• 제목/요약/키워드: Zero-phase current transformer

검색결과 56건 처리시간 0.027초

철도차량 보조전원용 Three-Level ZVZCS DC/DC 컨버터 (Three-Level ZVZCS DC/DC Converter using a Assistance Power Sources of the RailRoad Vehicles)

  • 노성찬;임응규;양성혁;김윤호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.880-885
    • /
    • 2003
  • Using a Assistance Power Sources of the Railroad Vehicles Three-Level ZVZCS DC/DC Converter is presented in this paper. The proposed three-Level DC/DC Converter Is to achieved zero voltage and zero current switching for the two Main switches. phase shift method is used a parastic capacitance by reverse recovery characteritics in a inner diode of the switching device. Also. using a diode second part of the Transformer by the simple auxiliary circuit for the achieved zero current switching of the Auxiliary switch. For the ZVZCS movement of the all switching devices is analyzed and verified under a 5kW, in the 100kHz switching frequency.

  • PDF

3[kW]급 주택용 연료전지시스템에 사용되는 새로운 DC-DC 컨버터 (A novel DC-DC Converter for 3[kW] Fuel Cell System Residential Application)

  • 이수호;문상필;이현우;서기영;권순걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.362-364
    • /
    • 2006
  • This paper presents a novel DC-DC Converter for 3 [kW] Fuel Cell System Residential Application. Phase shifted control is employed to regulate the output voltage and achieve soft switching. The transformer leakage inductance is utilized effectively to achieve zero voltage turn on for the power semiconductor switches. The current doubler rectifier has only one diode drop. The transformer secondary winding current rating is one half the load current. The overall effciency of the converter is improved.

  • PDF

위상전이 풀-브리지 DC/DC 컨버터를 이용한 차세대 고속 전철용 Battery Charger에 관한 연구 (A Study on Battery Chargers for the next generation high speed train using the Phase-shift Full-bridge DC/DC Converter)

  • 조한진;이원철;이상석;김태환;원충연
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.623-628
    • /
    • 2009
  • There is an increasing demand for efficient high power/weight auxiliary power supplies for use on high speed traction application. Many new conversion techniques have been proposed to reduce the voltage and current stress of switching components, and the switching losses in the traditional pulse width modulation(PWM) converter. Especially, the phase shift full bridge zero voltage switching PWM techniques are thought most desirable for many applications because this topology permits all switching devices to operate under zero voltage switching(ZVS) by using circuit parasitic components such as leakage inductance of high frequency transformer and power device junction capacitance. The proposed topology is found to have higher efficiency than conventional soft-switching converter. Also it is easily applicable to phase shift full bridge converter by applying an energy recovery snubber consisted of fast recovery diodes and capacitors.

  • PDF

불평형전류 측정에 의한 회전기 열화감시장치 (Deterioration Monitoring Device by Unbalance Current Measurement of Rotating Machines)

  • 박찬용;박대원;류길수;길경석;이강원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.2035-2039
    • /
    • 2008
  • This paper described an on-line condition monitoring device for rotating machines by measurement of unbalance current due to insulation deterioration. The device consists of a zero-phase current transformer (ZCT), a low-noise amplifying circuit, and a microprocessor unit. The prototype device measures current of $500\;{\mu}A\;{\sim}\;30\;mA$ in frequency ranges from 10 Hz to 3 kHz. An application experiment was carried out on 3-phase induction motors and we could measure current changes caused by a short-circuited turn.

  • PDF

FB ZVT PWM 컨버터의 환류구간 손실저감을 위한 보조회로 (An auxiliary circuit for reducing loss during free-wheeling interval in FB ZVT PWM converter)

  • 윤창선;김병철;김광헌
    • 전력전자학회논문지
    • /
    • 제5권3호
    • /
    • pp.209-214
    • /
    • 2000
  • 본 논문에서는 FB ZVT PWM DC-DC 컨버터에서 영전압 스위칭에 도달하기 위해 두 개의 보조 스위치 대신에 가포화 인덕터를 사용한다. 기존의 고주파 위상 변위 FB ZVT PWM DC-DC 컨버터는 프리휠링 주기동안 고주파 변압기와 스위칭 소자를 통해 흐르는 순환전류를 갖으며, 이러한 순환전류로 인해 컨버터의 도전손실이 증가한다. 이러한 손실을 줄이기 위해 변압기의 2차측에 도전손실저감회로를 제안한다. 컨버터의 동작원리를 자세하게 설명하고 제안된 회로를 시뮬레이션과 실험을 통해 검증하였다.

