• 제목/요약/키워드: Younggwang Nuclear Power Plant

검색결과 15건 처리시간 0.024초

영광 원자력 발전소 주변 환경 방사능 측정에 관한 연구 (The study on Measuring of Environmental Radioactivity in the Vicinity of Yonggwang Nuclear Power Plant)

  • 박종섭
    • 자원환경지질
    • /
    • 제32권3호
    • /
    • pp.273-280
    • /
    • 1999
  • In order to protect inhabitans' health and to collect data for prediction of the effcts from accidental emission of rasioactive materials from nuclear power plant, exposed dose rate be monitored within the limit dose rate. This research was carried out to investigate the accumulation of environmental radioactivity around Younggwang Nuclear Power Plant, and to infer and in infer and assay the additional exposed dose rate of inhabitants in Younggwang site from the operation of nuclear plant operation. External radiation dose rate, radiation environmental samples, and exposed dose rate of inhabitants in Younggwang site were investigated for estimaing environment activity in the vicinity of the nuclear power plant area. For the external radiation dose rate, the result showed that range of normal variation was found and any artificial radioisotope was not deteted in the analysis of environmental samples. Exposed dose rate of inhabitants was lower than 0.4% of the limit value of ICRP and it may be concluded that there was no effect on inhabitants and environment from the operation of nuclear power plant.

  • PDF

발전소 시뮬레이터의 다이나믹 모델과 디스플레이 모델간 데이터전송 (Data Transporting between Dynamic Model and Display Model of Power Plant Simulator)

  • 김동욱
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 1998년도 The Korea Society for Simulation 98 춘계학술대회 논문집
    • /
    • pp.86-90
    • /
    • 1998
  • The safety and reliability of nuclear power plant operations relies heavily on the plant operators ability to respond to various emergency situations. It has become standard industry practice to utilize simulators to improve the safety and reliability of nuclear power plants operations. The simulators built for Younggwang#3,4, which is the basic model of the Korean Nuclear Power Plant design, has been developed precisely for this purpose. Dynamic Model and Display Model are developed under US3(UNIX Simulation Software Support System) environment in simulator for Younggwang#3,4. Since these two models are developed under each own operating system, it is necessary to develop a method for transporting data between these two systems. This paper descirves communication environment between Dynamic Model and Display Model, and addresses a file generation method for the Display Model, which will be necessary for designing MMI of MCR(Main Control Room) in the furture.

  • PDF

가압경수로 원자력 발전소의 전범위 복제형 시뮬레이터 개발 (The Development of Full-Scope Replica Type Simulator for PWR Nuclear Power Plants)

  • 이중근
    • 한국시뮬레이션학회논문지
    • /
    • 제6권1호
    • /
    • pp.85-96
    • /
    • 1997
  • Designing and constructing a proper simulator for real power plants requires extensive research in human engineering and computer science and integration of different fields of technologies such as system analysis, operational knowledge for nuclear plant, etc. A full scope replica type simulator for nuclear power plant is developed. The simulator has the same feature and operational functions as one in the main control room (MCR) of a reference power plant. The simulator provides the necessary training to recover or reduce damages from accidents that usually are unpredictable. This paper describes the configurations and characteristics for the simulator that is developed for Younggwang Nuclear Power Plant #3,4 which is the basic model of the Korean Nuclear Power Plant. The paper also describes technical aspects of Auto Code Generator that is used for developing the simulator. The successful development of the simulator will contribute to improve safety in operation of nuclear power plants.

  • PDF

A Combined Procedure of RSM and LHS for Uncertainty Analyses of CsI Release Fraction Under a Hypothetical Severe Accident Sequence of Station Blackout at Younggwang Nuclear Power Plant Using MAAP3.0B Code

  • Han, Seok-Jung;Tak, Nam-Il;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제28권6호
    • /
    • pp.507-521
    • /
    • 1996
  • Quantification of uncertainties in the source term estimations by a large computer code, such as MELCOR and MAAP, is an essential process of the current Probabilistic safety assessment. The main objective of the present study is to investigate the applicability of a combined procedure of the response surface method (RSM) based on input determined from a statistical design and the Latin hypercube sampling (LHS) technique for the uncertainty analysis of CsI release fractions under a Hypothetical severe accident sequence of a station blackout at Younggwang nuclear power plant using MAAP3. OB code as a benchmark problem. On the basis of the results obtained in the present work, the RSM is recommended to be used as a principal tool for an overall uncertainty analysis in source term quantifications, while using the LHS in the calculations of standardized regression coefficients (SRC) and standardized rank regression coefficient (SRRC) to determine the subset of the most important input parameters in the final screening step and to check the cumulative distribution functions obtained by RSM. Verification of the response surface model for its sufficient accuracy is a prerequisite for the reliability of the final results that can be obtained by the combined procedure proposed in the present work.

  • PDF

발전소 시뮬레이터 기술동향 및 국내 기술자립 계획 (The Status of Power Plant Simulation Technology and KEPCO's Plan for Self-Reliance of the Technology)

  • 신영철;이용관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.525-528
    • /
    • 1993
  • KEPCO Research Center is carrying out a simulator(full scope replica type) development project for two nuclear power plants(Kori-2, Younggwang-3,4) and one fossil power plant(Poryong-3,4). In this project, we aim not only the installation of high performance simulators at the power plant sites but also the realization of self reliance of power plant simulation technology in Korea. In the course of preparing procurement specification for the 3 simulators, the present status of power plant simulation technology has been surveyed and is presented in this paper. The fidelity of simulation and the automation of simulation model production has been greatly improved due to the ever increasing computing power of today's workstations. The need and importance of the application of high fidelity simulators to the operator training is refocused since the accident at TMI Nuclear Power Plant, U.S.A.

