• Title/Summary/Keyword: a rest

Search Result 4,398, Processing Time 0.035 seconds

Comparison of $^{99m}Tc-MIBI$ Myocardial Uptake at Rest with Reinjection and 24-hour after Reinjection Images of $^{201}Tl$ ($^{201}Tl$$^{99m}Tc-MIBI$에 의한 생존심근의 진단 비교 -재분포영상에 고정관류결손을 보인 환자에서 $^{201}Tl$ 재주사법 및 $^{99m}Tc-MIBI$ 휴식기스캔에 의한 심근섭취 비교-)

  • Bom, Hee-Seung;Kim, Ji-Yeul;Park, Joo-Hyung;Ahn, Young-Keun;Jeong, Myung-Ho;Cho, Jeong-Gwan;Park, Jong-Choon;Kang, Jung-Chaee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.274-279
    • /
    • 1992
  • Clinical role of $^{99m}Tc-MIBI$ myocardial scintigraphy in the diagnosis of coronary artery disease (CAD) is now well accepted, however, the role of it in the identification of viable myocardium in patients with chronic CAD has not yet been clarified. To determine the usefulness of rest-injected $^{99m}Tc-MIBI$ scan as a marker of myocardial viability, the regional uptake of this agent at rest was compared with that of $^{201}Tl$ on reinjection and 24 hours after reinjection images. Subject patients were 13 chronic CAD patients who showed irreversible perfusion defect(s) on standard pharmacologic (dipyridamole) stress-redistribution images. Immediately after the redistribution images were obtained, 37 MBq thallium was injected at rest, and images were reacquired at 10 minutes and 24 hours after reinjection. After then 740 MBq $^{99m}Tc-MIBI$ was injected, and 1 hour later rest MIBI myocardial imaging was performed. Five sets of imagestress, redistribution, reinjection, delayed images of thallium, and rest image of MIBI) were then analyzed qualitatively and quantitatively. Left ventricle was arbitrarily divided into 9 segments (apex, basal and apical portions of anterior, septal, inferior, and lateral walls). Seven patients and 30 regions showed a fixed perfusion defect on the stress-redistribution images. Among 30 regions, 15 showed positive uptakes and 6 showed negative uptakes on both $^{201}Tl$ reinjection/delayed images and $^{99m}Tc-MIBI$ rest images. Five regions showed only thallium uptake and were regarded as viable clinically. Of four regions which showed only $^{99m}Tc-MIBI$ uptake, two were regarded as viable, while the other two were regarded as a nonviable scar tissue clinically. In conclusion, $^{201}Tl$ reinjection technique was more reliable in the identification of viable myocardium. However, the role of $^{99m}Tc-MIBI$ in identification of viable myocardium was still remained to be clarified because 2 of 9 regions showed only $^{99m}Tc-MIBI$ uptake and were regarded as viable tissues.

  • PDF

An Empirical Study on the Application of Lead-Acid Batteries to ESSs and Performance Improvement Methods

  • Jung, Hyun-Chul;Heo, Hoon
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1295-1304
    • /
    • 2015
  • In this paper, an approach to extend the life of lead-acid batteries through the elimination of sulfation with "rest time" using the pulse current of a conventional DPV (Differential Pulse Voltammetry) method is discussed. A new rest time without "0" current in "saw-tooth" pattern pulses is proposed to overcome the "0" current (blackout period), which is a shortcoming of DPV. This will enable the proposed method to be used in the loaded state. In the proposed approach, ESSs (Energy Storage Systems) were discharged for 5 h twice per day for 6 months on weekdays. To observe the changes in the lifespan of the systems, for the same period, the changes in the impedances of lead-acid batteries which were being charged e without charging and discharging were measure and compared. This study is focused on determining the effectiveness of lead-acid batteries as ESSs.

