• 제목/요약/키워드: abutment length

검색결과 108건 처리시간 0.027초

온도변화에 따른 무신축이음 강상자형 교량의 거동 분석 (Behavior of Jointless Bridge of Steel Box Girder Type Due to Temperature Change)

  • 조남훈;이성우
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.95-102
    • /
    • 1997
  • Jointless bridge is a new construction method applicable to bridge of short length. In the jointless bridge expansion of superstructure due to thermal effect was absorbed in the flexible pile-type abutment in stead of expansion joint in the conventional bridges. By removing expansion joint, it retards deterioration and extends life time of bridge. In this paper, jointless bridge of steel box girder type was studied through finite element analysis. Stress variations of superstructure and pile due to thermal effect was studied for the two span continuous integral bridge of 80m length and the results of analysis was presented.

  • PDF

임플란트 고정체의 platform의 크기에 따른 유한요소법적 응력분석 (FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO PLATFORM WIDTH OF FIXTURE)

  • 정경민;정재헌;정승미
    • 대한치과보철학회지
    • /
    • 제41권5호
    • /
    • pp.674-688
    • /
    • 2003
  • Statement of Problem : With increasing demand of the implant-supported prosthesis, it is advantageous to use the different platform width of the fixture according to bone quantity and quality of the patients. Purpose : The purpose of this study was to assess the loading distributing characteristics of two implant designs according to each platform width of fixture, under vertical and inclined loading using finite element analysis. Material and method : The two kinds of finite element models were designed according to each platform width of future (4.1mm restorative component x 11.5mm length, 5.0mm wide-diameter restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction, 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction and 200N at the buccal cusp in a 300 transverse direction individually Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. Results : The stresses were concentrated mainly at the cortex in both vertical and oblique load ing but the stresses in the cancellous bone were low in both vertical and oblique loading. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading. Increasing the platform width of the implant fixture decreased the stress in the supporting bone, future and abutment screw. Increased the platform width of fixture decreased the stress in the crown and platform. Conclusion : Conclusively, this investigation provides evidence that the platform width of the implant fixture directly affects periimplant stress. By increasing the platform width of the implant fixture, it showed tendency to decreased the supporting bone, future and screw. But, further clinical studies are necessary to determine the ideal protocol for the successful placement of wide platform implants.

임플란트를 이용한 국소의치 수복 (Implants in conjunction with removable partial denture)

  • 김성균;유수연;박인필;이주희
    • 대한치과의사협회지
    • /
    • 제49권2호
    • /
    • pp.77-84
    • /
    • 2011
  • The benefits of implant supported overdenture are readily apparent for the fully edentulous patients and have been well documented, however, there is deficiency of the studies regarding the combination of implants with removable partial dentures for partially edentulous patients. The purpose of this article is to review the literature concerning implants with removable partial dentures and evaluate the evidence for this clinical approach. Through many clinical case reports and studies we have searched from a broad variety of journals, we present the six considerations needed to contemplate respecting implants with removable partial denture in partially edentulous patients. First, the connection between abutment tooth and removable partial denture has to be rigid and the link between implant and removable partial denture should be hinged. Second, a mesial rest acts better in the point of force distribution for distal extension removable partial denture and splinting between implants is also a favorable choice. Third, T bar has an advantage for implants which are used as abutments in distal extension removable partial denture. Forth, as we all known functional impression is better way to reproduce movement for distal extension removable partial denture. Fifth, indirect retainer and guiding plane on the proximal surfaces of terminal abutment teeth are important in preventing denture base lifting. Sixth, implants in conjunction with removable partial denture is superior in the esthetic and phonetic as well as cost-effective point of view. We also suggest that which place we should install implants for force distribution and which diameter and length of implants should be used. in this review article, we recommend to locate the implant near of the abutment tooth for esthetics or near of first molar position for good stress distribution. The diameter and length of implant also influence to stress distribution. When we compare to conservative partial denture, patients go for removable partial denture using implants due to convenience, better support and retention according to several studies. But it is true that we need to study more on this subject and collect long term follow up cases before we discuss on it. So it is enough to bring this subject into the surface of prosthetic treatment by this article.

