• 제목/요약/키워드: Xenon Lamp

검색결과 112건 처리시간 0.03초

Design of Solar Cell Cooling System Using Convection Phenomena

  • Lee, Jae-hyuk
    • International journal of advanced smart convergence
    • /
    • 제9권2호
    • /
    • pp.123-128
    • /
    • 2020
  • We constructed a cooling system for solar cells using convection phenomena and investigated its cooling performance. The cooling system didn't need any driving power or water resources. The convection cooler manufactured with a right-triangle shape of an air duct was attached to the rear of the solar cell to confirm that cooling was performed using convection phenomena. When the ratio of duct width to attachment surface width was 3:7, and the ratio of entrance height and exit height of duct was 5:1, it showed the best cooling performance. Comparative experiments with solar cells without convection cooler showed that cooling effects from 16.5℃ to 20.9℃ occurred after 40 minutes exposed to the 1300W Xenon lamp condition.

광섬유 대기오존 모니터 (Optical Fiber Atmospheric Ozone Monitor)

  • 정완영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.201-204
    • /
    • 2002
  • A high accuracy ozone monitor using UV absorption method was developed for ambient ozone monitoring. The system was mainly composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit. The optical signal from the CCD array that provides unusually high response and excellent optical resolution for ozone concentration was converted to digital signal and the digital signal was displayed on screen using PC interface. The optical signal was propagated using optic fiber to reduce optical loss to increase the accuracy of the measuring system. This paper has been studied a interworking signalling protocol between two hybrid networks by analyzing Satellite B-ISDN architecture, DSS2 Layer 3 Signalling protocol, B-ISUP protocol, S-BISUP protocol stack and so on. Also in the paper, messages and primitives have been defined for B-ISDN's Connection Type, Ownership and each protocol in order to connect point-to-multipoint. The ozone sensing properties of the CCD ozone monitor was compared with those of the photo multiplier ozone monitor.

  • PDF

Photovoltaic Effects in CuPc/C60 and ZnPc/C60 Depending on the Organic Layer Thickness

  • Ahn, Joon-Ho;Lee, Joon-Ung;Lee, Won-Jae
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권3호
    • /
    • pp.115-118
    • /
    • 2005
  • Organic photovoltaic properties were studied in $CuPc/C_{60}$ and $ZnPc/C_{60}$ heterojunction structure by varying the organic layer thicknesses. Current density-voltage characteristics of organic photovoltaic cells were measured using Keithley 236 source-measure unit and a 500 W xenon lamp (ORIEL 66021) for a light source. From the analyses of current-voltage characteristics such as short-circuit current density, open-circuit voltage and power conversion efficiency, optimum thickness of the organic layer were obtained.

제논램프 구동을 위한 새로운 기법의 고전압 발생회로 (Novel High Voltage Generator Circuit Design for Igniting Xenon Lamp)

  • 전병구;조준동
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.180-182
    • /
    • 2008
  • 제논램프를 점등시키기 위해서는 램프방전 초기에 수십kV의 고전압펄스를 발생시켜주어야 한다. 고전압펄스의 생성은 주로 transformer의 전자기유도작용을 이용한다. 지금까지는 주로 1개의 고주파 transformer를 이용하여 고전압펄스를 발생시키는 회로가 구성되어 왔다. 이 경우 회로가 단순해지는 이점이 있지만 transformer의 부피가 커지게 되어 상대적으로 보드에서 많은 공간을 차지하게 되는 단점이 있다. 따라서 본 논문에서는 기존의 단점을 해결하고자 고주파 transformer 1개를 사용하는 대신 소형의 고주파 transformer 2개를 2단계 step-up 회로로 구성하였다. 제안된 회로의 구성과 동작에 대하여 분석하였고 실험을 통해 제안된 회로가 유용함을 검증하였다.

