• Title/Summary/Keyword: absolute rotor position

Search Result 26, Processing Time 0.02 seconds

Analysis of the Encoder Composite Signal for a Absolute Position Detection of the Synchronous Motor (동기 전동기의 절대 위치 검출을 위한 엔코더 복합 신호의 분석)

  • Joo, Jae-Hun;Kim, Dong-Hyun;Choi, Jung-Keyng
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.5
    • /
    • pp.1018-1024
    • /
    • 2011
  • For the driving of the sinusoidal type permanent magnet synchronous motor with a maximum continuous torque, the 1200 delayed three phase sinusoidal current inputs which matched with the absolute rotor position are needed at the stator coil. Therefore, the detection of a absolute rotor position is required inevitably. And the right angle relationship between stator magnetic field and rotor magnetic field has to be preserved at a stator by this commutation action. The detection of a absolute position for the commutation can be made generally by the output signal analysis of the encoder attached at a motor shaft. The purposes of this study are to design signal processing logic circuits which could detect the absolute position of motor with a modern encoder system and generate the three reference wave for making sinusoidal current input at a stator coil.

Implementation of a Senseless Position Controller Capable of Multi-turn Detection in a Turret Servo System (터렛 서보 시스템에서 멀티-턴 검출이 가능한 센서리스 위치제어기 구현)

  • Cho, Nae-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.1
    • /
    • pp.37-44
    • /
    • 2021
  • This study is implemented as a sensor-less position controller capable of multi-turn detection to replace the expensive absolute encoder used in the turret servo system. For sensor-less control, the position information of the rotor is essential. For this, a magnetic flux estimator was implemented from the mathematical model of IPMSM used in the turret servo system. The position of the rotor and the angular velocity of the rotor were obtained using the rotor magnetic flux calculated from the magnetic flux estimator. Using the zero-crossing technique, one pulse was generated for each rotation of the estimated rotor magnetic flux to measure the number of multi-turns. Simulation and experiment results confirmed the usefulness of the proposed method.

A Design and Construction of Speed Encoder for High Performance Driving of SRM (SRM 고정도 구동을 위한 위치 및 속도엔코더의 설계 및 제작)

  • Kang, Yu-Jung;Oh, Seok-Kyu;Park, Sung-Jun;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1191-1193
    • /
    • 2001
  • In switched reluctance motor(SRM) drive, it is necessary to synchronize the stator phase excitation with the rotor position. Therefore, the rotor position information is essential. Usually, optical encoders or resolvers are used to provide the rotor position information. These sensors are expensive and are not suitable for high speed operation. This paper proposes a new encoder for high performance excitation control of SRM. The proposed encoder has complex structures of incremental and absolute encoder. An each phase inductance profile can be synchronized with 4-bit absolute position signal and incremental pulses are used for speed detection. Low cost and simple structure are possible.

  • PDF

Detection of Absolute Position of Robot Joint Using Incremental Encoders (증분형 엔코더를 이용한 로봇 관절의 절대위치 검출)

  • Lim, Jae Sik;Lee, Young Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.6
    • /
    • pp.577-582
    • /
    • 2015
  • This paper proposes an efficient detection of absolute position of a robot joint using two incremental encoders. We considers a robot joint comprising a motor, a reducer, two encoders, and a motor drive. An incremental(first) encoder provides motor's rotor position or input position of reducer while another incremental(second) encoder does output position of the reducer. A table is made where the relationship between the first and the second encoder counts is recorded. The key point is placed where the table is constructed: when a pulse occurs in the second encoder, there exists a corresponding unique count value of the first encoder. The absolute position is detected using the table by searching the second encoder position corresponding to the first encoder count value when a pulse occurs in the second encoder. The proposed method needs a small rotation, as just one second encoder's pulse angle, for the initial absolute position detection.

Analysis of the Encoder Composite Signal for a Absolute Position Detection of the Permanent Magnet Type Synchronous Motor (영구자석형 동기전동기의 절대 위치 검출을 위한 엔코더 복합 신호의 분석)

  • Kim, Jin-Ae;Joo, Jae-Hun;Jeong, Se-Young;Choi, Jung-Keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.180-184
    • /
    • 2007
  • For driving a sinusoidal type permanent magnet synchronous motor with a maximum continuous torque, a $120^0$ delayed three phase sinusoidal current input which matched with the absolute rotor position is needed at a stator coil. So, the detection of absolute rotor position is required inevitably. Thus the right angle relationship between stator magnetic field and rotor magnetic field has to be preserved at a stator by this commutation action. The detection of a absolute position for the commutation can be made generally by the output signal analysis of the encoder attached at a motor shaft. This study purposes to design signal processing logic circuits which can detect the absolute position of motor with a modem encoder system and generate the three reference wave for making sinusoidal current input at a stator coil.

