Feasibility of MatriXX for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료의 품질관리를 위한 이온전리함 매트릭스의 유용성 고찰)

  • Kang, Min-Young;Kim, Yoen-Lae;Park, Byung-Moon;Bae, Yong-Ki;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.91-97
    • /
    • 2007
  • Purpose: To evaluate the feasibility of a commercial ion chamber array for intensity modulated radiation therapy (IMRT) quality assurance (QA) was performed IMRT patient-specific QA Materials and Methods: A use of IMRT patient-specific QA was examined for nasopharyngeal patient by using 6MV photon beams. The MatriXX (Wellhofer Dosimetrie, Germany) was used for IMRT QA. The case of nasopharyngeal cancer was performed inverse treatment planning. A hybrid dose distribution made on the CT data of MatriXX and solid phantom all of the same gantry angle (0$^\circ$). The measurement was acquired with geometrical condition that equal to hybrid treatment planning. The $\gamma$-index (dose difference 3%, DTA 3 mm) histogram was used for quantitative analysis of dose discrepancies. An absolute dose was compared at the high dose low gradient region. Results: The dose distribution was shown a good agreement by gamma evaluation. A proportion of acceptance criteria was 95.8%, 97.52%, 96.28%, 98.20%, 97.78%, 96.64% and 92.70% for gantry angles were 0$^\circ$, 55$^\circ$, 110$^\circ$, 140$^\circ$, 220$^\circ$, 250$^\circ$ and 305$^\circ$, respectively. The absolute dose in high dose low gradient region was shown reasonable agreement with the RTP calculation within $\pm$3%. Conclusion: The MatriXX offers the dosimetric characteristics required for performing both relative and absolute measurements. If MatriXX use in the clinic, it could be simplified and reduced the IMRT patient-specific QA workload. Therefore, the MatriXX is evaluated as a reliable and convenient dosimeter for IMRT patient-specific QA.

  • PDF

Evaluation of the Accuracy and usability of Trigger mode in Respiratory Gated Radiation Therapy (호흡동조방사선치료를 위한 Trigger mode 투시영상 획득 시 호흡 속도에 따른 정확성 평가 - Phantom Study)

  • Park, je wan;Kim, min su;Um, ki cheon;Choi, seong hoon;Song, heung kwon;Yoon, in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.25-33
    • /
    • 2021
  • Purpose : The purpose of this study is to evaluate the accuracy and usefulness of the Trigger mode for the Respiratory Gated Radiation Therapy (RGRT) Materials and methods : A QUASAR respiratory phantom that inserted a 3 mm fiducial marker (a gold marker) was used to estimate the accuracy of the Trigger mode. And the 20 bpm was used as reference respiration rate in this study. The marker that placed at the center of the phantom was contoured, and the lower threshold of a gating window was fixed at 2.0 mm using an OBI with Truebeam STxTM. The upper threshold was measured every 0.5 mm from 1.0 mm to 3.0 mm. The respiration rates were changed every 10 bpm from 10 bpm to 60 bpm. We repeatedly measured five times to check the error rate of the trigger mode in the same condition. Result : The differences of a distance from a peak phase to upper threshold, 1.0 to 3.0 mm at a 20 bpm as a reference for 3 days in a row were 0.68±0.05 mm, 0.91±0.03 mm, 1.23±0.03 mm, 1.42±0.04 mm, and 1.66±0.06 mm, respectively. Measurement result of changes in respiratory rate compared to baseline respiratory rate in maximum absolute difference. The coefficient of determination (R2) to estimate the correlation between the respiration velocity and variation of absolute difference was on average 0.838, 0.887, 0.770, 0.850, and 0.906. The p-values of all the variables were below 0.05. Conclusion : Using Trigger mode during respiratory gated radiation therapy (RGRT), accuracy and usefulness of trigger mode at reference breathing rate were confirmed. However, inaccuracies depending on the rate of breathing it could be uncertain in case of respiration rate is faster than 20 bpm as a standard respiration rate compared to slower than 20 bpm. Consequently, when conducting a RGRT using the trigger mode, real time monitoring is required with well educated respiration.

