• Title/Summary/Keyword: acceleration analysis

Search Result 2,602, Processing Time 0.033 seconds

Parameter Calibration of Car Following Models Using DGPS DATA (DGPS 수신장치를 활용한 차량추종 모형 파라미터 정산)

  • Kim, Eun-Yeong;Lee, Cheong-Won;Kim, Yong-Jin
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.3 s.89
    • /
    • pp.17-27
    • /
    • 2006
  • Car following model is a theory that examines changes of condition and interrelationship of acceleration deceleration. headway, velocity and so on closely based on the hypothesis that the Posterior vehicle always follows the preceding vehicle. Car following mode) which is one of the research fields of microscopic traffic flow was first introduced in 1950s and was in active progress in 1960s. However, due to the limitation of data gathering the research depression was prominent for quite a while and then soon was able to tune back on track with development in global positioning system using satellite and generalization of computer use. Recently, there has been many research studies using reception materials of global Positioning system(GPS). Introducing GPS technology to traffic has made real time tracking of a vehicle position possible. Position information is sequential in terms of time and simultaneous measurement of several vehicles in continuous driving is also practicable. Above research was focused on judging whether it is feasible to overcome the following model research by adopting the GPS reception device that was restrictively proceeded due to the limitation of data gathering. For practical judgment, we measured the accuracy and confidence level of the GPS reception devices material by carrying out a practical experiment. Car following model is also being applied in simulations of traffic flow analysis, but due to the difficulty of estimating parameters the basis of the above result. it is our goal to produce an accurate calibration of car following model's parameters that is suitable in this domestic actuality.

Analysis of Characteristics of Vertical Response Spectrum of Ground Motions from Domestic Earthquakes (국내 관측자료를 이용한 수직 응답스펙트럼 특성 분석)

  • Kim, Jun-Kyoung;Hong, Seung-Min;Park, Ki-Jong
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.3
    • /
    • pp.227-234
    • /
    • 2010
  • The vertical response spectra using the observed ground motions from the recent more than 30 macro earthquakes were analysed and then were compared both to the seismic design response spectra (Reg Guide 1.60), applied to the domestic nuclear power plants, and to the Korean Standard Design Response Spectrum for general structures and buildings (1997). 176 vertical ground motions, without considering soil types, were used for normalization with respect to the peak acceleration value of each ground motion. The results showed that response spectrum had strong dependency on epicentral distance. The results also showed that the vertical response spectra revealed much higher values for frequency bands above 5~7 Hz than Reg. Guide (1.60). The results were also compared to the Korean Standard Response Spectrum for the 3 different soil types and showed that the vertical response spectra revealed much higher values for the frequency bands below 0.2 second (5 Hz) than the Korean Standard Response Spectrum (SD soil condition). These frequency-dependent spectral values could be related to the characteristics of the domestic crustal attenuation and the effect of each site amplification. However, through the qualitative improvements and quantitative enhancement of the observed ground motions, the conservation of vertical seismic design response spectrum should be considered more significantly for the frequency bands above 5 Hz.

Development of Wireless Ambulatory System Measuring 3-D Motion as Podiatric Diagnosis (족부 진단용 3차원 움직임 측정을 위한 무선 이동형 시스템 개발)

  • Kim, Jin-Ho;Kim, Hwa-In;Kim, Dong-Wook;Won, Yong-Gwan;Kim, Jung-Ja
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.5B
    • /
    • pp.502-510
    • /
    • 2011
  • In this research, a wireless movable systems is introduced that is applicable for real-world clinical examination in order to resolve the inconvenience of wired motion analysis system which uses markers by measuring more accurately the angle of the 3D motion. The system is composed of bluetooth data transmission and 6 DOF inertial measurement system that is composed of 3-axis acceleration and 3-axis gyroscope. The samples were collected from 10 feet of 5 young children who were confirmed as patients having flat feet and achilles tendonitis by podiatric expert in pediatrics, and the validity of the system was evaluated by comparison with the opinion by the expert using the EMG data and the data measured by the developed system. ROM of ankle was measured by the difference between the maximum and the minimum peaks of 3-axis values (pitch, roll and yaw) measured at lateral malleolus bone, and based on this measured value, the eversion rate became relatively higher as flat feet state become worse, which is equivalent to the opinion from the podiatric experts. It was shown that there is a relation between the certain muscle activities and the abnormal motion of foot caused by disease.

