• Title/Summary/Keyword: a.c. impedance

Search Result 713, Processing Time 0.028 seconds

A.C. Impedance Properties of HA/Ti Compound Layer coated Ti-30Ta-(3~15)Nb Alloys (Ti-30Ta-(3~15)Nb 합금에 HA/Ti 복합 코팅한 표면의 교류임피던스 특성)

  • Jeong, Y.H.;Lee, H.J.;Moong, Y.P;Park, G.H.;Jang, S.H.;Son, M.K.;Choe, H.C.
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.5
    • /
    • pp.181-188
    • /
    • 2008
  • A.C. impedance properties of HA/Ti compound layer coated Ti-30Ta-($3{\sim}15$)Nb alloys have been studied by electrochemical method. Ti-30Ta binary alloys contained 3, 7, 10 and 15 wt% Nb were manufactured by the vacuum furnace system. And then specimen was homogenized at $1000^{\circ}C$ for 24 hrs. The sample was cut and polished for corrosion test and coating. It was coated with HA/Ti compound layer by magnetron sputter. The non-coated and coated morphology of Ti alloy were analyzed by X-ray diffractometer (XRD), energy X-ray dispersive spectroscopy (EDX) and filed emission scanning electron microscope (FE-SEM). The corrosion behaviors were investigated using A.C. impedance test (PARSTAT 2273, USA) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. Ti-30Ta-($3{\sim}15\;wt%$)Nb alloys showed the ${\alpha}+{\beta}$ phase, and $\beta$ phase peak was predominantly appeared in the case of increasingly Nb contents. The microstructures of Ti alloy were transformed from needle-like structure to equiaxed structure as Nb content increased. From the analysis of coating surface, HA/Ti composite surface uniformed coating layer with 750 nm thickness. The growth directions of film were (211), (112), (300) and (202) for HA/Ti composite coating on the surface after heat treatment at $550^{\circ}C$, whereas, the growth direction of film was (110) for Ti coating. The polarization resistance ($R_p$) of HA/Ti composite coated Ti-alloys were higher than those of the Ti and HA coated samples in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. Especially, corrosion resistance of Ti-Ta-Nb system increased as Nb content increased.

Electrical characteristics of $Al_2O_3$ added ZnO ($Al_2O_3$가 첨가된 ZnO의 전기적 특성)

  • 최우성;소병문;홍진웅
    • Electrical & Electronic Materials
    • /
    • v.9 no.6
    • /
    • pp.572-577
    • /
    • 1996
  • Alternating current and direct current of pure, ball milled, and $Al_{2}$O$_{3}$ added ZnO were investigated by means of complex impedance measurement and voltage-current source measurement unit. The electrical conductivity of A1$_{2}$O$_{3}$ added ZnO samples increases when the content of A1$_{2}$O$_{3}$ is used within 1 at% and decreases when it's used more than that. The increase and decrease of electrical conductivity seem to be the donor effect of $Al_{2}$O$_{3}$ and the increase of the number of ZnO grains, respectively. Impedance spectrum seems to be one semircicle. The size of semicircle increase with increasing the A1$_{2}$O$_{3}$ contents. The calculated dielectric constant(at 50.deg. C) were about 70-140 at the peak of the semicircle. The semicircles seem not to be the resistance of ZnO grain as compared to that of 10 for pure ZnO.

  • PDF

The implementation of modular respiratory system for patient monitoring (환자감시를 위한 모듈형 호흡 시스템의 구현)

  • 박종억;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.503-506
    • /
    • 2001
  • There are four factors for patient monitoring : electrocardiography, blood pressure, temperature and respiration. While there are a lot of studies of E.C.C (electro-cardiography) monitoring system in the world, the studies of Respiratory system are not enough and leave much to be desired in the country. In this paper, we developed a respiratory system with the electrical impedance change of the lungs depending on the breath. Using the same electrode, we can monitor E.C.C and Respiration simultaneously, so we can monitor a patient's no-breathing state due to the central nerve paralysis in the emergency room easily. In this monitoring system, the analog part was made separated from the digital part for reducing power source noise and protecting patient from electric shock. The analog part consists of the several parts a high-frequency sine-wave generator, all amplifier for amplifying any impedance change signal, an analog processing part for rectifying and filtering. And the digital parts consists of three parts an AD convertor for converting analog signal to digital signal, digital filter, and a digital part for digital signal processing. This system's merits are using the same electrode with E.C.C and developing the multiple patient monitoring system easily.

