• 제목/요약/키워드: Zygomatic fracture

검색결과 73건 처리시간 0.021초

관골복합골절 수술 후 발생한 일시적 설하신경 마비의 증례보고 (Transient Hypoglossal Nerve Palsy after Open Reduction of Zygomatic Complex Fracture)

  • 김지욱;김우섭;권남호;김한구;배태희
    • Archives of Plastic Surgery
    • /
    • 제36권1호
    • /
    • pp.80-83
    • /
    • 2009
  • Purpose: Isolated hypoglossal nerve palsy is a rare manifestation of various underlying disease. This article presents a rare complication of general anesthesia associated with an surgical procedure on a case of zygomatic fracture. Methods: An 18-year-old female patient was referred to our department by painful swelling on her left zygomatic area after the traffic accident. Left zygomatic complex fracture was identified on the simple x-ray and facial bone CT scan, and the fracture was treated with open reduction and internal fixation under general anesthesia. On the first postoperative day, she complained of difficulty in swallowing solid food, dysarthria and deviated tongue to her right side. There was no abnormal findings on the neurological examination, brain MRI and routine chemistry. She was diagnosed with transient hypoglossal nerve palsy and dexamethasone with multi-vitamins was administrated intravenously for 5 days. Results: The symptoms were completely resolved by the ninth postoperative day and the patient was discharged without any other complications. Conclusion: The hypoglossal(cranial nerve XII)nerve supplies motor innervation to all of the ipsilateral extrinsic and intrinsic tongue muscles. The hypoglossal nerve damage may caused by the compression between the airway and the hyoid bone during the endotracheal intubation, and direct trauma due to excessive pressure or neck extension. We described a rare case of unintended injury to hypoglossal nerve and care must be taken not to cause the hypoglossal nerve damage especially in facial plastic surgery with excessive neck extension under general anesthesia.

Inferomedially impacted zygomatic fracture reduction by reverse vector using an intraoral approach with Kirschner wire

  • Jang, Jin Woo;Cho, Jaeyoung;Burm, Jin Sik
    • Archives of Plastic Surgery
    • /
    • 제48권1호
    • /
    • pp.69-74
    • /
    • 2021
  • Background In inferomedially rotated zygomatic fractures sticking in the maxillary sinus, it is often difficult to achieve complete reduction only by conventional intraoral reduction. We present a new intraoral reduction technique using a Kirschner wire and its clinical outcome. Methods Among 39 inferomedially impacted zygomatic fractures incompletely reduced by a simple intraoral reduction trial with a bone elevator, a Kirschner wire (1.5 mm) was vertically inserted from the zygomatic body to the lateral orbital rim in 17 inferior-dominant rotation fractures and horizontally inserted to the zygomatic arch in nine medial-dominant and 13 bidirectional rotation fractures. A Kirschner wire was held with a wire holder and lifted in the superolateral or anterolateral direction for reduction. Following reduction of the zygomaticomaxillary fracture, internal fixation was performed. Results Fractures were completely reduced using only an intraoral approach with Kirschner wire reduction in 33 cases and through an additional lower lid or transconjunctival incision in six cases. There were no surgical complications except in one patient with undercorrection. Postoperative 6-month computed tomography scans showed complete bone union and excellent bone alignment. Four patients experienced difficulty with upper lip elevation; however, these problems spontaneously resolved after manual tissue lump massage and intralesional steroid (Triamcinolone) injection. Conclusions We completely reduced infraorbital rim fractures, zygomaticomaxillary buttresses, and zygomaticofrontal suture fractures in 84% of patients through an intraoral approach alone. Intraoral Kirschner wire reduction may be a useful option by which to obtain effective and powerful reduction motion of an inferomedially rotated zygomatic body.