  • PDF

양친매성 스쿠아릴리움색소 초박막의 전기적 특성 (Electrical Properties of Amphiphillic Squarylium Dye Ultra Thin Films)

  • 정순욱
    • 한국응용과학기술학회지
    • /
    • 제20권2호
    • /
    • pp.177-181
    • /
    • 2003
  • Ultra-thin films of amphiphillic squarylium dye were prepared on the hydrophillic substrate by Langmuir-Blodgett(LB) technique. In this study, the photoelectric properties of a amphiphillic squarylium dye LB film was investigated. The visible light(${\lambda}$ = 684nm ) of xenon lamp was illuminated on the amphiphillic squarylium dye LB films and light absorptivity and photoconductivity were observed. The photoconductivity was nearly constant regardless of nominal layer number. The photoelectric properties of the amphiphillic squarylium dye LB films with bottom electrode showed better than that top electrode.

고전압.대전류 pulse방전의 전압.전류특성에 관한 연구 (A Study on Voltage-Current characteristics of High-Voltage.Current Pulsed Discharge)

  • 서길수;조국희;김영배;이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1981-1983
    • /
    • 2000
  • In this paper, the arc resistance of INPIStron is presented. It is need to the design of Pulsed power system and simulation on the circuit of pulsed power system with INPIStron switch. It is also possible to use this parameter to the part of discharge characteristics of Xenon lamp and the device with electrical discharge.

  • PDF

ICP 제논 램프의 가스 압력과 공급 전력에 따른 광학적 특성연구 (The Study on Optical Properties of Xenon ICP Lamp Dependently on Gas Pressure and Input Power)

  • 최기승;이성진;이종찬;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1659-1660
    • /
    • 2006
  • After end of the 20th environmental problem was became issue. So about mercury free lighting sources are being studied very much. In this paper, a mercury and electrode free bulb was designed. in this bulb was injected mixed of Xe, Ne and Kr Gases. and then the bulb was discharged by 13.56MHz RF Power after spectrum, color coordinates and brightness were measured by spectrum meter CS-1000. Measured results were compared and analyzed, also analysis was able to do a characteristic of a gas defensive fight in proportion to a mixing ratio. Therefore the most of high brightness which was 4500cd/m2 was gained in 1:1 ratio of Xe:Ne at 60W input power.

  • PDF

신경망 적용의 온도장 측정법 개선 방안 (Improvements of Temperature Field Measurement Technique using Neural Network)

  • 도덕희;김동혁;방광현;문지섭;홍성대;장태현;황태규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권2호
    • /
    • pp.209-216
    • /
    • 2005
  • Thermo-chromic Liquid Crystal(TLC) particles were used as temperature sensor for thermal fluid flow. 1K $\times$ 1K CCD color camera and Xenon Lamp(500w) were used for the visualization of a Hele-Shaw cell The characteristic between the reflected colors from the TLC and their corresponding temperature shows strong non-linearity A neural network known as having strong mapping capability for non-linearity is adopted to quantify the temperature field using the image of the flow. Improvements of color-to-temperature mapping was attained by using the local color luminance (Y) and hue (H) information as the inputs for the constructed neural network.

동적 패턴 생성기를 이용한 3차원 미세 구조물의 경화특성 (Curing Characteristics for 3D Micro-structures Fabrication using Dynamic Pattern Generator)

  • 하영명;최재원;안대건;이석희;하창식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.514-517
    • /
    • 2005
  • Microstereolithography(MSL) has evolved from the stereolithography technique, and is also based on a light-induced layer-stacking fabrication. Although integral MSL allows the manufacture of a complete layer by one irradiation only, there is a problem related with shape precision due to the light-intensity distribution of focused image. In this study, we developed the integral MSL apparatus using Digital Micromirror Device ($DMD^{TM})$, Texas Instruments) as dynamic pattern generator. It is composed of Xenon-Mecury lamp, optical devices, pattern generator, precision stage, controllers and the control program. Also, we have studied curing depth and width of photocurable resin according to the change of exposure energy.

  • PDF

누전차단기 하우징의 내후성에 관한 연구 (A Study on the Weathering of RCD'S Housing)

  • 김창환;신진용;강병철;김상명
    • 한국표면공학회지
    • /
    • 제47권6호
    • /
    • pp.335-340
    • /
    • 2014
  • This study selected an outdoor RCD'S and verified behavior of change in the housing with time. Weathering tests were carried out as outdoor exposure test (90 degrees, 37 degrees) and laboratory test (xenon lamp), and the results were evaluated based on color difference, gloss, contact angle, and optical microscope. This study can provide basic data for standardization of development and performance evaluation on RCD'S housing products.