Bioequivalence of Bucilin Tablet to Rimatil Tablet (Bucillamine 100 mg) (리마틸 정(부시라민 100 mg)에 대한 부시린 정의 생물학적 동등성)

  • Cho, Hea-Young;Lee, Moon-Seok;Oh, In-Joon;Kim, Dong-Hyun;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.31 no.2
    • /
    • pp.125-130
    • /
    • 2001
  • Bucillamine is a novel cysteine derivative with two free intramolecular sulfhydryl groups, and has a preventive and therapeutic effect on adjuvant arthritis, suggesting its antirheumatic action. With respect to the effect on the immune system, bucillamine-exerted such immunoregulating actions are to nomalize an excessive reduction or acceleration in immune reaction. It is useful not only in patients with early stage of rheumatoid arthritis (RA) but also in those with active RA retained for more than 10 years. The purpose of the present study was to evaluate the bioequivalence of two bucillamine tablets, $Rimatil^{TM}$ (Chong Kun Dang Pharmaceutical Co., Ltd.) and $Bucilin^{TM}$ (Kuhn Il Pharmaceutical Co., Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). Eighteen normal male volunteers, $23.67{\pm}2.09$ years in age and $65.03{\pm}6.73\;kg$ in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After three tablets containing 100 mg of bucillamine per tablet were orally administered, blood was taken at predetermined time intervals and the concentrations of bucillamine in serum were determined using GC/MS with mass selective detector. Pharmacokinetic parameters such as $AUC_t$, $C_{max}\;and\;T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters. The results showed that the differences in $AUC_t$, $C_{max}\;and\;T_{max}$ between two tablets were -0.29%, -3.20% and 8.22%, respectively, when calculated against the $Rimatil^{TM}$ tablet. The powers $(1-{\beta})$ for $AUC_t\;and\;C_{max}$ were 84.31 % and 91.16%, respectively. Minimum detectable differences $({\Delta})$ at ${\alpha}=0.10$ and $1-{\beta}=0.8$ were less than 20% (e.g., 18.58% and 16.51% for $AUC_t\;and\;C_{max}$, respectively). The 90% confidence intervals were within ${\pm}20%$ (e.g.,$-12.77{\sim}12.20$ for $AUC_t$ and $-14.30{\sim}7.90$ for $C_{max}$). Two parameters met the criteria of KFDA for bioequivalence, indicating that $Bucilin^{TM}$ tablet is bioequivalent to $Rimatil^{TM}$ tablet.

  • PDF

A Numerical Study on an Optimum Design of a Hybrid Collector Coupled with the Principle of Cyclone, Baffle and Bag-Filter (싸이클론과 배플 및 백필터 원리를 결합한 하이브리드형 집진기의 최적화 설계를 위한 수치해석)

  • Hong, Sung-Gil;Jung, Yu-Jin;Lim, Ki-Hyuk;Yoo, Jeong-Kun;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.983-989
    • /
    • 2013
  • The current research reviewed the design conditions that would maximize the efficiency of the hybrid collector that combines in one unit "cyclone-inertial impaction-bag filter". The computational analysis for the shape of cyclone entry predicts that a design that installs the guide vane at the entry of the tangential type cyclone brings a high-rpm and powerful vortex, very effective in promoting the deflection of coarse particles from the streamline at the cyclone. As the lower part of the cyclone is venturi-shaped, however, a strong flow downward of 4 to 5 m/sec persists through the lower part of the hopper, revealing the likely reentrainment of collected dust. And the removal of the venturi at the lower part of the cyclone would solve the problem of the reentrainment of collected dust. The acceleration of the flow velocity through the adjustment of the gap of the collision baffle would increase the effect of collision, but as the interference with the dust separation is expected, the original design should be kept for the baffle.