  • PDF

A Study on Analysis Electrical Characteristics of Cable Lenght change about area Boundary of UM71C Audio Frequency Track Circuit (고속철도 AF궤도회로경계구간 케이블길이 변화에 따른 전기특성 분석연구)

  • Choi, Jae Sik;Kim, Hie Sik;Park, Ju Hun;Kim, Bum Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4849-4854
    • /
    • 2015
  • It has been often occurred for the outside components(BU, SVaC, DB) of UM71c AF track circuits to be broken down caused by some pieces of falling ice in the winter time or by infrastructure repairing equipments while facility maintenance works since 2004, opening of Kyeongbu High Speed Rail Express. In this paper, we proposed that we could move the outside components of UM71c track circuit out of wayside from present place. Then we can assure that the life time of those components would be extended. So we simulated the electrical characteristics by changing cable length using MATLAB Simulinks and we designed the compensation capacitor. Also, we obtained the same results as those of simulation by field demonstration test on site. The design specifications obtained from this field verification test could be applied in the absent section of track circuit, if only have a little more intensified research to compensate changed electrical characteristics and to redesign inner impedance of the track circuit.

Nafion Impregnated Electrospun Polyethersulfone Membrane for PEMFC (Nafion 용액 함침과 전기방사를 이용한 고분자 전해질 연료전지용 폴리에테르술폰 막)

  • Lee, Hong-Yeon;Hwang, Hyung-Kwon;Park, Sang-Sun;Choi, Sung-Won;Shul, Yong-Gun
    • Membrane Journal
    • /
    • v.20 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • In this study, we manufactured the membrane using the polyethersulfone (PES) of fiber by using the electrospinning method. The polymer electrolyte membrane for fuel cells was manufactured by impregnating Nafion solution to the porous PES membrane. We confirmed that electrospun PES membrane has higher thermal stability than Nafion 212 membrane by thermogravimetric analysis. Impregnated Nafion in the pores of the electrospun PES membrane was characterized by scanning electron microscopy. The AC impedance data shows the hydrogen ionic conductivity of $10^{-2}$ S/cm below $100^{\circ}C$. Nafion impregnated PES membrane shows the maximum performance at $90^{\circ}C$ showing current density of 389 mA/$cm^2$ at 0.6 V, while Nafion 212 membrane shows maximum at $75^{\circ}C$.

Non-Contact Vital Signal Sensor Based on Impedance Variation of Resonator (공진기의 임피던스 변화에 근거한 비접촉 생체 신호 센서)

  • Kim, Kee-Yun;Kim, Sang-Gyu;Hong, Yunseog;Yook, Jong-Gwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.9
    • /
    • pp.813-821
    • /
    • 2013
  • In this paper, a vital signal sensor based on impedance variation of resonator is presented. Proposed vital signal sensor can detect the vital signal, such as respiration and heart-beat signal. System is composed of resonator, oscillator, surface acoustic wave (SAW) filter, and power detector. The cyclical movement of a dielectric such as a human body, causes the impedance variation of resonator within the near-field range. So oscillator's oscillation frequency variation is effected on resonator's resonant frequency. SAW filter's skirt characteristic of frequency response can be transformed a small amount of frequency deviation to a large variation. Aim to enhance the existing sensor detection range, proposed sensor operates in 870 MHz ISM band, and detect respiration and heart-beat signal at distance of 120 mm.

The Electrochemical Characterization of $LiMn_{2-y}M_{y}O_4$ Cathode Material - I. Crystal Structure and AC Impedance Properties of $LiMn_{2-y}Mg_{y}O_4$ ($LiMn_{2-y}M_{y}O_4$ 정극 활물질의 전기화학적 특성 - I. $LiMn_{2-y}Mg_{y}O_4$의 결정 구조 및 AC Impedance 특성)

