• 제목/요약/키워드: Z-scan method

검색결과 38건 처리시간 0.029초

레이저 스케너를 이용한 측정시 오차감소에 관한 연구 (A Study on reducing errors in scanning object using a laser s)

  • 홍성균;이희관;공영식;양균의
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.393-398
    • /
    • 2002
  • This study proposes a method to reduce error scanning data of laser scanner. The method co of 3 stages. First, there is an error indu difference of the distance between the prob the object. It is possible to reduce the e planning a scanning strategy: object settin path. Second, the scan data loss of the tooli affects calculating the tooling ball con z-direction compensation is given to calculat accurate registration points. Third, three p used to determine a transformation matrix on frame. As merging, the maximum error usually on the third tooling ball in the conven method, which select a point among three po randomly. We find the centroid of 3 points apply it to determine a new transformation mat

  • PDF

High Resolution 3D Magnetic Resonance Fingerprinting with Hybrid Radial-Interleaved EPI Acquisition for Knee Cartilage T1, T2 Mapping

  • Han, Dongyeob;Hong, Taehwa;Lee, Yonghan;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권3호
    • /
    • pp.141-155
    • /
    • 2021
  • Purpose: To develop a 3D magnetic resonance fingerprinting (MRF) method for application in high resolution knee cartilage PD, T1, T2 mapping. Materials and Methods: A novel 3D acquisition trajectory with golden-angle rotating radial in kxy direction and interleaved echo planar imaging (EPI) acquisition in the kz direction was implemented in the MRF framework. A centric order was applied to the interleaved EPI acquisition to reduce Nyquist ghosting artifact due to field inhomogeneity. For the reconstruction, singular value decomposition (SVD) compression method was used to accelerate reconstruction time and conjugate gradient sensitivity-encoding (CG-SENSE) was performed to overcome low SNR of the high resolution data. Phantom experiments were performed to verify the proposed method. In vivo experiments were performed on 6 healthy volunteers and 2 early osteoarthritis (OA) patients. Results: In the phantom experiments, the T1 and T2 values of the proposed method were in good agreement with the spin-echo references. The results from the in vivo scans showed high quality proton density (PD), T1, T2 map with EPI echo train length (NETL = 4), acceleration factor in through plane (Rz = 5), and number of radial spokes (Nspk = 4). In patients, high T2 values (50-60 ms) were seen in all transverse, sagittal, and coronal views and the damaged cartilage regions were in agreement with the hyper-intensity regions shown on conventional turbo spin-echo (TSE) images. Conclusion: The proposed 3D MRF method can acquire high resolution (0.5 mm3) quantitative maps in practical scan time (~ 7 min and 10 sec) with full coverage of the knee (FOV: 160 × 160 × 120 mm3).

GC-MS를 이용한 황벽의 색소 성분 분리 거동 (Separation of Chromophoric Substance from Amur Cork Tree Using GC-MS)

  • 안춘순
    • 한국의류학회지
    • /
    • 제33권6호
    • /
    • pp.980-989
    • /
    • 2009
  • 본 연구는 황벽으로부터 추출하는 염료를 가스 크로마토그라피 질량분석기로 분석할 때 berberine 색소를 가장 효과적으로 검출할 수 있도록 추출방법을 표준화하고 적절한 GC-MS 분석방법을 찾는데 목적을 둔다. 항온진탕기와 가열판을 이용한 다양한 추출법을 적용하였으며 GC 컬럼내 온도조작과 MSD 스캔범위에 따라 5종류의 GC-MS 분석방법의 유효성을 검사하였다. Berberine 표준색소와 추출염료 내 berberine 화합물의 유무는 r.t. 15.0분에서 dihydroberberine의 검출로 확인하였다. 가열판 추출이 항온진탕기 추출보다 더 효과적으로 나타났으며 이는 추출 전 실온에서 사전침지를 한 경우와 하지 않은 경우 모두 동일하였다. 물을 이용한 추출은 berberine 검출에 적합하지 않은 것으로 확인되었다. 본 연구에서 도입한 다섯가지 GC-MS 방법 중 berberine 검출에 가장 효과적인 방법은 Method 4였으며 그 조건은, GC 컬럼내초기온도를 $50^{\circ}C$로 하고 $23^{\circ}C$/분 비율로 온도를 올려 $210^{\circ}C$에 달하면 다시 $30^{\circ}C$/분 비율로 온도를 올려 최종온도 $305^{\circ}C$에 도달했을 때 14분간 온도를 그대로 유지하여 전체 분리시간을 24.12분으로 하며 질량 분석기의 스캔 범위는 $35\sim400$m/z로 하는 것이다.