A Log Analysis System with REST Web Services for Desktop Grids and its Application to Resource Group-based Task Scheduling

  • Gil, Joon-Min;Kim, Mi-Hye
    • Journal of Information Processing Systems
    • /
    • v.7 no.4
    • /
    • pp.707-716
    • /
    • 2011
  • It is important that desktop grids should be able to aggressively deal with the dynamic properties that arise from the volatility and heterogeneity of resources. Therefore, it is required that task scheduling be able to positively consider the execution behavior that is characterized by an individual resource. In this paper, we implement a log analysis system with REST web services, which can analyze the execution behavior by utilizing the actual log data of desktop grid systems. To verify the log analysis system, we conducted simulations and showed that the resource group-based task scheduling, based on the analysis of the execution behavior, offers a faster turnaround time than the existing one even if few resources are used.

A Literature Study on the Functional Change of 'Jeong(亭)' in Korea and China (한국과 중국에서 '정(亭)' 건축 기능의 변화에 대한 문헌적 고찰)

  • Lee, Joung-Ah
    • Journal of architectural history
    • /
    • v.33 no.1
    • /
    • pp.33-43
    • /
    • 2024
  • In Korea, the function of Jeong(亭), Jeongja(亭子), and Nujeong(樓亭) architecture is essentially rest. However, in China, where the name Jeong was first coined and used, Jeong was not only used as a place of rest, but also for a variety of functions depending on the time and region, such as building units for guard posts, policing, and mail delivery. But why is it that in Korea, Jeong is primarily perceived and used as place of rest? Starting from this question, this article examines the historical process of the emergence of Jeong and its changing functions, focusing on the official history of China, and then examines the perception of Jeong in Korea through its connection to the dominant function of Jeong in China during the period of Jeong's emergence in Korean literature. This will help us to fundamentally understand the differences between Jeong architecture in Korea and Jeong architecture in China, and to further clarify the historical significance of the types of Jeongja and Nujeong architecture in Korea.

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE MANDIBULAR CANTILEVERED PROSTHESIS SUPPORTED BY IMPLANTS (임프란트로 지지된 하악 켄티레버 보철물의 3차원 유한요소 분석)

  • Cho, Chul;Shin, Sang-Wan;Kwon, Jong-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.724-743
    • /
    • 2000
  • One of the biggest clinical problems of osseointegrated implant prosthesis is the excessive stress caused by bite forces which are transfered directly into the bone through the osseointegrated implant fixtures. So several biodynamic problems occur when there is an excessive fatigue stress. The factors of stress distribution are the number, kind, position, arrangement of the implants, and the distance between the implants, and the kind, quality of superstructure prosthesis and connection type between the rest implant and the superstructure. Recently, a distal short additional implant, socalled rest implant, is employed to reduced the stresses in conventional cantilevered prostheses. This study was undertaken to analyze the stresses transfered by osseointegrated implant cantilevered prostheses depending upon the number and the position of implants, the presence of rest implant, and the type of their connection. Three dimensional finite element analysis was attempted using ANSIS ver. 5.3 program under IBM INDIGO computer. The results were as follows : 1. The rest implant influenced on the pattern of stress distribution on the anterior area of the mandible and the superstructure. 2. In the group employing the rest implants, the fixed type of connection between the rest implant and the superstructure was more stable than the ball attachment type on the stress distribution. 3. In the group employing the ball attachment between the rest implant and the superstructure, the case with 4-implants(on canine, premolar) was little more stable than the case with 6-implants and the case with 4-implants(on incisor, premolar) on the stress distribution. 4. In the cantilevered group, the case with 4-implants(on incisor, premolar) and the case with 6-implants were more stable than the case with 4-implants(on canine, premolar) on the stress distribution. 5. In all of the group, the case with 6-implants and the fixed type of connection was the most stable and the case with 4-implants (on canine, premolar) was the most unstable on the stress distribution.