A Study on the Career Occupational Mobility in Korea (한국의 경력내 직업이동에 관한 연구)

  • 김병관
    • Korea journal of population studies
    • /
    • v.20 no.1
    • /
    • pp.97-128
    • /
    • 1997
  • This paper was set out to study the structure of the career occupational mobility in the early and rapid phase of industrialization in Korea. By analyzing the individual life histories regarding occupational mobility and achievement, I propose a model of yearly career mobility of Korean men and Women during the period of 30 years between 1954 and 1983. With the occupational classification scheme of 5 groups - Upper Nonmanual, Lower Nonmanual, Self Employed, Manual, Farm - the mobility pattern in the person-year mobility table analyzed can be characterized primarily by the strong influence of immobility. The degree of immobility, however, is different by the occupational groups. The absolute amount of immobility can be summarized as being U-shaped. Overall, the pattern of mobility can be explained best by the concept of occupational distance. I then propose a model of relative career occupational mobility pattern that combines the conceptual and theoretical basis and the methodological rigor. The model is based on the notion of the reproduction of inequality, the labor market context, and the life history perspective. The model encompasses the 6 conceptual explanatory factors such as persistence effect, ceiling effect, traditional sector effect, nonmanual occupation effect, alternative mobility channel effect, and occupational distance effect, as well as the effects of both origin and destination occupations. The relative pattern of career mobiliity in Korea can be characterized by the following six findings. First, the persistence effect on the diagonal cells of the mobility table is dominant. Second, a clear evidence of the negative effect of occupational distance between nonmanual occupations and manual and farm occupations is found. Third, the out-mobility from farming took place regardless of the destination occupations. Fourth, the internal mobility within the nonmanual occupation block is high and bi-directional, and is exclusive against other occupations. Fifth, the 'self employed' occupation is serving a peculiar function in both inflow and outflow pattern. Last, the relative pattern of career occupation mobility is asymmetrical in terms of the upward and downward mobility.

  • PDF

자녀양육비의 추정

  • 김원년
    • Korea journal of population studies
    • /
    • v.10 no.1
    • /
    • pp.28-38
    • /
    • 1987
  • This paper was set out to study the structure of the career occupational mobility in the early and rapid phase of industrialization in Korea. By analyzing the individual life histories regarding occupational mobility and achievement, I propose a model of yearly career mobility of Korean men and Women during the period of 30 years between 1954 and 1983. With the occupational classification scheme of 5 groups - Upper Nonmanual, Lower Nonmanual, Self Employed, Manual, Farm - the mobility pattern in the person-year mobility table analyzed can be characterized primarily by the strong influence of immobility. The degree of immobility, however, is different by the occupational groups. The absolute amount of immobility can be summarized as being U-shaped. Overall, the pattern of mobility can be explained best by the concept of occupational distance. I then propose a model of relative career occupational mobility pattern that combines the conceptual and theoretical basis and the methodological rigor. The model is based on the notion of the reproduction of inequality, the labor market context, and the life history perspective. The model encompasses the 6 conceptual explanatory factors such as persistence effect, ceiling effect, traditional sector effect, nonmanual occupation effect, alternative mobility channel effect, and occupational distance effect, as well as the effects of both origin and destination occupations. The relative pattern of career mobiliity in Korea can be characterized by the following six findings. First, the persistence effect on the diagonal cells of the mobility table is dominant. Second, a clear evidence of the negative effect of occupational distance between nonmanual occupations and manual and farm occupations is found. Third, the out-mobility from farming took place regardless of the destination occupations. Fourth, the internal mobility within the nonmanual occupation block is high and bi-directional, and is exclusive against other occupations. Fifth, the 'self employed' occupation is serving a peculiar function in both inflow and outflow pattern. Last, the relative pattern of career occupation mobility is asymmetrical in terms of the upward and downward mobility.

  • PDF

A Study on the Determinants of Patent Citation Relationships among Companies : MR-QAP Analysis (기업 간 특허인용 관계 결정요인에 관한 연구 : MR-QAP분석)