Crystal Structure of Byakangelicin ($C_{17}H_{18}O_{7}$)

  • Kim, Yang-Bae;Oh, Yong-Ho;Park, Il-Yeung;Shin, Kuk-Hyun
    • Archives of Pharmacal Research
    • /
    • 제25권3호
    • /
    • pp.275-279
    • /
    • 2002
  • The crystal structure of byakangelicin, one of furanocoumarin aldose reductase inhibitors, was determined by X-ray diffraction method. The crystal is triclinic, with a=8.114(1), b=10.194(1), $c=11.428(1)\AA,{\;}{\alpha}=111.50(1),{\}{\beta}=95.57(1),{\}{\gamma}=112.52(1)^{circ},{\;}D_x=1.41,{\;}D_m=1.39{\;}g/cm^3$, space group P1 and Z=2. The intensity data were collected by ${\omega}-2{\theta}$ scan method with $CuK_{a}$ radiations. The structure was solved by direct method and refined by full matrix least-squares procedure to the final R-value of 0.056. There are two molecules with different conformations in an asymmetric unit. The molecules are kept by two intermolecular O-HO type hydrogen bonds and van der Waal's forces in the crystal. The absolute configuration of the molecules was estimated to S-form by the 'Eta refinement' procedure.

디클로벤지딘에 폭로된 흰쥐의 간장세포와 방광 상피세포에 형성된 DNA adducts의 $^{32}P-postlabeling$과 GC/MS-SIM에 의한 분석

  • 이진헌;신호상;장미선
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2002년도 춘계 국제 학술대회
    • /
    • pp.49-51
    • /
    • 2002
  • To identify and evaluate the dichlorobenzidine(DCB)-DNA adducts in liver cell and bladder epithelial cells by $^{32}$ P-postlabeling and GC/MS-SIM, we orally exposed the dichlorobenzidine (20mg/kh body wt.,/day)to male sprague-dawley rats for 14 days. Two kinds of DCB-DNA adduct were found at the same site of thin layer chromatogram of $^{32}$ P-postlabeling method in liver cells and bladder epithelial cells. In liver cells, relative adduct labeling(RAL) $\times$ 10$^{12}$ of DCB-DNA adduct A1 were 34.1$\pm$3.71 and 69.9$\pm$5.02, that of adduct A2 were 74.1$\pm$10.1 and 105.1$\pm$10.1 on 10 and 14 days after treatment, respectively. And in bladder epithelia cells, RAL $\times$ 10$^{12}$ of DCB-DNA adduct A1 were 5.92$\pm$1.60 and 15.9$\pm$1.31, that of adduct A2 were 9,81$\pm$2.81 and 22.8$\pm$1.79 on 10 and 14 days after treatment, respectively. DCB metabolites formed DNA adducts were monoacetyl-dichlorobenzidine(acDCB) and diacety1-dichlorobenzidine(di-acDCB), which was identify by gas chromatography/mass spectrometry-scan ionization mode(GC/MS-SIM), along with hydrolysis, extraction and TFA(trifluoroacetyl anhyride) derivatization with DCB-DNA adducts isolated from live cells and bladder epithelial cells. The base peak of acDCB were 252 and 294 m/z, and that of di-acDCB were 252, 294 and 336 m/z. In conclusion, the exposed DCB formed two kinds of DCB-DNA adduct, the proximate materials of that were acDCB and di-acDCB in liver and bladder epithlial cells. And the above GC/MS-SIM method was found the DCB-DNA adducts could be monitoring by gas chromatography.

  • PDF

Prediction accuracy of incisal points in determining occlusal plane of digital complete dentures

