A Numerical Study on the Laminar Flow Field and Heat Transfer Coefficient Distribution for Supercritical Water in a Tube

  • Lee Sang-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.4
    • /
    • pp.206-216
    • /
    • 2005
  • Numerical analysis has been carried out to investigate laminar convective heat transfer at zero gravity in a tube for supercritical water near the thermodynamic critical point. Fluid flow and heat transfer are strongly coupled due to large variation of thermodynamic and transport properties such as density, specific heat, viscosity, and thermal conductivity near the critical point. Heat transfer characteristics in the developing region of the tube show transition behavior between liquid-like and gas-like phases with a peak in heat transfer coefficient distribution near the pseudo critical point. The peak of the heat transfer coefficient depends on pressure and wall heat flux rather than inlet temperature and Reynolds number. Results of the modeling provide convective heat transfer characteristics including velocity vectors, temperature, and the properties as well as the heat transfer coefficient. The effect of proximity on the critical point is considered and a heat transfer correlation is suggested for the peak of Nusselt number in the tube.

Design Optimization of Capacitor-less DRAM using zero-temperature coefficient point (트랜지스터의 온도 계수를 고려한 커패시터리스 디램의 설계 최적화)

  • Kyung Hee Kim;Kyeong Min Kim;Yeong Hwan Kim;Jong Beom Im;Gyu Ho Choi;In Man Kang;Young Jun Yoon
    • Journal of IKEEE
    • /
    • v.28 no.3
    • /
    • pp.369-374
    • /
    • 2024
  • This paper addresses the design optimization of capacitorless DRAM(one-transistor DRAM., 1T-DRAM), which has gained attention as a next-generation memory technology. To overcome the limitations of conventional capacitor-based DRAM, an asymmetric dual-gate structure is proposed to enhance retention time and overall performance. The zero-temperature coefficient (ZTC) point is set at 1.25 V to minimize performance degradation due to temperature variations. Current-voltage characteristics were analyzed at various temperatures (300K-400K), confirming stable memory operation at the ZTC point, even under temperature fluctuations. The proposed design demonstrates reliable operation at high temperatures, proving the potential for high-efficiency, highly reliable memory technology. As a result, the 1T-DRAM device can make a significant contribution to the development of next-generation memory devices.

Diagnostic methods applied to Esfahan light water subcritical reactor (ELWSCR)

  • Arkani, Mohammad
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2133-2150
    • /
    • 2021
  • In this work, Esfahan light water subcritical reactor (ELWSCR) is analysed using experimental and theoretical diagnostic methods. Important neutronic parameters of the system such as prompt neutron lifetime, delayed neutron fraction, prompt neutron decay constant, negative reactivity of the core, fuel and moderator temperature coefficient of reactivity, and overall and local void coefficient of reactivity are estimated. Also, neutron flux distribution, reflector saving, water level effect, and lattice pitch of the core including operating point of the facility are studied in details. Theoretical results are calculated by MCNPX and measurements are performed utilizing zero power reactor noise method. Detailed descriptions of the results are explained in the text.

Arc Extinguishment for Low-voltage DC (LVDC) Circuit Breaker by PPTC Device (PPTC 소자를 사용한 저전압 직류차단기의 아크소호기술)

  • Kim, Yong-Jung;Na, Jeaho;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.5
    • /
    • pp.299-304
    • /
    • 2018
  • An ideal circuit breaker should supply electric power to loads without losses in a conduction state and completely isolate the load from the power source by providing insulation strength in a break state. Fault current is relatively easy to break in an Alternating Current (AC) circuit breaker because the AC current becomes zero at every half cycle. However, fault current in DC circuit breaker (DCCB) should be reduced by generating a high arc voltage at the breaker contact point. Large fire may occur if the DCCB does not take sufficient arc voltage and allows the continuous flow of the arc fault current with high temperature. A semiconductor circuit breaker with a power electronic device has many advantages. These advantages include quick breaking time, lack of arc generation, and lower noise than mechanical circuit breakers. However, a large load capacity cannot be applied because of large conduction loss. An extinguishing technology of DCCB with polymeric positive temperature coefficient (PPTC) device is proposed and evaluated through experiments in this study to take advantage of low conduction loss of mechanical circuit breaker and arcless breaking characteristic of semiconductor devices.

Performance Analysis of a Geothermal Heat Pump System Operated by a Diesel Engine (I) - Soil temperature prediction in Pusan and Chinju - (엔진구동 지열 열펌프의 성능 분석 (I) - 부산.진주지방 지중온도 예측 -)

  • 김영복
    • Journal of Biosystems Engineering
    • /
    • v.23 no.2
    • /
    • pp.135-146
    • /
    • 1998
  • The equation to predict the soil temprature of Pusan and Chinju city as a function of time and soil depth for the geothermal energy utilization system and agriculture was devised. The equation was $T(x,t)\;=\;Tm\;-\;To{\cdot}ExP(-{\xi}){\cdot}cos{{\omega}{\cdot}[t-to-x/(2{\cdot}{\alpha}{\cdot}{\omega})^{0.5}]}$ with the soil thermal diffusivity, ${\alpha},\;of\;0.4\;\textrm{m}^2/day,\;0.0375\;\textrm{m}^2/day$ and phase zero point, to, of 24 days, 22.4 days in Pusan and Chinju city, respectively, during ten years from 1987 to 1996. The predicted and measured soil temperatures agreed well with the coefficient of determination of 0.95 at the soil depth of 0.0, 0.5, 1.0, 3.0, 5.0 m. The maximum and minimum temperature in Pusan 3.7, $30.1^{\circ}C$ at soil surface and 14.3, $18.0^{\circ}C$ at the depth of 5.0 m. The total mean temperature of soil in Pusan and Chinju city was about 16.3, $16.0^{\circ}C$, respectively.

