Fabrication of Porous SiC Ceramics by Partial Sintering and their Properties (부분소결공정에 의한 다공질 탄화규소 세라믹스의 제조 및 특성)

  • 김신한;김영욱;윤중열;김해두
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.7
    • /
    • pp.541-547
    • /
    • 2004
  • Addition of large particles restrains densification by small particles in mixed particle systems. In the present study, large SiC whiskers or particles were introduced into small particles for restraining densification and the mixtures were sintered using yttrium aluminum garnet (Y$_3$A1$\sub$5/O$\sub$12/, YAG) as a sintering additive. By controlling the content of large SiC whiskers or particles and the applied pressure during sintering, porous SiC ceramics, with a porosity ranging from 0.3% to 39%, were fabricated. Porosity increased with increasing the content of restraining materials. SiC whiskers were more effective than large SiC partcles for restraining densification. Permeability of the porous SiC ceramics increased with increasing the porosity. Flexural strength decreased with increasing porosity. A noticeable increase in strain to failure was observed in the porous ceramics with a porosity ranging from 18% to 39%.

$KTiOPO_4 (KTP)$ Single Crystal Growth by TSSG Technique (TSSG법에 의한 $KTiOPO_4 (KTP)$ 단결정 육성)

  • 김정환;강진기
    • Korean Journal of Crystallography
    • /
    • v.3 no.1
    • /
    • pp.37-43
    • /
    • 1992
  • KTiOP04 is a nonlinear optical crystal which is most widely used for frequency doubling of the radiation of Nd : YAG laser. In the experiment, sin ale crystals of KTiOP04 were grown by TSSG technique using 3K2W04·P2O5 flux. Low temperature gradient furnace suitable for KTP single crystal growth was used. Seed crystal was placed at the surface of the solution for the purpose of better observation of the growing crystals and the possibility of diameter control. Solution included 66.7mol% KTiOP04 for all experiments and its saturation temperature was 1020℃. The conditions of single crystal growth were as follows: cooling rate 0.2℃/h, crystal rotation rate 50rpm, c -axis seed. Using these conditions, single crystals up to 23 ×25×25mm3 have been groan from about 100cc solution. We have also observed a change in the crystal growth habit which resulted in the formation of large (201) faces and small (100) faces. And some crystals have (101) faces.

  • PDF

The spectroscopic study of chemical reaction of laser-ablated aluminum-oxygen by high power laser (고 에너지 레이저를 통한 알루미늄-산소 연소현상에 대한 분광분석)

  • Kim, Chang-Hwan;Yoh, Jai-Ick
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.608-611
    • /
    • 2011
  • Laser-induced combustions and explosions generated by high laser irradiances were explored by Laser-Induced Breakdown Spectroscopy (LIBS) in rich, and stoichiometric conditions. The laser used for target ablation is a Q-switched Nd:YAG laser with 7 ns pulse duration at wavelength of 1064 nm laser energies from 40 mJ to 2500 mJ ($6.88{\times}10^{10}-6.53{\times}10^{11}\;W/cm^2$). The plasma light source from aluminum detected by the echelle grating spectrometer and coupled to the gated ICCD(a resolution (${\lambda}/{\Delta}{\lambda}$) of 5000). This spectroscopic study has been investigated for obtaining both the atomic signals of aluminum (fuel) - oxygen (oxidizer) and the calculated ambient condition (plasma temperature and electron density). The essence of the paper is observing specific electron density ratio which can support the processes of combustion and explosion between ablated aluminum plume and oxygen from air by inducing high power laser.

  • PDF

Use of piezoelectric surgery and Er:YAG laser:which one is more effective during impacted third molar surgery?

