• Title/Summary/Keyword: Z-resolution

Search Result 206, Processing Time 0.026 seconds

True Three-Dimensional Cone-Beam Reconstruction (TTCR) Algorithm - Transform Method from Parallel-beam (TTR) Algorithm - (원추형 주사 방식의 3차원 영상 재구성(TTCR) 알고리즘 - 평행주사 방식(TTR) 알고리즘의 좌표변환 -)

  • Lee, S.Z.;Ra, J.B.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1989 no.05
    • /
    • pp.55-59
    • /
    • 1989
  • A true three-dimensional cone-beam reconstruction (TTCR) algorithm for the complete sphere geometry is derived, which is applicable to the direct volume image reconstruction from 2-D cone-beam projections. The algorithm is based on the modified filtered backprojection technique which uses a set of 2-D space-invariant filters and is derived from the previously developed parallel-beam true three-dimensional reconstruction(TTR) algorithm. The proposed algorithm proved to be superior in spatial resolution compared with the parallel-beam TTR algorithm.

  • PDF

A-HILBERT SCHEMES FOR ${\frac{1}{r}}(1^{n-1},\;a)$

  • Jung, Seung-Jo
    • The Pure and Applied Mathematics
    • /
    • v.29 no.1
    • /
    • pp.59-68
    • /
    • 2022
  • For a finite group G ⊂ GL(n, ℂ), the G-Hilbert scheme is a fine moduli space of G-clusters, which are 0-dimensional G-invariant subschemes Z with H0(𝒪Z ) isomorphic to ℂ[G]. In many cases, the G-Hilbert scheme provides a good resolution of the quotient singularity ℂn/G, but in general it can be very singular. In this note, we prove that for a cyclic group A ⊂ GL(n, ℂ) of type ${\frac{1}{r}}$(1, …, 1, a) with r coprime to a, A-Hilbert Scheme is smooth and irreducible.

Design and Construction of Cylindrical Multi-Loop Z-gradient Coil for Linearity Improvement in MRI (핵자기공명영상에서 선형성의 증강을 위한 원통형 Multi-Loop Z-경사자기장 코일의 설계와 제작)

  • 이동훈;백승태;김송희
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.6
    • /
    • pp.583-589
    • /
    • 2000
  • 본 논문에서는 핵자기공명영상의 고해상도를 이루고, 영상의 신뢰성을 높이기 위해서 선형성이 증가된 경사자기장 코일의 설계와 제작에 목적을 두었다. Maxwell pair를 이용하여 Z-경사자계의 선형성을 증강시키기 위해 코일의 기하학적인 형태의 이론적인 계산과 몇 가지 형태의 코일로부터 예상되는 자기장 및 경사자기장의 분포를 구현했다. 즉, 코일 축 방향의 자기장을 구면좌표계에서 전개하는 방법으로 Maxwell pair의 크기와 위치를 계산하고, 유한요소법을 이용하여 자기장 및 경사자기장의 2차원 분포를 그렸다. 더불어 이론적인 계산 결과와 함께 자기장의 2차원 분포를 토대로 실제 경사자기장 코일을 제작하였고 이를 0.15 Τ 핵자기공명영상기에 적용하여, 영상을 획득하였다. 기존의 방법에 따른 Maxwell pair 형태를 이용한 경우에 코일지름의 40% DSV(diameter spherical volume)내에서 DSV의 5% 이내의 뒤틀림(distortion)을 갖는 선형성이 유지되었고, 새롭게 시도된 방법에 의한 경사자기장 코일의 경우는 코일지름의 70% DSV 내에서 DSV의 5% 이내의 뒤틀림을 갖는 선형성을 유지하였으며, 설계 제작된 경사자기장 코일과 RF-코일을 이용하여 이를 확인하였다. 본 연구에서 제작된 경사자기장 코일의 선형성은 Maxwell pair 코일보다 향상된 결과를 보았으며, 본 논문에서 제시하는 방법은 자기공명영상의 해상도 향상에 기여할 것으로 판단된다.

  • PDF

A study of Satellite Image-Based Stereoscopic Vision System (위성영상 관련 입체도시시스템 개발에 관한 연구)

  • 김감래;김훈정;김주용
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.239-243
    • /
    • 2004
  • It does not exist almost that Most satellite image has both high spectral and spatial resolution. In order to apply the satellite image for to be actual, we need numerical and analytical technique development to improve the resolution. Specially in the function of solid illustration, we represent the solid image through the image generation to solid screen. The main function includes magnification, reduction, screen center movement, Panning, territory magnification. The method to process the image includes histogram and contrast modulation. Afterwards, we will develop the function includes 3-dimension cursor to control the elevation position and calculate the ground coordination automatically. There is the layer control includes the representation and the edition of 3D vector, extraction the Z value by On the Ground and digital elevation.

  • PDF

The analysis of sputtering characteristics using Focused Ion Beam according to Focal Length (FIB 가공 공정 특성 분석)

  • Choi B.Y.;Choi W.C.;Kang E.G.;Hong W.P;Lee S.W.;Choi H.Z.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1518-1521
    • /
    • 2005
  • The application of focused ion beam (FIB) technology in micro/nano machining has become increasingly popular. Its usage in micro/nano machining has advantages over contemporary photolithography or other micro/nano machining technologies such as small feature resolution, the ability to process without masks and being accommodating for a variety of materials and geometries This paper focus to apply the sputtering technology accumulated by experiments to 3d structure fabrication with high resolution. Therefore some verifications and discussions of the characteristics of FIB sputtering results according to focal length were described in this paper. And we suggested the definition of rectangular pattern profile and made the verifications of sputtering results based on definition of it.

