped patients should be considered.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF