열수축형을 이용한 XLPE케이블 종단부의 전기적 특성 (Electrical Properties of XLPE Cable Termination using Thermal Contraction Type)

  • 백승명;최재형;최진욱;김상현;김영석;김선구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.395-396
    • /
    • 2009
  • For investigation of electrical properties of XLPE cable termination, we prepared a thermal contraction type kit and 6.6kV XLPE cable. The cable termination that have simulated defect by badness construction have been manufactured and their insulation characteristics such as ac and impulse withstand test have been measured. The influence of defects such as thickness decrease and heating time have been studied. When thickness decreased 1mm, the decreased of AC breakdown voltage value is not very distinctive. However, when thickness decreased 2mm, the insulation AC breakdown voltage value was very low down to 43kV. When approved heat for 300s than 60s, AC Breakdown voltage value appeared high. And also, after insulation breakdown took place, the sample was observed before and after disassembly, and the insulation breakdown hole was observed by means of optical microscope.

  • PDF

운전 중인 고전력 XLPE 케이블의 절연저항과 습도의 측정 시스템 설계 및 방식층 절연저항과 습도의 상관관계 (Design of Measuring System for Insulation Resistance and Humidity in High-Power XLPE Cables in Operation and the Relationship Between Insulation Resistance and Humidity in the Oversheath)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권5호
    • /
    • pp.179-184
    • /
    • 2016
  • 발전소가 생산한 고전압 전력을 전달하기 위해 사용하는 케이블은 주로 6.6 kV XLPE 케이블(또는 CV케이블)이다. 제작 기술, 설치환경 및 사용조건에 다르겠지만, 케이블은 설치하여 동작함과 동시에 열화과정이 진행된다. 접속재의 경우, 제조 결함이나 공사 결함이 있는 경우 대체로 동작 후 약 3 년 내에 고장을 일으키며, 그렇지 않는 경우 수명이 20-30 년을 지속하는 경우가 많다. 케이블 시스템(케이블 자체 및 접속재)의 상태가 나빠지는 경우, 절연 파괴현상으로 인한 사고가 발생한다. 우리는 케이블의 열화 상태를 감시하기 위한 장비를 개발하여 충남 태안의 한국서부발전주식회사(Korean Western Power Co. Ltd.)에 설치하였다. 이 논문에서, 운영 중에 있는 장비의 하드웨어적인 설계를 소개한다. 그 장비를 사용하여 고전력 케이블의 방식층 절연저항과 습도를 측정하였으며, 습도가 방식층의 절연저항에 미치는 영향을 분석한 결과를 제시한다.

터빈 발전기 부하용 XLPE 6.6kV 케이블의 절연층 절연상태와 습도의 상관관계 (Relationship Between Humidity and Insulation Status of XLPE 6.6kV Cables for the Load of Electric Turbine Generator)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권5호
    • /
    • pp.185-190
    • /
    • 2016
  • 국내 발전소에서 운전 중인 XLPE 케이블(또는 CV케이블)은 많은 경우 포설된 지 40년에 이르고 있다. 설치 후 운전 상태에 있는 대부분의 CV 케이블은 6~8년의 기간이 경과하면 열화가 발생하기 시작하고, 근래에 포설한 케이블이라 할지라도 사고가 발생할 수가 있으며, 사고 발생으로 인하여 막대한 손실을 초래하게 된다. 사고를 미연에 방지하기 위하여 케이블의 동작상태를 정기적으로 감시 확인하여야 한다. 우리는 케이블의 사고를 체계적으로 감시 및 예방하기 위한 목적으로 측정 시스템을 개발하였다. 이 장비는 수 년 동안 충남 태안에 소재한 한국서부발전주식회사(Korean Western Power Co. Ltd.)에서 케이블의 동작 상태를 감시하고 있다. 이 논문에서 시스템의 기능 및 동작 원리를 소개하고, 터빈 발전기 부하용 XLPE 고압케이블의 절연층 절연상태와 습도의 상간관계를 제시한다.

