• 제목/요약/키워드: XLPE insulation

검색결과 148건 처리시간 0.023초

내부 보이드 결함에서 발생하는 전기트리의 부분방전 특성 (PD Characteristic of Electrical Tree Generated by Inside Void Defect)

  • 박성희;정해은;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.334-335
    • /
    • 2006
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE (cross-linked polyethylene). And the size of the specimen is 7*5*7 $mm^3$. Distance of needle and plane is 2 mm. Voltages applied for acceleration test are 12 kV to 15 kV. And distribution characteristic of degraded stage is studied too. As a PD detecting and data process, discharge data acquire from PD detecting system (Biddle instrument). The system presents statistical distribution as phase resolved. Moreover the processing time of electrical tree is recorded to know the speed of degradation according to voltage.

  • PDF

전기차단성 소재 기술 (Technology of Electrical Barrier Material)

  • 신은미
    • Elastomers and Composites
    • /
    • 제46권1호
    • /
    • pp.22-28
    • /
    • 2011
  • 전기의 흐름을 막는 절연재료는 다양한 전기/전력기구에서 도체에 흐르는 전기를 차단하면서 도체와 외부를 분리/지지하는데 사용한다. 절연재료에는 유리, 절연유, 가스, 종이, 고분자가 있으며 현재는 주로 고분자 절연재료가 전선에 사용된다. 최근 환경규제 및 친환경 소재로의 변화에 따라 고분자 절연재료에 사용되는 물질들도 친환경 화하고 있다.

직류내전압 시험이 전력케이블(CV) 절연체에 미치는 영향연구 (A Study on the DC Voltage Withstand test for the Ageing of XLPE Power Cable)

  • 이준;임용배;김종서
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.613-616
    • /
    • 1999
  • Polyehtylene[PE] in polymer insulation materials of used power cable have carried out in abundance of experiment and study for electrical conduction, insulation breakdown, dielectric character and so on. when apply to field for power cable to make PE, application of DC withstand test to put in practice for inspection is get to effect accumulated space charge. In this paper, to make use of Pulsed Electro-Acoustic(PEA), It is analysis to take shape space charge under AC and DC, clear up the point at issue for DC withstand test impressing

  • PDF

전기트리 발생/열화진행과 PD와의 관계분석 (Analysis relationship with PD characteristics and occurrence of electrical treeing)

  • 정해은;박성희;임기조;강성화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1476-1477
    • /
    • 2006
  • Solid insulation exposed to voltage is degraded and by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE(cross-linked polyethylene). And the size of the specimen is 7*5*7 $mm^3$. Distance of needle and plane is 2mm. Voltage applied for acceleration test are 12kV. And distribution characteristic of degraded stage is studied too. As a PD detecting and data process, discharge data acquire from PD detecting system(Biddle instrument). Their results of PD distribution show good present and are good discriminating skill.

  • PDF

HDPE/EVA혼합수지의 공간 전하 분포에 관한 연구 (A Study on Space Charge Distribution of HDPE Mixed with EVA)

  • 정의환;허준;윤재훈;임기조;이흥규
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2229-2235
    • /
    • 2009
  • In this paper, each specimen blended at weight proportions of 80% HDPE to 20% EVA, 70% HDPE to 30% EVA, 60% HDPE to 40% EVA, and 50% HDPE to 50% EVA was manufactured respectively. The insulation performances of the proposed insulator were compared with conventional XLPE, main insulating material of CV cable on the basis of the investigation results of DC insulation performances. From the space charge density, electric field and potential profiles with raising DC voltage and time variation in HE82, distortion of electric field distribution was improved. As EVA mixed into the bulks acts as nucleation in crystallization process of HDPE, the size of spherulites became decreased and finally formed continuous network structure. Ultimately, it resulted from extinction of space charge in the interfacial region of spherulites.

내부결함에서 나타나는 전기트리의 부분방전 특성 (PD Characteristic of Electrical Tree Generated by Internal Defects)

  • 김병철;윤재훈;박성희;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1387-1388
    • /
    • 2007
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experiment, specimens of electrical tree models were made by three types of XLPE (cross-linked polyethylene). And distribution characteristics of degraded stages are studied too. As a method of detecting and data process, discharge data was acquired from PD detecting system (Biddle instrument). And microscope and digital camera were used to observe the morphologies of the electrical tree to divide stages of the tree. The system presents statistical distribution as phase resolved. Moreover the processing time of electrical tree is recorded to know the speed of degradation according to voltage.