  • PDF

Development of CPC/COLSS Simulation Model for YGN#3,4 Simulator

  • Kim, Dong-Wook
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.251-256
    • /
    • 1997
  • The safety and reliablity of nuclear power plant operations relies heavily on the plant operators ability to respond to various emergency situations. It has become standard industry practice to utilize simulators to improve the safety and reliability of nuclear power plants operations. The simulators built for Younggwang#3("YGN#3"), which is based on the Korean Standard Nuclear Power Plant ("KSNPP")design, has been developed precisely for this purpose. The YGN#3 simulator is the first simulator in Korea to be developed locally and is now operational on site. A particular attention was placed on the development of CPC/COLLS safety system which is unique to the YGN#3. The effort to develop CPC/COLLS simulation model has been successful and plans exist for applying this model to simulator projects in the future.jects in the future.

  • PDF

Axial Shape Index Calculation for the 3-Level Excore Detector

  • Kim, Han-Gon;Kim, Yong-Hee;Kim, Byung-Sop;Lee, Sang-Hee;Cho, Sung-Jae
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.97-102
    • /
    • 1997
  • A new method based on the alternating conditional expectation (ACE) algorithm is developed to calculate axial shape index (ASI) for the 3-level excore detector. The ACE algorithm, a type of non-parametric regression algorithms, yields an optimal relationship between a dependent variable and multiple independent variables. In this study, the simple correlation between ASI and excore detector signals is developed using the Younggwang nuclear power plant unit 3 (YGN-3) data without any preprocessing on the relationships between independent variables and dependent variable. The numerical results show that simple correlations exist between the three excore signals and ASI of the core. The accuracy of the new method is much better than those of the current CPC and COLSS algorithms.

  • PDF

복잡한 지형상에서 실시간 피폭해석 시스템 검증 (Validation of a Real-Time Dose Assessment System over Complex Terrain)

  • 서경석;김은한;황원태;최영길;한문희;정성태
    • Journal of Radiation Protection and Research
    • /
    • 제24권1호
    • /
    • pp.31-38
    • /
    • 1999
  • 원자력시설의 사고시 신속한 방재대책 결정지원 체계를 수립하기 위하여 실시간 방사선 피폭해석 시스템(FADAS : Following Accident Dose Assessment System)을 개발하였다. 개발된 시스템의 정확도 향상 및 국내 부지 특성자료의 모수화를 위하여 복잡한 지형상에 위치한 영광 원자력발전소 주변에서 야외 확산실험이 수행되었다. 확산실험을 통하여 얻어진 바람의 평균 및 난류장 성분은 부지 특성별 변수로 실시간 방사선 피폭해석 시스템에 반영되었다. 확산모형의 계산결과와 실험을 통하여 관측된 추적자 가스의 농도분포를 상호 비교한 바 어느 정도 일치하고 있었다. 개발된 시스템은 현재 구축중인 국가 규모의 비상대응지원체제에 기본 모듈로서 활용 중에 있으며 지속적인 확산실험을 통하여 부지 특성 변수들이 반영된 확산모형을 개선할 예정이다.

  • PDF

수중로봇 시스템의 개발과 원자로 압력용기 육안검사에의 적용 (The Development of Underwater Robotic System and Its application to Visual Inspection of Nuclear Reactor Internals)

  • 조병학;변승현;신창훈;양장범
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1327-1330
    • /
    • 2004
  • An underwater robotic system has been developed and applied to visual inspection of reactor vessel internals. The Korea Electric Power Robot for Visual Test (KeproVt) consists of an underwater robot, a vision processor-based measuring unit, a master control station and a servo control station. The robot guided by the control station with the measuring unit can be controlled to have any motion at any position in the reactor vessel with $\pm$1 cm positioning and $\pm$2 degrees heading accuracies with enough precision to inspect reactor internals. A simple and fast installation process is emphasized in the developed system. The developed robotic system was successfully deployed at the Younggwang Nuclear Unit 1 for the visual inspection of reactor internals.

  • PDF

영광 3,4호기 Foxboro 제어시스템 모델링 및 시뮬레이션 (Modeling and simulation of foxboro control system for YGN#3,4 power plant)

  • 김동욱;이용관;유한성
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.179-182
    • /
    • 1997
  • In a training simulator for power plant, operator's action in the MCR(Main Control Room) are given to plant process and computer system model as an inputs, and the same response as in real power plant is provided in real time. Inter-process communication and synchronization are especially important among various inputs. In the plant simulator, to simulate the digital control system such as FOXBORO SPEC-200 Micro control system, modification and adaptation of control card(CCC) and its continuous display station(CDS) is necessary. This paper describes the modeling and simulation of FOXBORO SPEC-200 Micro control system applied to Younggwang nuclear power plant unit #3 & 4, and its integration process to the full-scope replica type training simulator. In a simulator, display station like CDS of FOXBORO SPEC-200 Micro control system is classified as ITI(Intelligent Type Instrument), which has a micro processor inside to process information and the corresponding alphanumeric display, and the stimulation of ITI limits the important functions in a training simulator such as backtrack, replay, freeze and IC reset. Therefore, to achieve the better performance of the simulator, modification of CDS and special firmware is developed to simulate the FOXBORO SPEC-200 Micro control system. Each control function inside control card is modeled and simulated in generic approach to accept the plant data and control parameter conveniently, and debugging algorithms are applied for massive coding developed in short period.

  • PDF