• Title/Summary/Keyword: a 3D detector

Search Result 420, Processing Time 0.021 seconds

Validation and Determination of Glycyrrhizic Acid as a Marker Substance in Bu-Zhong-Yi-Qi-Tang by HPLC/DAD (HPLC/DAD에 의한 보중익기탕 중의 글리시리진산 정량분석법의 확립)

  • Baek, Ju-Hyun;Kim, Sun-Min;Ahn, Ji-Won;Cho, Chang-Hee;Oh, Mi-Hyune;Cho, Jung-Hee;Lee, Mi-Kyeong;Kim, Hyo-Jin
    • YAKHAK HOEJI
    • /
    • v.52 no.1
    • /
    • pp.7-11
    • /
    • 2008
  • A high performance liquid chromatographic (HPLC) method for the determination of glycyrrhizic acid was developed for the quality control of traditional herbal medicinal preparation Bu-Zhong-Yi-Qi-Tang (BZYQT), which is well-known herbal medicine used as tonic. RP-HPLC analysis was carried out using Capcell pak $C_{18}$ MG column $(5\;{\mu},\;150{\times}4.6\;mm)$ and a mobile phase consisting of acetonitrile and water containing 0.03% phosphoric acid (pH 2.46) at a flow rate of 1.0 ml/min. The optimum wavelength for the detection of the glycyrrhizic acid was found at 250 nm using diode-array UV/VIS detector. The glycyrrhizic acid in BZYQT shows good linearity $(r^2>0.999)$ in the range of $15\;{\mu}g/ml$ to 500 ${\mu}g/ml$. The limit of detection (LOD) was less than 5 ng and R.S.D for intra-day and inter-day reproducibility was less than 7%. The mean recovery of the glycyrrhizic acid was $97.3{\sim}113.0%$. These results suggest that the developed HPLC method is simple and efficient, and could be contributed for the quality control of commercial BZYQT products.

Quantitative Measurement of Soot concentration by Two-Wavelength Correction of Laser-Induced Incandescence Signals (2파장 보정 Laser-Induced Incandescence 법을 이용한 매연 농도 측정)

  • 정종수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.54-65
    • /
    • 1997
  • To quantify the LII signals from soot particle of flames in diesel engine cylinder, a new method has been proposed for correcting LII signal attenuated by soot particles between the measuring point and the detector. It has been verified by an experiment on a laminar jet ethylene-air diffusion flame. Being proportional to the attenuation, the ratio of LII signal at two different detection wavelengths can be used to correct the measured LIIsignal and obtain the unattenuated LII signal, from which the soot volume fraction in the flame can be estimated. Both the 1064-nm and frequency-doubled 532-nm beams from the Nd : YAG laser are used. Single-shot, one-dimensional(1-D) line images are recorded on the intensified CCD camera, with the rectangular-profile laser beam using 1-mm-diameter pinhole. Two broadband optical interference filters having the center wavelengths of 647 nm and 400 nm respectively and a bandwidth of 10 nm are used. This two-wavelength correction has been applied to the ethylene-air coannular laminar diffusion flame, previously studied on soot formation by the laser extinction method in this laboratory. The results by the LII measurement technique and the conventional laser extinction method at the height of 40 nm above the jet exit agreed well with each other except around outside of the peaks of soot concentration, where the soot concentration was relatively high and resulting attenuation of the LII signal was large. The radial profile shape of soot concentration was not changed a lot, but the absolute value of the soot volume fraction around outside edge changed from 4ppm to 6.5 ppm at r=2.8mm after correction. This means that the attenuation of LII signal was approximately 40% at this point, which is higher than the average attenuation rate of this flame, 10~15%.

