• Title/Summary/Keyword: XLPE cable

Search Result 316, Processing Time 0.031 seconds

A Study of the Charging Current Effect on Underground Distribution Line in Electric Railway (전철 지중배전선로의 충전전류보상에 관한 연구)

  • Kim, Yang-Su;Jang, Woo-Jin
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.214-218
    • /
    • 2008
  • Because on the high-tension underground distribution line of an electric railway high voltage XLPE Cable two or three circuits between railway stations with a standard as receiving transformer facilities are established at a $30km{\sim}50km$ interval, reactive power in which the phase of a current is larger than that of a voltage is supplied when trains are not working, so when there are no loading or low loading as night. Due to the long-distance trend of the underground distribution system on an alternating current railway distribution line, the terminal voltage of a transformer is over the standard voltage, and after all, commercial cycle overvoltage is continued. To solve this problem, the shunt reactor is installed in middle of power distribution lines to maintain receiver voltage meted under the allowance regulation through control of the reactive power. Also, in case that the thickness of single cable is over $60mm^2$ and length of line is about over 30km, a circuit breaker is broken by shorting shunt ability of charging current in excess of shunt current(31.5A.rms). Therefore, this thesis presents installing the location of shunt reactor for quantitative analysis by using optimum algorism for compensation and control of the charging current.

  • PDF

On-Line Cable Water-Tree Detection by the Analysis of Pre-Discharge Signals (미세 방전신호 분석을 통한 케이블 수(水)트리 활선 현장진단)

  • Chung, Sang-Jin;Kim, Young-Min
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.6-8
    • /
    • 2008
  • 배전케이블 수 트리 현상은 XLPE케이블의 고장을 초래하는 주요원인이다. 수 트리에 기인한 신호는 아주 미세하여 현장진단은 배경 잡음으로 인해 검출이 어렵다. 본 논문에서는 고주파특성이 우수한 L-C결합센서를 사용하여 방전신호를 측정하고 이를 주파수영역에서의 분석을 통해 현장에서 부분방전이 발생하기 훨씬 이전에 존재하는 미세신호(Pre-Discharge)를 검출하고 분석한 결과를 제시하였다. 케이블 내 수(水) 트리가가 존재하면 이것이 이종 절연물의 경계면 역할을 하석 서-지 임피던스의 차이로 인해 케이블 단자에서 발생하는 전기적 신호가 수 트리 지점에서 다수의 반사를 일으켜 그 잡음 수준을 높이는 역한을 하게 되는 것으로 알려져 있다. 만일 여러 개소에 수 트리가 존재하는 경우에는 그 배경잡음을 현저하게 높이는 결과를 보여주었다. 실험실에서 발생하는 미세 신호와 현장의 신호를 비교한 결과 아주 유사한 패턴이 있음이 파악되어 이 방법은 수 트리의 활선 진단이 가능함을 확인시켜 주었다.

  • PDF

A study on the improvement of indefiniteness in PRPDA by use of PSA (PSA를 이용한 PRPDA의 불명확성 개선에 대한 연구)

  • Lee, Ho-Keun;Kim, Jeong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.226-228
    • /
    • 2003
  • This paper deals with the improvement of indefiniteness in PRPDA(Phase Resolved Partial Discharge Analysis) through analyzing the relation between PRPDA and PSA(Pulse Sequence Analysis). For the analysis we adopted PD data from artificial defects in XLPE HV cable systems and performed PRPDA and PSA. As a results, we confirmed that PSA was more useful than PRPDA in classifying PD patterns with the degradation stages. Therefore, it is possible to improve the indefiniteness of PD pattern recognition using the relation between PRPDA and PSA.

  • PDF

The method to increase the ampacity of underground transmission cable (초고압 지중송전케이블 송전용량 증대방안)

  • Kim, Du-Jin;Kim, Hyeong-Ho;Yoon, Jong-Keong;Bae, Ju-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.373_374
    • /
    • 2009
  • 대도시 전력계통망을 구성하는 지중송전선로는 154kV, 345kV OF 및 XLPE 케이블로 구성되어 있으며, 국토개발 및 도심지의 확장에 따라 설비물량은 갈수록 증가되고 있다. 국내 전력케이블은 대용량화, 소규모화 등 지속적으로 기술개발이 추진되고 있으며, 케이블 및 전력구 온도를 실시간 감지하여 운영자에게 보여주는 감시시스템도 도입되어 안정적인 전력공급을 위한 기반도 구축되었다. 최근 설비량 증가 및 대기 온도상승으로 인한 케이블 송전용량의 제한을 해소하기 위해 국내 최초로 냉각시스템을 도입할 예정이다.

  • PDF

A study on Electrical Potential Characteristics of HDPE Mixed with EVA (HDPE/EVA혼합수지의 전기적 분포 특성에 관한 연구)

  • Jung, Eui-Hwan;Heo, Jun;Lee, Seung-Su;Lim, Kee-Joe;Lee, Hyung-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1447_1448
    • /
    • 2009
  • In this paper, each specimen blended at weight proportions of 80% HDPE to 20% EVA, 70% HDPE to 30% EVA, 60% HDPE to 40% EVA, and 50% HDPE to 50% EVA was manufactured respectively. The insulation performances of the proposed insulator were compared with conventional XLPE, main insulating material of CV cable on the basis of the investigation results of DC insulation performances. From the space charge density, electric field and potential profiles with raising DC voltage and time variation in HE82, distortion of electric field distribution was improved. As EVA mixed into the bulks acts as nucleation in crystallization process of HDPE, the size of spherulites became decreased and finally formed continuous network structure. Ultimately it resulted from extinction of space charge in the interfacial region of spherulites.