  • Park, Jun Hyung;Kwahk, Kee-Young;Han, Heejun;Kim, Yunjeong
    • Journal of Intelligence and Information Systems
    • /
    • v.19 no.4
    • /
    • pp.21-37
    • /
    • 2013
  • Recently, as the advent of the knowledge-based society, there are more people getting interested in the intellectual property. Especially, the ICT companies leading the high-tech industry are working hard to strive for systematic management of intellectual property. As we know, the patent information represents the intellectual capital of the company. Also now the quantitative analysis on the continuously accumulated patent information becomes possible. The analysis at various levels becomes also possible by utilizing the patent information, ranging from the patent level to the enterprise level, industrial level and country level. Through the patent information, we can identify the technology status and analyze the impact of the performance. We are also able to find out the flow of the knowledge through the network analysis. By that, we can not only identify the changes in technology, but also predict the direction of the future research. In the field using the network analysis there are two important analyses which utilize the patent citation information; citation indicator analysis utilizing the frequency of the citation and network analysis based on the citation relationships. Furthermore, this study analyzes whether there are any impacts between the size of the company and patent citation relationships. 74 S&P 500 registered companies that provide IT and communication services are selected for this study. In order to determine the relationship of patent citation between the companies, the patent citation in 2009 and 2010 is collected and sociomatrices which show the patent citation relationship between the companies are created. In addition, the companies' total assets are collected as an index of company size. The distance between companies is defined as the absolute value of the difference between the total assets. And simple differences are considered to be described as the hierarchy of the company. The QAP Correlation analysis and MR-QAP analysis is carried out by using the distance and hierarchy between companies, and also the sociomatrices that shows the patent citation in 2009 and 2010. Through the result of QAP Correlation analysis, the patent citation relationship between companies in the 2009's company's patent citation network and the 2010's company's patent citation network shows the highest correlation. In addition, positive correlation is shown in the patent citation relationships between companies and the distance between companies. This is because the patent citation relationship is increased when there is a difference of size between companies. Not only that, negative correlation is found through the analysis using the patent citation relationship between companies and the hierarchy between companies. Relatively it is indicated that there is a high evaluation about the patent of the higher tier companies influenced toward the lower tier companies. MR-QAP analysis is carried out as follow. The sociomatrix that is generated by using the year 2010 patent citation relationship is used as the dependent variable. Additionally the 2009's company's patent citation network and the distance and hierarchy networks between the companies are used as the independent variables. This study performed MR-QAP analysis to find the main factors influencing the patent citation relationship between the companies in 2010. The analysis results show that all independent variables have positively influenced the 2010's patent citation relationship between the companies. In particular, the 2009's patent citation relationship between the companies has the most significant impact on the 2010's, which means that there is consecutiveness regarding the patent citation relationships. Through the result of QAP correlation analysis and MR-QAP analysis, the patent citation relationship between companies is affected by the size of the companies. But the most significant impact is the patent citation relationships that had been done in the past. The reason why we need to maintain the patent citation relationship between companies is it might be important in the use of strategic aspect of the companies to look into relationships to share intellectual property between each other, also seen as an important auxiliary of the partner companies to cooperate with.

Dose Verification Using Pelvic Phantom in High Dose Rate (HDR) Brachytherapy (자궁경부암용 팬톰을 이용한 HDR (High dose rate) 근접치료의 선량 평가)

  • 장지나;허순녕;김회남;윤세철;최보영;이형구;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.15-19
    • /
    • 2003
  • High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a phantom. In this study, the phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the phantom were then compared with the treatment planning system for the dose verification. The phantom needs to be designed such that the dose distributions can be quantitatively evaluated by utilizing the dosimeters with a high spatial resolution. Therefore, the small size of the thermoluminescent dosimeter (TLD) chips with a dimension of <1/8"and film dosimetry with a spatial resolution of <1mm used to measure the radiation dosages in the phantom. The phantom called a pelvic phantom was made from water and the tissue-equivalent acrylic plates. In order to firmly hold the HDR applicators in the water phantom, the applicators were inserted into the grooves of the applicator holder. The dose distributions around the applicators, such as Point A and B, were measured by placing a series of TLD chips (TLD-to-TLD distance: 5mm) in the three TLD holders, and placing three verification films in the orthogonal planes. This study used a Nucletron Plato treatment planning system and a Microselectron Ir-192 source unit. The results showed good agreement between the treatment plan and measurement. The comparisons of the absolute dose showed agreement within $\pm$4.0 % of the dose at point A and B, and the bladder and rectum point. In addition, the relative dose distributions by film dosimetry and those calculated by the planning computer show good agreement. This pelvic phantom could be a useful to verify the dose calculation algorithm and the accuracy of the image localization algorithm in the high dose rate (HDR) planning computer. The dose verification with film dosimetry and TLD as quality assurance (QA) tools are currently being undertaken in the Catholic University, Seoul, Korea.