  • PDF

Electroencephalographic brain frequency in athletes differs during visualization of a state of rest versus a state of exercise performance: a pilot study

  • Berk, Lee;Mali, Deeti;Bains, Gurinder;Madane, Bhagwant;Bradburn, Jessica;Acharya, Ruchi;Kumar, Ranjani;Juneja, Savleen;Desai, Nikita;Lee, Jinhyun;Lohman, Everett
    • Physical Therapy Rehabilitation Science
    • /
    • v.4 no.1
    • /
    • pp.28-31
    • /
    • 2015
  • Objective: Psychomotor imagery has been widely used to improve motor performance and motor learning. Recent research suggests that during visualization, changes occur in neurophysiological networks that make physical practice more effective in configuring functional networks for skillful behaviors. The aim of our pilot study was to determine if there was change and to what extent there was differentiation in modulation in electroencephalography (EEG) frequencies between visualizing a state of rest and a state of exercise performance and to identify the preponderant frequency. Design: Quasi-experimental design uncontrolled before and after study. Methods: EEG brain wave activity was recorded from 0-40 Hz from nine cerebral cortical scalp regions F3, Fz, F4, C3, Cz, C4, P3, POz, and P4 with a wireless telemetric EEG system. The subjects, while sitting on a chair with eyes closed, were asked to visualize themselves in a state of routine rest/relaxation and after a period of time in a state of their routine exercise performance. Results: The gamma frequency, 31-40 Hz, (${\gamma}$) was the predominant wave band in differentiation between visualizing a state of rest versus visualizing a state of exercise performance. Conclusions: We suggest these preliminarily findings show the EEG electrocortical activity for athletes is differentially modulated during visualization of exercise performance in comparison to rest with a predominant ${\gamma}$ wave band frequency observed during the state of exercise. Further controlled experimental studies will be performed to elaborate these observations and delineate the significance to optimization of psychomotor exercise performance.

The Correlation Analysis of Ejection Fraction: Comparison of $^{201}Tl$ gated Myocardial Perfusion SPECT and Echocardiography ($^{201}Tl$ 게이트 심근관류 SPECT 및 심초음파의 좌심실 구혈률 상관관계 비교)

  • Yoon, Soon Sang;Ryu, Jae Kwang;Cha, Min Kyung;Lee, Jong Hun;Kim, Sung Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.49-56
    • /
    • 2012
  • Purpose : Gated myocardial perfusion SPECT provides not only myocardial perfusion status, but various functional parameters of left ventricle (LV). The purpose of this study was to analyze ejection fraction (EF) for correlation and difference between $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography depending on extent of perfusion defect, gender and LV volumes. Materials and Methods : From April 2011 to May 2012, we analyzed 291 patients (male:female =165:126; mean: $64.6{\pm}10.8$ years) who were examined both $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography at less than 7 days apart in our hospital. 101 patients showed perfusion defect and the rest of the people without any defect. We applied automatic analysis (Quantitative gated SPECT, QGS), and calculated EF, End-diastolic volume (EDV) and End-systolic volume (ESV) from Stress (G-Stress) and Rest (G-Rest) studies. And we analyzed the correlation and difference for EF between $^{201}Tl$ gated SPECT and echocardiography. Results : The correlation of LVEF among G-Stress, G-Rest and echocardiography was quite a good (G-Stress vs. G-Rest: r=0.909, G-Stress vs. echocardiography: r=0.833, G-Rest vs. echocardiography: r=0.825). And there were significant differences in EDV, ESV and EF in total patients (p<0.01). The normal group showed significant difference in EF (p<0.01) and the group with perfusion defect also demonstrated significant difference (a group with reversible defect: p<0.01, fixed defect: p<0.01) depending on extent of perfusion defect. We analyzed difference in normal group by gender. In normal group, there was no significant difference (p>0.05) in EF from men. However, there was a significant difference (p<0.01) from women. When we classified two groups by average size of EDV in Korean women, there was no significant difference in a group of above average size of EDV (p>0.05). Conclusion : When compared among Stress and Rest of $^{201}Tl$ gated SPECT and echocardiography, we confirmed that there was a good correlation for LVEF. But there were significant differences among three studies. And extent of perfusion defect, gender and LV volumes are independent determinants of the accuracy of LVEF. So, it is hard to compare and interchange quantitative indices among modalities. We should take additional researches to prove results of our study.

