• Title/Summary/Keyword: a SPR

Search Result 238, Processing Time 0.02 seconds

Direct Triazine Herbicide Detection Using a Self-Assembled Photosynthetic Reaction Center from Purple Bacterium

  • Nakamura, Chikashi;Hasegawa, Miki;Shimada, Kazumi;Shirai, Makoto;Miyake, Jun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.6
    • /
    • pp.413-417
    • /
    • 2000
  • In this study, a direct detection system for triazine derivative herbicides was developed using the photosynthetic reaction center (RC) from the purple bacterium, Rhodobacter sphaeroides, and surface plasmon resonance (SPR) apparatus. The histidine-tagged RCs were immobilized on an SPR gold chip using nickel-nitrilotriacetic acid groups as a binder for one of the triazine herbicide, atrazine. The SPR responses were proportional to the sample concentrations of atrazine in the range 0.1-1 $\mu\textrm{g}$/mL. The sensitivity of the direct detection of atrazine using the RC-assembled sensor chip was higher than that using the antibody-immobilized chip. The other types of herbicides, DCMU or MCPP, were not detected with such high sensitivity. The results indicated the high binding selectivity of the RC complex.

  • PDF

The Integrated Surface Plasmon Resonance Sensor using Polymer Optical Waveguide (폴리머 광도파로를 이용한 집적형 표면 플라즈몬 공명 센서)

  • Oh, Geum-Yoon;Kim, Doo-Gun;Kim, Hong-Seung;Lee, Tae-Kyeong;Choi, Young-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.433-436
    • /
    • 2012
  • We propose a novel micro surface plasmon resonance (SPR) sensor system based on polymer materials. The proposed SPR system consists of the incident medium with polymer waveguide and the gold thin film for sensing area. Using a polymer optical waveguide instead of a prism in SPR sensing system offers miniaturization, low cost, and potable sensing capability. The whole device performance was analyzed using the finite-difference time domain method. The optimum gold thickness in the attenuated total reflection mirror of polymer waveguide is around 50 nm and the resonance angle to generate surface plasmon wave is 68 degrees.

An Experimental Method for the Scatter Correction of MV Images Using Scatter to Primary Ratios (SPRs) (산란선 대 일차선비(SPR)를 이용한 MV 영상의 산란 보정을 위한 실험적 방법)

  • Jeon, Hosang;Park, Dahl;Lee, Jayeong;Nam, Jiho;Kim, Wontaek;Ki, Yongkan;Kim, Donghyun;Lee, Ju Hye;Kim, Dongwon
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.143-150
    • /
    • 2014
  • In general radiotherapy, mega-voltage (MV) x-ray images are widely used as the unique method to verify radio-therapeutic fields. But, the image quality of MV images is much lower than that of kilo-voltage x-ray images due to scatter interactions. Since 1990s, studies for the scatter correction have performed with digital-based MV imaging systems. In this study, a novel method for the scatter correction is suggested using scatter to primary ratio (SPR), instead of conventional methods such as digital image processing or scatter kernel calculations. We measured two MV images with and without a solid water phantom describing a patient body with given imaging conditions, and calculated un-attenuated ratios. Then, we obtained SPR distributions for the scatter correction. For experimental validation, a line-pair (LP) phantom using several Al bars and a clinical pelvis MV image was used. As the result, scatter signals of the LP phantom image were successfully reduced so that original density distribution of the phantom was restored. Moreover, image contrast values increased after SPR correction at all ROIs of the clinical image. The mean value of increases was 48%. The SPR correction method suggested in this study has high reliability because it is based on actually measured data. Also, this method can be easily adopted in clinics without additional cost. We expected that the SPR correction can be an effective method to improve the quality of MV image guided radiotherapy.

The Construction of the SPR (Surface Plasmon Resonance) Sucrose Sensor (표면 플라즈몬 공명형 자당 센서의 제작)

  • Um, N.S.;Lee, S.M.;Hahm, S.H.;Koh, K.N.;Lee, S.H.;Kang, S.W.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.279-284
    • /
    • 1998
  • A surface plasmon resonance (SPR) sensor system for the determination of sucrose concentration was constructed with a gold thin film sensing chip. The properties of gold thin film are critical factors in exciting surface plasmon resonance phenomena. Therefore in the present paper, the fabrication conditions of gold thin film were investigated to optimize the SPR phenomena. The optimum thickness was obtained as $545{\AA}$ with $43.75^{\circ}$ resonance angle and good surface roughness limitation. about $3{\AA}$. The linear resonance angle shifts and rapid response were observed from the sucrose concentrations ranged from 0 to 40wt%.

  • PDF

Work-flow Analysis and Specification Definition Method of Software Process (소프트웨어 프로세서의 작업흐름 분석과 명세정의 방법)

  • Yang, Hae-Sool
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.4
    • /
    • pp.904-914
    • /
    • 1998
  • BPR(Business Process Reengineering), a radical improvement approach of business process, has been paying attention, and work-flow management and automation has been concentrated on progress velocity of business process and productivity of engineers. In software engineering, software process engineering which focus to process begin to be watched, and for the purpose of software productivity and quality progress and reduction of development term, study on SPR(Software Process Reengineering) is being progressed. In this paper, made workflow analysis and design method for construction of work-flow management system of software process to stand firm process reengineering methodology. In other words, we studied modeling process methods for SPR process, and software process structure and workflow analysis method which construct software process workflow model and specification definition method of workflow software.