인상채득이 가능한 치유지대주를 이용한 임플란트 인상채득의 정확성 (Accuracy of the healing abutment and impression coping combined system on implant impression)

  • 전경배;이두형;김정한;황준호;박현위;이규복
    • 대한치과보철학회지
    • /
    • 제53권2호
    • /
    • pp.105-110
    • /
    • 2015
  • 목적: 새롭게 개발된 인상채득이 가능한 치유지대주를 이용한 인상채득과 기존의 임프레션 코핑을 이용한 인상채득을 3차원적으로 비교함으로써 개발된 시스템의 정확성을 평가하였다. 재료 및 방법: 10명의 환자에서 구치부에 임플란트(SuperLine; Dentium, Seoul, Korea)를 식립 후 치유지대주(MyHealing; Raphabio Co., Seoul, Korea)를 연결하였다. 식립 3개월 후 보철물 제작을 위한 인상채득시 인상채득이 가능한 치유지대주를 이용한 transfer 방식과 기존의 인상용 코핑을 이용한 pick-up 방식으로 두 번 인상채득 후 각각 주모형을 제작하였다. 맞춤형 보철 지대주(Myplant; Raphabio Co., Seoul, Korea)를 제작하고 각각의 주모형에 체결 후 치과용 스캐너(Scanner S600; Zirkonzahn, South Tyrol, Italy)로 가상의 모형을 형성하였다. 3차원 분석 프로그램(Geomagic Qualify 12; Geomagic, Morrisville, NC, USA)을 이용하여 두 개의 가상의 모형을 중첩하여 지대주의 위치와 기울기의 차이를 분석하였다. 측정값은 Kruskal Wallis과 Mann-Whitney U test 방법을 통해 분석하였고, 유의수준은 0.05 로 설정하였다. 결과: 두 가지 인상법에 따른 지대주의 위치는 근원심 방향에서 0.032 mm, 협설측 방향에서 0.029 mm, 상하 방향에서 0.023 mm의 차이를 보였다. 기울기는 근원심 방향에서 $0.755^{\circ}$, 협설측 방향에서 $1.275^{\circ}$, 상하 방향에서 $0.420^{\circ}$의 차이를 보였다. 결론: 인상채득이 가능한 치유지대주를 이용한 인상채득 방식은 기존의 전통적인 인상용 코핑을 이용한 방식과 비교 시 0.032 mm 이내의 차이를 보였고 기존 논문과의 비교 시 유사한 수치이다.

공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구 (A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS)

  • 박철;임주환;조인호;임헌송
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

THE DIMENSIONAL CHANGE OF CAST IMPLANT BARS AFTER LABORATORY PROCEDURE

  • Kwon, Ji-Yung;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.354-361
    • /
    • 2007
  • Statement of Problems. The precision of fit between the bearing surfaces of implant abutments and the prosthesis framework has been considered fundamental to implant prosthodontic protocol. Purpose. The study aimed to investigate the effect of laboratory procedure on the dimensional accuracy of cast implant bars. Material and methods Thirty implant bars were fabricated on a metal master model. The gap distances were measured at the right implant abutment replica-gold cylinder interface after casting procedure. The bar length data of precasting and postcasting state were collected and analyzed. Results. The mean gap distance found after casting was $106.3{\mu}m$ for buccal side, $122.1{\mu}m$ for distal side and $117.1{\mu}m$ for the lingual side. The mean bar length was $17964.7{\mu}m$ at precasting measurement, $17891.6{\mu}m$ at postcasting measurement. The mean change of bar length was $-73.1{\mu}m$. Conclusion. Even though the techniques used in this study strictly followed the guidelines established in the literature, the 30 cast implant bars evaluated all yielded gap distances that were beyond acceptable accuracy. There was a statistically significant difference between precasting and postcasting bar length (P<0.01). There was a decreasing tendency in bar length after casting procedure. It was necessary to correct this dimensional change from laboratory procedure by some corrective methods.

Kimplant에 관한 3차원 유한요소 분석적 연구 (Three Dimensional Finite Element Analysis of Kimplant)

  • 김우영;장경수;김창회;김영수
    • 구강회복응용과학지
    • /
    • 제20권1호
    • /
    • pp.9-17
    • /
    • 2004
  • In this study, the biomechanical characteristics of Kimplant were compared with that of Branemark implant by using three dimensional finite element analysis. Two finite element models were fabricated by inserting each implant into the bone model. The bone model was designed to have 18mm height, 13mm width and 15mm length. The size of each implant was planned to have 4mm width and 10mm length. A 200N force was applied on the center of abutment top in three directions - vertical, horizontal and oblique. After analyzing the stresses of fixture and surrounding bone, following results were obtained. 1. There was similar stress distribution between the two models. 2. The magnitude of maximum principal stress on the implant was similar between the two models but the location of maximum principal stress on the implant was different. 3. The magnitude and location of maximum principal stress on the surrounding bone was similar between the two models.