Thermo-splint를 이용한 불안정한 관골궁골절에 대한 효과적인 고정방법 (The Effective Reduction Method of Unstable Zygomatic Arch Fracture with Thermo-Splint)

  • 김순흠;이수향;최현곤;신동혁;엄기일;송우철
    • Archives of Plastic Surgery
    • /
    • 제35권1호
    • /
    • pp.110-115
    • /
    • 2008
  • Purpose: The objective of this study is to propose an effective management of unstable zygomatic arch fracture. The reduction methods of arch fracture were relatively simple but the maintenance of reduction state is very troublesome. On this, authors introduce an effective management method of unstable zygomatic arch fracture. Methods: Authors experienced 23 cases of unstable segmental zygomatic arch fractures and used Thermo-splint in all cases. All the arch fractures were reduced through Gillies' approach under the general anesthesia. After the reduction, the most effective suspension points were marked on the covering skin of the fractured arch. A needle of heavy nonabsorbable suture material was inserted toward the marking site under the reduced zygomatic arch. And then Therm-splint was dipped in the hot water, and we got the splint pattern of patient face. Reshaped Thermo-splint was trimmed and fixated with previous suspension suture materials. More additive suspension was done if necessary. The splint was applied for in two to three weeks postoperatively. Results: In all the cases, good cosmetic and functional results were observed without severe complications. There were 4 cases of incomplete reductions but they also had no specific problems. There were no facial nerve symptom and scar(stitch mark). Postoperative slight tenderness and trismus were completely subsided after removal of the splint. Conclusion: The Thermo-splint safely protect and maintain the postoperative reduction state. The application, maintenance and removal were easy and simple. It could be reformed to any contour of face and had enough rigidity for supporting. Above all these things, effective prevention of displacement and easy manipulation were significant merit. Authors experienced good results with Thermo-splint, and would introduce it for another method of management of zygomatic arch fracture.

강선 고정술을 이용한 관골골절의 치료 (Intraoral Approach and K-Wire Fixation of Zygomatic Tripod Fractures)

  • 최시호
    • Journal of Yeungnam Medical Science
    • /
    • 제5권1호
    • /
    • pp.85-92
    • /
    • 1988
  • 저자는 관골 골절 환자중 일부 안서 골절로 안와내용물의 탈출이 동반된 관골 골절, 경구개 골절이 동반된 관골 골절, 소아의 관골 골절을 제외한 대다수의 삼격면 관골 골절 환자 37례를 구강내 절개와 K-강선고정술을 이용하여 수술 하였던 바, 첫째, 안면부 반흔을 남기지 않고, 둘째, 간단하며, 셋째, 직시하 수술이 가능하며 만족할 만한 결과를 얻을 수 있었다.

  • PDF

Wire or Hook Traction for Reducing Zygomatic Fracture

  • Ahn, Hee Chang;Youn, Dong Hyun;Choi, Matthew Seung Suk;Chang, Jung-Woo;Lee, Jang Hyun
    • 대한두개안면성형외과학회지
    • /
    • 제16권3호
    • /
    • pp.131-135
    • /
    • 2015
  • Background: Variable methods have been introduced for reduction of the zygomatic fractures. The Dingman elevator is used widely to reduce these fractures but is inappropriate in certain types of fractures which require atypical traction vectors. We introduce and examine an alternate method of reducing zygomatic fractures using wire and hook traction. Methods: A retrospective study was performed for all zygomatic fracture patients admitted between 2008 and 2014. Medially rotated fractures were reduced by using a wire looped through an intermaxillary screw secured on the medial side of the zygoma. Laterally rotated fractures were reduced using a hook introduced through an infrazygomatic skin incision. Results: No accidental bleeding or incomplete reduction was observed in any of the cases. Postoperative imaging demonstrated proper reduction immediately after the operation. Follow-up computed tomography study at 1 month after operation also demonstrated proper reduction and healthy union across the previous site of fracture. Conclusion: The hook and wire method allowed precise application of traction forces across zygomatic fractures. The fractured bone fragment could be pulled in the direction precisely opposite to the vector of impact at the time of trauma. Soft tissue damage due to dissection was minimized. In particular, this method was effective in reducing rotated bone fragments and can be an alternative option to using the zygoma elevator.