  • PDF

Development of Image-based Assistant Algorithm for Vehicle Positioning by Detecting Road Facilities

  • Jung, Jinwoo;Kwon, Jay Hyoun;Lee, Yong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.5
    • /
    • pp.339-348
    • /
    • 2017
  • Due to recent improvements in computer processing speed and image processing technology, researches are being actively carried out to combine information from a camera with existing GNSS (Global Navigation Satellite System) and dead reckoning. In this study, the mathematical model based on SPR (Single Photo Resection) is derived for image-based assistant algorithm for vehicle positioning. Simulation test is performed to analyze factors affecting SPR. In addition, GNSS/on-board vehicle sensor/image based positioning algorithm is developed by combining image-based positioning algorithm with existing positioning algorithm. The performance of the integrated algorithm is evaluated by the actual driving test and landmark's position data, which is required to perform SPR, based on simulation. The precision of the horizontal position error is 1.79m in the case of the existing positioning algorithm, and that of the integrated positioning algorithm is 0.12m at the points where SPR is performed. In future research, it is necessary to develop an optimized algorithm based on the actual landmark's position data.

Detection of IgG Using Thiolated Protein G Modified SPR Sensor Chip (Thiolated protein G로 개질된 SPR 센서 칩을 이용한 IgG 검출)

  • Sin, Eun-Jung;Lee, Yeon-Kyung;Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.434-438
    • /
    • 2011
  • A portable surface plasmon resonance(SPR) based immunosensor using thiolated protein G and protein G was developed for the detection of immunoglobulin G(IgG). The protein G has specific affinity with Fc fragment of IgG and was thiolated by 2-Iminothiolane for introduction of thiol groups. Anti-IgG, bovine serum albumin(BSA), and IgG have been sequently injected after surface modification of gold sensor chip with protein G and thiolated protein G. The output signal was increased with the injection of each protein and the actual signal was measured by subtracting signal of reference channel from signal of sample injected channel. The experimental results showed the higher detection capability of IgG using thiolated protein G compared with protein G. From these results, we can conclude that the current surface modification technique and the portable SPR sensor system can be applied to various immunosensors for diagnosis.

A Study on the Sensitivity of Surface Plasmon Resonance Sensor Chips with Various Material Configurations in Angle and Intensity Detection Modes (공명각 및 반사광 측정 모드에서 다양한 물질 구성의 표면 플라즈몬 공명 센서 칩의 민감도 특성)

  • Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.402-407
    • /
    • 2017
  • Characteristics of various material surface plasmon resonance (SPR) chips were investigated in angular interrogation mode and intensity interrogation mode. Among five metals, silver (Ag), gold (Au), copper (Cu), chromium (Cr) and titanium (Ti), three metals, Ag, Au and Cu were paid attention to since their characteristics can be easily analyzed in angular interrogation mode by investigating the change of their reflectance curves according to refractive index change from 1.331 to 1.335. Most of SPR chips with various configurations showed the similar property in angular interrogation mode. The application of the SPR chip made of Ag, Au and Cu or their combinations depends on their reflectance properties. In intensity interrogation mode, the operation range may be limited since the variation of the intensity was not linearly related to refractive index change ranging from 1.331 to 1.335. However, the SPR chip containing high ratio of Ag may be applicable to high sensitive detection due to their sharp reflectance curves in intensity interrogation mode.

A Study for Automatic Train Speed Regulation Algorithm of ATO (ATO 장치의 자동 열차속도 조절 알고리즘에 관한 연구)

  • 김중환;강리택
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.210-218
    • /
    • 1998
  • The ATO(Automatic Train Operation) System is used for train operation instead of drivers. It is interfaced with TCMS(Train Control and Monitoring System) and ATC/TWC system in the train and wayside facilities. In this paper describes configuration of ATO, specification of ATO hardware, construction of ATO software and the algorithm fur automatic train speed regulation in the carborn ATO system. ATO Application Software is consist of ART, SPR, REG, SRV and PSM tasks. ART task is main control part of the ATO that determine ATO control, ATO mode, state transition. SPR determine speed reference according to train motion status, track data, train data and restricted train speed. REG task regulated train speed form the starting of one station to the precision stop at the other station under the result of ART and SPR tasks. In this paper, a algorithm for the train speed regulation while running is described.

  • PDF

Nano SPR Biosensor for Detecting Lung Cancer-Specific Biomarker (폐암 바이오마커 검출용 나노SPR 바이오센서)

  • Jang, Eun-Yoon;Yeom, Se-Hyuk;Eum, Nyeon-Sik;Han, Jung-Hyun;Kim, Hyung-Kyung;Shin, Yong-Beom;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.144-149
    • /
    • 2013
  • In this research, we developed a biosensor to detect lung cancer-specific biomarker using Anodic Aluminum Oxide (AAO) chip based on interference and nano surface plasmon resonance (nanoSPR). The nano-porous AAO chip was fabricated $2{\mu}m$ of pore-depth by two-step anodizing method for surface uniformity. NanoSPR has sensitivity to the refractive index (RI) of the surrounding medium and also provides simple and label-free detection when specific antibodies are immobilized to the Au-deposited surface of nano-porous AAO chip. To detect the lung cancer-specific biomarker, antibodies were immobilized on the surface of the chip by Self Assembled Monolayer (SAM) method. Since then lung cancer-specific biomarker was applied atop the antibodies immobilized layer. The specific reaction of the antigen-antibody contributed to the change in the refractive index that cause shift of resonance spectrum in the interference pattern. The Limit of Detection (LOD) was 1 fg/ml by using our nano-porous AAO biosensor chip.