C-arm Guided Closed Reduction of Zygomatic Arch Fracture

C-arm 투시하에서 관골궁 골절의 비관혈적 정복술에 관한 고찰

  • Eo, Yoon-Ki (Team of Diagnostic Radiology. Wonkwang University Hospital) ;
  • Lee, Dong-Kun (Team of Diagnostic Radiology. Wonkwang University Hospital) ;
  • Kim, Jeong-Sam (Dept. of Radiotechnology, Kwang Yang College) ;
  • Jang, Young-Il (Dept. of Radiotechnology, Kwang Yang College)
  • 어윤기 (원광대학병원 진단방사선팀) ;
  • 이동근 (원광대학병원 진단방사선팀) ;
  • 김정삼 (광양대학 방사선과) ;
  • 장영일 (광양대학 방사선과)
  • Published : 1999.12.30

Abstract

The Zygomatic arch is structurally protruded and is easily fractured. The classic management of zygomatic arch fracture has been mentioned the Keen, Lothrop, Dingman and Ailing and threaded K-wire. All of the above methods have advantages and disadvantages. To minimize the disadvantages, we performed threaded K-wire for the first time using C-arm image intensifier. The subjects were 16 patients with Knight North group II (Zygomatic arch fracture). Among them the C-arm was used in 12 patients and the operator used sensitivity general method in 4 patients and confirmed the operation by mobile X-ray equipment. In conclusion, both groups were satisfied surgically and cosmetically. Using the C-arm, actual image at the time operation was clear and satisfied, the surrounding tissue damage was minimized and at was more accurately completed. The operation time was shortened by 30 to 60 minutes proving it to be an efficient method. We suggest though that further studies be needed to evaluate the radiation effect on these patients.

Keywords