  • Kenta Kashiwazaki;Yuriko Komagamine;Sahaprom Namano;Ji-Man Park;Maiko Iwaki;Shunsuke Minakuchi;Manabu, Kanazawa
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권6호
    • /
    • pp.281-289
    • /
    • 2023
  • PURPOSE. This study aimed to predict the positional coordinates of incisor points from the scan data of conventional complete dentures and verify their accuracy. MATERIALS AND METHODS. The standard triangulated language (STL) data of the scanned 100 pairs of complete upper and lower dentures were imported into the computer-aided design software from which the position coordinates of the points corresponding to each landmark of the jaw were obtained. The x, y, and z coordinates of the incisor point (XP, YP, and ZP) were obtained from the maxillary and mandibular landmark coordinates using regression or calculation formulas, and the accuracy was verified to determine the deviation between the measured and predicted coordinate values. YP was obtained in two ways using the hamularincisive-papilla plane (HIP) and facial measurements. Multiple regression analysis was used to predict ZP. The root mean squared error (RMSE) values were used to verify the accuracy of the XP and YP. The RMSE value was obtained after crossvalidation using the remaining 30 cases of denture STL data to verify the accuracy of ZP. RESULTS. The RMSE was 2.22 for predicting XP. When predicting YP, the RMSE of the method using the HIP plane and facial measurements was 3.18 and 0.73, respectively. Cross-validation revealed the RMSE to be 1.53. CONCLUSION. YP and ZP could be predicted from anatomical landmarks of the maxillary and mandibular edentulous jaw, suggesting that YP could be predicted with better accuracy with the addition of the position of the lower border of the upper lip.

콘포컬 레이저 현미경을 이용한 불연속면의 거칠기 측정 연구 (A Study of Roughness Measurement of Rock Discontinuities Using a Confocal Laser Scanning Microscope)

  • Byung Gon Chae;Jae Yong Song;Gyo Cheol Jeong
    • 지질공학
    • /
    • 제12권4호
    • /
    • pp.405-419
    • /
    • 2002
  • 새롭게 개발된 레이저 콘포컬 현미경을 이용해 암석 불연속면의 거칠기를 측정하였다. 레이저의 파장은 488 nm이며, 현미경은 두 개의 galvano-meter scanner mirror를 이용한 광 편광법에 의해 제어된다. 레이저 반사를 통한 자동 초점기능은 관찰대상을 빠르고 정확하게 측정할 수 있다. 이 현미경은 기존의 다른 콘포컬 현미경에 비해 광축방향의 해상도를 크게 개선하였고, 특수 제작한 현미경 스테이지를 이용해 최대 $10{\;}{\times}{\;}10{\;}cm$ 까지 크기의 시료를 측정할 수 있다. 측정간격은 x와 y 방향으로 $2.5{\;}\mu\textrm{m}$씩이며, z방향의 최대 측정해상도는 $10{\;}\mu\textrm{m}$로서, 다른 방범에 비해 훨씬 정확하다. 조립질과 세립질의 입도가 다른 화강암을 대상으로 인장시험(Brazilian test)를 통해 인공절리를 생성시켰고, 생성된 좌우의 절리면에 각각 3개씩의 측선을 설정하였다. 각 측선을 따라 측정한 높이는 1차원은 물론 거칠기의 세밀한 양상을 보여주는 2차원과 3차원의 디지털 이미지로 표현된다. 조립질 화강암의 1차원 단면은 세립질보다 불연속면의 기복이 더 심함을 잘 보여준다. 거칠기를 정량적으로 특성화하고 거칠기를 구성하는 성분 중 가장 큰 영향을 미치는 성분을 파악하기 위해 고속퓨리에 변환 (FFT)를 이용한 스펙트럼 분석을 실시하였다. 스펙트럼 분석결과 저주파 성분이 큰 시효의 경우 거칠기의 기복변화가 심하고 긴 파장을 나타내는 경향이 있음을 구명하였다.

나선형 주사 방법에 의한 고속 NMR 영상화 연구 (High-Speed NMR Imaging by Spiral -Scan Echo Planar Method)

  • 안창범;류충렬;김재호;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1985년도 춘계학술대회
    • /
    • pp.22-25
    • /
    • 1985
  • 본고에서, "나선형 주사 방법에 의한 고속 NMR 영상화" 방법을 제안하고 그에 따른 실험 결과를 보였다. 이것은 2차원 FID 영역을 나선형 궤적으로 스캐닝하며 데이타를 받을 수 있도록 경사 자계 파형 (gradient pulse)을 가하여 빠른 시간에 (수십 msec - 수초)내에 영상 정보를 얻어낸 후, 재구성 알고리즘을 씀으로써 영상을 얻어내는 방법이다. 이 방법의 장점은 첫째로 $T_2$ 감쇄에 의한 PSF (Point Spread Function)가 윈형 대칭으로 주어지므로 영상화 했을때 물체의 구조 식별이 기존의 EPI (Echo Planar Imaging) 방법에 비해서 선명하며, 둘째로 나선형 궤적을 구현하기 의한 경사 자계 파형에서 불연속 점을 없앰과 동시에 파형의 세기가 점차로 증가하는 형태이므로, 기존의, 파형 왜곡에 의해 영상에 미치는 영향을 최소화 할 수가 있으며, 세째로 나선형 스캔을 사이 사이에 끼워 넣는 방법을 씀으로써 해상도를 향상시킬 수가 있다.