  • PDF

A Rapid Method for Determination of ATP and Its Related Compounds in Dried Fish and Shellfish Products Using HPLC (HPLC에 의한 시판수산건제품의 ATP분해생성물의 신속정량법)

  • LEE Eung-Ho;KOO Jae-Geun;AHN Chang-Bum;CHA Yong-Jun;OH Kwang-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.5
    • /
    • pp.368-372
    • /
    • 1984
  • This paper deals with a rapid method for determination of ATP and its related compounds in fish and shellfish products using high performance liquid chromatography(HPLC). The HPLC used is a HPLC/ALC-224 equiped with UV-spectrophotometer (254 nm) as detector and integrator (Yanagimoto system-1000). The column used is a stainless steel tubing ($30.0\;cm{\times}3.9\;mm\;i.d.$) packed with ${\mu}-Bon-dapak\;C_{18}$. A mixture of $1\%$ triethylamine-phosphoric acid(pH6.5) was used as an eluent and the flow rate of the eluent was controlled at 2 ml/min. For the separation of ATP and its related compounds, a standard mixture of ATP, ADP, AMP, IMP, inosine and hypoxanthine was subjected to HPLC under the above mentioned conditions. Six peaks were obtained with retention times within 20 min, and elution order were hypoxanthine, IMP, inosine, AMP, ADP and ATP. But 5'-IMP and 5'-GMP fractions were not separated by this method. In generally, IMP content in boiled-dried fish and shellfish products purchased from the market was comparatively higher than that of other nucleotides. Especially, boiled-dried big eye herring marked higher value in IMP content than other boiled-dried ones. Hypoxanthine and inosine were major components of ATP-related compounds in dried products and seasoned-dried ones. And IMP content in seasoned-dried products was higher than that of dried ones. This fact is suggested that a part of IMP in seasoned-dried ones was derived from flavoring matter (MSG, 5'-IMP and 5'-GMP) which is added during the seasoning treatment.

  • PDF

A Study on the Optimum Amount of Contrast Media in Brain Angiography (뇌 혈관검사 시 적정 조영제량에 관한 연구)

  • Kim, Gyoo-Hyung;Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.123-128
    • /
    • 2018
  • Recently, the use of contrast agents has been increasing as a broader range of tests and dynamic tests have become common due to the development of equipment and imaging techniques such as Multi-Detector CT. However, the side effects of using contrast agents have been reduced by the development of non-ionic contrast agents, but they are still occurring often. The purpose of this study was to propose a method to minimize the side effect of contrast agent by using the amount of contrast agent injected to the brain angiography test to suppress excessive use of contrast agent and analyze the amount of contrast agent. Patients who were prescribed Brain Angiography due to cerebrovascular disease, According to the results of the comparison of the results obtained by dividing into 4 groups of 10ml each according to the amount of contrast medium injected with contrast agent according to the BMI of the patient, BA and SNR were not different between groups, and even if the amount of contrast injection was reduced, there was no problem in the evaluation of CT angiography through 3D reconstruction. This result shows that even if the contrast medium is injected into the blood vessels of the patient first and then the contrast medium is used as the physiological saline solution, the contrast medium is reduced by 40% it can be expected to minimize.

A Short Term Screening Method for Carcinogenic Quinone Compounds (Quinone계 화합물의 발암성 조기검색법에 관한 연구)

  • Cho, Dae-Hyun;Hong, Jin-Tae;Park, Jeong-Sik;Hong, Youn-Tack;Chin, Kang;Jung, Myung-Hee;Lee, Byung-Mu
    • Toxicological Research
    • /
    • v.8 no.2
    • /
    • pp.171-177
    • /
    • 1992
  • To investigate a short term screening method for carcinogenic quinone compounds, 8-hydroxydeoxyguanosine (8-OHdG), an oxidative DNA damage, was determined in the kidney and liver DNA isolated from Sprague-Dawley rats after i.p.injection of 7 mg/kg adriamycin (AM), 7mg/kg tetrahydropyranyladriamycin (THP), and 10mg/kg daunomycin (DM) by HPLC-electrochemical detector system. 8-OHdG was also determined from rat hepatocvtes and calf thymus DNA exposed to AM, DM and THP. When rats were treated with DM and THP, 8-OHdG was significantly increased in the kidney compared to control group, and remained at high level (7.9~9.0, 8-OHdG/dG${\times}10^4$)at the end of experiments (48hr after treatment). 8-OHdG level in cultured hepatocyte exposed to AM, DM and THP was 1.5~2 fold higher than control at all time points. (1,2,3,4hr after treatment). From calf thymus DNA exposed to AM, DM and THP, 8-OHdG was 2.5 fold higher than of control. These results suggest that quantitation of 8-OHdG may provide a useful marker for identifying target organ in oxidative chemical carcinogenesis and for short term screening of free radical generating carcinogens.

