• 제목/요약/키워드: ac-conductivity

검색결과 183건 처리시간 0.031초

리튬 폴리머전지용 PMMA/PVDF계 고분자 전해질의 이온 전도 특성 (Ion Conduction Properties of PMMA/PVDF based Polymer Electrolyte for Lithium Polymer Battery)

  • 이재안;김종욱;구할본;이헌수;손명모
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.347-350
    • /
    • 2000
  • The purpose of this study is to research and develop solid polymer electrolyte(SPE) for Li polymer battery. The temperature dependence of conductivity, impedance spectroscopy and electrochemical properties of PMMA/PVDF electrolytes as a function of a mixed ratio were reported for PMMA/PVDF based polymer electrolyte films, which were prepared by thermal gellification method of preweighed PMMA/PVDF, plasticizer and Li salt. The ion conductivity of PMMA/PVDF electrolytes was 10$\^$-3/S/cm, which may be applicable to a constituent of lithium secondary battery. 5PMMA20PVDFLiC1O$_4$PC$\sub$8/EC$\sub$8/ electrolyte remains stable up to 5V vs. Li/Li$\^$+/. Steady state current method and AC impedance were used for the determination of transference numbers in PMMA/PVDF electrolyte film. The transference number of 5PMMA20PVDFLiC1O$_4$PC$\sub$8/EC$\sub$8/ electrolyte is 0.55.

  • PDF

나노/마이크로 에폭시 복합체의 전기적, 열적특성 분석 (Analysis of electrical, thermal characteristic of Nano/Micro Epoxy composite)

  • 정의환;윤재훈;임기조;정수현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.99-99
    • /
    • 2010
  • Polymer nanocomposite has been attracting much attention as a new insulation material, since homogeneous dispersion of nm-sized inorganic fillers can improve various properties significantly. In this paper, various kinds of epoxy based nanocomposites were made and AC breakdown strength of Nano-TiO2 and micro-silica filler mixture of epoxy based composites were studied by sphere to sphere electrode. Moreover, nano- and micro-filler combinations were adopted as an approach toward practical application of nanocomposite insulation materials. Nano-TiO2 particle size is about 10nm and composites ratio was resin (100) : hardener (82) : accelerator (1.5). AC breakdown test was performed at room temperature (25 [$^{\circ}C$], 80 [$^{\circ}C$] and 100 [$^{\circ}C$] in the vicinity of Tg (90[$^{\circ}C$]). And thermal conductivity were measured by ASTM-D5470.

  • PDF

DC 전압이 유입변압기 절연시스템에 미치는 영향에 관한 연구 (Study on the effect of DC voltage in oil-immersed transformer insulation system)

  • 장효재;김용한;석복렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1552-1553
    • /
    • 2011
  • The HVDC transformer which is one of the main equipments for HVDC(High Voltage Direct Current) electric power transmission systems is exposed to not only AC voltage but also the inflowing DC voltage which comes from the DC-AC converter systems. Therefore, the HVDC transformer insulation system is required to withstand the electric field stress under AC, DC and DC polarity reversal conditions. However the electric field distributions under those conditions are different because the AC electric field and DC electric field are governed by permittivity and conductivity, respectively. In this study, the changes of electric potential and electric field of conventional AC transformer insulation system under DC polarity reversal test condition were analyzed by FEM(Finite Element Method). The DC electric field stress was concentrated in the solid insulators while the AC electric field stress was concentrated in the mineral oil. In addition, the electric stress under that condition which is affected by the surface charge accumulation at the interfaces between insulators was evaluated. The stress in some parts could be higher than that of AC and DC condition, during polarity reversal test. The result of this study would be helpful for the HVDC transformer insulation system design.

  • PDF

3-${\omega}$ 방법을 이용한 다중벽 탄소나노튜브 나노유체의 침전 안정성 및 열전도계수 측정에 관한 실험적 연구 (Stabilization and thermal conductivity measurement of MWCNT nanofluids by using the $3-{\omega}$ method)

  • 오동욱;이준식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2171-2176
    • /
    • 2007
  • The 3-omega (3-${\omega}$) method is utilized to measure the thermal conductivity of nanofluids. A metal line heater on a silicon nitride membrane bridge structure is microfabricated by a bulk silicon etching method. Localized measurement of the thermal conductivity within the nanofluids droplet is possible by the fabricated 3-${\omega}$ sensor. Time varying AC temperature amplitudes and thermal conductivities are measured to check the stability of the nanofluids containing multi-wall carbon nanotubes (MWCNTs). Stabilities of MWCNT nanofluids prepared with different chemical treatments are compared. Acid treated MWCNT showed best dispersion stability in water while MWCNTs dispersed in water with surfactants such as Gum Arabic and Sodium dodecyl benzene sulfate showed clear sign of gravity dependence.

