• Title/Summary/Keyword: XRD 분석

Search Result 2,855, Processing Time 0.035 seconds

Analysis of CaCO3 structure of marine bivalves using X-ray diffraction (해산 이매패류 패각의 CaCO3 결정 구조에 대한 X-ray 회절 분석)

  • Nam, Ki-Woong;Lee, Seng-Woo;Song, Jae-Hee;Jeung, Hee-Do;Park, Kyung-Il
    • The Korean Journal of Malacology
    • /
    • v.31 no.4
    • /
    • pp.279-283
    • /
    • 2015
  • This study investigated spectroscopic characteristics of shell crystals of eight marine bivalve species using X-ray diffraction (XRD) analysis; moreover, the Family level relatedness of shellfish was investigated. In XRD analysis, the shells of Ruditapes philippinarum, Meretrix lusoria, Anadara granosa, and Fulvia mutica were found to have orthorhombic aragonite $CaCO_3$ crystals, while shells of Patinopecten yessoensis and Crassostrea gigas had trigonal-rhombohedral calcite crystals. The shells of Mytilus coruscus and Atrina pectinata were determined to have a mixture of aragonite and calcite crystals. XRD information revealed the Family level-specific characteristics of shellfish; the results agreed with the current taxonomic system. In conclusion, spectroscopic characteristics of shell crystals indicated Family-level characteristics of shellfish and suggested a more intense species-level investigation; this technology may be useful in identifying shellfish species using small quantities of shells.

Effects of Electrode Material on Electrochemical Conversion of Carbon Dioxide Using Molten Carbonate Electrolyte (용융탄산염 전해질에서 이산화탄소의 전기화학적 전환에 전극 재질이 미치는 영향)

  • Ju, Hong Su;Eom, Seong Yong;Kang, Ki Joong;Choi, Gyung Min;Kim, Duck Jool
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.11
    • /
    • pp.727-734
    • /
    • 2017
  • The electrochemical conversion of $CO_2$ is one of the methods for reducing $CO_2$. Four materials (Ag, Ni, Pt, and Ir) were selected as the electrodes. The electrochemical conversion was performed under a cell voltage of 4.0 V at $600^{\circ}C$. The amounts of $CO_2$ reduction and carbon production were at the highest for Ag, followed by, Pt, Ni, and then Ir. The produced carbon samples were analyzed by thermogravimetric analysis and XRD. The thermogravimetric analysis results indicated that all the carbon produced at each electrode exhibited similar thermal reactivity. The XRD results showed that the crystallization of carbon was different depending on the electrode utilized. Although electrochemical conversion was the highest for the Ag electrode, a loss of material accompanied it. Therefore, for this study, the optimal electrode is Pt, taking into account reactivity and material losses.

The Analysis of Slag Exacavated from Jisa area (지사동 출토 제철슬래그의 금속학적 조사 연구)

  • Park, Sung-Taik;Choi, Chang-Ock
    • Journal of Conservation Science
    • /
    • v.16 s.16
    • /
    • pp.64-76
    • /
    • 2004
  • This study was performed by chemical analysis and metallographic observation. Chemical properties were analized by ICP, XRD and SEM-EDS and slag structures were observed by microscope and SEM. Total Fe amounts in A, C area of slag can be observed $39\~45\%$ by chemical analysis results. It was average of acient times. CaO was $3\~8\%$. It's not plentiful but we think that was artificial. Ti was found in A area a little, and Ti, V were found in C area so much. The compounds, as if Fayalite, Wustite, Magnetite, Ilmenite, Pseudo-brookite, Ulvospinel, Forsterite, Fephroite, Olivine were observed in the result XRD. These structures were also observed in microscope and SEM image. Therefore, The furnance of A area usually used an iron mine, An Iron furnance of C area considered it which refined using a raw iron mine and a raw iron sand.

  • PDF

Preparation of Kenyaite/epoxy Nanocomposite from Pulverization of Kenyaite (분쇄된 Kenyaite를 이용한 Kenyaite/epoxy 나노복합체 제조)

  • Joo, Eul-Rea;Jeong, Soon-Yong;Oh, Seong-Geun;Kwon, Oh-Yun
    • Applied Chemistry for Engineering
    • /
    • v.18 no.1
    • /
    • pp.48-53
    • /
    • 2007
  • Pulverization characteristics of H-kenyaite in vibration mill and exfoliation property in epoxy of pulverized H-kenyaite was investigated by using XRD, SEM, TEM. and particle size analyzer. Pulverization was conducted for 0.5~5 h. The particle morphology of sample pulverized for 1 h preserved plate-shape. However, this plate-shape disappeared in the sample pulverized for 3 h. The XRD pattern of sample pulverized for 1 h showed the characteristic peak of H-kenyaite. However, the peak disappeared in samples pulverized above 3 h, indicating severe destruction of H-kenyaite structure. TEM analysis for the kenyaite/epoxy nanocomposites exhibited only gallery expansion of 3~5 nm in non-pulverized sample, but dramatical large expansion of 5~10 nm in the samples pulverized during 1 h. This results confirm that the pulverization of wide plates composed of H-kenyaite particle have largely affect on the formation of an exfoliated kenyaite-polymer nanocomposite.

