• Title/Summary/Keyword: a TFT-LCD

Search Result 562, Processing Time 0.024 seconds

Technology to Fabricate PMMA Light Guiding Plate with nano pattern Using Nano Imprinting Technology (나노 임프린팅 기술에 의한 나노패턴을 갖는 PMMA 도광판 제조 기술)

  • Lee, B.W.;Lee, T.S.;Lee, C.H.;Lee, K.W.;Hong, C.;Chung, Jae-Hoon;Kim, C.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.414-415
    • /
    • 2007
  • PMMA light guiding plate with nano pattern was fabricated by nano imprinting technology. Silicon mold was fabricated by conventional photolithography. A nickel stamper was fabricated by electroplating process using silicon mold. Nano imprinting was performed on PMMA plate at $140^{\circ}C$ under pressure of 20kN. The nano pattern on PMMA plate was investigated using FE-SEM.

  • PDF

A 12b 130MS/s 108mW $1.8mm^2$ 0.18um CMOS ADC for High-Quality Video Systems (고화질 영상 시스템 응용을 위한 12비트 130MS/s 108mW $1.8mm^2$ 0.18um CMOS A/D 변환기)

  • Han, Jae-Yeol;Kim, Young-Ju;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.3
    • /
    • pp.77-85
    • /
    • 2008
  • This work proposes a 12b 130MS/s 108mW $1.8mm^2$ 0.18um CMOS ADC for high-quality video systems such as TFT-LCD displays and digital TVs requiring simultaneously high resolution, low power, and small size at high speed. The proposed ADC optimizes power consumption and chip area at the target resolution and sampling rate based on a three-step pipeline architecture. The input SHA with gate-bootstrapped sampling switches and a properly controlled trans-conductance ratio of two amplifier stages achieves a high gain and phase margin for 12b input accuracy at the Nyquist frequency. A signal-insensitive 3D-fully symmetric layout reduces a capacitor and device mismatch of two MDACs. The proposed supply- and temperature- insensitive current and voltage references are implemented on chip with a small number of transistors. The prototype ADC in a 0.18um 1P6M CMOS technology demonstrates a measured DNL and INL within 0.69LSB and 2.12LSB, respectively. The ADC shows a maximum SNDR of 53dB and 51dB and a maximum SFDR of 68dB and 66dB at 120MS/s and 130MS/s, respectively. The ADC with an active die area of $1.8mm^2$ consumes 108mW at 130MS/s and 1.8V.

Perceptual Quality Assessment on Display based on Analytic Network Process (Analytic Network Process 기반의 디스플레이 인지화질 평가)

  • Sung, Jung-Min;Choi, Bong-Seok;Choi, Bong-Yeol;Ha, Yeong-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.7
    • /
    • pp.180-189
    • /
    • 2014
  • Display quality assessment has been a long standing issue due to the diversity of display devices and the rapid growth of display technology. The conventional display quality assessment methods are mostly those methods which evaluate qualities of a display by measuring physical quantities, but the results from the methods are not equal to the perceived results which are acquired with subjective experiments. Thus, we need to solve the above contrariety as well as establish the quantitative correlation between physical and perceived results. This paper proposes the systematic method of evaluating relative perceived qualities among various display devices and quantifies these relative perceived qualities. The proposed method is based on Analytic Network Process(ANP), which is one of the most popular decision making methods in the business administration field. We also adopted three evaluation criteria, which consist of color, shape and depth, in order to reflect the human visual system and chose eight sub-criteria related to display characteristics via question investigation. We carried out a subjective experiment and the proposed method which evaluated perceived qualities of two display devices(TFT-LCD, OLED) in order to prove the similarity between their results. As a result, it is proved that the order relationship between perceived qualities was the same as the order of results got through the subjective experiment.

