DOI QR코드

DOI QR Code

Measurement and removal of a cerenkov light in a plastic optical fiber to detect a scintillating light

섬광검출을 위한 플라스틱광섬유에서의 체렌코프 빛 측정 및 제거

  • Cho, Dong-Hyun (School of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Biomedical & Health Science, Konkuk University) ;
  • Jang, Kyoung-Won (School of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Biomedical & Health Science, Konkuk University) ;
  • Yoo, Wook-Jae (School of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Biomedical & Health Science, Konkuk University) ;
  • Shin, Sang-Hun (School of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Biomedical & Health Science, Konkuk University) ;
  • Lee, Bong-So (School of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Biomedical & Health Science, Konkuk University) ;
  • Park, Byung-Gi (Department of Energy & Environmental Engineering, Soonchunhyang University) ;
  • Cho, Hyo-Sung (Department of Radiation Science, Institute of Health Science, Yonsei University) ;
  • Kim, Sin (Department of Nuclear & Energy Engineering, Applied Radiological Science Research Institute, Cheju National University)
  • 조동현 (건국대학교 의료생명대학 의학공학부, 의공학실용기술 연구소) ;
  • 장경원 (건국대학교 의료생명대학 의학공학부, 의공학실용기술 연구소) ;
  • 유욱재 (건국대학교 의료생명대학 의학공학부, 의공학실용기술 연구소) ;
  • 신상훈 (건국대학교 의료생명대학 의학공학부, 의공학실용기술 연구소) ;
  • 이봉수 (건국대학교 의료생명대학 의학공학부, 의공학실용기술 연구소) ;
  • 박병기 (순천향대학교 에너지환경공학과) ;
  • 조효성 (연세대학교 보건대학 방사선학과) ;
  • 김신 (제주대학교 에너지공학과)
  • Published : 2008.03.31

Abstract

The objectives of this study are to measure and to remove Cerenkov lights generated in a fiber-optic radiation sensor by a charge-coupled device. we have fabricated a fiber-optic radiation sensor which comprises an organic scintillator, a plastic optical fiber and a charge-coupled device. Charge-coupled device as a light measuring tool has many advantages which are easy in multi-dimensional measurements, high spatial resolution and relatively low cost.

Keywords

References

  1. B. Lee, W. Y. Choi, and J. K. Walker, 'Polymerpolymer miscibility study for plastic gradient index optical fiber', Polymer Eng. and Sci, vol. 40, no. 9, pp. 1996-1999, 2000 https://doi.org/10.1002/pen.11331
  2. A-M. Frelin, J-M. Fontbonne G. Ban, J. Colin, and M. Labalme, 'Spectral discrimination of Cerenkov radiation in scintillating dosimeters', Medical Physics, vol. 32, no. 9, pp. 3000-3006, 2005 https://doi.org/10.1118/1.2008487
  3. A. S. Bedder, T. R. Mackie, and F. H. Attix, 'Cerenkov light generated in optical fibers and other light pipes irradiated by electron beams', Phys. Med. Biol, vol. 37, pp. 925-935, 1992 https://doi.org/10.1088/0031-9155/37/4/007
  4. S. F. de Boer, A. S. Bedder, and J. A. Rawlison, 'Optical filtering and spectral measurements of radiation-induced light in plastic scintillation dosimetry', Phys. Med. Biol, vol. 33, pp. 945-958, 1993
  5. A. S. Beddar, 'Plastic scintillation dosimetry and its application to radiotherapy', Radiation Measurements, vol. 41, no. s124-s133, 2007 https://doi.org/10.1016/j.radmeas.2007.01.002
  6. A. M. Chugg, R. Jones, P. jones, and P. Nieeminen, 'A CCD miniature radiation monitor', Nuclear sci., vol. 49, no. 3, pp. 1327-1332, 2002 https://doi.org/10.1109/TNS.2002.1039662
  7. 신귀순, 방사선물리학, 신광출판사, pp.195-197, 2005
  8. Knoll, G. F. Knoll, Radiation detection and measurement - 3rd ed., John Wiley & Sons, New York, pp. 711-713, 1999
  9. B. S. Lee, D. H. Cho, K.W. Jang, S-C Chung, J-W Lee, S. Kim, and H. S. Cho, 'Measurements and characterization of cerenkov light in fiber-optic radiation sensor irradiated by high-energy electron beam', Japanese J. Applied Physics, vol. 45, No. 10A, pp. 7980-7982, 2006 https://doi.org/10.1143/JJAP.45.7980
  10. 장경원, 조동현, 정순철, 전재훈, 이봉수, 김신, 조효 성, 박성용, 신동호, '고에너지 전자선 측정을 위한 광섬유 방사선 센서에서의 체렌코프 빛 측정 및 분 석', 센서학회지, 제15권, 제3호, pp. 186-191, 2006 https://doi.org/10.5369/JSST.2006.15.3.186
  11. 장경원, 이봉수, 조동현, 김형식, 이정한, 이정환, 김 신, 조효성, '광학 필터를 이용한 광섬유 방사선 센 서의 체렌코프 빛 제거', 한국광학회지, 제17권, 제 4호, pp. 312-315, 2006 https://doi.org/10.3807/KJOP.2006.17.4.312
  12. 장경원, 조동현, 유욱재, 이봉수, 이정한, 탁계래, 조 효성, 김신, '치료용 고에너지 전자선 계측을 위한 광섬유 방사선 센서의 제작 및 특성 분석', J. Biomed. Eng. Res., vol. 27, no. 6, pp. 332-336, 2006