• 제목/요약/키워드: a drop test

검색결과 1,102건 처리시간 0.03초

밴드형 첨족예방기구의 효과와 유용성 (The Effects of the Band Type Foot Drop Device)

  • 강현숙;김원옥;이혜숙
    • 기본간호학회지
    • /
    • 제7권3호
    • /
    • pp.391-400
    • /
    • 2000
  • A long-term bed rest results in an inevitable foot drop. Yet preventive device such as a foot board and high-neck tennis shoes, are not widely used. This study was conducted to compare the effects of a pillow-type foot board with that of the band-type device. The band-type device of a resonable price is designed for an effective prevention of foot drop, and the convenience for it use. Among the non-equivalent control group design, foot drop preventive effects, usefulness of the device, as well as its cost effectiveness were examined. The study was carried out for four months from December 1999, and its subject had been patients and nurses of two intensive care units at K medical center in Seoul. According to the study purpose, the data collected were analyzed by $x^2-test$ and t-test. The results are as follow : 1. The ROM of ankle joint is promoted in the experimental group with a band-type device comparing the control group with a pillow type one. Dorsiflexion is particularly increased in the experimental group as compared with the control group, while planterflexion hardly shows any change. 2. The usefulness score of the experimental group nurses using the band-type device (23.97) is higher than that of the control group nurses (18.88). 3. In an aspect of the unit production cost, band-type devices are low-priced compare with pillow-type or other foot board (wooden) or high-neck tennis shoes. In summary, the newly developed band-type device is both useful and preventive for a foot drop. It is also desirable regarding to the production cost and the cost effectiveness. This fact proves that the new anti-foot drop device could be practical both for clinical care and home care. Yet the results were obtained by some subjects, it should be used after a further examination. More effective nursing intervention could be observed throughout general studies, including proper positioning and foot and ankle exercises which are the important variables of the foot drop prevention.

  • PDF

4.3 mm 세관내 R-22와 R-407C의 증발 열전달과 압력강하 (Evaporation Heat Transfer and Pressure Drop of Mixture Refrigerant R-22 and R-407C in a Diameter of 4.3 mm)

  • 노건상;손창효
    • 동력기계공학회지
    • /
    • 제12권4호
    • /
    • pp.26-31
    • /
    • 2008
  • The evaporation heat transfer coefficient and pressure drop of R-22 and R-407C in a small diameter copper tube were investigated experimentally. The main components of the refrigerant loop are a receiver, a compressor, a mass flow mete, a condense and a double pipe type evaporate (test section). The test section consists of a smooth copper tube of 4.3 mm inner diameter. The refrigerant mass fluxes were varied from 100 to $300[kg/m^{2}s]$ and the saturation temperature of evaporator were $5[^{\circ}C]$. The evaporation heat transfer coefficients of R-22 and R-407C increase with the Increase in mass flux and vapor quality. The evaporation heat transfer coefficient of R-22 is about $7.3\sim47.1%$ higher than that of R-407C. The evaporation pressure drop of R-22 and R-407C increase with the increase of mass flux. The pressure drop of R-22 is about $8\sim20%$ higher than that of R-407C.

  • PDF

아이오와 주 교통국의 FWD 네트워크 레벨 조사 프로토콜을 위한 최소 하중 재하 수와 조사지점 수의 결정 (Investigation of Minimum Number of Drop Levels and Test Points for FWD Network-Level Testing Protocol in Iowa Department of Transportation)