  • PDF

Linear and Nonlinear Optical Properties of Vanadium Pentoxide Films Prepared by Pulsed-Laser Deposition

  • Cui, Liqi;Wang, Ruiteng;Wang, Weitian
    • 한국재료학회지
    • /
    • 제31권7호
    • /
    • pp.382-385
    • /
    • 2021
  • Well-crystallized vanadium pentoxide V2O5 thin films are fabricated on MgO single crystal substrates by using pulsed-laser deposition technique. The linear optical transmission spectra are measured and found to be in a wavelength range from 300 to 800 nm; the data are used to determine the linear refractive index of the V2O5 films. The value of linear refractive index decreases with increasing wavelength, and the relationship can be well explained by Wemple's theory. The third-order nonlinear optical properties of the films are determined by a single beam z-scan method at a wavelength of 532 nm. The results show that the prepared V2O5 films exhibit a fast third-order nonlinear optical response with nonlinear absorption coefficient and nonlinear refractive index of 2.13 × 10-10 m/W and 2.07 × 10-15 cm2/kW, respectively. The real and imaginary parts of the nonlinear susceptibility are determined to be 3.03 × 10-11 esu and 1.12 × 10-11 esu, respectively. The enhancement of the nonlinear optical properties is discussed.

전신 뼈 검사 환자의 불안감 해소를 위한 가상현실 장비의 유용성 평가 (Evaluation of the Usefulness of Virtual Reality Equipment for Relieving Patients' Anxiety during Whole-Body Bone Scan)

  • 김혜린;김정열;이승재;백송이;김진구;김가윤;남궁혁;강천구;김재삼
    • 핵의학기술
    • /
    • 제26권1호
    • /
    • pp.27-32
    • /
    • 2022
  • 전신 뼈 검사를 시행할 경우 검출기와 밀접한 거리로 인해 심리적 어려움을 겪고 있는 환자들이 많다. 최근 의료분야에서 가상현실(Virtual reality, VR) 장비를 사용하여 주의분산법(distraction method)을 통해 집중력이 약한 소아 환자 또는 중증 치료를 받는 환자에게 진통경감 효과를 줄 수 있다는 보고가 있다. 이에 본 논문은 핵의학 검사 시 환자들에게 심리적 안정을 주기 위해 VR 장비를 사용하였고, 이를 임상에서 활용할 수 있는지 평가해보고자 한다. VR 장비로는 ALLIP Z6 VR (ALLIP, Korea)을 사용하여 휴대전화에 연결한 후 실험을 진행하였다. 대상자는 2021년 9월 1일부터 2021년 9월 30일까지 전신 뼈 검사를 시행한 환자 30명으로 하였다. 99mTc-HDP를 정맥주사한 후 3시간~6시간 뒤에 VR 장비를 착용하고 전신영상을 얻었다. 검사 후 설문조사를 실시하였고 검사에 대한 심리적 불안도와 VR 장비에 대한 만족도는 리커트 척도 5점을 이용하였다. 설문조사에 관한 가설검증 및 신뢰도는 SPSS Statistics 25 (IBM, Corp., Armonk, NY, USA)를 통해 분석하였다. 기존 전신 뼈 검사에 대한 불안감은 3.03±1.53인 반면 VR 장비 착용 후의 불안감은 2.0±1.21으로 불안도가 34%로 감소 한 것으로 나타났다. VR 장비에 대한 환자의 집중도가 검사에 대한 불안감에 미치는 영향력을 회귀분석 했을 때 B값은 0.750 (p<0.01), t값은 6.181 (p<0.01)으로 VR 장비에 집중할수록 검사 시 불안도가 감소하고 75%의 영향력이 있음을 나타냈다. 또한 전체적인 VR 장비에 대한 만족도는 3.76±1.28이었고 재사용의사율은 66%였다. 설문지의 신뢰도계수 Cronbach α값은 0.901로 나타났다. VR 장비를 사용할 경우 환자들의 주의가 분산되면서 불안감이 감소되고 심리적으로 안정되는 효과가 나타났다. 향후 VR 장비 기술이 발전됨에 따라 장비의 소형화가 가능해지고 VR 콘텐츠영상의 해상력이 증가하는 등 보다 사실적으로 환자에게 안정감이 제공된다면 임상에서도 다양하게 활용될 수 있을 것이라 사료된다.