• Title/Summary/Keyword: a standard

Search Result 39,533, Processing Time 0.078 seconds

Study on Geological Distribution of Fluorine in Forest Aggregate within Korea (산림골재 내 불소의 지질학적 분포 연구)

  • Yeong-Il Jeong;Kun-Ki Kim;Soon-Oh Kim;Sang-Woo Lee;Jin-Young Lee
    • Economic and Environmental Geology
    • /
    • v.57 no.2
    • /
    • pp.233-241
    • /
    • 2024
  • This study was conducted to investigate the geological distribution characteristics of fluorine in rocks, which can be a major resource of forest aggregates in Korea. Samples of forest aggregates were collected from 224 sites in 22 cities and counties for this study. The national background concentration was 344 mg/kg, which was significantly lower than the average fluorine concentration of crustal, which was 625 mg/kg, and slightly higher than the average fluorine concentration of world soil, which was 321 mg/kg. In terms of region and tectonic structure, fluorine concentrations were investigated to be highest in Gyeonggi-do(394 mg/kg) and Gyeonggi massif(396 mg/kg), respectively. The concentration distribution by the origin of the parent rock was in the order of metamorphic rock(362 mg/kg) > sedimentary rock(354 mg/kg) > igneous rock(328 mg/kg), and the concentration distribution by geologic ages was the highest in the Paleozoic at 394 mg/kg. The concentration distribution by rock types was in the order of diorite(515 mg/kg) > gneisses(377 mg/kg) > schists(344 mg/kg) > phyllite(306 mg/kg) > granites(305 mg/kg) > quartz porphyry(298 mg/kg). Consequently, it is speculated that gneisses and schists, Precambrian metamorphic rocks in the Gyeonggi massif that forms the crust of Gyeonggi-do, contain high fluorine concentrations.

Quantitative Evaluation of Liver Fibrosis on T1 Relaxometry in Comparison with Fibroscan (Fibroscan과 비교를 통한 T1 MR Relaxometry를 이용한 간섬유화의 정량적 평가)

  • Byeong Hak Sim;Suk Hee Heo;Sang Soo Shin;Seong Beom Cho;Yong Yeon Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.365-378
    • /
    • 2020
  • Purpose This study was performed to determine whether the T1 relaxation time of gadoxetic acid-enhanced liver MR imaging is useful for detecting and staging liver fibrosis in patients with chronic liver disease. Materials and Methods One hundred and three patients with suspected focal liver lesion underwent MR imaging and Fibroscan. Fibroscan was chosen as the reference standard for classifying liver fibrosis. T1 relaxation times were acquired before (preT1), 20 minutes after (postT1) contrast administration, and reduction rate of T1 relaxation time (rrT1) on transverse 3D VIBE (volumetric interpolated breath-hold examination) sequence using 3T MR imaging. The optimal cut-off values for the fibrosis staging were determined with ROC analysis. Results PreT1 and postT1 increased and rrT1 decreased constantly with increasing severity of liver fibrosis according to the METAVIR score (F0-F4). There were statistically significant differences between F2 and F3 in preT1 (F2, 836.0 ± 74.7 ms; F3, 888.6 ± 77.5 ms, p < 0.05) and between F3 and F4 in postT1 (F3, 309.0 ± 80.2 ms; F4, 406.6 ± 147.7 ms, p < 0.05) and rrT1 (F3, 65.4 ± 7.7%; F4, 57.3 ± 11.4%, p < 0.05). ROC analysis revealed that combination test (preT1 + postT1) was the best test for predicting liver fibrosis. Conclusion PreT1 and postT1 increased constantly with increasing severity of liver fibrosis. T1 mapping in gadoxetic acid-enhanced liver MR imaging could be a helpful complementary sequence to determine the liver fibrosis stage.

Tumor Margin Infiltration in Soft Tissue Sarcomas: Prediction Using 3T MRI Texture Analysis (연조직 육종의 종양 가장자리 침윤: 3T 자기공명영상 텍스처 분석을 통한 예측)

