• 제목/요약/키워드: abdominal ultrasound

검색결과 243건 처리시간 0.024초

복부 할로잉 운동에서 실시간 초음파 영상 피드백의 사용 효과 (The Use of Real-Time Ultrasound Imaging for Feedback during Abdominal Hollowing)

  • 권남희;이현옥;박두진
    • 대한물리의학회지
    • /
    • 제6권3호
    • /
    • pp.303-310
    • /
    • 2011
  • Purpose : This study examined the feedback effect of real-time ultrasound imaging on the thickness of transversus abdominis(TrA), internal abdominal oblique(IO) and external abdominal oblique(EO) during abdominal hollowing exercise(AHE) in crook lying. Methods : We performed this study on 30 healthy men who voluntarily consented to participate in this study after listening to its purpose and method. All subject were divided into an experimental group(n=15) with using the real-time ultrasound imaging feedback(RUIF) and a control group(n=15) without the RUIF The thickness changes between rest and AHE were compared between the two groups in crook lying. Results : The difference in TrA and EO thickness changes between the groups were significant in crook lying (p<0.05). Conclusion : The group with using real-time ultrasound imaging feedback showed a higher increase in the thickness of TrA than the other group without real-time ultrasound imaging feedback. And the thickness of EO in the group with using real-time ultrasound imaging feedback decreased than the other group without real-time ultrasound imaging feedback. If the muscle thickness can be regarded as an indicator of muscle activity, RUIF will be helpful for inducing the independent activity of TrA by reducing the activities of abdominal muscles such as EO.

초음파 영상을 이용한 교각운동 시 복부 드로잉-인 운동이 복부 근육의 두께에 미치는 영향 (The Effect of Abdominal Muscle Drawing-In Exercise During Bridge Exercise on Abdominal Muscle Thickness, using for Real-time Ultrasound Imaging)

  • 하유;이건철;배원식;조영재
    • 대한물리의학회지
    • /
    • 제8권2호
    • /
    • pp.231-238
    • /
    • 2013
  • PURPOSE: The purpose of this study is to find out the thickness variation of the superficial and deep abdominal muscles by measuring the thickness of the abdominal muscles. METHODS: 35 young, healthy adults(24 mens and 11 womens) participated in this study. The first, when only bridge exercise we had measured the thickness of their abdominal muscles by the ultrasound. The second, when the abdominal drawing-in during maintaining the bridge exercise we had measured the thickness of their abdominal muscles by the ultrasound. A pared t-test was used to determine a statistical significance for the thickness variation of the superficial and deep abdominal muscles. RESULTS: Results of before and after comparative analysis. The surperficial muscles(rectus abdominis, external obilique) statistically significantly reduced in the thickness and the deep muscle(transeverse abdominis) statistically significantly increased in the thickness. CONCLUSION: We have shown that the abdominal drawing-in exercise during maintaining the bridge exercise was effective to increase in strengthening abdominal deep muscle selectively.

The Effect of Real-time Ultrasound Imaging Feedback during Abdominal Hollowing in Four Point Kneeling to Healthy Men

  • Park, Du-Jin
    • The Journal of Korean Physical Therapy
    • /
    • 제22권6호
    • /
    • pp.1-6
    • /
    • 2010
  • Purpose: This study investigated the effects of visual feedback during abdominal hollowing (AH) in four point kneeling position, using real-time ultrasound imaging through measurement of the changes in the thickness of transversus abdominis (TrA), internal abdominal oblique (IO), and external abdominal oblique (EO). Methods: The subjects of this study were 32 healthy males who were divided intothe experimental group of 16 subjects and the control group of 16 subjects. The real-time ultrasound feedback was applied to the experimental group while they were educated on the AH exercise in four point kneeling whereas only general education and training were given to the control group. After the training, the changes in the thickness of abdominal muscles during AH in four point kneeling were compared between the experimental group and the control group. Results: The differences of the changes in the thickness of TrA and EO between the two groups were statistically significant. Conclusion: The experimental group experienced a higher increase in the thickness of TrA than the control group while the thickness of IO and EO of the experimental.