Discrepancy of the location of depression on the soft tissue and the bone in isolated zygomatic arch fracture

  • Yong Jig Lee;Dong Gil Han;Se Hun Kim;Jeong Su Shim;Sung-Eun Kim
    • 대한두개안면성형외과학회지
    • /
    • 제24권1호
    • /
    • pp.18-23
    • /
    • 2023
  • Background: When performing reduction of zygomatic arch fractures, locating the inward portion of the fracture can be difficult. Therefore, this study investigated the discrepancy between the locations of the depression on the soft tissue and bone and sought to identify how to determine the inward portion of the fracture on the patient's face. Methods: We conducted a retrospective review of chart with isolated zygomatic arch fractures of type V in the Nam and Jung classification from March 2013 to February 2022. For consistent measurements, a reference point (RP), at the intersection between a vertical line passing through the end point of the root of the ear helix in the patient's side-view photograph and a transverse line passing through the longest horizontal axis of the external meatus opening, was established. We then measured the distance between the RP and the soft tissue depression in a portrait and the bone depression on a computed tomography (CT) scan. The discrepancy between these distances was quantified. Results: Among the patients with isolated zygomatic arch fractures, only those with a fully visible ear on a side-view photograph were included. Twenty-four patients met the inclusion criteria. There were four types of discrepancies in the location of the soft tissue depression compared to the bone depression: type I, forward and upward discrepancy (7.45 and 3.28 mm), type II, backward and upward (4.29 and 4.21 mm), type III, forward and downward (10.06 and 5.15 mm), and type IV, backward and downward (2.61 and 3.27 mm). Conclusion: This study showed that discrepancy between the locations of the depressions on the soft tissue and bone exists in various directions. Therefore, applying the transverse and vertical distances measured from a bone image of the CT scan onto the patient's face at the indicated RP will be helpful for predicting the reduction location.

C-arm 투시하에서 관골궁 골절의 비관혈적 정복술에 관한 고찰 (C-arm Guided Closed Reduction of Zygomatic Arch Fracture)

  • 어윤기;이동근;김정삼;장영일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권2호
    • /
    • pp.23-26
    • /
    • 1999
  • The Zygomatic arch is structurally protruded and is easily fractured. The classic management of zygomatic arch fracture has been mentioned the Keen, Lothrop, Dingman and Ailing and threaded K-wire. All of the above methods have advantages and disadvantages. To minimize the disadvantages, we performed threaded K-wire for the first time using C-arm image intensifier. The subjects were 16 patients with Knight North group II (Zygomatic arch fracture). Among them the C-arm was used in 12 patients and the operator used sensitivity general method in 4 patients and confirmed the operation by mobile X-ray equipment. In conclusion, both groups were satisfied surgically and cosmetically. Using the C-arm, actual image at the time operation was clear and satisfied, the surrounding tissue damage was minimized and at was more accurately completed. The operation time was shortened by 30 to 60 minutes proving it to be an efficient method. We suggest though that further studies be needed to evaluate the radiation effect on these patients.

  • PDF

Three-dimensional intraoperative computed tomography imaging for zygomatic fracture repair

  • Peleg, Oren;Ianculovici, Clariel;Shuster, Amir;Mijiritsky, Eitan;Oz, Itay;Kleinman, Shlomi
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권5호
    • /
    • pp.382-387
    • /
    • 2021
  • Objectives: Zygomatic complex (ZMC) fractures comprise up to 40% of all facial fractures. Misaligned bone fragments and misplaced fixation hardware traditionally detected postoperatively on plain radiographs of the skull might require re-operation. The intraoperative O-Arm (Medtronic, USA) is a three-dimensional (3D) computed tomographic imaging system. Materials and Methods: This retrospective single-center study evaluated the utility of O-Arm scanning during corrective surgeries for ZMC and zygomatic arch (ZA) fractures from 2018 to 2020. Three females and 16 males (mean age, 31.52 years; range, 22-48 years) were included. Fracture instability (n=6) and facial deformity (n=15) were the most frequent indications for intraoperative 3D O-Arm scan. Results: The images demonstrated that all fracture lines were properly reduced and fixed. Another scan performed at the end of the fixation or reduction stage, however, revealed suboptimal results in five of the 19 cases, and further reduction and fixation of the fracture lines were required. Conclusion: Implementation of an intraoperative O-Arm system in ZMC and ZA fracture surgeries assists in obtaining predictable and accurate results and obviates the need for revision surgeries. The device should be considered for precise operations such as ZMC fracture repairs.

