• 제목/요약/키워드: a scan conversion

검색결과 75건 처리시간 0.024초

유사 조합 회로로의 변환에 기초한 부분 스캔 기법을 이용한 디지털 순차 회로의 테스트 기법 연구 (Test Generation of Sequential Circuits Using A Partial Scan Based on Conversion to Pseudo-Combinational Circuits)

  • Min, Hyoung-Bok
    • 대한전기학회논문지
    • /
    • 제43권3호
    • /
    • pp.504-514
    • /
    • 1994
  • Combinational automatic test pattern generators (CATPG) have already been commercialized because their algorithms are well known and practical, while sequential automatic test pattern generators(SATPG) have been regarded as impractical because they are computationally complex. A technique to use CATPG instead of SATPG for test generation of sequential circuits is proposed. Redesign of seauential circuits such as Level Sensitive Scan Design (LSSD) is inevitable to use CATPG. Various partial scan techniques has been proposed to avoid full scan such as LSSD. It ha sbeen reported that SATPG is required to use partial scan techniques. We propose a technique to use CATPG for a new partial scan technique, and propose a new CATPG algorithm for the partially scanned circuits. The partial scan technique can be another choice of design for testability because it is computationally advantageous.

  • PDF

3차원 인체스캔형상을 재현한 3D 아바타 제작을 위한 가상착의 시스템의 활용성 검증 -CLO 3D 프로그램을 중심으로- (Usability verification of virtual clothing system for the production of a 3D avatar reproduced from 3D human body scan shape data - Focusing on the CLO 3D program -)

  • 홍은희
    • 한국의상디자인학회지
    • /
    • 제22권1호
    • /
    • pp.1-13
    • /
    • 2020
  • The purpose of this study is to create a 3D avatar from 3D human body shape data using the CLO 3D virtual clothing program and to verify the feasibility of avatar production using the virtual clothing system for verifying size and shape. The research method was to select one virtual representative model that is the closest to the mean size of each body item for each age group. Using the 3D human body scan shape of a 40-69 years old male was applied to the CLO 3D virtual wearing system. Using the CLO 3D Avatar conversion menu, we verified the feasibility of creating a 3D avatar that reproduces the human body scan shape. In the dimension comparison between the 3D avatar and the fictitious representative model, the dimension difference was noticeable in height, circumference, and length. However, as a result, the converted 3D avatar showed less than a 5% difference in most human dimensions. In addition, since the body shape and posture were reproduced similarly, the utilization of the avatar was verified.

CRT-02: Television Sets with Ultra-Slim Transposed Scan CRTs

  • Wesenbeeck, R.J. Van;Bosma, M.;Heynderickx, I.;Krijn, M.P.C.M.;Mastenbroek, E.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.347-350
    • /
    • 2002
  • Transposed scan is an innovation that paves the road to ultra-slim CRTs with deflection angles up to 135$^{\circ}C$ We discuss the integration of video transposition with the other video processing functions in the television set. An in-place transposition algorithm which minimizes the amount of frame memory is proposed as a low-cost solution for transposed scan conversion. The difference in visual perception of transposed scan and normal scan depends on the frame rate and the line density of the video format. We found that for high frame rates and high line densities, no difference was perceived for both scan modes.

  • PDF

적외선 센서를 이용한 열상장비의 구현 (Thermal Imager Implementation Using Infrared Sensor)

  • 유위경;윤은숙;김창우;송인섭;홍석민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1250-1254
    • /
    • 1992
  • This paper describes the designed and fabricated thermal imaging system with the SPRITE(Signal PRocessing in The Element) detector, operating in the 3-12 micron band. This system consists of an afocal telescope, a scan unit containing the SPRITE detector, an electronic processor unit and a cooler. The optical scan system utilizing rotating polygon and oscillating mirror, is 2-dimensional serial/parallel scan type using five elements of the detector. And the electronic processor unit performs digital scan conversion to reform the parallel data stream into serial analog data compatable with conventional RS-170 video. The scan field of view is 40 ${\times}$ 26.7 and the MRTD(Minium Resolvable Temperature Difference) is 0.6 K at 7.5 cycles/mm. The acquired thermal image indicates that this system has a satisfactory performance.

