• Title/Summary/Keyword: Yi Jin sang

Search Result 420, Processing Time 0.029 seconds

Determination of Eccentric Axis for Pump Control Valve Using the Characteristic Function (특성함수를 이용한 펌프 제어 밸브의 편심축 결정)

  • Shin, Myung-Seob;Yi, Sang-Il;Park, Gyung-Jin;Yoon, Joon-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.3
    • /
    • pp.43-49
    • /
    • 2008
  • The pump control valve is a butterfly valve that has an eccentric rotating axis. It is not only used as a butterfly valve to control the flow rate or pressure, but also as a check valve to prevent backward flow. A new design method of eccentric rotating axis is proposed to design the valve. The height of the rotating axis is determined through flow field analysis. A general purpose of computational fluid dynamics software system, Fluent is used to simulate the fluid flow. Flow field analysis is performed for various heights of the rotating axis and different opening angles of the valve. A characteristic function is defined for estimating the flow characteristics based on the results of flow field analysis. The characteristic function is defined in order to determine the height of the rotating axis. An optimization problem with a characteristic function is formulated to determine the amount of eccentricity. The height of the Totaling axis of the valve is determined through solving the optimization problem.

Identification of Irradiated Granule-Type Ramen Soup Powder by Pulsed Photostimulated Luminescence and Thermoluminescence during Storage

  • Yi, Sang-Duk;Yang, Jae-Seung;Kim, Dong-Woo;Shin, Doo-Ho;Jo, Gab-Yeon;Chang, Kyu-Seob;Oh, Man-Jin
    • Preventive Nutrition and Food Science
    • /
    • v.8 no.1
    • /
    • pp.79-84
    • /
    • 2003
  • This study was carried out to establish a method for determining if granule-type Ramen soup powder has been irradiated. Thermoluminescence (TL) and pulled photostimulated luminescence (PPSL) were used as the detection methods through observed changes of TL and PPSL intensities after storage under differing conditions. PPSL intensities increased with increases in irradiation doses. The threshold level of PPSL was below 412$\pm$58 photon counts regardless of storage conditions (room and darkroom) after 10 months. TL intensities also increased with increasing irradiation doses. The coefficients ($R^2$) of PPSL (0.74~0.94) and TL intensities (0.92~0.58) were very highly correlated with irradiation dose. The PPSL and TL intensities were decreased after 10 months of storage. These results indicate that discrimination of irradiated from non-irradiated granule-type Ramen soup powder is possible using TL and PPSL methods despite the decrease in intensities of TL and PPSL with increasing storage times.

Deformation of Amorphous GeSe2 Film under Uniaxial Pressure Applied at Elevated Temperatures

  • Jin, Byeong Kyou;Lee, Jun Ho;Yi, Jeong Han;Lee, Woo Hyung;Shin, Sang Yeol;Choi, Yong Gyu
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.2
    • /
    • pp.108-113
    • /
    • 2015
  • In an effort to evaluate the practicability of an imprinting technique for amorphous chalcogenide film in Ge-based compositions, we investigate the deformation behavior of the surface of amorphous $GeSe_2$ film deposited via a thermal evaporation route according to varying static loads applied at elevated temperatures. We observe that, under these static loading conditions, crystallization tends to occur on its surface relatively more easily than in As-based $As_2Se_3$ films. As for the present $GeSe_2$ film, higher processing temperatures are required in order to make its surface reflect the given stamp patterns well; however, in this case, its surface becomes partially crystallized in the monoclinic $GeSe_2$ phase. The increased vulnerability of this amorphous $GeSe_2$ film toward surface crystallization under static loading, when compared with the $As_2Se_3$ counterpart, is explained in terms of the topological aspects of its amorphous structure.

Study on the Transfer Functions for Detecting Windings Displacement of Power Transformers with Impulse Method

  • Shon, Chae-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.876-883
    • /
    • 2012
  • The paper investigates three types of transfer function methods for detecting displacements of winding in a model transformer. To acquire these transfer functions, the measuring method of input voltage, current and its response is used in impulse method. The applied impulse voltages had three rising times, which were short rising time (less than 0.6 ${\mu}s$), medium rising time (about 0.8 ${\mu}s$) and long rising time (about 1 ${\mu}s$) in front waves. Every 10 measurements of voltage and current waves were averaged from 50 measurements of voltage and current waves. These transfer functions were tested in normal, 24mm elevated and 48mm elevated windings conditions and were analyzed with correlation coefficients and spectrum deviations. In the analysis, the results depend on the types of transfer functions and the rising times of input voltages.

Development of Nano-Stereolithography Process for Precise Fabrication of Three-Dimensional Micro-Devices (3차원 마이크로 디바이스 개발을 위한 나노 스테레오리소그래피 공정 개발에 관한 연구)

  • Park Sang-Hu;Lim Tae Woo;Yang Dong-Yol;Yi Shin Wook;Kong Hong-Jin;Lee Kwang-Sup
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.1
    • /
    • pp.45-49
    • /
    • 2006
  • A nano-stereolithography (NSL) process has been developed for the fabrication of three-dimensional (3D) micro-devices with high spatital resolution of approximately 100 nm. In the NSL process, a complicated 3D structure can be created by stacking layer-by-layer, so it does not require any sacrificial layer or any supporting structure. A laminated layer was fabricated by means of solidifying liquid-state monomers using two-photon absorption (TPA) which was induced by a femtosecond laser. When the fabrication of a 3D stacked structure was finished, unsolidified liquid resins were rinsed by ethanol to develop the fabricated structures; then, the polymerized structure was only left on the glass substrate. Through this work, several 3D microstructures such as a micro-channel, shell structures, and photonic crystals were fabricated to evaluate the possibility of the developed system.