  • PDF

Assessment of radionuclides from coal-fired brick kilns on the outskirts of Dhaka city and the consequent hazards on human health and the environment

  • M.M. Mahfuz Siraz;M.D.A. Rakib;M.S. Alam;Jubair Al Mahmud;Md Bazlar Rashid;Mayeen Uddin Khandaker;Md. Shafiqul Islam;S. Yeasmin
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2802-2811
    • /
    • 2023
  • In a first-of-its-kind study, terrestrial radionuclide concentrations were measured in 35 topsoil samples from the outskirts of Dhaka using HPGe gamma-ray spectrometry to assess the radiological consequences of such a vast number of brick kilns on the plant workers, general as well as dwelling environment. The range of activity concentrations of 226Ra, 232Th, and 40K is found at 19 ± 3.04 to 38 ± 4.94, 39 ± 5.85 to 57 ± 7.41, and (430 ± 51.60 to 570 ± 68.40) Bq/kg, respectively. 232Th and 40K concentrations were higher than the global averages. Bottom ash deposition in lowlands, fly ash buildup in soils, and the fallout of micro-particles are all probable causes of the elevated radioactivity levels. 137Cs was found in the sample, which indicates the migration of 137Cs from nuclear accidents or nuclear fallout, or the contamination of feed coal. Although the effective dose received by the general public was below the recommended dose limit but, most estimates of hazard parameters surpass their respective population weighted global averages, indicating that brick kiln workers and nearby residents are not safe due to prolonged exposures to terrestrial radiation. In addition, the soil around sampling sites is found to be unsuitable for agricultural purposes.

A Study on the Safety of Alcohol-based Hand Sanitizers (알코올을 주성분으로 하는 손소독제의 안전성 연구)

  • Sun-Ok Jung;Chun-Yeong Lee;Hoe-Jin Ryu;Hee-Jin Choi;Ji-Young Kim;Chae-Man Choi;In-Sook Hwang;Yong-Seung Shin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.1
    • /
    • pp.34-39
    • /
    • 2023
  • Objectives: In this study, the safety of alcohol-based hand sanitizers (ABHSs) for quasi-drugs and cosmetics was investigated by analyzing the ethanol content, which is an active ingredient with a sterilizing effect, and methanol, which is toxic. Methods: Forty-one ABHSs were purchased at large supermarkets and online stores. Ethanol quantification was performed by gas chromatography-flame ionization detector, and methanol quantification was performed by headspace-gas chromatography-mass spectrometry. Results: The ethanol content of ABHS in quasi-drugs was 49.6-67.8%, which was suitable for standard manufacturing procedures for external disinfectants, and the ethanol content of ABHS in cosmetics was 9.1-61.3%. The methanol content of ABHS in quasi-drugs ranged from not detected(N.D.)-131.8 ppm, which was suitable for the methanol detection standard of ethanol raw materials in the Korean Pharmacopoeia. The methanol content of ABHS in cosmetics was 23.4-859.7 ppm, which was suitable for the detection limit of methanol in cosmetics. Conclusions: The ethanol and methanol content of ABHS was judged to be safe. When selecting an ABHS to be used for sterilization, it seems necessary to check the content of ethanol, an active ingredient, and use it according to its intended purpose.

Study of Feature Based Algorithm Performance Comparison for Image Matching between Virtual Texture Image and Real Image (가상 텍스쳐 영상과 실촬영 영상간 매칭을 위한 특징점 기반 알고리즘 성능 비교 연구)