관골궁 골절의 정복 시 술중 이동식 CT의 유용성 (Closed Reduction of Zygomatic Arch Fracture with Intraoperative Mobile Computed Tomography Scan)

  • 김명국;노용준;이훈영;김민호;이신철
    • Archives of Plastic Surgery
    • /
    • 제37권1호
    • /
    • pp.91-94
    • /
    • 2010
  • Purpose: The purpose of this study is to describe the usefulness of intraoperative mobile CT scans in the reduction of zygomatic arch fracture. Method: Two patients with zygomatic arch fractures were selected who were indications of closed reduction by Gilles' approach. After the reduction was done in the operating room with zygomatic arch elevator, intraoperative CT scan was done to check the extent of reduction. Additional reduction was performed according to the obtained images from the intraoperative mobile CT scan. Examination of the preoperative CT, intraoperative CT after the reduction, and postoperative plain X-ray films were done for documentation and analysis. Results: Reduction was carried out successfully to the patients without any complications. Both patients were satisfied with the postoperative cosmetic and functional outcome. Revisional surgery was not necessary during the 6 months follow up. Conclusion: The advantage of this method is that it is easier to obtain three dimensional relationships of the fracture site. Furthermore, the operator is less exposed to radiation hazards compared to other methods that obtain intraoperative images such as the C-arm. In conclusion, intraoperative mobile CT scan can be a useful surgical aid in the reduction of zygomatic arch fractures.

An Anthropometric and Three-Dimensional Computed Tomographic Evaluation of Two-Point Fixation of Zygomatic Complex Fractures

  • Jo, Taehee;Kim, Junhyung
    • Archives of Plastic Surgery
    • /
    • 제41권5호
    • /
    • pp.493-499
    • /
    • 2014
  • Background Maintaining stability and restoring the aesthetic appearance are the fundamental goals when managing zygomatic fractures. We aimed to evaluate the stability and anthropometric outcomes of zygomatic fracture patients who underwent two-point fixation involving the infraorbital rim and zygomaticomaxillary buttress via the transconjunctival and gingivobuccal approaches without any skin incisions. Methods We examined 15 zygomatic fracture patients who underwent two-point fixation during a 3-year period. Stability was evaluated using three-dimensional facial bone computed tomography. Superoinferior and anteroposterior displacement of the zygoma was quantified. The aesthetic appearance of the periorbital region was evaluated using indirect anthropometry with standardized clinical photographs. The ratios between the eye fissure height and width, and lower iris coverage ratio were used to evaluate aesthetical changes. The bony displacement and aesthetic ratios were analyzed using Wilcoxon or Friedman tests. The correlation between the preoperative zygoma position and anthropometric values was analyzed. Results The positions of the zygoma were similar to those on the contralateral side at the long-term follow-up. The preoperative anthropometric measurements on the fractured side differed from those on the contralateral side, although these values were close to the normal values at the long-term follow-up. Furthermore, we noted that the anteroposterior displacement strongly positively correlated with the lower iris coverage rate (Spearman's coefficient=0.678, P=0.005). Conclusions Two-point fixation of zygomatic fractures achieved stable outcomes on long-term follow-up, and also appeared to be reliable in restoring the aesthetic appearance of the periorbital region.