• Title/Summary/Keyword: a standard

Search Result 39,679, Processing Time 0.057 seconds

A State Standard and Policy Quality Control (기술사마당 - 국격과 정책품질관리(國格과 政策品質管理))

  • Jung, Byeong Hyun
    • Journal of the Korean Professional Engineers Association
    • /
    • v.46 no.1
    • /
    • pp.58-63
    • /
    • 2013
  • Since 2010, politicians and netizens have been frequently talking about "The Standard of a Nation". Specification/Standard contains "de facto standard" and "de jure standard". "The Standard of a Nation", the level of a state's quality, is prescribed by the constitution. Though the constitution, which is equal to a state's official standard, has been well established, it would be undervalued without civil obedience. The state standard can never be improved by a couple of successful projects or some national policies. The time is that the people who would like to level up of the state standard also should consider technology and science as important.

  • PDF

Building a Rule-Based Goal-Model from the IEC 62304 Standard for Medical Device Software

  • Kim, DongYeop;Lee, Byungjeong;Lee, Jung-Won
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.8
    • /
    • pp.4174-4190
    • /
    • 2019
  • IEC 62304 is a standard for the medical device software lifecycle. Developers must develop software that complies with all specifications in the standard for licensing. However, because the standard contains not only a large number of specifications, but also domain-specific information and association relationships between specifications, it requires considerable effort and time for developers to understand and interpret the standard. To support developers, this paper presents a method for extracting the contents of the IEC 62304 standard as a goal model, which is the core methodologies of requirements engineering. The proposed method analyzes the grammar of the standard to robustly extract complex structures and various information from standard specifications and define rules that extract goals and links from syntactic element units. We validated the actual extraction process for the standard document experimentally. Based on the extracted goal model, developers can intuitively and efficiently comply with the standard and track specific information within the medical software and standard domains.

Thermal and Non-thermal Heat Flow in a Large Crystal Detector for Neutrinoless Double Beta Decay Search

  • Kim, G.B.;Lee, S.J.;Jang, Y.S.;Lee, H.J.;Lee, J.H.;Lee, J.Y.;Lee, M.K.;Yoon, W.S.;Kim, Y.H.
    • Progress in Superconductivity
    • /
    • v.14 no.2
    • /
    • pp.87-91
    • /
    • 2012
  • Metallic magnetic calorimeters (MMCs) are one of the most competitive low temperature detector (LTD) readout sensors. They have the advantages of high time resolution, no heat dissipation, and a wide range of operating temperature. We apply MMCs to our neutrinoless double beta decay ($0v{\beta}{\beta}$) search experiment. A $CaMoO_4$ crystal was employed as both a source of $0v{\beta}{\beta}$ and an energy absorber. The crystal was thermally connected to a MMC sensor. We set a simple thermal model for this detector and measured pulse shapes are compared with a numerical solution of the thermal model.

Establishment of Work and Time Standards in Machining rations including NC Machines (NC기계들이 포함된 기계공작공정에서의 작업연구)

  • 유인선;오근태
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.18 no.33
    • /
    • pp.11-27
    • /
    • 1995
  • This study sets a goal of establishing work standard and standard time in a machine tool process consisted of high-priced NC machine tools. Firstly, the theories of work standard and standard time in the field of NC machine tools are studies. Secondly, the theories are actually applied to a manufacturing company; work standard sheets are developed and applied to a machining center haying low operation rate, and then the increase in productivity is compared. Finally, problems to be studied later in relation to work standard and standard time are presented.

  • PDF

Security Standardization for Social Welfare in the Presence of Unverifiable Control (규제할 수 없는 보안통제가 존재하는 경우 보안 규제 설정)

  • Lee, Chul Ho
    • The Journal of Society for e-Business Studies
    • /
    • v.22 no.2
    • /
    • pp.99-121
    • /
    • 2017
  • Standard makers in both private and public sectors have been increasingly mandating security standards upon organizations to protect organizational digital assets. A major issue in security standardization is that standards often cannot regulate all possible security efforts by the standard maker because some efforts are unverifiable by nature. This paper studies from an analytical perspective how a standard maker should design the standard using a verifiable security control in the presence of another related unverifiable one. We compare it with two benchmark standards; $na{\ddot{i}}ve$-standard which refers to the standard maker who ignores the existence of the unverifiable control, and complete-information standard which refers to the maker sets standards on both controls. Optimal standard and benchmark standard depend critically on how the two controls are configured. Under parallel configuration, the existence of the unverifiable control induces the policy maker to set a higher standard (the complete-information standard is optimal); under serial configuration, a lower standard is applied (neither benchmark works). Under best-shot configuration and if the verifiable control is more cost-efficient, the existence of the unverifiable control has no impact on the optimal standard (the $na{\ddot{i}}ve$ standard is optimal).