  • PDF

A Study of Suppression Current for LDMOS under Variation of Temperature (온도변화에 따른 LDMOS의 전류변동 억제에 관한 연구)

  • Jeon, Joong-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.8
    • /
    • pp.901-906
    • /
    • 2006
  • In this paper, the power amplifier using active bias circuits for LDMOS(Lateral Diffused Metal Oxide Semiconductor) MRF-21180 is designed and fabricated. According to change the temperature, the gate voltage of LDMOS is controlled by the fabricated active bias circuits which is made of PNP transistor to suppress drain current. The driving amplifier using MRF-21125 and MRF-21060 is made to drive the LDMOS MRF-21180 power amplifier. The variation of current consumption in the fabricated 60 watt power amplifier has an excellent characteristics of less than 0.1 A, whereas a passive biasing circuit dissipates more than 0.5 A. The implemented power amplifier has the gain over 9 dB, the gain flatness of less than $\pm$0.1 dB and input and output return loss of less than -6 dB over the frequency range 2.11 $\sim$ 2.17 GHz. The DC operation point of this power amplifier at temperature variation 0 $^{\circ}C$ to 60 $^{\circ}C$ is fixed by active bias circuit.

Design Analysis/Manufacturing /Performance Evaluation of Curved Unsymmetrical Piezoelectric Composite Actuator LIPCA (곡면형 비대칭 압전복합재료 작동기 LIPCA의 설계해석/제작/성능평가)

  • Gu, Nam-Seo;Sin, Seok-Jun;Park, Hun-Cheol;Yun, Gwang-Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.10
    • /
    • pp.1514-1519
    • /
    • 2001
  • This paper is concerned with design, manufacturing and performance test of LIPCA ( Lightweight Piezo- composite Curved Actuator) using a top carbon fiber composite layer with near -zero CTE(coefficient of thermal expansion), a middle PZT ceramic wafer and a bottom glass/epoxy layer with high CTE. The main point of this design is to replace the heavy metal layers of THUNDER by thigh tweight fiber reinforced plastic layers without losing capabilities to generate high force and large displacement. It is possible to save weight up to about 30% if we replace the metallic backing material by the light fiber composite layer. We can also have design flexibility by selecting the fiber direction and the size of prepreg layers. In addition to the lightweight advantage and design flexibility, the proposed device can be manufactured without adhesive layers when we use epoxy resin prepreg system. Glass/epoxy prepregs, a ceramic wafer with electrode surfaces, and a graphite/epoxy prepreg were simply stacked and cured at an elevated temperature (177 $^{circ}C$ after following an autoclave bagging process. It was found that the manufactured composite laminate device had a sufficient curvature after detached from a flat mold. The analysis method of the cure curvature of LIPCA using the classical lamination theory is presented. The predicted curvatures are fairly in agreement with the experimental ones. In order to investigate the merits of LIPCA, a performance test of both LIPCA and THUNDE$^{TM}$ were conducted under the same boundary conditions. From the experimental actuation tests, it was observed that the developed actuator could generate larger actuation displacement than THUNDERT$^{TM}$.

Evaluation and Prediction of Color Changes of Sugar-Glycine Mixtures by Maillard Reaction (마이야르 반응에 의한 당과 글리신 혼합물의 색변화의 평가와 예측)

  • Kim, Woo-Jung;Chun, Young-Hye;Sung, Hyun-Soon
    • Korean Journal of Food Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.306-312
    • /
    • 1986
  • Color changes of a mixture of 0.8 M glucose, fructose or sucrose and 0.8 M glycine were evaluated by Hunter 'L', 'a', 'b' values during Maillard reaction at the temperature range of $70^{\circ}-100^{\circ}C$. The results suggested the reaction to be devided into three stages. In initial reaction the 'L' and 'a' values decreased slowely, and 'b' rapidly increased to maximum, which were followed by a rapid decrease in 'L' and 'b' and rapid increase in 'a' values at intermediate stage. At final reaction period the both 'L' and 'b' were slowed down in their reduction rate while 'a' decreased rapidly from its maximum point. All of the Hunter values were reached to nea. zero. Linear equations, which can be used for prediction of cole. change in Maillared reaction, of $1/\sqrt{(L_t-L_{\circ})^2\;+\;(a_t-a_{\circ})^2\;+\;(b_t-b_{\circ})^2}\;=\;a(1/t)\;+\;b$ for Hunter values and $1/\sqrt{X\;+\;Y\;+Z}\;=\;a(1/t)\;+\;b$ for CIE tristimulus values were found to have a very high correlation coefficient. Relationships between 'L' and 'a', 'L' and 'b' and 'a' and 'b' were also graphcally compared.