  • PDF

리튬 폴리머전지용 PAN/PVDF계 고분자 전해질의 리튬 이온 거동 (Behavior of $Li^{+}$ in PAN/PVDF based Polymer Electrolyte for Lithium Polymer Battery)

  • 이재안;김상기;김종욱;구할본;박계춘
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.540-543
    • /
    • 2000
  • The purpose of this study is to research and develop solid polymer electrolyte(SPE) for Li polymer battery. The temperature dependence of conductivity, impedance spectroscopy and electrochemical properties of PAN/PVDF electrolytes as a function of a mixed ratio were reported for PAN/PVDF based polymer electrolyte films, which were prepared by thermal gellification method of preweighed PAN/PVDF, plasticizer and Li salt. The conductivity of PAN/PVDF electrolytes was $10^{-3}$S/cm. $PAN_{10}$$PVDF_{10}$$LiClO_4$$PC_{5}$$EC_{5}$ electrolyte has the better conductivity compared to others. The interfacial resistance behavior between the lithium electrode and PAN/PVDF based polymer electrolyte has also been investigated and compare with that between the lithium electrode and the PAN/PVDF based polymer electrolyte.

  • PDF

Preparation, Characterizations and Conductivity of Composite Polymer Electrolytes Based on PEO-LiClO4 and Nano ZnO Filler

  • ElBellihi, Abdelhameed Ahmed;Bayoumy, Wafaa Abdallah;Masoud, Emad Mohamed;Mousa, Mahmoud Ahmed
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권9호
    • /
    • pp.2949-2954
    • /
    • 2012
  • Nano ZnO with an average size of 8 nm was prepared by thermal decomposition of zinc oxalate at $450^{\circ}C$. A series of based composite polymer electrolyte PEO-$LiClO_4$ and nano ZnO as a filler have been synthesized using solution cast technique, with varying the filler ratio systematically. XRD, DSC and FTIR studies have been conducted to investigate the structure and interaction of different groups in the composite polymer electrolyte. Effect of nano ZnO ceramic filler concentration on the structure of composites and their electrical properties (DC-conductivity, AC-conductivity, dielectric constant, dielectric loss and impedance) at different frequencies and temperatures was studied. Melting temperature ($T_m$) of PEO decreased with the addition of both $LiClO_4$ salt and nano ZnO filler due to increasing the amorphous state of polymer. All composite samples showed an ionic conductivity. The maximum room temperature ionic conductivity is found for $(ZnO)_{0.5}(PEO)_{12}(LiClO_4)$ composite sample. All the results are correlated and discussed.

망간이 혼입된 층상구조 Na1.9Li0.1Ti3O7 세라믹스의 유전율 ‒ 분광법과 교류 전도도 측정 연구 (Dielectric-Spectroscopic and ac Conductivity Investigations on Manganese Doped Layered Na1.9Li0.1Ti3O7 Ceramics)

  • Pal, Dharmendra;Pandey, J.L.;Shripal
    • 대한화학회지
    • /
    • 제53권1호
    • /
    • pp.42-50
    • /
    • 2009
  • 유전율-분광법과 교류 전도도 측정 연구를 망간이 혼입된 층상구조의 $Na_{1.9}Li_{0.1}Ti_3O_7$에 시도하였다. 373-723K 온도와 100Hz-1MHz 주파수 영역에서 loss 탄젠트 (Tan$\delta$), 상대적 유전율 ($\varepsilon_{r}$) 그리고 교류 전도 도 ($\sigma_{ac}$)의 의존성을 혼입 유도체들에 대하여 조사하였다. 다양한 전도도 메커니즘이 존재하는데 MSLT-1과 MSLT-2의 경우에는 낮은 온도영역에서 전자에 의한 전도도를 보인다. MSLT-3의 경우에는 금지된 층간 이온 전 도도가 전자 전도도와 함께 존재한다. 이러한 층간 이온 전도도는 모든 혼입 유도체들에 대하여 중간 온도 영역에 존재한다. 가장 높은 온도 영역에서는 MSLT-1과 MSLT-2의 경우에는 이온 전도도와 polaron에 의한 전도도가 존재하고 MSLT-3에 대하여는 이온 전도도 만이 존재한다. 망간이 혼입된 층상구조의 $Na_{1.9}Li_{0.1}Ti_3O_7$에서 Loss 탄젠트 (Tan$\delta$)는 전자 전도도와 쌍극자의 위치, 그리고 공간 전하 분극화에 기인한다. 상대적 유전율의 증가는 층간 에 쌍극자 수의 증가에 기인하고 반면 상대적 유전율의 감소는 높은 혼입율에 따른 누전 전류의 증가에 기인한다.

