• Title/Summary/Keyword: a optic fiber

Search Result 888, Processing Time 0.031 seconds

Protection System Against The Infringement of Information Signals in Fiber Communication System (광섬유 통신 시스템의 정보 신호 침해에 대한 보호 시스템)

  • Ugli, Sobirov Asilzoda Alisher;Umaralievich, Nishonov Ilhomjon;Kim, Daeik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.2
    • /
    • pp.219-228
    • /
    • 2022
  • One of the most pressing and demanding issues today in the conditions of widespread transformation and digitalization of spheres of human activity is information security and ensuring the integrity of data. The main research and development in the field of information security is aimed at improving efficiency and rationalization. One of the main means of data transmission and operation of information complexes are fiber-optic systems. To date, there have been incidents of illegal intrusion and theft of information, passing through this type of communication. Thus, today there is a problem associated with insufficient information security in fiber-optic data transmission systems. One of the most effective tools to counter acts of illegal interference in systems are artificial intelligence and cryptographic algorithms of information protection. It is the symbiosis of these two tools that can qualitatively improve the level of information security in fiber-optic data transmission systems. Thus, the authors of this article pursue the goal associated with the description of an innovative system for protecting information from violations in fiber-optic data transmission systems based on the integration of intelligent cryptographic algorithms.

Development of optical temperature distribution measurement system for Underground Power Transmission tunnel (지중선로의 분포 온도 측정 시스템 개발)

  • Lee, Keun-Yang;Song, Woo-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.766-768
    • /
    • 1998
  • Optical Temperature Distribution measurement System (OTDS) is completely different from conventional electric point sensor in that it uses the optical fiber itself as the sensor. This new concept in temperature measuring system requires only one fiber to be laid. The use of optical fiber also gives the advantage of small diameter, light weight, explosion resistance, and electromagnetic noise resistance. The OTDS is a sensor which is capable of making a precise measurement over a wide range of areas using only a single optical fiber. Since current temperature sensors, such as the thermocouple, are only used to measure temperaturea of point, they are almost impractical for measuring a wider range because of the extremely high cost. In comparision with current sensors, the optical fiber distributed temperature sensor can make much quicker and more precise measurements at a comparatively low cost.

  • PDF

Common-path Optical Coherence Tomography for Biomedical Imaging and Sensing

  • Kang, Jin-U.;Han, Jae-Ho;Liu, Xuan;Zhang, Kang
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.1-13
    • /
    • 2010
  • This paper describes a development of a fiber optic common-path optical coherence tomography (OCT) based imaging and guided system that possess ability to reliably identify optically transparent targets that are on the micron scale; ability to maintain a precise and safe position from the target; ability to provide spectroscopic imaging; ability to imaging biological target in 3-D. The system is based on a high resolution fiber optic Common-Path OCT (CP-OCT) that can be integrated into various mini-probes and tools. The system is capable of obtaining >70K A-scan per second with a resolution better than $3\;{\mu}m$. We have demonstrated that the system is capable of one-dimensional real-time depth tracking, tool motion limiting and motion compensation, oxygen-saturation level imaging, and high resolution 3-D images for various biomedical applications.

Measurement and removal of a cerenkov light in a plastic optical fiber to detect a scintillating light (섬광검출을 위한 플라스틱광섬유에서의 체렌코프 빛 측정 및 제거)

  • Cho, Dong-Hyun;Jang, Kyoung-Won;Yoo, Wook-Jae;Shin, Sang-Hun;Lee, Bong-So;Park, Byung-Gi;Cho, Hyo-Sung;Kim, Sin
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.100-105
    • /
    • 2008
  • The objectives of this study are to measure and to remove Cerenkov lights generated in a fiber-optic radiation sensor by a charge-coupled device. we have fabricated a fiber-optic radiation sensor which comprises an organic scintillator, a plastic optical fiber and a charge-coupled device. Charge-coupled device as a light measuring tool has many advantages which are easy in multi-dimensional measurements, high spatial resolution and relatively low cost.

Measurement of Skin Dose and Percentage Depth Does in Build-up Region Using a Fiber-optic Dosimeter (광섬유 방사선량계를 이용한 선량보강 영역에서의 심부선량 백분율과 피부 선량률 측정)

  • Cho, Dong-Hyun;Jang, Kyoung-Won;Yoo, Wook-Jae;Seo, Jeong-Ki;Heo, Ji-Yeon;Lee, Bong-Soo;Cho, Young-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.1
    • /
    • pp.16-20
    • /
    • 2010
  • In this study, we have fabricated a fiber-optic dosimeter using an organic scintillator and a plastic optical fiber. The dosimeter measure skin dose and percentage depth dose in a build-up region for an incident high energy photon beam. The scintillating light generated in the organic sensor probe embedded in a solid water phantom is guided by 30 m plastic optical fiber to a light-measuring device such as a PMT or an electrometer. In addition, using a fiber-optic dosimeter or a GAFCHROMIC EBT film, skin dose and percentage depth dose in the build-up region are measured and compared.

