• Title/Summary/Keyword: accelerators

Search Result 339, Processing Time 0.027 seconds

Proposal for Comprehensive Quality Control of Heavy-Ion Medical Accelerator

  • Kim, Dong-wook;Shin, Dong-oh;Shin, Young-hoon;Heo, Hyun-do
    • Progress in Medical Physics
    • /
    • v.28 no.2
    • /
    • pp.67-75
    • /
    • 2017
  • Prior to the introduction of a medical apparatus based on heavy-ion medical accelerator in Korea, a study is needed on quality control in clinical operation for the safe and appropriate usage of the instrument. Data relevant for the study were obtained via information sharing sessions and visits by the Particle Therapy Co-Operative Group (PTCOG) and other related academic associations. Furthermore, investigative analysis of the European and Japanese performance evaluation guidelines for heavy ion, as well as research on relevant literature, were conducted. In addition, instrumental standards were analyzed through an investigation of the current usage status of the heavy-ion medical accelerator, and further analysis was conducted on the evaluation methods for the performance, safety, and significance of the instrument. Based on these analyses, regular quality control procedures for heavy-ion medical accelerators in hospitals and other institutes were extrapolated. It is hoped that the results of this study will facilitate hospitals that have introduced heavy-ion medical accelerators, or are considering the implementation of the instrument, in their understanding of the fundamental standards and capabilities of the treatment system, as well as in establishing and carrying out quality control procedures for clinical operations such that it will contribute to the safety of patients and the efficiency of medical practitioners.

Overexposed Accidents due to Erroneous Input to Treatment Planning System in Japan

  • Tabushi, Katsuyoshi;Endo, Masahiro;Ikeda, Hiroshi;Uchiyama, Yukio;Hoshina, Masao;Nakagawa, Keiichi;Sakai, Kunio
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.11-12
    • /
    • 2002
  • Accidental overexposures by radiotherapy have gathered attention recently in Japan. The widely publicized accidents have occurred at the government official benefit society hospital and at the hospital affiliated to a medical school. The accident at the government official benefit society hospital occurred when one of two existing accelerators was renewed. A radiotherapy planning system was also introduced at that time. Then treatment planning for the old and the new linear accelerator was performed using the system. There were variations in wedge factors for the 30 degrees wedge filter between the old and the new linear accelerator. That is, the difference in the structure of the wedge filter (30 degrees) resulted in variations of the wedge factors between both accelerators. In order to keep strength, a lead board was backed to the lead wedge filter for the new linear accelerator, whereas the wedge filter for the old one was made of the iron. The X-ray attenuation of the iron wedge filter is smaller than that of the lead wedge filter. The basic beam data of the old linear accelerator, however, wasn't delivered properly between the user and the maker. Then, the accident took place because the same wedge factor was used for the old and the new linear accelerator. On the other hand, the accident which occurred at the university hospital was brought about by the input mistake in initialization of the computer system when a linear accelerator was introduced. The input mistake was found when the software of the system was updated. If the dose had been measured and confirmed adequately, the accidents could have been prevented in both cases.

  • PDF

Short Aramid Fiber Reinforced Polyethylene and Epoxy Composity- I. Studies on the Curing Acceleration of Epoxy/Amine System by Differential Scanning Calorimeter (Aramid단섬유보강 고기능폴리에틸렌 및 에폭시 복합재료 제조- I.DSC에 의한 에폭시/아민계의 경화 촉진 연구)

  • Ha, Chan Sik;Lim, Seung Ha;Kim, Byung Kyu;Chin, Young Jo;Cho, Won Jei
    • Applied Chemistry for Engineering
    • /
    • v.3 no.1
    • /
    • pp.111-118
    • /
    • 1992
  • The curing acceleration of epoxy/amine system was investigated by using differential scanning calorimeter(DSC), The epoxy, diglycidylether of bisphenol A (DGEBA) was cured with methylene dianiline (MDA) with or without accelerators. Two kinds of accelerators were tested for the study ; tris(dimethylaminomethyl)phenol (DMP - 30) and 3 - (3,4 - dichlorophenyl)-1, 1-dimethylurea (DIURON). Heats of reaction and glass transition temperatures ($T_g$) of the cured epoxy system were analyzed by DSC along with the estimation of activation energy by the dynamic DSC studies. It was found that DMP - 30 is more effective accelerator than DIURON which showed faster curing and lower activation energy.