  • PDF

XLPE 케이블에서 보이드 결함의 부분방전 특성과 위치추정 (Partial Discharge Characteristics and Localization of Void Defects in XLPE Cable)

  • 박서준;황성철;왕국명;길경석
    • 한국철도학회논문집
    • /
    • 제20권2호
    • /
    • pp.203-209
    • /
    • 2017
  • 전력공급의 안정성 및 신뢰도 향상을 위해 각종 전력설비의 예방진단에 관한 연구개발이 활발하다. 가스절연개폐장치와 변압기와 같은 단위 기기의 절연진단기술은 빠르게 발전하고 있으나, 전력케이블에 있어서는 단순히 결함의 유무와 부분방전을 측정할 뿐, 세부적 특성에 대해서는 거의 연구되고 있지 않다. 따라서 본 논문에서는 XLPE 케이블에서 보이드의 크기와 위치에 따른 부분방전 특성과 결함의 위치추정에 관한 연구를 수행하였다. 보이드의 크기 및 위치에 따른 4종의 결함계를 모의하였으며, 부분방전펄스는 주파수 대역 150kHz~30MHz의 고주파변류기로 검출하였다. 실험결과, 도체에 인접한 결함일수록 방전전하량이 크고, 정극성에 비해 부극성의 방전펄스 수가 약 20% 많게 나타났다. 또한 TDR 방법으로 결함위치를 산출하였으며, 50m 케이블에서 1m 이내로 결함의 위치를 추정할 수 있었다.

초고압 XLPE 케이블용 조립형 직선 접속함을 모의한 계면질서의 부분방전 패턴 연구 (A Study of Partial Discharge Patterns On the Simulated Interface of Prefabricated Joint for Ultra Power Cable)

  • 백주흠;김정년;신두성;이창영;김충식;김동욱;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1102-1104
    • /
    • 1999
  • It is very essential to find out defects and remove them in the insulation at the early stage because the defects in the insulation induce PD which deteriorates the material, resulting in the breakdown. In the real application of high voltage, the interface of the different insulation is the weakest place for both electrical and mechanical aspects. In this paper, characteristics of PD caused by the artificial defects, such as metallic particles, voids and moist fibers, at the interfaces of the cable joint (PJB) were investigated using the specially designed electrode system.

  • PDF

펄스정전응력법(PEA)을 이용하여 측정한 고분자 절연재료 내에서의 공간전하분포 신호에 대한 보정 처리 연구 (A Study on the Correction Processing for the Signal of the Space Charge Distribution in Polymer Insulating Materials Measured by PEA Method)

  • 민우민;강종민;김형규;박준도;황보승
    • 전기학회논문지
    • /
    • 제67권7호
    • /
    • pp.860-864
    • /
    • 2018
  • The signal of space charge distribution measured in polymer insulating materials by the PEA has some noises due to the system circuits and the ringing phenomena in the sensor of PVDF and so on forth. It's magnitude mainly depends on the thickness of the insulation material, and it is also affected by the attenuation and dispersion when traveling in a dielectric material. In order to make it reliable, the correcting process for the signal is essential. In this study, we proposed the new deconvolution process on the measured signal of space charge distribution in the flat XLPE insulator, and developed a new signal processing algorithm. Using this, we could improve the reliability of the measured signal much and analyze the effects of space charge clearly in materials.

박 센서 배열에 따른 154kV XLPE 케이블의 부분방전 검출 특성 연구 (Partial Discharge Quality Measurement improvement of XLPE Cable of 154kV by new method of FSA)

  • 신동훈;양종석;;임종천;황두현;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.158-159
    • /
    • 2006
  • The system measuring the Partial discharge(PD) is very essential to investigate the hazard defects in the insulation systems of the high voltage engineering. We included two parts in this discussion; The proposed method of Foil Sensor Array and the normally used method m the practice. Firstly, it will be shown the improved sensitivity of our proposed FSA sensor compare with the existing normal foil sensor. And then, the linearity of detecting sensitivities of various kinds of FSA sensors such as $2{\times}2$, $2{\times}4$, $3{\times}3$ etc. using in our experiments, was shown. From the obtained results, we can see that FSA sensor is more sensitivity than normal foil sensor and the linear increment property of FSA sensitivities.

  • PDF