  • Keyhan, Seied Omid;Fallahi, Hamid Reza;Cheshmi, Behzad;Mokhtari, Sajad;Zandian, Dana;Yousefi, Parisa
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.29.1-29.10
    • /
    • 2019
  • Background: Reduction in postoperative complications is of vital considerations in impacted third molar teeth surgery. The aim of this study was to compare postoperative complications of impacted third molar surgeries for bone removal using laser, piezoelectric equipment, and conventional rotary instruments. Methods: To address the research purpose, the investigator designed the prospective double-blind clinical trial study. The sample size was determined 20 (40 teeth) by sampling formula in any kind of operation. The data of patients were obtained in the different periods in terms of pain, trismus, swelling, ecchymosis, and patient's satisfaction and then analyzed using SPSS 20 software via paired t test and Wilcoxon and McNemar's tests. Results: The pain immediately after surgery and 2 days and 7 days after surgery was higher in the laser group. The swelling immediately after surgery was more in the laser group but not significant. The amount of mouth opening immediately after surgery and 2 days and 7 days after surgery was significantly lower in the laser group than in the piezosurgery group. The total duration of surgery and duration of osteotomy were significantly longer in the laser group. The patient's satisfaction from surgery with piezosurgery was more than that with laser, but this difference was not significant. Conclusion: Due to the rising demand for impacted wisdom tooth surgery, the present study suggests that hard tissue laser surgery and piezosurgery can clear the future of impacted molar surgery, and these approaches are more efficient in reducing postoperative complications compared to the conventional surgeries.

A Spatio-Temporal Density Measurement of NO Molecules in Pulsed Barrier Discharge Using Laser Induced Fluorescence (레이져 유기형광법을 이용한 펄스 배리어 방전 공간에서의 NO분자에 대한 시·공간적 밀도변화 측정)

  • Han, Sang-Bo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.160-168
    • /
    • 2010
  • This paper tried to find out NO generation and removal mechanisms in the space of the atmospheric pulsed barrier discharge using laser induced fluorescence method, which is a very effective approach to the measurement of spatio-temporal density of specific molecules. The propagation velocity of the primary streamer reaches about $2.7{\times}10^6$[m/s] and the secondary streamer is produced in the vicinity of positive electrode after the primary streamer finished. In this work, pulse Nd:Yag and Dye lasers are used for generating the specific wavelength of 226[nm], which is possible to excite NO molecules into $A^2{\Sigma}^+{\rightarrow}X^2{\prod}$(0,0) and fluorescence signals as the transition of $A^2{\Sigma}^+{\leftarrow}X^2$(0,2) is measured. For the effective removal of NO molecules in the plasma discharge process, the lower oxygen contents are needed and the influence of secondary streamer for the reduction mechanism of NO molecules is important

The spectroscopic study of chemical reaction of laser-ablated aluminum-oxygen by high power laser (분광분석을 활용한 고에너지 레이저 환경에서의 알루미늄-산소 화학반응 연구)

  • Kim, Chang-hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.9
    • /
    • pp.789-795
    • /
    • 2016
  • Laser-induced combustions and explosions generated by high laser irradiances were explored by Laser-Induced Breakdown Spectroscopy (LIBS). The laser used for target ablation is a Q-switched Nd:YAG laser with 7 ns pulse duration at wavelength of 1064 nm laser energies from 40 mJ to 2500 mJ ($6.88{\times}10^{10}-6.53{\times}10^{11}W/cm^2$). The plasma light source from aluminum detected by the echelle grating spectrometer and coupled to the gated ICCD(a resolution (${\lambda}/{\Delta}{\lambda}$) of 5000). This spectroscopic study has been investigated for obtaining both the atomic/molecular signals of aluminum-oxygen and the calculated ambient condition such as plasma temperature and electron density. The essence of the paper is observing specific electron density ratio which can support the processes of chemical reaction and combustion between ablated aluminum plume and oxygen from air by inducing high laser energy.

Change of Regional Myocardial Blood Flow After Transmyocardial Laser Revascularization in Porcine Model of Chronic Myocardial Ischemia (돼지 만성 심근허혈 모델에서 경심근레이저혈류재건술 후 국소 심근 혈류량의 변화)