Setup of standard PD calibrator and its uncertainties

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.677-683
    • /
    • 2011
  • The present paper describes the setup of standard partial discharge calibrator for measuring partial discharge and estimating uncertainties. The standard PD calibrator was designed and set up, consisting of a digital pulse generator, capacitor modules, and a digital oscilloscope controlled by software developed in the laboratory. Using this software, averages of charges and rising times and their standard deviations in the measured pulses can also be calculated. The standard PD calibrator generates five types of pulses: single, double, random, oscillating, and long-rising. The coefficient sensitivities to estimate the uncertainties of pulses were extracted in the model circuit of the standard PD calibrator. The uncertainties of charges and rising times in pulses of the standard PD calibrator were estimated with single pulses. These values were 0.3%-1.4% in charges and 1.9%-7.0% in rising time; however, these values are lower than the limit values in IEC 60270.

In vitro and in vivo Application of PLGA Nanofiber for Artificial Blood Vessel

  • Kim, Mi-Jin;Kim, Ji-Heung;Yi, Gi-Jong;Lim, Sang-Hyun;Hong, You-Sun;Chung, Dong-June
    • Macromolecular Research
    • /
    • v.16 no.4
    • /
    • pp.345-352
    • /
    • 2008
  • Poly(lactic-co-glycolic acid) (PLGA) tubes (5 mm in diameter) were fabricated using an electro spinning method and used as a scaffold for artificial blood vessels through the hybridization of smooth muscle cells (SMCs) and endothelial cells (ECs) differentiated from canine bone marrow under previously reported conditions. The potential clinical applications of these artificial blood vessels were investigated using a canine model. From the results, the tubular-type PLGA scaffolds for artificial blood vessels showed good mechanical strength, and the dual-layered blood vessels showed acceptable hybridization behavior with ECs and SMCs. The artificial blood vessels were implanted and substituted for an artery in an adult dog over a 3-week period. The hybridized blood vessels showed neointimal formation with good patency. However, the control vessel (unhybridized vessel) was occluded during the early stages of implantation. These results suggest a shortcut for the development of small diameter, tubular-type, nanofiber blood vessels using a biodegradable material (PLGA).

Isolation and Characterization of Rice OsHRL Gene Related to Bacterial Blight Resistance

  • Park, Sang-Ryeol;Moon, Seok-Jun;Shin, Dong-Jin;Kim, Min-Gab;Hwang, Duk-Ju;Bae, Shin-Chul;Kim, Jeong-Gu;Yi, Bu-Young;Byun, Myung-Ok
    • The Plant Pathology Journal
    • /
    • v.26 no.4
    • /
    • pp.417-420
    • /
    • 2010
  • The expression of HR-like lesion inducing gene of Oryza sativa (OsHRL) was slightly increased by Xanthomonas oryzae pv. oryzae (Xoo) infection. Transgenic rice plants over-expressing OsHRL gene were challenged with Xoo and the development of disease symptoms were examined to investigate the effect of OsHRL gene expression on plant defense responses. The over-expression of OsHRL increased disease resistance against Xoo compared with wild type plants.

Surgical endodontic management of infected lateral canals of maxillary incisors

  • Jang, Ji-Hyun;Lee, Jung-Min;Yi, Jin-Kyu;Choi, Sung-Baik;Park, Sang-Hyuk
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.1
    • /
    • pp.79-84
    • /
    • 2015
  • This case report presents surgical endodontic management outcomes of maxillary incisors that were infected via the lateral canals. Two cases are presented in which endodontically-treated maxillary central incisors had sustained lateral canal infections. A surgical endodontic treatment was performed on both teeth. Flap elevation revealed vertical bone destruction along the root surface and infected lateral canals, and microscopy revealed that the lateral canals were the origin of the lesions. After the infected lateral canals were surgically managed, both teeth were asymptomatic and labial fistulas were resolved. There were no clinical or radiographic signs of surgical endodontic management failure at follow-up visits. This case report highlights the clinical significance and surgical endodontic management of infected lateral canal of maxillary incisor. It is important to be aware of root canal anatomy variability in maxillary incisors. Maxillary central incisors infected via the lateral canal can be successfully managed by surgical endodontic treatment.

Nursing Salary Guideline for Korean Hospitals (일반간호사의 임금격차 현황과 표준임금 가이드라인 개발)

  • Kim, Jin Hyun;Ha, Sang Keun;Park, Young Woo;Kim, Yeon Hee;Yi, Sun Mi;Kwon, Hyun Jeong
    • Journal of Korean Clinical Nursing Research
    • /
    • v.26 no.1
    • /
    • pp.75-85
    • /
    • 2020
  • Purpose: The purpose of this study is to develop a nursing salary guideline for Korean hospitals. Methods: Literature review and a mobile survey were conducted regarding staff nurses' salary. Regression analysis and simulation model were applied to develop the nurses' salary guideline. Results: The United Kingdom, Australia, and Germany have standard salary guidelines which demonstrated the standard salary of nurses. These were determined mainly by nursing experience and expertise. The results of the mobile survey indicated that the maximum to minimum ratio of the salary was as high as 4.5 among staff nurses working in Korean hospitals. Two models (exponential and linear) for a standard nursing salary guideline were developed and the simulation results demonstrated an improved salary structure for staff nurses. Conclusion: This developed salary guideline for staff nurses is recommended to be applied in Korean hospitals which provide total nursing care services.