  • Minji Kim;Won-Hee Jee;Youngjun Lee;Ji Hyun Hong;Chan Kwon Jung;Yang-Guk Chung;So-Yeon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.112-126
    • /
    • 2022
  • Purpose To determine the value of 3 Tesla (T) MRI texture analysis for predicting tumor margin infiltration in soft tissue sarcomas. Materials and Methods Thirty-one patients who underwent 3T MRI and had a pathologically confirmed diagnosis of soft tissue sarcoma were included in this study. Margin infiltration on pathology was used as the gold standard. Texture analysis of soft tissue sarcomas was performed on axial T1-weighted images (WI) and T2WI, fat-suppressed contrast-enhanced (CE) T1WI, diffusion-weighted images (DWI) with b-value of 800 s/mm2, and apparent diffusion coefficient (ADC) was mapped. Quantitative parameters were compared between sarcomas with infiltrative margins and those with circumscribed margins. Results Among the 31 patients with soft tissue sarcomas, 23 showed tumor margin infiltration on pathology. There were significant differences in kurtosis with the spatial scaling factor (SSF) of 0 and 6 on T1WI, kurtosis (SSF, 0) on CE-T1WI, skewness (SSF, 0) on DWI, and skewness (SSF, 2, 4) on ADC between sarcomas with infiltrative margins and those with circumscribed margins (p ≤ 0.046). The area under the receiver operating characteristic curve based on MR texture features for identification of infiltrative tumor margins was 0.951 (p < 0.001). Conclusion MR texture analysis is reliable and accurate for the prediction of infiltrative margins of soft tissue sarcomas.

The continuous application effect of the food waste composts on the cultivated upland soils and plants (밭에서 음식물류폐기물 활용 퇴비의 연용이 토양 및 작물에 미치는 영향)

  • Kwon, Soon-Ik;So, Kyu-Ho;Hong, Seung-Gil;Kim, Gun-Yeob;Seong, Ki-Seog;Park, Woo-Kyun;Kim, Kwon-Rae;Lee, Deog-Bae;Jung, Kwang-Yong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.3
    • /
    • pp.71-81
    • /
    • 2009
  • Food waste has been actively used as a composting material in order to reduce the environmental pollution load and to enhance the recycling of resources. In this study, the longterm effects of continuous application of food waste compost to soils on both the crop production and the soil properties were examined to ensure the safety of food waste compost in agricultural use. In addition, we collected the preliminary data for establishing standard application rate of food waste compost for agricultural utilization. Based on conventional nitrogen application rate of chemical fertilizer for crop cultivation, pig manure compost $(24g\;N\;kg^{-1}$, $8g\;P_2O_5\;kg^{-1}$, and $10.4g\;K_2O\;kg^{-1})$ and food waste compost ($20g\;N\;kg^{-1}$, $20.1g\;P_2O_5\;kg^{-1}$, and $6.5g\;K_2O\;kg^{-1}$) were applied to the upland soil in $2{\times}2{\times}2m$ lysimeter in which lettuce (Lactuca sativa var. crispa), Chinese cabbage (Brassica campestris subsp. napus var. pekinensis), red pepper (Capsicum annuum), and potato (Solanum tuberosum) were grown continuously. The crops grown in soils to which food waste compost applied showed better growth responses than the control, whereas some variations were observed in the crops grown in chemical fertilizer treated soils. Continuous application of food waste compost increased the contents of organic matter, nitrogen, and phosphorus, which resulted in improving soil aeration.

A Study of Influence of Filgrastim on PET/CT In Diffuse Large B cell Lymphoma (미만성 거대 B 세포 림프종 환자에서 Filgrastim 사용이 PET/CT 영상에 미치는 영향에 대한 고찰)

  • NamKoong, Hyuk;Park, Hoon-Hee;Ban, Yung-Gak;Kang, Sin-Chang;Kim, Sang-Kyoo;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.17-23
    • /
    • 2009
  • Purpose: It has been known that PET/CT is very valuable in follow-up study of diffuse large B cell lymphoma (DLBCL). Generally, in DLBCL, radiotherapy and chemotherapy has been progressed, because the lesion hasn‘t been limited to one site. And, it has lead to the decrease of leukocyte like neutropenia, due to myelosuppression of chemotherapy. So, in that case, administration of Filgrastim (Granulocyte colony-stimulating factor; G-CSF) is universal. However, in short time after administration, PET/CT has limitation to offer accurate images, through the uptake of $^{18}F$-FDG is increased in the region that is activated bone marrow by hematopoietic growth. Therefore, the aim of this study is that PET/CT in a certain period of time after administration of Filgrastim is able to show normal degree of $^{18}F$-FDG uptake. Materials and Methods: 10 patients under follow-up study of diffuse large B cell lymphoma were examined in this study from January, 2007 to January, 2009 (Male: 4 persons; Female: 6 persons; The mean age: 53.8 years old; The mean weight: 57.3 Kg). Using PET/CT (Discovery STe; GE Healthcare, Milwaukee, WI, USA), whole body images were acquired in 1 hour after $^{18}F$-FDG injection. For image analysis, each ROI ($120\;mm^2$) was drawn on $C^6$ (the sixth C-spine), $L_4$ (the forth L-spine), liver, spleen, and lung, then SUV (Standard Uptake Value)s were measured. We compared with each uptake between in 1-day and 5~7 days after administration of Filgrastim at same patient, so confirmed significance about these by SPSS version 12. Results: In case of $C_6$, $L_4$, spleen, every SUV of 1 day later was remarkably higher than that of 5~7 days later, but liver and lung were similar. Also, the images acquired after 5~7 days distinct remarkably and show normal degree of $^{18}F$-FDG uptake, because uptake of bone was almost disappeared. Conclusions: In this study, each SUV was prominent difference as a period of time after Filgrastim’s administration. And Filgrastim makes concentrate uptake of $^{18}F$-FDG in bone, but, after 5~7 days, bone‘s uptake was greatly decreased. Therefore, we are able to infer a certain period of time that shows normal degree of uptake, by numerical value proven. Also, we consider that this study contribute to advanced study about the other agent like Pegfilgrastim, Lenograstim besides Filgrastim, afterwards.