  • PDF

효율적인 클리핑 기능을 갖는 3차원 그래픽 파이프라인 구조 (A 3D graphic pipelines with an efficient clipping algorithm)

  • 이찬호
    • 대한전자공학회논문지SD
    • /
    • 제45권8호
    • /
    • pp.61-66
    • /
    • 2008
  • 최근 모바일 기기에 3차원 그래픽 디지털 콘텐츠들이 증가함에 따라 휴대용 기기에 적합한 3차원 그래픽 가속기의 연구와 설계는 점점 중요한 이슈가 되고 있다. 본 논문에서는 저전력 3차원 그래픽 파이프라인에 적합한 효율적인 클리핑 구조를 제안한다. 많은 연산 사이클과 연산기를 필요로 하는 클리핑 연산을 두 단계로 나누어서 기하변환 엔진에서는 컬링 정렬(cull and sort) 유닛으로 구현하고, 실질적인 클리핑은 스캔 변환(scan conversion)에서 구현한다. 즉, 스캔 변환 처리기를 구성하고 있는 변처리 (edge walk) 유닛에서 Y축 클리핑을 함께 수행하고 스팬처리 (span processing) 유닛에서 X축과 Z축 클리핑을 함께 수행한다. 제안하는 기하 변환 엔진의 컬링 정렬 유닛은 기존 클리핑 유닛에 비해 면적과 동작 사이클이 크게 줄었고 스캔 변환 처리기의 면적은 거의 증가하지 않아 전반적으로 동작 속도 및 동작 효율을 높였다. 제안하는 클리핑 구조를 적용한 3차원 그래픽 가속기는 Verilog-HDL을 이용하여 설계하고 FPGA를 이용하여 검증하였다.

ESI-MS/MS를 이용한 아실카르니틴과 아미노산의 정량분석 (Quantitative Analysis of Acylcarnitines and Amino Acids Using ESI-MS/MS)

  • 김호현;한상범;윤혜란
    • 분석과학
    • /
    • 제14권5호
    • /
    • pp.384-391
    • /
    • 2001
  • 본 연구에서는 ESI-MS/MS를 이용해 혈액내에서 아실카르니틴과 아미노산을 신속하게 정량분석하는 방법을 개발하였다. 아실카르니틴과 아미노산은 3N butanolic hydrogen chloride를 사용하여 유도체화 과정을 거친 뒤 이중질량분석기로 분석하였다. 아실카르니틴은 precursor 85 ion scan을 사용하여 분석하였고, 아미노산들중 알라닌, 발린, 루신/이소루신, 메티오닌, 페닐알라닌, 타이로신, 아스파르트산, 글루탐산 등은 neutral loss 102 scan, 오르니틴과 시트롤린은 neutral loss 119 scan, 글리신은 neutral loss 56 scan, 아르기닌은 neutral loss 161 scan 그리고 아르기니노석시닉산은 product ion 459 scan을 사용하여 분석하였다. 이 방법은 일반적인 액체 크로마토그래피나 아미노산 분석기에 비해서 시료의 전처리가 비교적 간단하며, 높은 감도와 좋은 재현성을 보여주었다.

  • PDF

3차원 인체형상 스캔데이터를 이용한 남자 바지패턴 설계 (Development of Men Slacks Pattern Using 3D Scan Data)

  • 손부현
    • 대한가정학회지
    • /
    • 제46권9호
    • /
    • pp.137-146
    • /
    • 2008
  • This study was conducted in order to spread out lower body 3D scan data of men in their twenties. The aim was to achieve slacks pattern with ease allowance through comparison with existing flat patterns. For conversion of 3D scan data into 20 pattern, reference lines were established by using Rapid Foam in 3D shape analysis software. 2C-AN program and Yuka CAD were used to convert 20 pattern earned with straight posture of 3D scan data into slacks pattern by using Triangle Simplification & Runge-Kutta Method. In order to achieve this we needed to set a line 9cm below the hip line, to array vertex of each block to crease line while maintaining the horizontal line. And then we needed to set ease allowance in back crotch and to set waist circumference or hip circumference ease allowance in side seam of slacks. Results showed that long front crotch length can be achieved if 3D scan data is compared with 20 existing flat pattern. Slacks pattern that raise front crotch by about 1.5cm compared to back crotch and also possess ease allowance in back crotch area are great in appearance evaluation.