통계적 기법을 이용한 전력 케이블 절연층(XLPE)의 수명 예측 (Life Expectancy for Power Cable Insulation(XLPE) Using Statistical Method)

  • 이승엽;조대희;이인호;박완기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.57-61
    • /
    • 1999
  • Electrical stress makes insulating materials aged finally resulting in the dielectric failure. It becomes more and more important to recognize the degree of aging and the life time of the insulating materials since it is directly concerned with the reliability of the insulation system. In this paper, the life time of the Cross-linked Polyethylene(XLPE), the insulation layer in the 154kV-grade power cable, is expected and calculated using statistical and mathematical methods. The simulated results are compared with experimental ones and the life exponent of the material is obtained.

  • PDF

XLPE 절연체의 트리 채널내 보이드방전에 의한 AE신호로 절연열화 검출 기법 연구 (Fundamental Study of Degradation Diagnosis using AE Signals with Void Discharge in XLPE Insulation)

  • 이상우
    • 조명전기설비학회논문지
    • /
    • 제20권2호
    • /
    • pp.75-80
    • /
    • 2006
  • 본 논문은 전력 케이블의 절연체인 XLPE 시료에 상용주파수 교류전압을 인가하였을 때, 절연열화에 의한 보이드방전 펄스신호와 AE신호 및 트리진전 특성을 검출하고 관찰하였다. 또한 XLPE 절연체의 트리 채널내 인가전압에 따라 보이드방전 펄스신호와 AE신호를 각각 관측하였다. 실험 결과 전력 케이블의 절연체인 XLPE 시료의 보이드 존재 유 무에 따른 트리진전 형상은 보이드 존재시에는 수지형으로 성장하였으나, 무보이드시에는 수초형으로 성장하였다. XLPE 절연체내의 트리진전 특성은 보이드 존재시에는 열화시간이 경과함에 따라 급격히 증가하였으나, 무보이드시에는 열화 시간이 경과함에 따라 트리의 성장 형상은 감소되는 것으로 나타났다. 전력 케이블 절연체인 XLPE의 트리 채널내 보이드방전에 의한 AE신호의 주파수 스펙트럼으로 분석한 결과, AE신호의 크기에 따라 변화되었으며 그 주파수 영역은 대략 1.0[MHz] 이하의 분포인 것으로 관측되었다.

고주파 전압이 XLPE cable의 가속열화에 미치는 영향 분석 (Analysis of Influence for High Frequency voltage Accelerated Aging of XLPE Cable)

  • 김위영;허종철;윤대혁;박태곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1670-1672
    • /
    • 2004
  • XLPE compound have used for insulation of 22.9kV power cable. XLPE insulation is aged for use long time in distribution line. The cause of aging is water tree is happening and growth. Accelerated water tree test method are Accelerated volatge aging method and high frequency aging method. In this paper, high frequency accelerated water tree was performed. And the result was analysed AC breakdown voltage and size and number of water trees.

  • PDF

22.9kV 트리억제형 전력케이블의 성능평가 (Efficiency appraisal of 22.9kV tree retardant power cable)

  • 김위영;윤대혁;박태곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.179-182
    • /
    • 2002
  • XLPE compound have used for insulation of 22.9(kV) power cable. But tree retardant power cable has developed and is going to br used commonly. TR XLPE compound retard production and growth of water tree. In this paper, tensile strength, elongation at break, degree of crosslinking, lightning impulse test, AC breakdown test, cyclic aging for 14days and accelerated water treeing test of TR XLPE insulated power cable were examined according to the KEPCO buying spec. & AEIC CS 5-94 standards. before and after As the result, tensile strength, elongation at break and degree of crosslinking test results of TR XLPE insulation were higher than requirement values. After accelerated water treeing test for 120 days, 240 days and 360 days, AC breakdown voltages were not decreased for accelerated water treeing aging duration

  • PDF

Influence of Endurance tests on Space Charge Distribution of 160kV HVDC XLPE Cable