유리 용융물의 고온에서 전기 전도도 측정 (Measurement of Electrical Conductivity of Glass Melter at High Temperature)

  • 김태삼;길대섭;정헌생;강은희;윤석승
    • 분석과학
    • /
    • 제13권6호
    • /
    • pp.775-780
    • /
    • 2000
  • 고온에서 용융된 유리의 전기 전도도를 측정하였다. 유리의 전기 전도도는 유리의 물성 연구와 유리 제조 공정에서 공정 조건을 조절하기 위하여 중요하게 사용되는 용융물의 물리적 성질이다. 그러나 고온의 용융물은 수용액에서 사용하는 전도도 셀을 사용할 수 없기 때문에 고온의 전도도를 직접 측정할 수 있는 백금 도가니와 막대로 구성된 전도도 셀을 구성하고 유리 용융액의 전도도를 측정하였다. 전도도 셀의 상수를 구하기 위하여 융융 유리와 전도도가 유사하도록 KCl의 수용액을 사용하였다. 교류 1 kHz의 사인파 발생기와 연산증폭기로 구성된 회로를 사용하고 용액의 전도도에 따른 출력 전위를 측정하여 전기 전도도와 셀 상수를 구하였으며, 고온에서 사용하기에 적합한 전도도 셀 형태를 결정하였다. 측정하는 Cell의 크기와 용기의 크기, Cell이 들어가는 깊이, 전극의 형태를 달리하여 측정한 결과를 비교하였다. 시험 측정한 붕규산염 유리의 고온 용융물의 전기 전도도는 $1,450^{\circ}C$에서 $0.053{\Omega}^{-1}cm^{-1}$이었다.

  • PDF

가소제 혼합비에 따른 PAN/PVDF계 고분자 전해질의 이온 전도 특성 (Conductivity of PAN/PVDF based Polymer Electrolyte as a Function of Plasticizer Mixed Ratio)

  • 이재안;김종욱;구할본
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.261-264
    • /
    • 2000
  • The purpose of this study is to research and develop solid polymer electrolyte(SPE) for Li polymer battery. This paper describes temperature dependence of conductivity, impedance spectroscopy, electrochemical properties of PAN/PVDF electrolytes as a function of a mixed ratio. PAN/PVDF based polymer electrolyte films were prepared by thermal gellification method of preweighed PAN/PVDF, plasticizer and Li salt. By adding PVDF and as a function of plasticizer mixed ratio to PAN-LiClO4 electrolyte, its conductivity was higher than that of PAN-$LiClO4_4$ electrolyte. The conductivity of PAN/PVDF electrolytes was $10^{-3}S/cm$. $10PAN10PVDFLiClO_4PC_5EC_5$ electrolyte shows the better conductivity of the others. Steady state current method and ac impedance used for the determination of transference numbers in PAN/PVDF electrolyte film. The transference number of $10PAN10PVDFLiClO_4PC_5EC_5$ electrolyte is 0.45.

  • PDF

낙뢰손상방지를 위한 전도성 나노입자 코팅에 의한 탄소섬유 복합재료의 전기전도도 향상 연구 (Improved Electrical Conductivity of CFRP by Conductive Nano-Particles Coating for lightning Strike Protection)

  • 하민석;권오양;최흥섭
    • Composites Research
    • /
    • 제23권1호
    • /
    • pp.31-36
    • /
    • 2010
  • 본 연구는 탄소섬유강화플라스틱(CFRP) 복합재료로 제작된 항공기 등 구조물의 낙뢰에 의한 손상을 방지하기 위하여 전도성 은나노입자를 탄소섬유에 코팅한 후 에폭시 수지로 함침함으로써 CFRP의 전기전도도를 향상시키는 방법에 대한 것이다. 전기전도도 측정은 4점측정법을 통해 저항값을 측정하고 이를 전기전도도 값으로 변환하였으며, 나노입자 코팅 상태와 전기전도도의 변화를 관찰하였다. 또한 SEM과 EDS를 통해 탄소섬유 표면에 코팅된 은나노입자의 존재와 전기적 네트워크가 형성된 것을 확인하였다. 결과로써 일반 CFRP의 약 3배 이상의 전기전도도를 얻을 수 있었다.