  • 김용주;이호신
    • 한국도로학회논문집
    • /
    • 제12권4호
    • /
    • pp.39-46
    • /
    • 2010
  • 2007년부터 아이오와 주 교통국에서는 고속도로와 국도에서 FWD 장비를 이용하여 네트워크 레벨에 필요한 조사를 실시하였고 처짐 자료와 포장 구조분석 결과를 데이터베이스로 구축하는 작업을 시작하였다. 축적된 데이터베이스에 정보는 포장에 구조적 문제점을 발견하고 포장에 잔류 공용수명을 예측하여 포장에 유지보수 시점을 결정하는데 사용한다. 현재 아이오와 주 교통국에서 사용하고 있는 FWD 네트워크 레벨 조사 프로토콜은 포장 표면에 3번에 하중을 각각 재하하여 8개에 지오폰으로부터 측정한 처짐량을 이용, 역 계산을 통해 포장구조 해석을 수행하고 있으며 조사지점 수는 조사하는 도로의 구간 길이에 따라 결정하고 있다. 그러나, 현재 사용하고 있은 FWD 네트워크 레벨 조사 프로토콜은 1년 동안 아이오와 주 전체 도로 네트워크에 약 20%만을 조사할 수 있는 것으로 나타났다. 따라서, 해마다 아이오와 주 도로 네트워크에 20% 이상을 조사하기 위해서는 현재 사용하고 있는 FWD 네트워크 레벨 조사 프로토콜을 간소화해야 할 필요가 있다. 본 연구에 목적은 현재 사용하고 있는 FWD 네트워크 레벨 조사 프로토콜에서 FWD 측정 데이터에 영향을 미치지 않는 범위내에서 최소 하중 재하 수와 조사지점 수를 결정하기 위한 것이다. 83개에 합성포장 구간을 대상으로 측정한 FWD 네트워크 레벨 조사에서는 FWD 네트워크 레벨 조사 프로토콜에서 하중 재하 수와 조사지점 수를 줄여도 포장 구조해석 결과에는 크게 영향을 미치지 않는 것으로 나타났다. 간소화된 FWD 네트워크 레벨 조사 프로토콜은 FWD 측정 결과에 영향을 미치지 않으면서 측정 조사율을 높일 수 있을 뿐만 아니라 교통 통제로 인한 간접비용도 절감시킬 수 있을 것으로 기대하고 있다.

자동차용 열교환기 냉매의 압력 강하 특성에 관한 연구 (A Study on Pressure Drop Characteristics of Refrigerant in Heat Exchanger for Automobile)

  • 임태우;박종운
    • 한국자동차공학회논문집
    • /
    • 제11권2호
    • /
    • pp.119-125
    • /
    • 2003
  • An experiment study on pressure drop was carried out for both an adiabatic and a diabatic two-phase flow with pure refrigerants R134a and Rl23 and their mixtures as test fluids in a uniformly heated horizontal tube. The frictional pressure drop during flow boiling is predicted by using two models; the homogeneous model that assumes equal phase velocity and the separate flow model that allows a slip velocity between two phases. The measured frictional pressure drop was compared to a few available correlations. Homogeneous model considerally underpredicted the present data for mixture as well as pure component in the entire mass velocity ranges employed in the present study, while Friedel correlation was found to satisfactorily correlate the frictional pressure drop data as compared to other correlation.

Smart Phone Display 낙하 Simulation과 설계 (Smart Phone Display Drop Simulation and Design)

  • 김원종
    • 한국산업융합학회 논문집
    • /
    • 제22권3호
    • /
    • pp.381-385
    • /
    • 2019
  • In this Study, as the structure of smart phone display becomes thin to catch up with slim product trend, the reliability of display module is on the rise as a issue for product design. Especially, almost part of cellular phone should undergo drop test when they fall 1.5m above ground. Thus many manufacturers have considered design guide line using CAE and simulation for more efficive usage of limited resources om the martket. This test simulates the case when cellular phone slips through user's flingers while he is talking on the phone. This paper studies a drop simulation of glass for display in smart phone. This design for reliability improvements are suggested on the basis of the results of FE Analysis and display of smart phone design.

군수품 환경시험을 위한 남한 산악 지역 고도에 따른 온도강하율 산출 연구 (A study on the temperature drop rate for a military product test & evaluation in the mountains)

  • 김영래;윤재형;나재현;김장은;김시옥;김동길;홍연웅
    • Journal of the Korean Data and Information Science Society
    • /
    • 제28권5호
    • /
    • pp.1145-1152
    • /
    • 2017
  • 환경시험은 수명주기 동안 시험대상품이 겪을 수 있는 환경에 노출되었을 때 고장 또는 비정상 작동 없이 정상 기능을 수행하는지를 확인하는 과정이다. 일반적으로 민수품에 비해 군수품은 산악 지형 등 극한 환경에 노출되는 경우가 상대적으로 많다. 고도가 높아질수록 기온은 낮아지게 되므로 저고도 지역에서 사용하는 군수품과는 다른 환경시험 기준이 필요하다. 따라서 산악지형에서 사용하는 군수품의 환경시험을 위해서는 온도강하율에 대한 고려 등 별도의 테일러링 절차가 필요하다. 국제표준기구에서 고도에 따른 온도강하율을 $-6.5^{\circ}C/1000m$라고 발표하였으나, 국내의 고도에 따른 온도강하율 기준은 없다. 본 논문에서는 남한 산악 지역의 고도에 따른 온도강하율을 제시한다. 이를 통해, 산악 지역에서 사용하는 군수품의 저온시험 기준값을 테일러링 할 수 있는 수식을 도출한다.