  • Liu, Yun-Peng;Liu, He-Chen
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.302-309
    • /
    • 2017
  • The ageing of XLPE cable insulation will lead to the accelerating accumulation of space charge, which will greatly affect the safe operation of the HVDC cable. In order to investigate the influence of different ageing modes on the space charge distribution of the HVDC cable, thermal stressed, electrical stressed and electro-thermal stressed endurance tests were carried out on the XLPE peelings. The tested XLPE peelings were obtained from 160kV HVDC cable insulation. The endurance tests were carried at thermal stress of 363K, electrical stress of 20kV/mm DC and a combination of both. The Pulsed Electro-Acoustic (PEA) method was used to measure the space charge distribution of the samples. The influences of ageing on the trap energy distribution were analyzed based on the isothermal relaxation theory and the decay characteristics of the space charge. The results showed that thermal ageing would help to improve the crystalline morphologies of the XLPE at the early stage. The total amount of space charge decreased compared to the ones before thermal ageing. The long term of electrical stress would result in the cleavage of polymer molecule chains which would intensify the accumulation of space charge and increase the density and depth of electron traps. With a combination of electrical and thermal stress, the injection and migration of space charge were more significant. Besides, the depth and density of electron traps increased rapidly with the increase of endurance time.

고전력 활선 XLPE 케이블의 열화를 측정하기 위한 판정기준의 적용 및 절연상태 판정 (Application of Judgement Criteria to Measure Deterioration and to Judge Insulation Resistance in High-Power Live XLPE Cables)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권2호
    • /
    • pp.239-244
    • /
    • 2017
  • 전력 수요는 매년 증가추세에 있으며, 이에 따라 발전소에서 동작하는 모든 장비들과 대용량의 장거리 전력수송을 위한 장비들은 신뢰할 수 있는 수준에서 완전한 상태로 동작하여야 한다. 발전소에서 생산한 고전압 전력을 전달하기 위해 사용하는 케이블은 주로 6.6 kV XLPE 케이블(또는 CV케이블)이다. 제작 기술, 설치환경 및 사용조건에 다르겠지만, 케이블은 동작함과 동시에 열화과정이 진행된다. 접속재의 경우, 제조 결함이나 공사 결함이 있는 경우 대체로 동작 후 약 3 년 내에 고장을 일으키며, 그렇지 않는 경우 수명이 20-30 년을 지속하는 경우가 많다. 우리는 케이블의 열화 상태를 감시하기 위한 장비를 개발하여 충남 태안의 한국서부발전주식회사(Korea Western Power Co. Ltd.)에 설치하였다. 우리는 이 논문에서 케이블의 열화 판정의 기준을 설정하고, 기준에 따른 열화정도를 판정하고, 케이블의 대체여부를 결정함으로써 발전소에서 설치된 활선 케이블의 동작 상태를 감시한 결과와 케이블을 구성하고 있는 절연체와 방식층이 절연저항 특성에 미치는 영향 및 케이블의 동작에 미치는 영향을 연구한 결과를 제시한다.

XLPE 케이블의 비등방성이 가지는 전기.기계적 특성 (The Effect of Angular Anisotropy in XLPE Insulation on Dielectric Strength)

  • 조대희;이상진;김영호;박완기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.432-435
    • /
    • 2003
  • 최근 초고압 케이블 절연체로 XLPE(가교 폴리에틸렌)이 널리 사용되어 지면서 XLPE의 여러 물리 화학적 특성에 따른 절연 성능에 관한 연구가 활발히 이루어지고 있다. 이러한 XLPE 절연층은 제조과정에서 압출과정을 거쳐 도체를 감싸게 되는데 이 과정에서 흐름 패턴으로 나타나는 비등방성(anisotropy)을 띠게된다. 본 논문에서는 초고압 XLPE 케이블에서 시계 방향으로 나타나는 비등방성(anisotropy)이 나타내는 기계-전기적 특성을 인장강도(tensile strength), 트리 개시전압 및 개시시간을 측정한 결과를 토대로 고찰해 보았으며, 이러한 비등방성이 초고압 XLPE 케이블의 절연 성능에 영향을 주는 인자로 고려되어야 함을 알 수 있었다.

  • PDF