Effects of therapeutic ultrasound for contour asymmetry after liposuction, a case study

  • Wong, Yiu Ming
    • 셀메드
    • /
    • 제5권3호
    • /
    • pp.19.1-19.2
    • /
    • 2015
  • This is a case report involving a novel setting of sonographic scan for thickness of superficial abdominal fat and a non-invasive approach for reduction of the fat thickness. A 38-year-old woman complained of her abdominal contour asymmetry after the laser-assisted liposuction performed two years ago. Compression-free sonographic scanning confirmed that her superficial abdominal fat was thicker in left side than that of right side. After 9 sessions of 40KHz therapeutic ultrasound, the contour asymmetry was reduced.

근로자의 복부비만관리를 위한 유산소운동과 병행한 복부초음파의 효과 연구 (Effects of Aerobic Exercise Combined Abdominal Ultrasound Therapy for Obesity Management Of Workers)

  • 이연섭;장원석
    • 대한통합의학회지
    • /
    • 제3권1호
    • /
    • pp.23-28
    • /
    • 2015
  • Purpose: This study aimed to examine the effects of abdominal ultrasound accompanied by aerobic exercise in shift work employees working in industry. Method: Thirty shift work employees were randomly assigned to either a aerobic exercise group (control group) or a aerobic exercise and ultrasound treatment group (experimental group). The control group carried out aerobic exercise five times per week for 4 weeks, while the experimental group performed aerobic exercise twice per week and received deep ultrasound three times per week for 4 weeks. Result: The results showed that there were no significant differences in body composition between the two groups. There were significant changes in weight, lean body mass, body fat mass, and body mass index in the control group; meanwhile, significant changes in weight and body fat mass were observed in the experimental group. Conclusion: According to the results of this study concerning short-term obesity management programs, aerobic exercise was effective for improving of body composition and weight loss, while aerobic exercise combined with abdominal ultrasound had a good effect secondary complication prevention.

Successful Treatment of Abdominal Cutaneous Entrapment Syndrome Using Ultrasound Guided Injection

  • Hong, Myong Joo;Kim, Yeon Dong;Seo, Dong Hyuk
    • The Korean Journal of Pain
    • /
    • 제26권3호
    • /
    • pp.291-294
    • /
    • 2013
  • There are various origins for chronic abdominal pain. About 10-30% of patients with chronic abdominal pain have abdominal wall pain. Unfortunately, abdominal wall pain is not thought to be the first origin of chronic abdominal pain; therefore, patients usually undergo extensive examinations, including diagnostic laparoscopic surgery. Entrapment of abdominal cutaneous nerves at the muscular foramen of the rectus abdominis is a rare cause of abdominal wall pain. If abdominal wall pain is considered in earlier stage of chronic abdominal pain, unnecessary invasive procedures are not required and patients will reach symptom free condition as soon as the diagnosis is made. Here, we report a case of successful treatment of a patient with abdominal cutaneous nerve entrapment syndrome by ultrasound guided injection therapy.

개에서 초음파를 이용한 간 종괴의 세침흡인술 증례 (Diagnostic Approach of Hepatic Mass using Ultrasound Guided Fine Needle Aspiration in a Dog)

  • 최호정;이기창;최민철;윤정희
    • 한국임상수의학회지
    • /
    • 제21권2호
    • /
    • pp.181-183
    • /
    • 2004
  • Hepatic mass was aspirated under the guidance with ultrasound in 9-year old female maltese with signs of anorexia, hematochezia, vomiting, depression, and abdominal distension. Radiographic and abdominal ultrasonographic examinations were performed, which revealed enlarged tubular shaped uterine mass and solitary, small round hyperechoic hepatic mass dorsal to gall bladder as an incidental finding. Ultrasound-guided fine needle aspiration was completed, but histologic confirmation should be made for definitive diagnosis by tissue core or wedge biopsy.