Performance Evaluation of High Strength Concrete with Composite Fibers in Accordance with High Temperature (복합섬유가 혼입된 고강도 콘크리트의 고온가열에 따른 성능 평가)

  • Kim, Seung-Ki;Kim, Woo-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.63-71
    • /
    • 2015
  • The objective of the present study is to investigate how elevated temperature ranging from $100^{\circ}C$ to $800^{\circ}C$ as well as room temperature affects the variation of mechanical properties of high strength concrete ($over\;f_{ck}=60MPa\;grade$). In this experiment, specimens were exposed for a period of $2^{\circ}C/min$ to temperatures of $20^{\circ}C$, $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$ $400^{\circ}C$, $500^{\circ}C$, $600^{\circ}C$, $700^{\circ}C$ and $800^{\circ}C$, respectively. Accordingly, the study investigated the fire resistance performance of high strength concrete mixed with composite fibers which composed with hybrid fibers and steel fibers. After cooling down to ambient temperature, the following basic mechanical properties were then evaluated and compared with reference values obtained prior to thermal exposure: (i) compressive strength in room temperature; (ii) residual compressive strength; (iii) Poisson's ratio; (iv) weight change; (v) SEM analysis & XRD analysis In addition, XRD and SEM Images analyses were performed to investigate chemical and physical characteristics of high strength concrete with composite fibers according to high temperature.

A thermal properties of micro hot plate and the characteristics of Pt/Cr bilayers due to annealing temperature (미세 발열체의 발열특성과 열처리 온도에 따른 Pt/Cr 이중층의 특성)

  • Yi, Seung-Hwan;Suh, Im-Choon;Sung, Yong-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.69-77
    • /
    • 1996
  • In this paper, we fabricated the micro hotplate which consisted of a thin film heater(Pt/Cr bilayers) sandwiched with the thermal oxide and E-beam evaporated oxide. And we studied the electrical and the structural properties of Pt/Cr bilayers due to annealing temperature. When we compared the temperature measured from type k thermocouples with the temperature acquired from I.R. thermo-vision system according to the variations of emissivity, the emissivity of I-beam evaporated oxide was 0.5. The sheet resistance of Pt/Cr bilayers didn't depend on the Cr layer thickness, and it was considered as the existence of CrO between the Pt and the Cr layer. When the annealing temperature was increased from $500^{\circ}C$ to $700^{\circ}C$, the out-diffusions of Cr were increased(which was confirmed by AES depth profile) and the grain size of Pt(220) phase was enlarged also(analyzed by XRD and SEM photographs). From the results of XRD analysis and AES depth profile, the Pt/Cr bilayers annealed at $500^{\circ}C$ were more stable than any other cases in structural properties.

  • PDF

The Control Method of Scale in Drainage Pipe of Deteriorated Tunnel used Magnetic Field and Quantum Stick (자화장치와 퀀텀스틱을 이용한 노후터널의 배수공내 침전물 방지 방법)

  • Nam, Joongwoo;Lee, Changgi;Lee, Jonghwi;Do, Jongnam;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.11
    • /
    • pp.59-64
    • /
    • 2011
  • Clogging in drainage pipe is one of the important problems, so it needs a remedy urgently. Recently, scale in drainage pipe is removed by water jet cleaning and other treatment. But these treatments need much cost and regular management. The principal component of scale in drainage pipe is $CaCO_{3}$. It was observed the setting of $CaCO_{3}$ by some kind of analysis such as SEM, XRD, visual and weight measuring analysis to solve these problems and prevent setting formation in drainage pipe. As a result, in case of magnetic, particle shape of $CaCO_{3}$ is changed Aragonite from Calcite. Also in case of Quantum Stick, the amount of scale is reduced by expert inspector's result. As a whole, Magnetic treatment and Quantum Stick have the effect for protecting of scale precipitation.

PRAM 소자를 위한 GST의 결정화 및 HRTEM분석

  • 박유진;이정용;김성일;염민수;성만영;김용태
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2005.09a
    • /
    • pp.73-77
    • /
    • 2005
  • 고분해능 투과전자현미경을 이용하여 PRAM소자의 상변화물질인 $Ge_{2}Sb_{2}Te_{5}(GST)$의 결정화에 관해 미세구조 분석을 수행하였다. 결정성을 측정하는 일반적인 방법인 XRD법에 비해 고분해능 투과전자현미경을 이용한 미세구조 분석은 XRD에서 분석할 수 없는 결정화 초기 양상을 분석할 수 있을 뿐만 아니라, 소자내부의 국부적인 영역과 같이 특정한 영역에서의 결정구조 및 원자배열에 관한 분석이 가능하였다. 이를 통해 GST박막의 전기적 특성이 결정립 크기에 직접적으로 연관성이 있음을 밝혀내었다. GST의 결정구조 및 원자배열에 관해서는, 제한시야전자회절 기법을 통해 준안정상에서의 GST는 FCC 구조를 가지고 안정상의 GST는 hexagonal 구조를 가짐을 보여주었으며, 고분해능 이미지 관찰을 통해 원자단위로 GST의 결정성을 규명하였다.

  • PDF