  • Lee, Yoo Jin;Rhee, Sooahm
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1057-1068
    • /
    • 2022
  • This paper compares the combination performance of feature point-based matching algorithms as a study to confirm the matching possibility between image taken by a user and a virtual texture image with the goal of developing mobile-based real-time image positioning technology. The feature based matching algorithm includes process of extracting features, calculating descriptors, matching features from both images, and finally eliminating mismatched features. At this time, for matching algorithm combination, we combined the process of extracting features and the process of calculating descriptors in the same or different matching algorithm respectively. V-World 3D desktop was used for the virtual indoor texture image. Currently, V-World 3D desktop is reinforced with details such as vertical and horizontal protrusions and dents. In addition, levels with real image textures. Using this, we constructed dataset with virtual indoor texture data as a reference image, and real image shooting at the same location as a target image. After constructing dataset, matching success rate and matching processing time were measured, and based on this, matching algorithm combination was determined for matching real image with virtual image. In this study, based on the characteristics of each matching technique, the matching algorithm was combined and applied to the constructed dataset to confirm the applicability, and performance comparison was also performed when the rotation was additionally considered. As a result of study, it was confirmed that the combination of Scale Invariant Feature Transform (SIFT)'s feature and descriptor detection had the highest matching success rate, but matching processing time was longest. And in the case of Features from Accelerated Segment Test (FAST)'s feature detector and Oriented FAST and Rotated BRIEF (ORB)'s descriptor calculation, the matching success rate was similar to that of SIFT-SIFT combination, while matching processing time was short. Furthermore, in case of FAST-ORB, it was confirmed that the matching performance was superior even when 10° rotation was applied to the dataset. Therefore, it was confirmed that the matching algorithm of FAST-ORB combination could be suitable for matching between virtual texture image and real image.

The study of X-ray detection characteristic and fabrication photoconductor film thickness for Screen printing method (Screen printing method로 제작된 의료용 광도전체 필름의 Tickness의 따른 X선 검출 특성 평가)

  • Lee, Y.K.;Yon, M.S.;KIM, D.H.;Chun, S.L.;Jung, B.D.;Gang, Sang-Sik;Park, J.G.;Mun, C.W.;Nam, S.H.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.11-16
    • /
    • 2009
  • Mercury Iodide as good sensitivity at radiation and has an easy peculiarity that operates at low voltage for other photoconductors(a-Se, a-Si, Ge, etc) Based on this characteristic, we studied about an efficiency of the digital x-ray detector in acccordance with the thickness of photoconductor. To solve the problem that is difficult to make a large area film using PVD(Physical Vapor Deposition)method, we used a PIB(Particle In Binder)method. To make a binder paste, we used a PVB(Polyvinylbutyral) as a binder and a DGME(Diethylene Glycol Monobutyl Ether), DGMEA(Diethylene Glycol Monobutyl Ether Acetate) as a solvent. Using this binder paste, we made a polycrystal mercury iodide film that has an each thickness. To evaluate the electrical properties of this films, we measured a darkcurrent, sensitivity and SNR(Signal to Noise Ratio). Mercury iodide film of the 200um thickness has good electrical properties as a result of the measurement. From this result there is a good chance that replace the existing a-Se(Amnorphous seleinum; a-se) with the mercury iodide.

  • PDF

Analysis on the Dosimetric Characteristics of Tangential Breast Intensity Modulated Radiotherapy (유방암의 접선 세기조절 방사선치료 선량 특성 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Wong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.219-228
    • /
    • 2012
  • The tangential breast intensity modulated radiotherapy (T-B IMRT) technique, which uses the same tangential fields as conventional 3-dimensional conformal radiotherapy (3D-CRT) plans with physical wedges, was analyzed in terms of the calculated dose distribution feature and dosimetric accuracy of beam delivery during treatment. T-B IMRT plans were prepared for 15 patients with breast cancer who were already treated with conventional 3D-CRT. The homogeneity of the dose distribution to the target volume was improved, and the dose delivered to the normal tissues and critical organs was reduced compared with that in 3D-CRT plans. Quality assurance (QA) plans with the appropriate phantoms were used to analyze the dosimetric accuracy of T-B IMRT. An ionization chamber placed at the hole of an acrylic cylindrical phantom was used for the point dose measurement, and the mean error from the calculated dose was $0.7{\pm}1.4%$. The accuracy of the dose distribution was verified with a 2D diode detector array, and the mean pass rate calculated from the gamma evaluation was $97.3{\pm}2.9%$. We confirmed the advantages of a T-B IMRT in the dose distribution and verified the dosimetric accuracy from the QA performance which should still be regarded as an important process even in the simple technique as T-B IMRT in order to maintain a good quality.