  • PDF

차세대 고속 전철용 Battery Charger 에 관한 연구 (A Study on the Battery Charger for Next Generation High Speed Train)

  • 정한정;이원철;이상석;백진성;원충연
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.321-324
    • /
    • 2008
  • Recently, there is an increasing demand for efficient high power/weight auxiliary power supplies for use on high speed traction application. many new conversion techniques have been proposed to reduce the voltage and current stress of switching components, and the switching losses in the traditional pulse width modulation(PWM) converter. Among them, the phase shift full bridge zero voltage switching PWM techniques are thought most desirable for many applications because this topology permits all switching devices to operate under zero voltage switching(ZVS) by using circuit parasitic components such as leakage inductance of high frequency transformer and power device junction capacitance. The proposed topology is found to have higher efficiency than conventional soft-switching converter. Also it is easily applicable to phase shift full bridge converter by applying an energy recovery snubber consisted of fast recovery diodes and capacitors.

  • PDF

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Journal of Power Electronics
    • /
    • 제3권3호
    • /
    • pp.151-158
    • /
    • 2003
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other This may result in wiring failure of the neutral conductor and overloading of the distribution transformer In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system This remedies overloading and power loss of the system The experimental results on a prototype validate the proposed control approach.

전기설비의 저항성 누설전류 검출 및 특성 해석에 관한 연구 (Study on the Resistivity Leakage Current Detection and Properties Analysis of Electrical Installat ion)

  • 최충석;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.301-304
    • /
    • 2008
  • In this paper, we study from of flowing leakage current in electrical installation. Leakage current is expressed by a resistivity leakage current($I_{gr}$), a capacitive leakage current($I_{gc}$), an inductivity leakage current($I_{gl}$). General Zero Phase Current Transformer (ZCT) detect a leakage current($I_{g}$) that are conjoined resistivity leakage current and capacitive leakage current. In case $I_{gr}$ is big than $I_{gc}$, there is no singular problem in leakage current detection of system. But, in case $I_{gc}$ is big than $I_{gr}$, earth leakage breaker can not prevent accident effectively. Can lower electric leakage perception current to 5 mA if apply resistivity leakage current detecting circuit. We can achieve prevention of electricity disaster spontaneously.

  • PDF

High Step-up Active-Clamp Converter with an Input Current Doubler and a Symmetrical Switched-Capacitor Circuit

  • He, Liangzong;Zeng, Tao;Li, Tong;Liao, Yuxian;Zhou, Wei
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.587-601
    • /
    • 2015
  • A high step-up dc-dc converter is proposed for photovoltaic power systems in this paper. The proposed converter consists of an input current doubler, a symmetrical switched-capacitor doubler and an active-clamp circuit. The input current doubler minimizes the input current ripple. The symmetrical switched-capacitor doubler is composed of two symmetrical quasi-resonant switched-capacitor circuits, which share the leakage inductance of the transformer as a resonant inductor. The rectifier diodes (switched-capacitor circuit) are turned off at the zero current switching (ZCS) condition, so that the reverse-recovery problem of the diodes is removed. In addition, the symmetrical structure results in an output voltage ripple reduction because the voltage ripples of the charge/pump capacitors cancel each other out. Meanwhile, the voltage stress of the rectifier diodes is clamped at half of the output voltage. In addition, the active-clamp circuit clamps the voltage surges of the switches and recycles the energy of the transformer leakage inductance. Furthermore, pulse-width modulation plus phase angle shift (PPAS) is employed to control the output voltage. The operation principle of the converter is analyzed and experimental results obtained from a 400W prototype are presented to validate the performance of the proposed converter.

삼상 분리형 자속커플링 전류제한기의 턴 수의 따른 전류제한 특성 (Characteristics according to turn ratio of Separated Three-Phase Flux-Coupling Type Superconducting Fault Current Limiter(SFCL))

  • 김용진;두호익;두승규;김민주;이동혁;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.344-345
    • /
    • 2009
  • The flux-coupling type superconducting fault current limiter(SFCL) is composed of a series transformer and superconducting unit of the YBCO coated conductor. The primary and secondary coils in the transformer were wound in series each other through an iron core and the YBCO coated conductor was connected with secondary coil in parallel. In a normal condition, the flux generated from a primary coil is cancelled out by its structure and the zero resistance of the YBCO thin films. When a fault occurs, the resistance of the YBCO coated conductor was generated and the fault current was limited by the SFCL. In this paper, we investigated the fault current limiting characteristics according to turn ratio in the flux-coupling type SFCL. The experiment results that the fault current limiting characteristics was improved according to turn ratio.

  • PDF