Characteristic of Cu-Ag Added Thin Film on Molybdenum Substrate for an Advanced Metallization Process (TFT-LCDs에 적용 가능한 Cu-Ag 박막에 대한 Mo 기판 위에서의 특성조사)

  • Lee, H.M.;Lee, J.G.
    • Korean Journal of Materials Research
    • /
    • v.16 no.4
    • /
    • pp.257-263
    • /
    • 2006
  • We have investigated the effect of silver added to Cu films on the microstructure evolution, resistivity, surface morphology, stress relaxation temperature, and adhesion properties of Cu(Ag) alloy thin films deposited on Mo glue layer upon annealing. In addition, pure Cu films deposited on Mo has been annealed and compared. The results show that the silver in Cu(Ag) thin films control the grain growth through the coarsening of its precipitates upon annealing at $300^{\circ}C{\sim}600^{\circ}C$ and the grain growth of Cu reveals the activation energy of 0.22 eV, approximately one third of activation energy for diffusion of Ag dopant along the grain boundaries in Cu matrix (0.75 eV). This indicates that the grain growth can be controlled by Ag diffusion along the grain boundaries. In addition, the grain growth can be a major contributor to the decreased resistivity of Cu(Ag) alloy thin films at the temperature of $300^{\circ}C{\sim}500^{\circ}C$, and decreases the resistivity of Cu(Ag) thin films to $1.96{\mu}{\Omega}-cm$ after annealing at $600^{\circ}C$. Furthermore, the addition of Ag increases the stress relaxation temperature of Cu(Ag) thin films, and thus leading to the enhanced resistance to the void formation, which starts at $300^{\circ}C$ in the pure Cu thin films. Moreover, Cu(Ag) thin films shows the increased adhesion properties, possibly resulting from the Ag segregating to the interface. Consequently, the Cu(Ag) thin films can be used as a metallization of advanced TFT-LCDs.

A Study of Intelligent Head Up Display System for Next Generation Vehicle (차세대 자동차를 위한 HUD 모니터 시스템에 관한 연구)

  • Yun, Sung-Ha;Son, Hui-Bae;Rhee, Young-Chul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.1
    • /
    • pp.23-31
    • /
    • 2011
  • In this paper, the intelligent smart monitor system is implemented for the next generation vehicle. to mitigate the numerous effects of distractions within the vehicle, it is vital to put critical information where the driver can use it without affection focus on the road ahead. Audible alarms are useful supplements when used in conjunction with visual displays. But driving is an overwhelmingly visual task. To optimize a vehicle's active safety systems, more than just audible alarms are necessary. The driver needs a visual interface that focuses his or her attention on the road ahead. The most commonly viewed information in a vehicle is from the instrument cluster, where speed, tachometer, fuel, engine temperature, fuel gauge, turn indicators and warning lights provide the driver with an array of fundamental information. TFT LCD, LCD Back light led, plane mirror, lens and controllers parts were designed to intelligent integrated smart monitor system. Finally, in this paper, we analyze intelligent integrated smart monitor system for driver safety vehicles.

Measurement of the Photon Fluence for the Evaluation of Photon Detection Efficiency of Photon Counting Sensor (광계수형 센서의 포톤계수효율 평가를 위한 포톤플루엔스 측정)

  • Park, Ji-Koon;Heo, Ye-Ji;Kim, Kyo-Tae;Noh, Si-Cheol;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Recently, the various digital X-ray imaging devices using CCD and TFT LCD-based flat panel digital X-ray sensor are being used. In particular, a number of studies on photon counting sensor technique have been reported. In this study, the incident X-rays fluence on the photon counting sensor material was measured to estimate photon detection efficiency which is the quantitative performance evaluation factor of photon counting sensor. The result of measuring the photon fluence by using RQA-M2 Radiation beam quality of IEC 61223-1-2 recommendations, the incident photon fluence could be defined as about $4 photons/(0.01mm)^2{\cdot}{\mu}Gy$ within $10{\mu}m$ pin-hole area, and about $50photons/(0.03mm)^2{\cdot}{\mu}Gy$ within $30{\mu}m$ pin-hole area, and about $698photons/(0.1mm)^2{\cdot}{\mu}Gy$ within $100{\mu}m$ pin-hole area. Consequently, with the previously setup of the incident fluence, the measuring of actual photon counting efficiency by observing the output waveform of the photon counting sensor material was considered possible.