  • PDF

A Study on Evaluation of Human Arousal Level using PPG Analysis (PPG(Photoplethysmography)분석을 이용한 각성도 평가에 관한 연구)

  • Kim, Chi-Jung;Whang, Min-Cheol;Kim, Jong-Hwa;Woo, Jin-Cheol;Kim, Yong-Woo;Kim, Ji-Hye
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.113-120
    • /
    • 2010
  • This research is to evaluate the arousal level by using cardiovascular response. PPG was used in this study as one of the method of measuring it rather than ECG (Electrocardiography) for the purpose of solving ergonomic problem of sensing. The participants were in the age group of 20 (mean=24, standard deviation=1.25): five men and five women. Each experiment composed with four identical sets. First, a black screen was displayed for 30 second rest. Then, the prepared 6 pair images were randomly presented for 10 second stimulation and for 30 second non-stimulation. PPG was measured on the earlobes of experimenters at 200Hz sampling frequency. PPG amplitude, PPI(Pulse to Pulse Interval), and PRV(Pulse Rate Variability) were analyzed according to arousal level. T-test was performed to compare between the PPG variables of rest and relaxation, rest and arousal, and relaxation and arousal. Relative to the rest state, PPG amplitude decreased in relaxed state and increased in aroused state. Relative to the rest state, PPI decreased in both emotional states. However, more significant decline was observed in aroused state. PRV's LF and HF were used in the form of LF/HF to compare between the relaxed and the aroused state. Therefore, PPG signal showed significant differences between relaxed and aroused state. In conclusion, evaluation of human arousal level used in the PPG analysis demonstrated that PPG has better usability and comforter measurement than ECG and is clearly an alternative method of measuring arousal level.

Implementation of Accessibility and Usability Enhancement Scheme for a WebRTC VC Application (WebRTC VC응용의 접근성 및 편의성 향상기술 구현)

  • Lee, KyoungMin;Jo, Jinyong;Kong, JongUk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.8
    • /
    • pp.1478-1486
    • /
    • 2016
  • This paper introduces technical methods to improve the accessibility and usability of a WebRTC video conference (VC) application. Simplified login is essential, by applying such as single sign-on (SSO) to improve the accessibility of VC applications. High usability and manageability are also necessary to attract more users, enhance user experiences, and save service management cost. The proposed VC application leverages SAML-based federated identity management (FIM) to enable higher service accessibility. Users can access the application with their organizational ID and SSO authentication. The FIM eases user ID management and indirectly strengthens privacy information protection. Proposed web application has high usability and manageability because users and/or administrators can easily create, join, monitor, or tear down VC sessions through RESTful web service (REST API). We verify the feasibility of the VC application after illustrating the SAML-based identity federation and the designed REST API.

Design of Indoor Location-based IoT Service Platform

  • Kim, Bong-Han
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.12
    • /
    • pp.231-238
    • /
    • 2022
  • In this paper, among short-range wireless communication technologies such as Beacon, Bluetooth, UWB (Ultra-wideband), ZigBee, NFC (Near Field Communication), Z-Wave, 6LoWPAN (IPv6 over Low power WPAN), D2D (Device to Device), etc., proposed an IoT service platform based on a beacon that can provide indoor positioning. And, a beacon-linked web server was designed by blocking indiscriminate beacon spam signals and applying REST web service technology with flexibility and scalability. Data accessibility between different devices was verified by testing the success rate of data transmission, the success rate of blocking beacon push, the success rate of IoT interlocking processing, the accuracy of location positioning, and the success rate of REST web service-based data processing. Through the designed IoT service platform, various proposals and research on short-distance-based business models and service platforms will be conducted in the future.