  • PDF

A Characteristics of Fly-ash Concrete Incorporating Tablet-shaped Accelerators in Cold Weather (한중 환경에서 정제된 급결제를 혼입한 플라이애시 콘크리트의 특성)

  • Lee, Yong-Soo;Ryou, Jae-Suk
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.1
    • /
    • pp.40-45
    • /
    • 2014
  • Although the accelerators are used at the early stage to control setting-time and strength of concrete when cold-weather concrete is utilized, no security of workability occurs because the early hydration makes them react rapidly. Therefore, the tablet used in previous study is applied in this study. In particular, because a small amount of fly-ash being replaced in cold weather concrete of domestic, fly-ash concrete incorporating the tablet is discussed in workability by elapsed time, early strength to ensure the development of adequate strength, and freezing-thawing resistance. As a result, both 0.5 and 1.0% tablets were found to be superior. Thus, it was verified in cold weather concrete incorporating fly-ash that workability can be secured, as well as the development of early strength to prevent early frost.

Evaluation of Depth Dose and Surface Dose According to Treatment Room Wall Distance (방사선 치료실 벽면 거리에 따른 심부선량과 표층선량 평가)

  • Je, Jae-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.121-125
    • /
    • 2011
  • This study was intended to evaluate the surface dose and depth dose of according to the distance of the treatment room wall. High energy photon beams from linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. The scattered radiation measured by thermoluminescence dosimeter(TLD). Linear accelerators rotation center of the four walls(X) distance was measured to be 236, 272, 303, and 337 cm. The result of 100 cGy and 200 cGy of 6 MV photon irradiation, surface dose was 0.49, 0.83 mSv at 236 cm of the shortest distance to the wall, In 272 cm 0.41, 0.53 mSv, 303 cm in the 0.28, 0.57 mSv, and 337 cm distance from the wall in the 0.33, 0.76 mSv surface dose respectively. There was remarkable difference in the surface dose among the treatment room wall distance. The results of useful data in relation to stochastic effect for radiation therapy patients.

The Influence of Entrepreneurial Competences on Corporate Performance of Technology-based Start-ups (창업가역량과 창업보육 프로그램 지원이 기술창업기업 경영성과에 미치는 영향 : 창업기업 역량의 매개효과 중심으로)

  • Kim, Jinhan;Cho, Jinhyung;Lee, Saejae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.43 no.1
    • /
    • pp.132-142
    • /
    • 2020
  • Many countries around the world are pursuing various support policies to foster start-ups national widely in order to secure new economic growth engines in the era of the Fourth Industrial Revolution. The South Korean government announced the diffusion strategy for the 2'nd round Start-up Boom in March 2019 and is promoting the support policies for start-up incubating by various programs. Many incubators and startup accelerators operate various kinds of programs to foster start-ups using government financial supports. The purpose of this study is to investigate the effects of entrepreneurship and technical capability of entrepreneurs as the internal factors of the technology-based start-ups and the effects of programs supported by the government as an external factor on the corporate performance of a start-up company, and the mediating effects of core competence of start-ups were analyzed using SPSS and AMOS. The results show that the entrepreneurship, technical capability and the programs supported by incubators or accelerators had no direct effects on the corporate performance of a start-up, but the core competence of the company had complete mediating effects. In addition, the type of program supported by the comprehensive accelerator programs or the marketing supports had effects on the core competence rather than simple financial supports. Lastly, the policy proposals for incubating program support and future research directions along with the limitation are suggested.

The Hydraulic Characteristics of Liquid Shotcrete Accelerators within Cement System (시멘트 계에서 액상 숏크리트용 급결제의 수화 특성에 관한 연구)

  • Shin Jin-Yong;Kim Jae-Young;Hong Ji-Sook;Suh Jeong-Kwon;Rho Jae-Seong
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.1011-1018
    • /
    • 2005
  • The influence of liquid shotcrete accelerators(alkali aluminate, two types of alkali-free) was investigated. Comparing to the existing alkali aluminate accelerator, new alkali-free accelerator, AF2, shortened initial and final setting of cement system, and after curing for 1 day compressive strength was analogous with others. On the other hand, compressive strength of specimen cured for 12 hour was the highest by the addition of alkali aluminate accelerator, but final strength was the lowest by that. But compressive strengths of AF1, AF2 were similar to Plain up to 28day. Further from XRD(X-Ray Diffractometer) and DSC(Differential Scanning Calorimeter) analyses, we confirmed that setting promoted by alkali aluminate was mainly because of Ca(OH)2(calcium hydroxide), but the accelerating behavior of alkali-free was influenced by the needle-like ettringite$(6CaO{\cdot}Al_2O_3{\cdot}3SO_3{\cdot}32H_2O)$ crystal.