A Study on Environmental Standards of School Building (교사환경기준에 관한 연구)

  • Hong, Seok-Pyo;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.1
    • /
    • pp.11-43
    • /
    • 2000
  • The purpose of this study was, through analyzing the previous researches, to grasp the present status of environment of school building(ESB), research the sundry records of each element and, through comparative analysis of the standard of ESB in Korea, the United States, and Japan, select the normative standard of ESB, to clarify the point at issue presented in Regulation of Construction & facility Management for Elementary and and Secondary School in Korea, and to suggest an alternative preliminary standard of ESB. To carry out a research for this purpose, these were required: 1. to investigate the existing present status of ESB, 2. to make a comparative analysis of the standard of ESB in each country, 3. to suggest the normative standard of preliminary standard of ESB, 4. to analyze the controversial points of the standard of ESB in Korea, 5. to suggest an alternative preliminary standard of ESB. The conclusions were as follows: 1. Putting, through analyzing the previous researches, the existing present status of ESB together, it seemed that lighting environment, indoor air environment and noise environment were all in poor conditions. 2. In the result of a comparative analysis of the standard of ESB in Korea, Japan and the United States, in Korea the factors of each lighting and indoor air environment were not presented properly, in Japan, in lighting environment aspect, the standard on natural lighting and the factors on brightness were not presented., and in the USA the essential factors of each environment were throughly presented. In the comparison of the standards on each factor, Korea showed that the standard level presented was less properly prescribed than those of the USA and Japan but it also showed that the standard levels prescribed in the USA and in Japan were mostly similar to the standard levels in records investigated. 3. With the result of the normative standard selection on School Builiding environment factor of prescribed in this study, the controversial points of the standard of ESB in Korea were analyzed and the result was utilized to suggest new preliminary standard of ESB. 4. As the result of the analysis of the controversial points of the standard of ESB in Korea, it was found that the standard of ESB in Korea should be established on a basis of School Health Act and be concretely presented in School Health Regulation and School Health Rule. The factors of each environment was improperly presented in the existing standard of ESB in Korea. Moreover the standard of them was inferior to that of the records investigated and those of in the USA and in Japan and it also showed that the standard of it in Korea was improper to maintain Comfortable Learning Environment. 5. A suggested preliminary standard of ESB acquired through above study as follows: 1) In this study a new kind of preliminary standard of ESB is divided into lighting environment, indoor air environment, noise environment, odor environment and for above classification, reasonable factor and standard should be established and the controling way on each standard and countermeasures against it should be considered. 2) In lighting environment, the factors of natural lighting are divided into daylight rate, brightness, glare. In the standard on each factor, daylight rate should secure 5% of a mean daylight rate and 2% of a minimum daylight rate, brightness ratio of maximum illumination to minimum illumination should be under 10:1, and in glare there should not be an occurrence factor from a reflector outside of the classroom. And the factors of unnatural lighting are illumination, brightness, and glare. In the standard on each factor, illumination should be 750 lux or more, brightness ratio should be under 3 to 1, and glare should not occur. And Optimal reflection rate(%) of Colors and Facilities of Classroom which influences lighting environment should be considered. 3) In indoor air environment factors, thermal factors are divided into (1) room temperature, (2) relative humidity, (3) room air movement, (4) radiation heat, and harmful gases (5) CO, (6) $CO_2$ that are proceeded from using the heating fuel such as oval briquettes, firewood, charcoal being used in most of the classroom, and finally (7) dust. In the standard on each factor, the next are necessary; room temperature: $16^{\circ}C{\sim}26^{\circ}C$(summer : $E.T18.9{\sim}23.8^{\circ}C$, winter: $E.T16.7{\sim}21.7^{\circ}C$), relative humidity: $30{\sim}80%$, room air movement: under 0.5m/sec, radiation heat: under $5^{\circ}C$ gap between dry-bulb temperature and wet-bulb temperature, below 1000 ppm of ca and below 10ppm of $CO_2$, dust: below 0.10 $mg/m^3$ of Volume of dust in indoor air, and ventilation standard($CO_2$) for purification of indoor air : once/6 min.(about 7 times/40 min.) in an airtight classroom. 4) In the standard on noise environment, noise level should be under 40 dB(A) and the noise measuring way and the countermeasures against it should be considered. 5) In the standard on odor environment, odor level under Physical Method should be under 2 degrees, and the inspecting way and the countermeasures against it should be considered.