  • PDF

BVI PHOTOMETRIC STUDY OF THE OLD OPEN CLUSTER RUPRECHT 6

  • Kim, Sang Chul;Kyeong, Jaemann;Park, Hong Soo;Han, Ilseung;Lee, Joon Hyeop;Moon, Dae-Sik;Lee, Youngdae;Kim, Seongjae
    • Journal of The Korean Astronomical Society
    • /
    • v.50 no.3
    • /
    • pp.79-92
    • /
    • 2017
  • We present a BV I optical photometric study of the old open cluster Ruprecht 6 using the data obtained with the SMARTS 1.0 m telescope at the CTIO, Chile. Its color-magnitude diagrams show the clear existence of the main-sequence stars, whose turn-off point is located around $V{\approx}18.45mag$ and $B-V{\approx}0.85mag$. Three red clump (RC) stars are identified at V = 16.00 mag, I = 14.41 mag and B - V = 1.35 mag. From the mean $K_s-band$ magnitude of RC stars ($K_s=12.39{\pm}0.21mag$) in Ruprecht 6 from 2MASS photometry and the known absolute magnitudes of the RC stars ($M_{K_S}=-1.595{\pm}0.025mag$), we obtain the distance modulus to Ruprecht 6 of $(m-M)_0=13.84{\pm}0.21mag$ ($d=5.86{\pm}0.60kpc$). From the ($J-K_s$) and (B - V ) colors of the RC stars, comparison of the (B - V ) and (V - I) colors of the bright stars in Ruprecht 6 with those of the intrinsic colors of dwarf and giant stars, and the PARSEC isochrone fittings, we derive the reddening values of E(B - V ) = 0.42 mag and E(V - I) = 0.60 mag. Using the PARSEC isochrone fittings onto the color-magnitude diagrams, we estimate the age and metallicity to be: $log(t)=9.50{\pm}0.10(t=3.16{\pm}0.82Gyr)$ and $[Fe/H]=-0.42{\pm}0.04dex$. We present the Galactocentric radial metallicity gradient analysis for old (age > 1 Gyr) open clusters of the Dias et al. catalog, which likely follow a single relation of $[Fe/H]=(-0.034{\pm}0.007)R_{GC}+(0.190{\pm}0.080)$ (rms = 0.201) for the whole radial range or a dual relation of $[Fe/H]=(-0.077{\pm}0.017)R_{GC}+(0.609{\pm}0.161)$ (rms = 0.152) and constant ([Fe/H] ~ -0.3 dex) value, inside and outside of RGC ~ 12 kpc, respectively. The metallicity and Galactocentric radius ($13.28{\pm}0.54kpc$) of Ruprecht 6 obtained in this study seem to be consistent with both of the relations.

UBVRI CCD PHOTOMETRY OF THE TYPE Ic SUPERNOVA SN 1994I IN M51: THE FIRST TWO MONTHS

  • LEE MYUNG GYOON;KIM EUNHYEUK;KIM SANG CHUL;KIM SEUNG LEE;PARK WON KEE;PYO TAE SOO
    • Journal of The Korean Astronomical Society
    • /
    • v.28 no.1
    • /
    • pp.31-43
    • /
    • 1995
  • We present UBVRI CCD photometry of the Type Ie supernova SN 19941 in M51 which was discovered on April 2, 1994 (UT). UBVRI CCD photometry of SN 1994 I were obtained for the period of the first two months from April 4, 1994, using the Seoul National University Observatory 60 cm telescope. The light curves of SN 19941 show several interesting features: (a) SN 19941 reaches the maximum brightness at B-band on April 8.23 (B = 13.68 mag), at V-band on April 9.10 (V = 12.89 mag), and at I-band on April 10.32 (I = 12.48 mag); (b) The light curves around the maximum brightness are much narrower than those of other types of supernovae; (c) The light curves after the peak decline more steeply than those of other types of supernovae; and (d) The colors get redder from $(V-R){\approx}0.2 mag ((V - I){\approx} 0.3 mag, (B - V){\approx}0.7 mag)$ on April 4 to $(V-R){\approx}0.6 mag ((V-1){\approx}0.9 mag, (B-V){\approx}1.3 mag)$ on April 18. Afterwards (V - R) colors get bluer slightly $(by\~0.005 mag/day)$, while (V-I) colors stay almost constant around $(V-1){\approx}1.0 mag$. The color at the maximum brightness is (B-V)=0.9 mag, which is $\~1$mag redder than the mean color of typical Type la supernovae at the maximum brightness. The light curves of SN 1994I are similar to those of the Type Ie supernova SN 1962L in NGC 1073. Adopting the distance modulus of $(m-M)_0 = 29.2 mag$ and the reddening of E(B - V) = 0.45 mag [Iwamoto et al. 1994, preprint for ApJ], we derive absolute magnitudes at the maximum brightness of SN 1994I, Mv(max) = -17.7 mag and MB(max) = -17.4 mag. This result shows that SN 1994I was $\~2$mag fainter at the maximum brightness compared with typical Type Ia supernovae. A narrower peak and faster decline after the maximum in the light curve of SN 1994I compared with other types of supernovae indicate that the progenitor of SN 1994I might be a lower mass star compared with those of other types of supernovae.