Design for Radiotherapy Room with High Density Shielding Block (고 강도 차폐벽돌을 이용한 방사선치료실의 차폐설계)

  • Suh Chang Ok;Kim Gwi Eon;Chu Sung Sil
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.247-254
    • /
    • 2004
  • According to developing high energy linear accelerators and treatment methods, like (3 dimensional conformal radiotherapy (3D-CRT), intensity modulated radiotherapy (IMRT), many radiotherapy centers are replacing older linear accelerators with new higher technical machines. This often presents a shielding problem as the designed shield for the existing rooms is not adequate for the higher technical machines. Additional shielding in limited existing space becomes necessary. We are replacing older brachytherapy room with new higher technical linear accelerator for IMRT. This room is not adequate for the IMRT machine without additional shielding design. The logical development of optimum structural shielding designs with concrete and high density shielding blocks are presented. We obtained following results by comparison between the pre-calculating values and actual survey of completed LINAC installation. High density shielding blocks have more powerful radiation protection about 2 times.

  • PDF

Evaluation of the effect of blood contamination on the compressive strength of MTA modified with hydration accelerators

  • Oloomi, Kaveh;Saberi, Eshaghali;Mokhtari, Hadi;Mokhtari Zonouzi, Hamid Reza;Nosrat, Ali;Nekoofar, Mohammad Hossein;Dummer, Paul Michael Howell
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.3
    • /
    • pp.128-133
    • /
    • 2013
  • Objectives: This study was performed to evaluate the effect of blood contamination on the compressive strength (CS) of Root MTA (RMTA) modified with Calcium chloride ($CaCl_2$) and Disodium hydrogen phosphate ($Na_2HPO_4$) as setting accelerators over time. Materials and Methods: A total of 110 cylindrical specimens of RMTA were divided into 6 experimental groups as follows: Group1, RMTA; Group 2, RMTA modified with $CaCl_2$ (RMTA-C); Group 3, RMTA modified with $Na_2HPO_4$ (RMTA-N); Group 4, RMTA contaminated with blood; Group 5, RMTA-C contaminated with blood; Group 6, RMTA-N contaminated with blood. The CS of specimens in all groups was evaluated after 3 hr, 24 hr, and 1 wk. In the modified groups (groups 2, 3, 5, and 6) the CS of five specimens per group was also evaluated after 1 hr. Results: Blood contamination significantly reduced the CS of all materials at all time intervals (p < 0.05). After 3 hr, the CS of specimens in the RMTA groups (with and without blood contamination) was significantly lower than those in the RMTA-C and RMTA-N groups (p < 0.05). The CS values were not significantly different at the other time intervals. In all groups, the CS of specimens significantly increased over time (p < 0.05). Conclusions: Blood contamination decreased the CS of both original and accelerated RMTA.

Implementation and Performance Evaluation of PCI express on Xilinx FPGA (Xilinx FPGA용 PCI express 구현 및 성능 분석)

  • Lee, Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.12
    • /
    • pp.1667-1674
    • /
    • 2018
  • Recently, speeding up real time calculation using the specialized hardware accelerator is often used in the various engineering and science area, and the accelerators are required to include PCI express interconnection between FPGA and a host computer. The implementation of the high speed PCIe for the multi-giga bytes per second transmission is one of the most difficult issue in the development of the accelerators. There are several commercialized IP solutions and research results in the literature, but these solutions are required extra cost and design period to analyze the detailed implementation method. For the hardware accelerator on Xilinx FPGA, utilizing Xilinx's XDMA PCIe IP, which is provided without extra charge, can be the best solution in terms of the development period and cost. Consequently, this paper presents the evaluation system on Zynq-7000 FPGA and Windows 10 host computer, and analyze the performance of the PCIe IP with various configuration parameters.