  • PDF

A high-resolution mapping of wind energy potentials for Mauritius using Computational Fluid Dynamics (CFD)

  • Dhunny, Asma Z.;Lollchund, Michel R.;Rughooputh, Soonil D.D.V.
    • Wind and Structures
    • /
    • v.20 no.4
    • /
    • pp.565-578
    • /
    • 2015
  • A wind energy assessment is an integrated analysis of the potential of wind energy resources of a particular area. In this work, the wind energy potentials for Mauritius have been assessed using a Computational Fluid Dynamics (CFD) model. The approach employed in this work aims to enhance the assessment of wind energy potentials for the siting of large-scale wind farms in the island. Validation of the model is done by comparing simulated wind speed data to experimental ones measured at specific locations over the island. The local wind velocity resulting from the CFD simulations are used to compute the weighted-sum power density including annual directional inflow variations determined by wind roses. The model is used to generate contour maps of velocity and power, for Mauritius at a resolution of 500 m.

Study on Slice Sensitivity Profile and Reconstruction Resolution on Helical CT System (Helical CT 시스템에 있어 Slice Sensitivity Profile과 Reconstruction Resolution에 관한 연구)

  • Yoon, Han-Sik
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.15-20
    • /
    • 1997
  • Unlike conventional CT scan, the helical CT scan uses continuous rotating CT equipment with a slip ring to move the patient's coach at a constant speed while continuously scanning. Slice sensitivity profiles in the Z-position(SSPz) using the conventional X-ray CT have a shape similiar to a rectangular wave, which slightly spreads out into plains below the mountain. However, in the helical CT, with an expansion of the base, the rectangular shape collapses and a mouatain-like shape can be seen. We need to investigate the fellowing factors in helical CT scanning;the ability to scan along the axis of the body, effective slice width, slice shape and the precision of coach velocity, Helical scanning with sprial X-ray track is different from the conventional scanning in terms of the principle of image reconstruction performed. We believe that the problems in helical scanning can be solved by understanding new the special parameters such as the bed moving speed and the interval of image reconstruction.

  • PDF

Wavelength Readout of A Fiber Laser Using Time Delayed Quadrature Sampling (시간지연샘플링을 이용한 광섬유레이저의 파장변화검출)

  • 김종섭;송민호
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.3
    • /
    • pp.31-38
    • /
    • 2004
  • The wavelength variation of a scanned fiber laser is analyzed using quadrature sampling technique. By time delayed sampling of a phase modulated Mach-Zender interferometer, the wavelength information can be precisely determined regardless of the nonlinearity in the Fabry-Perot wavelength filter which scanned the fiber laser. A wavelength readout resolution of ~20 pm was obtained at 2 KHz M-Z modulation frequency, and it was shown that the resolution could be improved in case of using an electro-optic phase modulator.

Analytical Characteristics and Applications of Laser Ionization Mass Spectrometry

  • 임훙선;윤하섭;김성규
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.1
    • /
    • pp.32-37
    • /
    • 1997
  • We have built a laser ionization mass spectrometer (LIMS) for chemical composition analysis of solid samples, which employs an Nd:YAG laser and a time-of-flight mass analyzer. In this spectrometer, the maximum mass we identified clearly is higher than 2000 amu. A mass resolution of 230 has been achieved at m/z 208 (Pb element) in the linear TOFMS and can be even improved up to 1550 by employing a reflectron. The detection limit is determined to be on the order of ppm for Fe and In. The depth resolution is found to be about 20Å/spectrum with a laser power of 0.5 J/cm2. We also report a preliminary application of the LIMS to identifying impurities resident in several solid samples.

Characterization of Molecular Composition of Bacterial Melanin Isolated from Streptomyces glaucescens Using Ultra-High-Resolution FT-ICR Mass Spectrometry

  • Choi, Mira;Choi, A Young;Ahn, Soo-Yeon;Choi, Kwon-Young;Jang, Kyoung-Soon
    • Mass Spectrometry Letters
    • /
    • v.9 no.3
    • /
    • pp.81-85
    • /
    • 2018
  • In this study, the chemical composition of bacterial melanin isolated from the Streptomyces glaucescens strain was elucidated by ultra-high-resolution Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry. Ultra-high-resolution mass profiles of the microbial melanin product were acquired using a 15 Tesla FT-ICR mass spectrometer in positive and negative ion modes via electrospray ionization to obtain more complete descriptions of the molecular compositions of melanin-derived organic constituents. A mass resolving power of 500,000 (at m/z 400) was achieved for all spectra while collecting 400 scans per sample with a 4 M transient. The results of this analysis revealed that the melanin pigment isolated from S. glaucescens predominantly exhibits CHON and CHO species, which belong to the proteins class of compounds, with the mean C/O and C/N ratios of 4.3 and 13.1, thus suggesting that the melanin could be eumelanin. This analytical approach could be utilized to investigate the molecular compositions of a variety of natural or synthetic melanins. The compositional features of melanins are important for understanding their formation mechanisms and physico-chemical properties.