A Study on the Retina shaped Optical Path Shift Using the Prism

  • Kwon Yun Jung;Nam Sang Yep;Lee Sung Chang
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.699-702
    • /
    • 2004
  • This paper discusses about the mechanism of catching an image through an optical manipulation of each organizations in the eye, more specifically, mechanism of catching an image on a retina through a Camera and a Crystal Lens. In the retina, the macula roles as a fovea contrails and it leads the image which is about 3 mm to be shaped on there. However, even the macula may not properly function, our eyes still can catch the image by shifting the optical path to around of the macula, even if the sensitivity of the image is generally lower than the image on the macula. This paper proposes a method of shifting the shaped image on the retina by refracting the optical path through a prism located on the rear of a screen which consists of a 0.7' TFT LCD. Applying this method that throwing an image around on the macula, central visual disturbance patients among retinitis pimentos patients can expect to recover such a mechanism to catch an image.

  • PDF

A Study on the Visualization of Suzi Mora Defect of FPD Color Filter (FPD용 컬러 필터의 수지 얼룩 결함 형상화에 관한 연구)

  • Kwon, Oh-Min;Lee, Jung-Seob;Park, Duck-Chun;Joo, Hyo-Nam;Kim, Joon-Seek
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.8
    • /
    • pp.761-771
    • /
    • 2009
  • Detecting defects on FPD (Flat Panel Display) color filter before the full panel is made is important to reduce the manufacturing cost. Among many types of defects, the low contrast blemish such as Suzi Mura is difficult to detect using standard CCD cameras. Even skilled inspectors in the inspection line can hardly identify such defects using bare eyes. To overcome this difficulty, point spectrometer has been used to analyze the spectrum to differentiate such defects from normal color filters. However, scanning ever increasing-size color filters by a point spectrometer takes too long time to be used in real production line. We propose a system using a spectral camera which can be viewed as a line scan camera composed of an array of point spectrometers. Three types of lighting system that exhibit different illumination spectrums are devised together with a calibration method of the proposed spectral camera system. To visualize the defect areas, various processing algorithms to identify and to enhance the small differences in spectrum between defective and normal areas are developed. Experiments shows 85% successful visualization. of real samples using the proposed system.

A Study on Adaptive Design of Mechanical Part for Smooth Lift (유연 승강기용 부품의 적용 설계에 관한 연구)

  • 최성대;정선환;조규열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1454-1457
    • /
    • 2003
  • This study was carried out to minimize the lifting force of a two hinge type stand mechanism. This unit is designed for the display devices in order to enhance the ergonomics for effective height adjustment and maintenance at any preferred position. The unit will be very useful for the mechanism fabricated with a coil spring and disc springs as a torque generator. The maximum and the minimum torque value should be calculated initially for the smooth lift. And the reasonable torque distribution is necessary to prevent any AUTO LIFT and AUTO Drooping at any position because the torque generated by coil spring is more sensitive than disc spring in tilting the position. Therefore, the analysis of the coil spring is requisite to issue the specific torque value depending on the distorted angle with securing reliability of a long time storage condition. After the theoretical torque value was calculated, the evaluation was carried out by making a proto-type sample, then distorted angle was updated by experiment. The result of this study can readily be applied to various units for the optimization of the smooth lift.

  • PDF

Design of a Robust Position Tracking Controller with Sliding Mode for a 6-DOF Micropositioning Stage (6자유도 정밀 스테이지의 추종제어를 위한 슬라이딩 모드 제어기 설계)

  • Moon, Jun-Hee;Lee, Bong-Gu
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.2
    • /
    • pp.121-128
    • /
    • 2011
  • As high precision industries such as semiconductor, TFT-LCD manufacturing and MEMS continue to grow, the demand for higher DOF precision stages has been increasing. In general, the stages should accommodate a prescribed range of payloads in order to position various precision manufacturing/inspection instruments. Therefore a nonlinear controller using sliding motion is developed, which bears mass perturbation and makes the upper plate of the stage move in 6 DOF. For the application of the nonlinear control, an observer is also developed based on expected noise covariance. To eliminate the steady state error of step response, integral terms are inserted into the state-space model. The linear term of the controller is designed using optimization scheme in which parameters can be weighted according to their physical significance, whereas the nonlinear term of the controller is designed using trial and error method. A comprehensive simulation study proves that the designed controller is robust against mass perturbation and completely eliminates steady state errors.