Seismic Fragility of Sewage Pipes Considering Site Response in Korean, Seoul Site (국내 서울지역의 부지응답해석을 고려한 하수도관의 지진취약도)

  • Shin, Dea-Sub;Kim, Hu-Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.33-38
    • /
    • 2017
  • The number of damaged lifeline structures have been increasing with urban acceleration under earthquakes. To predict the damage, damage mitigation technology of lifeline structures should be analyzed using damage prediction technology. Therefore, in this paper, the degree of the fragility of structures under an earthquake was evaluated stochastically through an evaluation of the seismic fragility. The aim was to develop damage prediction technology of sewage pipes among the lifeline facilities. The site response was performed using the data from 158 boreholes in Seoul and 7 real earthquake waves to determine the responses in real urban areas. The seismic fragility was deduced through a total of 29822 time history analysis. In addition, sewer pipes were evaluated and the persisting period was passed by applying the research results of strength reduction which is due to sulphate erosion. As a result, the difference in failure probability between 300 and 800 with the smaller diameter of the representative pipes was approximately double and the size of the pipes has a significant effect on the seismic fragility function. Moreover, the failure probability of a seismic load increases by up to 10 fold as the strength reduction rate increases. The results of this study can be used as a means of predicting the damage and countermeasures of sewer pipes and might be reflected in the seismic design of underground facilities.

Evaluation of Structural Safety of Polyethylene Boats by Drop Test Method (낙하시험에 의한 폴리에틸렌 보트의 구조 안전성 평가)

  • Lee, Sung-Riong;Kang, Gyung-Ju;Cho, Seok-Swoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.531-542
    • /
    • 2017
  • The structural safety of small craft, such as steel ships and FRP ships, can be estimated using the measurement test of the hull plate thickness or the longitudinal bending strength test. A polyethylene boat is made using inexpensive HDPE and can be mass produced. The structural safety of a polyethylene boat cannot be guaranteed because a polyethylene boat hull is notspecified in the KR technical rules. The inspection procedure of sailing yachts and pleasure boats and drop test method of ISO standard 12215-5 propose the structural strength required for small crafts as the drop test height. Therefore, in this study, the drop test of a polyethylene boat hull was carried out based on the inspection procedure of a sailing yacht and pleasure boat and the drop test method of ISO standard 12215-5. The drop load was acquired by the drop acceleration ofa boat hull. Structural analysis and safety of a polyethylene boat were performed by the drop load and allowable stress criteria. The calculation results of the hull plate thickness by structural design specification of ISO standard 12215-5 showed that polyethylene boat hull was more than two times thicker than a steel ship hull and the boat hull determined by the inspection procedure of sailing yacht and pleasure boat and drop test method of ISO standard 12215-5 was more than 1.2 times thicker than the boat hull determined by structural design specification of ISO standard 12215-5. Therefore, inspection procedure of sailing yachts and pleasure boats and drop test method of ISO standard 12215-5 was much more conservative than the structural design specification of ISO standard 12215-5 and could be used as the structural design method of a polyethylene boat.

Assessment of Train Running Safety, Ride Comfort and Track Serviceability at Transition between Floating Slab Track and Conventional Concrete Track (플로팅 슬래브궤도와 일반 콘크리트궤도 접속구간에서의 열차 주행 안전, 승차감 및 궤도 사용성 평가)

  • Jang, Seung-Yup;Yang, Sin-Chu
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.1
    • /
    • pp.48-61
    • /
    • 2012
  • It is of great importance to assure the running safety, ride comfort and serviceability in designing the floating slab track for mitigation of train-induced vibration. In this paper, for this, analyzed are the system requirements for the running safety, ride comfort and serviceability, and then, the behavior of train and track at the floating slab track including the transition zone to the conventional concrete slab track according to several main design variables such as system natural frequency, arrangement of spring at transition, spacing of spring isolators, damping ratio and train speed, using the dynamic analysis technique considering the train-track interaction. The results of this study demonstrate that the discontinuity of the support stiffness at the transition results in a drastic increase of the dynamic response such as wheel-rail interaction force, rail bending stress and rail uplift force. Hence, it is efficient to decrease the spacing of springs or to increase the spring constants at the transition to obtain the running safety and serviceability. On the other hand, the vehicle body acceleration as a measure of ride comfort is little affected by the discontinuity of the stiffness at the transition, but by the system tuning frequency; thus, to obtain the ride comfort, it is of great significance to select the appropriate system tuning frequency. In addition, the effects of damping ratio, spacing of springs and train speed on the dynamic behavior of the system have been discussed.