Measurement of relative dose irradiated from a Co-60 source using a scintillating fiber-optic dosimeter (광섬유 방사선량계를 이용한 Co-60 방사선원으로부터 조사되는 상대선량측정)

  • Jang, Kyoung-Won;Cho, Dong-Hyun;Yoo, Wook-Jae;Seo, Jeong-Ki;Heo, Ji-Yeon;Lee, Bong-Soo;Shin, Sang-Hun;Park, Byung-Gi;Kim, Sin
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.52-57
    • /
    • 2010
  • In this study, we have fabricated a scintillating fiber-optic dosimeter for a radiotherapy dosimetry. And ${\gamma}$-rays generated by a Co-60 are measured using a scintillating fiber-optic dosimeter and percent depth dose curves are obtained according to the different depths of solid water phantoms. Also, Cerenkov radiations generated by primary or secondary electrons are measured at different depths of water phantom using a background optical fiber.

Visualization of Gas/liquid Ejector Flow and Void Fraction Measurement using Fiber Optic Probe (기체-액체 이젝터 유동의 가시화와 광섬유 탐침에 의한 기포분율 측정)

  • Choi, Sung Hwan;Ji, Ho Seong;Kim, Kyung Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.11 no.1
    • /
    • pp.34-40
    • /
    • 2013
  • Gas/liquid two-phase ejector is a device without moving parts, in which liquid is used to drive gas of a low-pressure source. In this paper, the hydrodynamic characteristics of a vertical down type two-phase ejector were studied using an air-water loop system. Entrained air flow rates were measured with inlet and outlet pressures of the ejector with varying water flow rate. Homogeneous bubbly flows in the discharge pipe were confirmed by the high speed flow visualization method. Quantitative measurements of void fraction were made using a newly developed fiber optic probe system.

FIBER OPTIC SENSOR FOR IN-SITU AND REALTIME MONITORING OF TRANSPORT OF GAS PHASE OZONE IN UNSATURATED POROUS MEDIA

  • Jung, Hae-Ryong;Park, Hee-Chul
    • Environmental Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.71-78
    • /
    • 2005
  • A series of column experiments was conducted to develop a monitoring system for in-situ and realtime measurement of ozone transport in unsaturated porous media using a fiber optic sensor. The calibration of the fiber optic transflection dip probe (FOTDP) system was successfully carried out at various ozone concentrations using a column with length of 30 cm and diameter of 5 cm packed with glass beads, which don't react with gaseous ozone. The breakthrough curves (BTCs) of ozone were obtained by converting the normalized intensity into ozone concentration. The FOTDP system worked well for in-situ monitoring of gas phase ozone at various water saturations and in presence of soil organic matter (SOM). However, the FOTDP system did not measure the ozone concentration at more than 70% water saturation.

Jitter Reduction by Modulator-Bias Control in Analog Fiber-Optic Links Employing a Mach-Zehnder Modulator Followed by an Erbium-Doped Fiber Amplifier (마하-젠더 광 변조기와 EDFA로 구성된 아날로그 광통신 링크에서 변조기 바이어스 조정을 이용한 랜덤 지터의 감소)

  • Lee, Min-Young;Yoon, Young-Min;Shin, Jong-Dug
    • Journal of IKEEE
    • /
    • v.13 no.4
    • /
    • pp.103-109
    • /
    • 2009
  • We report an efficient jitter reduction technique in an analog fier-optic link employing a Mach-Zehnder modulator followed by an erbium-doped fiber amplifier. By adjusting the modulator-bias to $0.089V_{\pi}$, we could increase the RF gain up to 10.65 dB for 10 GHz RF signal and reduce the random jitter by 46.5%, max, at an input optical power of -0.11 dBm to the EDFA.

  • PDF

Cost Analysis of Monitoring System with Optic Fiber Sensors (광섬유센서를 이용한 모니터링 시스템의 비용 분석)

  • You, Young-Jun;Park, Ki-Tae;Joo, Bong-Chul;Lee, Chin-Hyung
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.4
    • /
    • pp.67-73
    • /
    • 2009
  • Civil infrastructure is the basis facility which builds up the base of national economy operation. Consequently unexpected sudden abnormal condition of civil infrastructure causes private and national property loss and moreover can spread social issue. Therefore, continuous maintenance and safety management for the civil infrastructures should be handled with great weight. Monitoring system for managing bridge maintenance was introduced first in the early of 1990s and has been developed up to real time measurement and analysis. Thesedays another system using fiber optic sensors is being developed. This paper presents the cost analysis of bridge monitoring system with fiber optic sensors which is gathering attention. Various cases were considered and the results were compared with that of monitoring system with electronic resistant type sensors widely used. As a results, fiber optic sensor system has good advantages in various cases, and a1so cost effectiveness compared to conventional sensor system.

  • PDF