  • PDF

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

Second allogeneic hematopoietic stem cell transplantation in children to overcome graft failure or relapse after initial transplant (조혈모세포이식 후 생착 실패나 재발한 소아환자에서 2차 이식의 의의)

  • Kim, Dong-Yeon;Kim, Do Kyun;Kim, Soo Young;Kim, Seok Joo;Han, Dong Gyun;Baek, Hee Jo;Kook, Hoon;Hwang, Tai-Ju
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.12
    • /
    • pp.1329-1339
    • /
    • 2006
  • Purpose : Failure of hematopoietic stem cell transplantation(HSCT) may be encountered in practice because of either relapse of the malignancy or dysfunction of the graft. Second HSCT may be the only option for some patients whose initial HSCT failed. Methods : From May, 1991 to December, 2004, 115 HSCTs were performed at the Pediatric Blood & Marrow Transplantation Center, Chonnam National University. This study was a retrospective analysis of the medical records of 15 patients who received the second HSCT after initial graft. Results : Among eight patients with nonmalignant diseases, two patients underwent the second HSCT because of primary graft failure and five because of late graft rejection. The remaining Fanconi anemia patient was re-transplanted due to development of AML. Two patients died and one experienced primary graft failure, but is still alive. The Kaplan-Meier 5-year overall survival rate was 75 percent and the disease free survival rate was 62.5 percent in nonmalignant diseases. All malignant patients underwent second transplants because of relapses. Four died of relapse and one of treatment-related complications. The Kaplan-Meier 2-year overall and event free survival rate was 28.6 percent each in malignant diseases. Conclusion : Second HSCT for graft dysfunction of nonmalignant disease seems to be feasible and should be considered as a standard practice. The relapse of malignant diseases remains a big obstacle even after the second HSCT, although a small portion of patients might be salvaged. Further investigation of novel therapeutic strategies, as well an the understanding of the biology should be explored.

Daily Setup Uncertainties and Organ Motion Based on the Tomoimages in Prostatic Radiotherapy (전립선암 치료 시 Tomoimage에 기초한 Setup 오차에 관한 고찰)

  • Cho, Jeong-Hee;Lee, Sang-Kyu;Kim, Sei-Joon;Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.99-106
    • /
    • 2007
  • Purpose: The patient's position and anatomy during the treatment course little bit varies to some extend due to setup uncertainties and organ motions. These factors could affected to not only the dose coverage of the gross tumor but over dosage of normal tissue. Setup uncertainties and organ motions can be minimized by precise patient positioning and rigid immobilization device but some anatomical site such as prostate, the internal organ motion due to physiological processes are challenge. In planning procedure, the clinical target volume is a little bit enlarged to create a planning target volume that accounts for setup uncertainties and organ motion as well. These uncertainties lead to differences between the calculated dose by treatment planning system and the actually delivered dose. The purpose of this study was to evaluate the differences of interfractional displacement of organ and GTV based on the tomoimages. Materials and Methods: Over the course of 3 months, 3 patients, those who has applied rectal balloon, treated for prostatic cancer patient's tomoimage were studied. During the treatment sessions 26 tomoimages per patient, Total 76 tomoimages were collected. Tomoimage had been taken everyday after initial setup with lead marker attached on the patient's skin center to comparing with C-T simulation images. Tomoimage was taken after rectal balloon inflated with 60 cc of air for prostate gland immobilization for daily treatment just before treatment and it was used routinely in each case. The intrarectal balloon was inserted to a depth of 6 cm from the anal verge. MVCT image was taken with 5 mm slice thickness after the intrarectal balloon in place and inflated. For this study, lead balls are used to guide the registration between the MVCT and CT simulation images. There are three image fusion methods in the tomotherapy, bone technique, bone/tissue technique, and full image technique. We used all this 3 methods to analysis the setup errors. Initially, image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours and then the radiation therapist registered the MVCT images with the CT simulation images based on the bone based, rectal balloon based and GTV based respectively and registered image was compared with each others. The average and standard deviation of each X, Y, Z and rotation from the initial planning center was calculated for each patient. The image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours. Results: There was a significant difference in the mean variations of the rectal balloon among the methods. Statistical results based on the bone fusion shows that maximum x-direction shift was 8 mm and 4.2 mm to the y-direction. It was statistically significant (P=<0.0001) in balloon based fusion, maximum X and Y shift was 6 mm, 16mm respectively. One patient's result was more than 16 mm shift and that was derived from the rectal expansions due to the bowl gas and stool. GTV based fusion results ranging from 2.7 to 6.6 mm to the x-direction and 4.3$\sim$7.8 mm to the y-direction respectively. We have checked rotational error in this study but there are no significant differences among fusion methods and the result was 0.37$\pm$0.36 in bone based fusion and 0.34$\pm$0.38 in GTV based fusion.