할로잉 운동 시 시각적 피드백 방법에 따른 복근 두께에 미치는 영향 비교 (Comparison of the Abdominal Muscle Thickness during Abdominal Hollowing Exercise According to the Visual Feedback Method)

  • 김하림;손호희
    • 대한물리의학회지
    • /
    • 제16권3호
    • /
    • pp.107-113
    • /
    • 2021
  • PURPOSE: Selective strengthening of the transverse abdominis muscle (TrA) during abdominal hollowing makes an important contribution to the stability and control of the spine. This study examined the effects of abdominal hollowing exercise (AHE) according to the visual feedback method on the external oblique, internal oblique, and transverse abdominis muscles. METHODS: Twenty healthy subjects were assigned randomly to an AHE with visual feedback from real-time ultrasound image (group A, n = 10), AHE with visual feedback with pressure biofeedback unit (group B, n = 10). Both groups underwent 20 min of AHE with visual feedback once daily, five days/week for two weeks. The changes in the muscle thickness of the TrA, internal oblique abdominal muscle (IO), and external oblique abdominal muscle (EO) were measured by ultrasonography. RESULTS: The thickness of TrA was changed significantly in both groups (p < .05). However, the lowest minimal detectable changes were achieved in Group A. The thickness of the IO and EO muscles in group A was changed significantly, but there were no significant changes in group B. CONCLUSION: Both visual feedback methods were effective for strengthening the TrA muscles selectively. Nevertheless, AHE with visual feedback using real-time ultrasound images may be more useful in trA muscle contraction.

상완혈 자침시 복부 장기의 안전성 확보를 위한 초음파시스템의 신뢰도 측정 (Reliability Measurement of the Ultrasound for Safety of the Abdominal Organs on Acupuncturing Sangwan (CV13))

  • 김지혜;백태현
    • 대한한의진단학회지
    • /
    • 제15권2호
    • /
    • pp.203-214
    • /
    • 2011
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with a ultrasound device with three methods of 3.5 MHz convex probe and gel, 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad, three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver were 9.20 (9 MHz linear probe and gel), 14.70 (9 MHz linear probe and solid gel pad). So we concluded that repeatabilities and reproducibilities of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with the methods of 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad were acceptable.

근전도, 초음파와 DITI를 이용한 전기자극의 성인여성 복부비만 개선 효과 관찰 (The Effects of Functional Electrical Stimulation on Abdominal Obesity Improvement of Adult Women by EMG, Ultrasound and DITI)

  • 이현주;태기식
    • 한국정밀공학회지
    • /
    • 제31권11호
    • /
    • pp.1051-1058
    • /
    • 2014
  • In this study, we investigated the improvement effect of obesity by treatment with a developed low frequency electrical stimulation system. Thirty female in their 20's as an experiment subjects divided 3 groups(control, commercialized device, developed device) were treated with electrical stimulation on abdomen for 4 weeks. The body weight, body mass index(BMI), waist-hip ratio(WHR), muscle strength, muscle(transverse abdominis(TrA), internal obliquus abdominis(IO), external obliquus abdominis(EO)), fat thickness and abdominal surface temperature were measured by electromyogram(EMG), ultrasound and digital infrared thermal image(DITI). In the result, the body weight and BMI were decreased. Subcutaneous abdominal fat were significantly reduced after 4 weeks. The muscle strength and TrA muscle thickness was increased 13.2%(p<0.05), and 35.5%, respectively. The fat thickness showed decrease in abdomen (p<0.05). Infrared measurement on abdominal surface temperature as a parameter of improvement in blood circulation was significantly increased(p<0.05). Therefore, the low frequency stimulation showed positive effects on parameters of the obesity improvement.