  • PDF

A Study on a Rotor Position Sensor Offset Detection Method in a Permanent Magnet Synchronous Generator (영구자석형 동기발전기의 회전자 위치검출 센서의 옵셋 검출에 관한 연구)

  • Park, Kyusung;Shin, Sung-Hwan;Lee, Hokwang;Yoon, Youngdeuk;Lee, Geunho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.9
    • /
    • pp.914-921
    • /
    • 2014
  • In this paper, an algorithm is suggested to detect an offset angle of the absolute rotor position sensor after the initial assembly of a PMSG. Unlike previous studies in a stationary state, this one is not designed to detect an electrical angle but rather the absolute position of the rotor is detected while operating the generator. Also,a position sensor, current sensors and voltage sensor were used to ensure reliability. This technique completes the detection of the sensor offset in two steps. In the first step, a zero-crossing of the EMF is measured using a voltage sensor to detect the electrical angle offset when the alternator is actuated by the engine. In the second step, a high frequency current is injected along the d-axis on-line during the control of the generation, eventually to obtain the inductance using a DFT (Discrete Fourier Transform), and then to ultimately extract the final electrical angle offset through the comparison of the inductance magnitude. The suggested algorithm was validated with PSIM simulation and, furthermore, was tested with actual experiments on a dynamometer.

Initial Rotor Position Estimation of an IPMSM Based on Least Squares Approximation with a Polarity Identification (극성 판별이 가능한 최소 제곱법 기반의 IPMSM 회전자 초기 위치 추정)

  • Kim, Keon Young;Bak, Yeongsu;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.1
    • /
    • pp.72-75
    • /
    • 2018
  • An initial rotor position estimation method is proposed in this study for an interior permanent-magnet synchronous motor without a resolver or an absolute encoder. This method uses least squares approximation to estimate the initial rotor position. The magnetic polarity is identified by injection of short pulses. The proposed estimation process is robust because it does not require complex signal processing that depends on the performance of a digital filter. In addition, it can be applied to various servo systems because it does not require additional hardware. Experimental results validate the effectiveness of the proposed method using a standard industrial servomotor with interior-permanent magnets.

Sensorless driving strategy of Single-Phase Hybrid SRM basing on Back-EMF detection (역기전력을 이용한 단상 하이브리드 SRM의 위치 추정 방법)

  • Tang, Ying;Lee, Donghee;Ahn, Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.521-522
    • /
    • 2016
  • This paper presents a novel scheme to estimate the rotor position of a single-phase hybrid switched reluctance motor (HSRM). The proposed method uses the differential of back-EMF within a position region to estimate rotor position. By detecting the crossing-zero signal of back-EMF differential value, the minimum position of back-EMF corresponding to an absolute rotor position can be captured and used for position estimation four times in every mechanical rotation. In this way, a sensorless operation with adjustable turn on/off angle can be achieved without substantial computation. For the starting, two current comparators are adopted. The experimental verification using a prototype drive system is provided to demonstrate the viability of the proposed sensorless scheme.

  • PDF

Initial Rotor Position Detection a PM Synchronous Motor and Speed Control of an Elevator Door (영구자석 동기전동기의 회전자 초기위치 검출 및 엘리베이터 도어의 속도제어)

  • Song, Ki-Young;Oh, Hyun-Cheal;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.556-564
    • /
    • 2013
  • This paper proposes an initial rotor position detecting algorithm of a PM synchronous motor using an incremental encoder. The proposed algorithm estimates the phase offset between the rotor magnetic flux and the Z-pulse of the incremental encoder by applying six aligning mode current control. The absolute rotor position for driving a PM synchronous motor is calculated by using the phase offset of the Z pulse and A, B pulse signals of the encoder. The PMSM drives based on the estimated rotor position is applied to the elevator door system. The door length is measured on line at first setup of the elevator. The speed control for open, close, and reopen of the elevator door is also presented and the proposed algorithm for the elevator door system is verified by experiment.

Initial Rotor Position Estimation for an Interior Permanent-Magnet Synchronous Motor using Inductance Saturation (인덕턴스의 포화현상을 이용한 IPMSM의 회전자 초기 위치 추정)

  • Park, Nae-Chun;Lee, Yoon-Kyu;Kim, Sang-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.374-381
    • /
    • 2011
  • This paper proposes a new method to acquire an initial rotor position for IPMSM(Interior Permanent Magnet Synchronous Motor) without a position sensor at standstill. The proposed method is based on the variation of inductance caused by the magnetic saturation of stator core. Minimum number of voltage vectors are chosen to determine the initial rotor position. By using the resultant currents in combination with the inductance variation, the north pole and the absolute position of the rotor can be easily obtained. This method also has the advantage of not requiring motor parameters and additional hardware. Its validity is verified by experiments.