  • 정인성;김종욱;구할본;김형곤;손명모
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.4
    • /
    • pp.309-315
    • /
    • 2001
  • Crystallized $LiMn_{2-y}Mg_{y}O_4$ powder was prepared by calcing the mixture of LiOH.$H_2O$, $MnO_2$ and MgO at $800^{\circ}C$ for 36h in an air atmosphere. The structure of $LiMn_{2-y}Mg_{y}O_4$ crystallites was analyzed from powder X-ray diffraction data as a cubic spinel, space group Fd3m. Though all cathode material showed spinel phase based on cubic phase in X-ray diffraction, other peaks gradually exhibited and became intense with increasing y value in $LiMn_{2-y}Mg_{y}O_4$. However, ununiform which calculated by (111) face and (222) face was constant in spite of the increase of y value, except pure $LiMn_2O_4$. AC impedance of Li/$LiMn_{2-y}Mg_{y}O_4$ cells revealed the similar resistance of about $70\Omega$ before cycling. In addition, The impedance of Li/$LiMn_{1.9}Mg_{0.1}O_4$ cell changed during charge and discharge or after cycling.

  • PDF

Impedance Change of Aluminum Pad Coated with Epoxy Molding Compound for Semiconductor Encapsulant (반도체 패키지 봉지재용 에폭시 수지 조성물이 코팅된 알루미늄 패드의 임피던스 변화)

  • 이상훈;서광석;윤호규
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.3
    • /
    • pp.37-44
    • /
    • 2000
  • The corrosion behavior of aluminum pad coated with epoxy molding compound (EMC) was investigated using electrochemical impedance spectroscopy (EIS). The impedance change was evaluated by the absorption of deionized water (DI water) to EMC coating and the interface between EMC and aluminum. During the absorption a decrease in resistance and thus an increase in capacitance of EMC as well as the interface of EMC/Al could be observed. Up to about 170 hours of absorption the EMC was saturated with the water molecules and ions generated from EMC. Subsequently the ionic water was penetrated to the interface and finally the corrosion of aluminum was occurred by the Dl water and ions. From measuring the adhesion strength with the Dl water absorption it was expected that the saturation of water and ions in the interface decreased the adhesion strength. The higher filler content of EMC should be necessary to inhibit the corrosion of aluminum electrode in microelectronic packages.

  • PDF

A Study on the Thermal Characteristics of a Coupler to Improve the Performance of Electrodeless Lamp (무전극 램프의 성능 향상을 위한 커플러의 열특성 연구)

  • Lee, Kye-Seung;Lee, Jae-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.6
    • /
    • pp.487-495
    • /
    • 2017
  • The thermal characteristics of the electrodeless lamp are one of the main factors that determine the design and performance of the lamp. The coupler changes the impedance characteristic by heat and its use temperature is usually within about $150^{\circ}C$. In this study, we observed the phenomenon when the coupler was exposed at a temperature of $150^{\circ}C$ or higher, which has not been discussed so far. Two types of coupler A and coupler B with different spacing between the inner tube and the coupler were analyzed for electrical, thermal and optical properties and deterioration characteristics with different heat and heat shielding conditions. First, the impedance of the system is obtained and used as a criterion for analyzing the electrical characteristics through it. The diameters of the two types of couplers are 1 mm, and the experimental result shows that the coupler diameter is 1 mm, which can cancel out the loss of the magnetic field strength. Therefore, based on these results, when the coupler is exposed to high temperature of about $200^{\circ}C$, the efficient design method corresponding thereto is proposed.

Stopband-Extended and Size-Miniaturized Low-Pass Filter with Three Transmission Zeros

  • Li, Lin;Bao, Jia;Du, Jing-Jing;Wang, Yaming
    • ETRI Journal
    • /
    • v.36 no.2
    • /
    • pp.286-292
    • /
    • 2014
  • This paper presents a compact structure composed of an upper high-impedance transmission line, a middle extended parallel coupled line, and a pair of inter-coupled symmetrical stepped impedance stubs. Detailed investigation into this structure based on an equivalent circuit analysis reveals that this proposed structure exhibits a quasi-elliptic low-pass filtering response with three transmission zeros. Moreover, the positions of the three transmission zeros can be tuned and reallocated flexibly by choosing the proper circuit parameters. Finally, the design concept is validated through the design, fabrication, and measurement of two exemplary low-pass filters (LPFs) with one single unit and two cascaded asymmetric units. The measured results agree well with the simulated results. In addition, in the range of $1.42f_c$ to $7.03f_c$, the fabricated quasi-elliptic LPFs experimentally demonstrate a very wide upper-stopband of 20 dB using a compact size of only $0.0089{\lambda}_g{^2}$, where ${\lambda}_g$ is the guided wavelength of a $50{\Omega}$ transmission line at the central frequency.