  • Park, Kay-Hyun;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.662-671
    • /
    • 2001
  • Background: This study was aimed to assess improvement in myocardial perfusion after TMR by measuring regional myocardial blood flow(RMBF) in porcine model of chronic myocardial ischemia. Material and Method: Ameroid ring was placed around the proximal left circumflex coronary artery in fourteen pigs. After 4 weeks, the control group(7 pigs) underwent rethoracotomy only, and the TMR group(7 pigs) underwent Ho:YAG laser TMR at the circumflex territory. After another 4 weeks, the animals were sacrificed for the measurement of RMBF using colored microspheres. The ratio of RMBF between the circumflex territory and the interventricular septum was calculated and compared. Result: At 4 weeks after ameroid constriction, RMBF of the circumflex territory decreased to 46∼89% of RMBF of the interventricular septum. In five of six animals in the TMR group, RMBF of the circumflex territory at 8 weeks after ameroid constriction was higher compared with RMBF at 4 weeks after ameroid constriction. However, the improvement was statistically significant only in two animals. In three of the four animals in the control group, RMBF of the circumflex territory also increased at 8 weeks compared with RMBF at 4 weeks. The degree of increase in RMBF was not different between the control and the TMR groups. Conclusion: In porcine model of chronic myocardial ischemia, the degree of increase in RMBF of the ischemic area after Ho:YAG TMR was not different from the increase by development of native collateral circulation. Perfusion of ischemic myocardium after TMR is not thought to improve to the degree that can be demonstrated by currently available method of assessment such as radioisotope myocardial scintigraphy.

  • PDF

The properties of$Y_1Ba_2Cu_3O_{7-x}$ superconducting thin films deposited by 'off-axis' pulsed laser deposition (Off-axis'레이저 기법에 의한 고온 초전도 $Y_1Ba_2Cu_3O_{7-x}$박막의 특성)

  • 문병무
    • Electrical & Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.285-290
    • /
    • 1995
  • High quality $Y_{1}$Ba$_{2}$Cu$_{3}$$O_{7-x}$ thin films have been fabricated by pulsed Nd:YAG laser deposition using an unusual 'off-axis' target-substrate geometry. Various properties of superconducting $Y_{1}$Ba$_{2}$Cu$_{3}$$O_{7-x}$ thin films have been studied systematically as a function of oxygen pressure during the deposition, in both 'on-axis' and the unusual 'off-axis' target substrate geometries. In the 'off-axis' geometry, one can completely eliminate the so-called 'laser droplets' from the film surface and thus obtain smooth high quality films. It is found that films with optimum structural and electrical properties are obtained at a lower oxygen pressure range during the 'off-axis' deposition when compared with that required in the 'on-axis' deposition geometry.

  • PDF

Properties of $YBa_2{Cu_3}O_{7-X}$ superconducting thin films prepared by visible light pulsed laser (기사광선 펄스 레이저에 의해 제작된 $YBa_2{Cu_3}O_{7-X}$초전도체 박막의 특성)

  • 신현용
    • Electrical & Electronic Materials
    • /
    • v.7 no.4
    • /
    • pp.289-293
    • /
    • 1994
  • Thin films of YB $a_{2}$C $u_{3}$$O_{7-x}$ supercondYB $a_{2}$C $u_{3}$$O_{7-x}$uctor were prepared on (100) SrTi $O_{3}$ substrates by pulsed laser deposition using visible light laser. Q-switched Nd:YAG(532 nm, 30 ns) pulsed laser was used for deposition. The effects of substrate temperature and oxygen pressure during deposition on films were studied. Critical current density of 2.93*10$^{6}$ A/c $m^{2}$ at 77K and Tc(zero)=91.7K were obtained from the film prepared with Tsub=745.deg. C and $P_{02}$=200 mTorr. XRD analysis showed that the grown film has c-axis normal orientation to the substrate surface and has single phase. Surface morphology of the film has been improved by interfering the plume ejected from YB $a_{2}$C $u_{3}$$O_{7-x}$ target.arget.t.

  • PDF

Laser-Droplet Free high-$T_c$ Superconducting thin films by Pulsed Laser Deposition (PLD를 이용한 레이저 드롭릿 없는 고온 초전도 박막의 형성)

  • Hwang, Eui-Hyeon;Kim, Hui-Kwon;Moon, Byung-Moo
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.361-363
    • /
    • 1995
  • High quality $Y_1Ba_2Cu_3O_{7-x}$ thin films have been fabricated by pulsed Nd:YAG laser deposition using an unusual 'off-axis' target-substrate geometry. Various properties of superconducting $Y_1Ba_2Cu_3O_{7-x}$ thin films have been studied systematically as a function of oxygen pressure during the deposition, in both 'on-axis' and the unusual 'off-axis' target substrate geometry. In the 'off-axis' geometry, one can completely eliminate the so-called 'laser droplets' form the thin surface and thus obtain smooth high qualify films. It is found that films with optimum structural and electrical properties are obtained at a lower oxygen pressure range during the 'off-axis' deposition when compared with that required in the 'on-axis' deposition geometry.