Determination of Optimal Scan Time for the Measurement of Downstream Metabolites in Hyperpolarized 13C MRSI

  • Lee, Hansol;Lee, Joonsung;Joe, Eunhae;Yang, Seungwook;Choi, Young-suk;Wang, Eunkyung;Song, Ho-Taek;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권4호
    • /
    • pp.212-217
    • /
    • 2015
  • Purpose: For a single time-point hyperpolarized $^{13}C$ magnetic resonance spectroscopy imaging (MRSI) of animal models, scan-time window after injecting substrates is critical in terms of signal-to-noise ratio (SNR) of downstream metabolites. Pre-scans of time-resolved magnetic resonance spectroscopy (MRS) can be performed to determine the scan-time window. In this study, based on two-site exchange model, protocol-specific simulation approaches were developed for $^{13}C$ MRSI and the optimal scan-time window was determined to maximize the SNR of downstream metabolites. Materials and Methods: The arterial input function and conversion rate constant from injected substrates (pyruvate) to downstream metabolite (lactate) were precalibrated, based on pre-scans of time-resolved MRS. MRSI was simulated using two-site exchange model with considerations of scan parameters of MRSI. Optimal scan-time window for mapping lactate was chosen from simulated lactate intensity maps. The performance was validated by multiple in vivo experiments of BALB/C nude mice with MDA-MB-231 breast tumor cells. As a comparison, MRSI were performed with other scan-time windows simply chosen from the lactate signal intensities of pre-scan time-resolved MRS. Results: The optimal scan timing for our animal models was determined by simulation, and was found to be 15 s after injection of the pyruvate. Compared to the simple approach, we observed that the lactate peak signal to noise ratio (PSNR) was increased by 230%. Conclusion: Optimal scan timing to measure downstream metabolites using hyperpolarized $^{13}C$ MRSI can be determined by the proposed protocol-specific simulation approaches.

Tracking and Deflection Coil Design for Vertical Colour Selection

  • Wesenbeeck, R. Van;Skoric, B.;Ijzerman, W.;Krijn, M.;Engelaar, P.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.130-133
    • /
    • 2003
  • Vertical Colour Selection (VCS) is an option for slim CRTs with increased sharpness and brightness. The direction of self-convergence of the DY is changed to vertical in order to obtain better spot uniformity, but the line scan direction remains horizontal. Hence, no video conversion is needed, contrary to transposed scan. In this paper we address two issues: First, there is a high risk of moire, since the scan lines and the phosphor stripes are parallel. We propose a feedback mechanism guiding the electron beams towards the middle of the mask slots. As positive side effects, the brightness is improved and the shadow mask can be made of a cheap type of steel. Secondly, VCS deflection coils have to satisfy different requirements than coils in ordinary CRTs. We discuss the design rules for self-convergent VCS coils and present simulation results.

  • PDF

직병렬 주사방식 일정장비의 신호처리기 설계 연구 (Electronic Processor Design for Thermal Imager with Serial/Parallel Scan type)

  • 송인섭;유위경;윤은석;홍영철;홍석민
    • 전자공학회논문지B
    • /
    • 제31B권1호
    • /
    • pp.49-56
    • /
    • 1994
  • This paper describes the design principles and methods of electronic processor for thermal imager with the SPRITE detector, operating in the 8-12 micron band. The thermal imager consists of a optical scanner containing the detector and an electrical signal processor. The optical scanner utilizing rotating polygon and oscillating mirror, is 2-dimensional serial/parallel scan type using 5 elements of the detector. And the electronic processor has pre-processing of 5 chnanel's thermal signal from the detector, and performs digital scan conversion to reform the parallel data stream into serial analog data compatible with conventional RS-170 video. Through the designed electronic processor, we have acquired a satisfactory thermal image. And the MRTD (Minimum Resolvable Temperature Difference) is 0.5$^{\circ}$K at 7.5 cycles/mm.

  • PDF