  • PDF

Acceptance Testing and Commissioning of Robotic Intensity-Modulated Radiation Therapy M6 System Equipped with InCiseTM2 Multileaf Collimator

  • Yoon, Jeongmin;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • Progress in Medical Physics
    • /
    • v.29 no.1
    • /
    • pp.8-15
    • /
    • 2018
  • This work reports the acceptance testing and commissioning experience of the Robotic Intensity-Modulated Radiation Therapy (IMRT) M6 system with a newly released $InCise^{TM}2$ Multileaf Collimator (MLC) installed at the Yonsei Cancer Center. Acceptance testing included a mechanical interdigitation test, leaf positional accuracy, leakage check, and End-to-End (E2E) tests. Beam data measurements included tissue-phantom ratios (TPRs), off-center ratios (OCRs), output factors collected at 11 field sizes (the smallest field size was $7.6mm{\times}7.7mm$ and largest field size was $115.0mm{\times}100.1mm$ at 800 mm source-to-axis distance), and open beam profiles. The beam model was verified by checking patient-specific quality assurance (QA) in four fiducial-inserted phantoms, using 10 intracranial and extracranial patient plans. All measurements for acceptance testing satisfied manufacturing specifications. Mean leaf position offsets using the Garden Fence test were found to be $0.01{\pm}0.06mm$ and $0.07{\pm}0.05mm$ for X1 and X2 leaf banks, respectively. Maximum and average leaf leakages were 0.20% and 0.18%, respectively. E2E tests for five tracking modes showed 0.26 mm (6D Skull), 0.3 mm (Fiducial), 0.26 mm (Xsight Spine), 0.62 mm (Xsight Lung), and 0.6 mm (Synchrony). TPRs, OCRs, output factors, and open beams measured under various conditions agreed with composite data provided from the manufacturer to within 2%. Patient-specific QA results were evaluated in two ways. Point dose measurements with an ion chamber were all within the 5% absolute-dose agreement, and relative-dose measurements using an array ion chamber detector all satisfied the 3%/3 mm gamma criterion for more than 90% of the measurement points. The Robotic IMRT M6 system equipped with the $InCise^{TM}2$ MLC was proven to be accurate and reliable.

VRS-based Precision Positioning using Civilian GPS Code Measurements (가상기준점 기반 코드신호를 이용한 정밀 측위)

  • Bae, Tae-Suk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.2
    • /
    • pp.201-208
    • /
    • 2011
  • With the increase in the number of smartphone users, precise 3D positional information is required by various applications. The positioning accuracy using civilian single-frequency pseudoranges is at the level of 10 m or so, but most applications these days are asking for a sub-meter level Therefore, instead of an absolute positioning technique, the VRS-based differential approach is applied along with the correction of the double-differenced (DD) residual errors using FKP (Flachen-Korrektur-Parameter). The VRS (Virual Reference Station) is located close to the rover, and the measurements are generated by correcting the geometrical distance to those of the master reference station. Since the unmodeled errors are generally proportional to the length of the baselines, the correction parameters are estimated by fitting a plane to the DD pseudorange errors of the CORS network. The DD positioning accuracy using 24 hours of C/A code measurements provides the RMS errors of 37 cm, 28 cm for latitudinal and longitudinal direction, respectively, and 76 cm for height. The accuracy of the horizontal components is within ${\pm}0.5m$ for about 90% of total epochs, and in particular the biases are significantly decreased to the level of 2-3 cm due to the network-based error modeling. Consequently, it is possible to consistently achieve a sub-meter level accuracy from the single-frequency pseudoranges using the VRS and double-differenced error modeling.