  • PDF

A Comparative Study on Awareness of Middle School Students, School Parents, and Human Resources Directors in Industrial Institutions about Admission into Specialized High Schools and Career after Graduating from Specialized High Schools (특성화고 진학 및 졸업 후 진로에 대한 중학생, 학부모, 산업체 인사 담당자의 인식 비교 연구)

  • Lee, Byung-Wook;Ahn, Jae-Yeong;Lee, Chan-Joo;Lee, Sang-Hyun
    • 대한공업교육학회지
    • /
    • v.38 no.2
    • /
    • pp.48-67
    • /
    • 2013
  • This study tried to suggest implications about operation direction of specialized high schools (SHS) by researching awareness of middle school students (MSS), school parents (SP), human resources directors in industrial institutions (HRDII) who will be the main users of SHS education, about entering SHS and career after graduating from SHS. Seniors of middle school, SP and HRDII in Asan, Chungnam were the subject of this survey research. The summary of the result of this study is as follow: First, MSS and SP usually hoped to enter general high schools rather than vocational education schools such as SHS, meister high schools, and MSS considered school records and SP considered aptitude and talent for the factors to choose high school. Second, MSS, SP, and HRDII recognized purposes of SHS as improvement of talent and aptitude, and getting a job. As for positive images of SHS, they recognized it as applying talent and aptitude to life early, getting good jobs easily, fast independence after graduation, and learning excellent technologies, and as for negative images of SHS, they recognized it as social prejudices and discrimination, students with bad school records enter them, disadvantages about promotion and wages, and being unfavorable for entering universities. They also recognized education of SHS as being effective for improvement of basic and executive ability and key competency, development of creative human resources, and improvement of right personality and courteous manners. Third, many MSS and SP showed intention to enter SHS if it is established in Asan. They wished to enter SHS because they would like to apply their aptitude and talent to life early, learn excellent skill, and hope for early employment, on the other hand, they did not wish to enter SHS because it was not suited for their aptitude and talent, awareness about SHS is low, it is unfavorable to enter universities, and there were social prejudices and discrimination. They also similarly hoped for getting jobs and entering universities after graduating from SHS. And the reason they wanted to get a job was usually because they want to be successful by advancing into society early, or because it is still hard to get a job even after graduate from the university, on the other hand, the reason they want to enter university is because is usually in-depth education about major and social discrimination about level of education. The ability to perform duties forms the greatest part of the employment standard that MSS, SP, and HRDII aware. MSS and SP usually hoped for industrial, home economics and housework and commercial majors in SHS, and considered aptitude and talent, the promising future, and being favorable for employment for choosing major. The reason HRDII hire SHS student was to develop student into talent of industrial institution, ability of student, and need for manpower with high school graduation level, and there were also partial answer that they can hire SHS student if they have ability to perform duties. The proposals about operation direction of SHS according to the results above are as follow: SHS should diversify major and curriculum to meet various requirements of student and parents, establish SHS admission system based on career guidance, and improve student's ability to perform duties by establishing work-based learning. The Government should organize work-to-school policy to enable practical career development of students from SHS, and promote relevant policy to reinforcing SHS education rather than quantitative evaluation such as employment rate, and cooperative support from each government departments is required to make manpower with skill related to SHS to get proper evaluation and treatment.

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.