  • PDF

Comparison of Physicochemical Properties between Standard and Sow Pork

  • Kim, Gye-Woong;Kim, Hack-Youn
    • Food Science of Animal Resources
    • /
    • v.38 no.5
    • /
    • pp.1120-1130
    • /
    • 2018
  • This study was conducted to investigate the dressing percentage and physicochemical characteristics, such as fatty acid composition, water holding capacity (WHC), shear force, meat color, cooking loss, and sensory evaluation, of experimental pork obtained from a total of 12 standard pigs and sows. The water content of tenderloin (73.38%) was the highest in standard pork (p<0.05). A statistically significant difference in crude protein content was shown between standard pork and sow pork (p<0.05). There were significant differences between standard pork and sow pork in shear forces of loin and tenderloin (p<0.01). There was a significant difference in WHC between standard pork and sow pork in loin, tenderloin, and hind legs (p<0.05). The CIE $L^*$ and CIE $b^*$ values of standard loin were significantly higher than those of sow loin (p<0.05). The CIE $a^*$ values of sow loin were significantly higher than those of standard loin (p<0.05). The contents of arachidonic acid for standard pork and sow pork were 0.33% and 0.84%, respectively (p<0.05). However, there was no difference in the total content of unsaturated fatty acid between the two groups. There were no significant differences between standard pork and sow pork after sensory evaluation, except for color and tenderness. The overall acceptability of standard pork was significantly higher than that of sow pork (p<0.05).

Estimating the Optimal Ratio of Standard Pallet Use for Logistics Standardization

  • Hong, Sung-Wook;Lee, Soon-Cheul
    • Journal of Korea Port Economic Association
    • /
    • v.22 no.1
    • /
    • pp.1-15
    • /
    • 2006
  • This paper analyzes how levels of logistics standardization are related to logistics costs. The study surveyed ratios of standard pallet use in order to measure levels of firms' standardization in logistics management. Research focused on how firms' logistics costs were related to their levels of logistics standardization and ratios of standard pallet use. After measuring use of standard pallets and logistics costs, optimal levels of logistics standardization were estimated based on survey data. Logistics costs and standardization were more related to labor than to freight volume or export. Results indicated that firms could reduce logistics costs by raising levels of logistics standardization; optimal levels of standard pallet use out of Korean firms' total manufacturing cargo volume were estimated at 44.26% for multi-standard pallets and 57.99% for a single standard pallet (a unit load system). The study demonstrated that adopting a single standard pallet results in better cost saving logistics systems than use of multi-standard pallet types. These results may explain why firms pursue standardization in logistics systems.

  • PDF

Determining Standard Times of Assembly Products using A Modified BOM (수정 BOM 을 이용한 조립제품의 표준시간 산출)

  • Um, Kwang-Yong;Lee, Moon-Kyu
    • IE interfaces
    • /
    • v.11 no.3
    • /
    • pp.103-114
    • /
    • 1998
  • This paper suggests a computer software system which generates standard times for assembly products. The system called "computer aided logical system for standard times(CALS4ST)" incorporates a modified bill of materials, BOM4ST(BOM for standard time) to deal with auxiliary operations which are not directly related to parts and assemblies listed in the standard BOM. Typical examples of the operations include inspection, adjustment, and repairing works to be done before or after assembly operations. Once standard time data bases for both the part assembly operations and the auxiliary operations are set up, the system relates the BOM4ST to the standard time data bases so as to calculate the standard time for a assembly part concerned. According to the structure of parts and auxiliary operations in the BOM4ST, their standard times stored in the data bases are to be sequentially added up considering the specified assembly-operation characteristics. To illustrate the feasibility of the system, the case study of L company is provided.

  • PDF

A New Set of Capillary Tube Selection Charts for R-22 in Consideration of the Roughness Effect (조도를 고려한 R-22용 모세관 선정 선도)

  • Kim, C.N.;Hwang, U.P.;Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.4
    • /
    • pp.681-693
    • /
    • 1995
  • A new set of capillary tube selection charts for R-22 is proposed. The set of charts takes into account of the roughness effect on the mass flow rate. For this purpose, a set of numerical model is developed and a series of experiments is conducted to verify the numerical model. A numerical model is used to calculated the mass flow rate for several sets of tube diameter, length, inlet pressures and degree of subcooling. The outlet of the tube is controlled to be at critical condition. The experimental flow rate is compared with calculated values. The calculated values are consistently less than the experimental ones except for the flow rate range below 40kg/hr. The deviation is within 10---. Based on the nunmerical model and results of experiments, the set of capillary tube selection charts for R-22 is constructed. The set of charts consists of standard capillary tube chart(L=2030mm, d=1.63mm, ${\varepsilon}=2.5{\mu}m$), non -standard flow factor(${\phi}_1$) chart, and non-standard roughness factor(${\phi}_2$) chart. The mass flow rate, flow factor, and the roughness factor are defined respectively as; $\dot{m}={\phi}_1{\phi}_2\dot{m}_{standard}\\{\phi}_1=\frac{\dot{m}(L,\;d,\;\varepsilon_{standard})}{\dot{m}_{standard}(L_{standard},\;d_{standard},\;{\varepsilon}_{standard})}\\{\phi}_2=\frac{\dot{m}(L_{standard},\;d_{standard},\;{\varepsilon})}{\dot{m}_{standard}(L_{standard},\;d_{standard},\;{\varepsilon}_{standard})}$.

  • PDF