  • PDF

A comparison of the conventional LFPD and HFPD patterns by use of artificial (인위적인 결함을 이용한 기존의 저주파 부분방전과 고주파 부분방전의 패턴 비교 연구)

  • Choi, J.O.;Lee, J.S.;Lim, Y.S.;Kim, J.T.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1673-1675
    • /
    • 2001
  • In this paper, Partial Discharge(PD) patterns are compared by means of Low Frequency PD(LFPD, based on the IEC 270) and recently proposed High Frequency PD(HFPD). For this purpose, three different types of artificial defects are provided such as corona in air, void in epoxy insulator and needle defect in XLPE cable insulation. PD were generated from each defect and then detected respectively by two different methods such as LFPD and HFPD. As a result, remarkable resemblance in PD pattern for differ detecting method have been observed from each defect. Accordingly, it could be deduced that the pattern recognition by LFPD could be regarded as the reference for the investigations by HFPD.

  • PDF

Impurities of the Semiconductive Shield in the Power Distribution Cable (배전용 전력케이블의 반도전층에 함유되어 있는 불순물 분석)

  • Kim, S.J.;Song, I.K.;Kim, J.Y.;Han, J.H.;Suh, K.S.;Lee, C.R.;Lee, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1794-1796
    • /
    • 1996
  • In order to evaluate the soundness of 10 year service-aged XLPE-insulated 22.9 kV underground distribution cables, semiconductive shields have been characterized. The edge of insulation near the insulation shield shows a drastic decrease of OIT. Impurities such as Ca, Mg, Fe, Cu were detected in both conductor and insulation shields. Their concentrations at the insulation shield are much higher than those at the strand shield. All these facts suggest that the edge of insulation near the insulation shield is degraded considerably, which might be attributed to the oxidation reaction of insulation by a large amount of impurities in the insulation shield.

  • PDF

Defect Detection of 22.9kV Distribution Line based on the PD Detection (부분방전 검출을 이용한 22.9kV 배전케이블 실선로 결함 검출)

  • Lee, Jeon-Seon;Kim, Jung-Yoon;Kim, Seok-Jong;Lee, Dong-Geun;Seo, Kyung-Woon
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.53-55
    • /
    • 2004
  • 부분방전 검출을 이용한 XLPE 케이블 진단은 중간 및 종단 접속재의 계면에 존재하는 결합을 검출할 수 있는 가장 효과적인 방법으로 제시되고 있지만 현장의 큰 노이즈로 인하여 신뢰성 있는 진단이 쉽지 않다. 하지만 국내에서 많은 연구가 이루어진 송전케이블 진단 기술을 바탕으로 배전케이블 진단에 적용하여 종단접속부에서 발생된 부분방전을 성공적으로 검출하였고 해체 조사를 통하여 결함을 검출하였다. 본 논문은 참고문헌[1]에 발표한 논문에 연결되는 논문으로 전편은 2004년 2월 부분방전 검출사례를 보고한 논문이고 본 논문에서는 8월 계획정전을 통하여 문제된 접속함을 교체한 후 해체조사를 통하여 결함을 검출한 사례보고이다.

  • PDF

A Study on Neutral Conductor Improvement for 0.6/1kV XLPE insulated Power Cable (배전선로 가공인입 케이블 중성선 운영방법 개선에 관한 연구)

  • Zhang, Jeong-IL
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1473-1474
    • /
    • 2015
  • 0.6/1kV CV 전선은 저압 지중선용 또는 가공저압배전선로 및 복잡한 인입선 정비를 위한 가공인입 간선용으로 사용한다. CV 전선은 내열성이 높고 내약품성 및 내유성이 우수하며 시공에 따른 미관성이 우수하여 가공인입용으로 적용이 증가하는 추세이다.[10] 가공인입용 CV 전선내 전압선과 중성선 단면적은 동일하게 제작, 현장에 적용되고 있다. 본 논문에서는 3상4선식 0.6/1kV CV 전선을 가공인입선에 적용시 중성선의 단면적을 전압선 단면적보다 평균 47%를 축소 개발, 현장에 적용하여 최적으로 중성선을 운영하는 방안을 제시하였다.

  • PDF

Optimal Design to maximize the ampacity of transmission cable system in conduits (송전용량 극대화를 위한 지중송전케이블 최적 배치기준 정립)

  • Kim, Du-jin;Seo, chul-soo;Hong, Min-seok;Jeon, Chan-eon;Oh, Jang-man;Jo, Won-hyeong
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.435-436
    • /
    • 2015
  • 국내 도심지 전력계통망을 구성하고 있는 지중송전선로는 345kV, 154kV XLPE 케이블로 건설되고 있다. 도심지의 확장과 수요증가로 선로의 대용량화, 대도체화가 진행되고 있고, 송전용량 증대를 위한 신기술도 역시 지속 발전하고 있다. 새로운 신자재, 신공법이 아닌 케이블 재배치, 매설심도 조정 등 시스템 디자인을 통해 허용전류를 극대화하고, 경제적인 대용량 송전선로를 구축하기 위하여 연구한 송전케이블의 관로 최적시공방안을 소개하고자 한다.

  • PDF