Comparison of Newton's and Euler's Algorithm in a Compound Pendulum (복합진자 모형의 뉴튼.오일러 알고리즘 비교)

  • Hah, Chong-Ku
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.1-7
    • /
    • 2006
  • The Primary type of swinging motion in human movement is that which is characteristic of a pendulum. The two types of pendulums are identified as simple and compound. A simple pendulum consist of a small body suspended by a relatively long cord. Its total mass is contained within the bob. The cord is not considered to have mass. A compound pendulum, on the other hand, is any pendulum such as the human body swinging by hands from a horizontal bar. Therefore a compound pendulum depicts important motions that are harmonic, periodic, and oscillatory. In this paper one discusses and compares two algorithms of Newton's method(F = m a) and Euler's method (M = $I{\times}{\alpha}$) in compound pendulum. Through exercise model such as human body with weight(m = 50 kg), body length(L = 1.5m), and center of gravity ($L_c$ = 0.4119L) from proximal end swinging by hands from a horizontal bar, one finds kinematic variables(angle displacement / velocity / acceleration), and simulates kinematic variables by changing body lengths and body mass. BSP by Clauser et al.(1969) & Chandler et al.(1975) is used to find moment of inertia of the compound pendulum. The radius of gyration about center of gravity (CoG) is $k_c\;=\;K_c{\times}L$ (단, k= radius of gyration, K= radius of gyration /segment length), and then moment of inertia about center of gravity(CoG) becomes $I_c\;=\;m\;k_c^2$. Finally, moment of inertia about Z-axis by parallel theorem becomes $I_o\;=\;I_c\;+\;m\;k^2$. The two-order ordinary differential equations of models are solved by ND function of numeric analysis method in Mathematica5.1. The results are as follows; First, The complexity of Newton's method is much more complex than that of Euler's method Second, one could be find kinematic variables according to changing body lengths(L = 1.3 / 1.7 m) and periods are increased by body length increment(L = 1.3 / 1.5 / 1.7 m). Third, one could be find that periods are not changing by means of changing mass(m = 50 / 55 / 60 kg). Conclusively, one is intended to meditate the possibility of applying a compound pendulum to sports(balling, golf, gymnastics and so on) necessary swinging motions. Further improvements to the study could be to apply Euler's method to real motions and one would be able to develop the simulator.

The Kinematic analysis of the third Hurdling motions of The 110m Hurdles Elite (엘리트 110m 허들선수의 세 번째 허들링 동작에 관한 운동학적 분석)

  • Lee, Jung-Ho;Park, Young-Jin;Ryu, Jae-Kyun;Kim, Jong-In
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.31-39
    • /
    • 2008
  • The purposes of this study were to compare and analyze the world elite hurdler and the domestic hurdler 3-D kinematic and kinetic techniques about hurdling motion in the 110m hurdles. After analyzing variables in the 110m hurdle run the following conclusions were obtained; In a preparation phase, the domestic hurdler came out running more 0.13m then world elite hurdler from grounding to taking off in the height of center of gravity and the distance by 1.04m. In a flight phase, the domestic hurdler came out taking off 0.33m less then world elite hurdler from taking off to flight peak in the height of center of gravity and the distance by 1.63m. In a flight peak phase, domestic hurdler came out landing more 0.37m then world elite hurdler by 159m. More over, during the hurdling, the horizontal velocity of center of gravity came out decreasing from taking off to landing with domestic hurdler by 0.75m/s. the take off percentage and the landing percentage is 53:47. In a acceleration phase, domestic hurdler came out going slower 0.54m/s than world elite hurdler from landing in the horizontal velocity of center of gravity by 8.78m/s.