콘크리트궤도부설 교량의 접속슬래브 허용변위한도에 관한 연구 (The Allowable Displacement Limit on the Approach Slab for a Railway Bridge with Ballastless Track)

  • 최진유;양신추;유진영;조현철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1149-1155
    • /
    • 2007
  • The transition area between a bridge and an earthwork is one of the weakest area of track because of the track geometry deterioration caused unequal settlement of backfill of abutment. In case of a ballastless track, the approach slab is installed to prevent the phenomenon. But, if there is occurred the inclined displacement on the approach slab by a settlement of the foundation or formation, the track is also under the inclined displacement. And this defect causes reducing the running stability of a vehicle, the riding comfort of passengers, and the deteriorations of track by excessive impact subjected to the track. In this study, parametric studies were performed to know what is the allowable displacement limit on the approach slab to avoid such a bad effect. The length and amount of unequal settlement of the approach slab was adopted as parameter for numerical analysis. And car body accelerations, variations of wheel force and rail stress and uplift force induced on a fastener clip are investigated. From the result, resonable settlement limits of an approach slab according to slab length was suggested.

  • PDF

단부격벽 일체형 PSC거더를 갖는 반일체식 교량의 시공성 연구 (Study on the Field Construction of Semi-Integral Bridge with PSC Girder Integrating End-Diaphragm)

  • 박종면;김진배;전성용;김충식;유성근;박중배;임정훈
    • 복합신소재구조학회 논문집
    • /
    • 제5권2호
    • /
    • pp.21-26
    • /
    • 2014
  • This paper introduces general concepts of jointless bridges and field construction case of semi-integral bridge with psc girder integrating end-diaphragm. The expansion joints need to satisfy thermal and safety conditions of bridges. General bridges with joints have some problems, which are frequently replacement cycle time from mechanical damage or unstable movement, maintenance cost and more. To solve these problems, Integral Abutment Bridges(IAB) have been applied overseas in the 1930s. In Korea, first IAB was constructed in the early 2000s and precast IAB systems was invented and applied lately. Kyungshin overpass bridge in Incheon is the Semi-IAB constructed, the span length is 2@35=70m and the width is 13.9m. The original plan was to use general joint bridge but design field changed with expectations for advanced economic estimation and maintenance. This changed method of B.I.B bridge construction provided not only workability, construction cost but also safety improvement at the same time.

경사하중에 따른 시멘트 유지형 임플란트 지지골의 유한요소법 응력 분포 (Finite Element Analysis of Stress Distribution on Supporting Bone of Cement Retained Implant by Oblique Loading)

  • 이명곤
    • 한국콘텐츠학회논문지
    • /
    • 제14권9호
    • /
    • pp.343-349
    • /
    • 2014
  • 본 연구는 치과 임상에서 사용하고 있는 시멘트 유지형 치과용 임플란트의 지지골 응력 분포 안정성을 확인하고자 시행하였다. 모델링과 유한요소 응력 분석은 유한요소 해석 프로그램인 Solidworks를 사용하였고, 시멘트 유지형 임플란트 시스템인 지대주와 고정체를 연결하는 지대주 나사를 20 Ncm 나사조임력에 의한 결합조건을 적용시킨 단관 모델을 제작하고, 설측에서 협측으로의 $45^{\circ}$ 경사로 100 N 크기 외부하중을 가하여 지지골 응력 분포 해석을 실시하였다. 경사하중에 따른 임플란트 고정체의 지지골 응력 크기와 분포를 파악하기 위한 유한요소법 분석을 통해 다음 결과를 얻었다. 고정체 직경, 길이의 조건에 관계없이 임플란트 고정체 상부와 골 접촉부인 치밀골에 응력이 집중되는 양상으로 나타났고, 고정체 길이 증가로 인한 응력 감소 폭보다 직경 증가로 인한 감소폭이 큰 것으로 나타났다 따라서 본 연구 결과는 지지골 형태 조건에 대하여 가능한 큰 직경의 고정체 사용이 효과적이라고 판단된다.