냉장고 낙하시 하힌지 동적변형 해석 (Finite Element Analysis of Dynamic Deformation of Refrigerator's Lower Hinge during Drop Test)

  • 홍석무;최용찬;엄성욱;김홍래;현홍철
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제3권1호
    • /
    • pp.37-44
    • /
    • 2015
  • 본 연구에서는 유한요소해석으로 냉장고 낙하충격에 대한 하힌지의 변형거동을 분석했다. 우선 하힌지 및 하부포장재 동적물성 확보를 위해 각각 속도 별 굽힘시험과 압축시험을 수행했다. 이어 시험에서 얻은 하중-변위곡선과 유사한 거동을 나타내는 하힌지 및 하부 포장재의 유동응력식을 역공학으로 얻었다. 확보한 물성데이터를 이용해 LS-DYNA로 낙하해석을 수행해, 낙하시 냉장고 자체 및 하힌지 변형거동을 분석했다. 최종적으로 3D 측정으로 분석한 실 냉장고 낙하시험으로, 낙하해석 모델의 유효성을 검증했다. 본 연구에서 제시한 해석모델은 추후 하힌지 및 포장재의 내 충격설계 등에 효과적으로 활용될 수 있을 것이다.

여자 농구 선수들의 착지 유형이 전방십자인대 손상위험 요인에 미치는 영향 (Effects of Landing Tasks on the Anterior Cruciate Ligament Injury Risk Factors in Female Basketball Players)

  • 이계산;임비오
    • 한국운동역학회지
    • /
    • 제24권4호
    • /
    • pp.385-390
    • /
    • 2014
  • The purpose of this study was to investigate the effects of landing tasks on the anterior cruciate ligament (ACL) injury risk factors in female basketball players. Fifteen female basketball players performed a drop landing and a drop landing with a vertical jump on the 40 cm height box. Three-dimensional motion analysis system and ground reaction force system was used for calculate the ACL injury risk factors. Paired samples t-test with Bonfferoni correction were performed. The drop landing with a vertical jump had the higher knee flexion angle, peak knee varus moment, trunk flexion angle than a drop landing. However, the drop landing had the higher trunk rotation angle than a drop landing with a vertical jump. These results indicate that seemingly minor variations between drop landing and drop landing with a vertical jump may influence the ACL injury risk factors. Caution should be used when comparing studies using different landing tasks.

CANDU 사용후핵연료 저장바스켓 설계 개선안 도출 (Design Enhancement of CANDU S/F Storage Basket)

  • 최우석;서기석;박완규
    • 방사성폐기물학회지
    • /
    • 제10권2호
    • /
    • pp.105-115
    • /
    • 2012
  • 월성원자력본부의 조밀건식저장시설인 MACSTOR/KN-400의 인허가 과정에서 사고조건에 대한 바스켓의 안전성 평가를 위한 실증시험의 필요성이 제기되었다. 실증시험을 위한 낙하시험시설을 한국원자력연구원에 설치하고 바스켓 낙하 실증시험을 수행하였다. 실증시험 결과 실린더 내 적재 바스켓의 상부 용접부가 낙하 바스켓과 충돌하여 파손되고 누설이 발생하였다. 기존 바스켓이 실증시험에서 누설율 성능요건을 만족하지 못함에 따라 바스켓의 설계 개선안 도출이 필요하게 되었다. 설계 개선을 위한 방향을 선정하고 이에 기초하여 6 종류의 설계 개선안을 도출하였다. 개별 설계 개선안에 대하여 구조해석 및 시편시험을 수행하였다. 구조해석 및 시편시험의 결과를 바탕으로 최종설계안을 확정하였다. 최종설계안은 바스켓의 중앙 포스트의 높이를 감소하여 낙하 바스켓과의 충돌속도를 감소시키는 설계안이었다. 최종설계안에 대한 시험모델을 제작하여 낙하실증시험을 재수행한 결과 모든 성능요건을 만족하였다.