• Title/Summary/Keyword: X8

Search Result 8,976, Processing Time 0.042 seconds

A Single Case Study of Cobb's Angle, Angle of Trunk Rotation (ATR), and Height Changes in Adolescent Idiopathic Scoliosis Patients following 12 Weeks of Wearing a 3D Fabric Brace (12주간의 3D패브릭 보조기 착용에 따른 청소년 특발성 척추측만증 환자의 Cobb's Angle, Angle of Trunk Rotation (ATR), 신장 변화의 단일사례 연구)

  • Sang-Gil Lee;Eun-Taek Oh;Ji-Eun Kang
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.2
    • /
    • pp.73-83
    • /
    • 2023
  • Objective: Adolescent idiopathic scoliosis patients make up 40% of all scoliosis patients, and it is likely to increase even more because of the increase in sitting times due to the pandemic. Method: The subject of this study was a 16-year-old female student. The Cobb's Angle at initial value was 42° at the thoracic and 33° at the lumbar. The subject's height was 161.6 cm, and the type of scoliosis was 3CL. The brace was built with fabric materials with the size information from the X-ray information and actual measurements. The brace was made for the adolescents to wear for a longer time by making them put pressure on the same pressure points of the existing braces. The subjects were required to wear the device for 16 hours every day for three months. Additional features to check the pressure and time were synchronized through an app for easier communication and management with the responsible investigator. Results: After wearing the 3D Fabric brace, Cobb's angle changed from 42° to 33° at the thoracic and 33° to 23° at the lumbar. The ATR changed from 9° to 8° at the thoracic and 11° to 6° at the lumbar. As a result, the changes in the ATR angle do relate to the decrease of Cobb's angle, which made the angle of scoliosis that is bent in a three-dimensional way improve, making the height of the subject increase from 161.6 cm to 163.5 cm. Conclusion: Through this study, developing a brace that is made in the form of the 3CL to align the strap direction and putting pressure on the proper pressure points makes Cobb's angle and the ATR smaller. This means that there is a positive effect on the changes in height. A brace made of light fabric material is a good brace to help treat adolescent idiopathic scoliosis. There was an opinion that it is more comfortable to wear than existing braces, but it seems necessary to conduct a quantitative study about the before and after of wearing the brace and a survey for Korean specific cases.

Deep Learning-Based Algorithm for the Detection and Characterization of MRI Safety of Cardiac Implantable Electronic Devices on Chest Radiographs

  • Ue-Hwan Kim;Moon Young Kim;Eun-Ah Park;Whal Lee;Woo-Hyun Lim;Hack-Lyoung Kim;Sohee Oh;Kwang Nam Jin
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1918-1928
    • /
    • 2021
  • Objective: With the recent development of various MRI-conditional cardiac implantable electronic devices (CIEDs), the accurate identification and characterization of CIEDs have become critical when performing MRI in patients with CIEDs. We aimed to develop and evaluate a deep learning-based algorithm (DLA) that performs the detection and characterization of parameters, including MRI safety, of CIEDs on chest radiograph (CR) in a single step and compare its performance with other related algorithms that were recently developed. Materials and Methods: We developed a DLA (X-ray CIED identification [XCID]) using 9912 CRs of 958 patients with 968 CIEDs comprising 26 model groups from 4 manufacturers obtained between 2014 and 2019 from one hospital. The performance of XCID was tested with an external dataset consisting of 2122 CRs obtained from a different hospital and compared with the performance of two other related algorithms recently reported, including PacemakerID (PID) and Pacemaker identification with neural networks (PPMnn). Results: The overall accuracies of XCID for the manufacturer classification, model group identification, and MRI safety characterization using the internal test dataset were 99.7% (992/995), 97.2% (967/995), and 98.9% (984/995), respectively. These were 95.8% (2033/2122), 85.4% (1813/2122), and 92.2% (1956/2122), respectively, with the external test dataset. In the comparative study, the accuracy for the manufacturer classification was 95.0% (152/160) for XCID and 91.3% for PPMnn (146/160), which was significantly higher than that for PID (80.0%,128/160; p < 0.001 for both). XCID demonstrated a higher accuracy (88.1%; 141/160) than PPMnn (80.0%; 128/160) in identifying model groups (p < 0.001). Conclusion: The remarkable and consistent performance of XCID suggests its applicability for detection, manufacturer and model identification, as well as MRI safety characterization of CIED on CRs. Further studies are warranted to guarantee the safe use of XCID in clinical practice.

A Three-Dimensional Deep Convolutional Neural Network for Automatic Segmentation and Diameter Measurement of Type B Aortic Dissection

  • Yitong Yu;Yang Gao;Jianyong Wei;Fangzhou Liao;Qianjiang Xiao;Jie Zhang;Weihua Yin;Bin Lu
    • Korean Journal of Radiology
    • /
    • v.22 no.2
    • /
    • pp.168-178
    • /
    • 2021
  • Objective: To provide an automatic method for segmentation and diameter measurement of type B aortic dissection (TBAD). Materials and Methods: Aortic computed tomography angiographic images from 139 patients with TBAD were consecutively collected. We implemented a deep learning method based on a three-dimensional (3D) deep convolutional neural (CNN) network, which realizes automatic segmentation and measurement of the entire aorta (EA), true lumen (TL), and false lumen (FL). The accuracy, stability, and measurement time were compared between deep learning and manual methods. The intra- and inter-observer reproducibility of the manual method was also evaluated. Results: The mean dice coefficient scores were 0.958, 0.961, and 0.932 for EA, TL, and FL, respectively. There was a linear relationship between the reference standard and measurement by the manual and deep learning method (r = 0.964 and 0.991, respectively). The average measurement error of the deep learning method was less than that of the manual method (EA, 1.64% vs. 4.13%; TL, 2.46% vs. 11.67%; FL, 2.50% vs. 8.02%). Bland-Altman plots revealed that the deviations of the diameters between the deep learning method and the reference standard were -0.042 mm (-3.412 to 3.330 mm), -0.376 mm (-3.328 to 2.577 mm), and 0.026 mm (-3.040 to 3.092 mm) for EA, TL, and FL, respectively. For the manual method, the corresponding deviations were -0.166 mm (-1.419 to 1.086 mm), -0.050 mm (-0.970 to 1.070 mm), and -0.085 mm (-1.010 to 0.084 mm). Intra- and inter-observer differences were found in measurements with the manual method, but not with the deep learning method. The measurement time with the deep learning method was markedly shorter than with the manual method (21.7 ± 1.1 vs. 82.5 ± 16.1 minutes, p < 0.001). Conclusion: The performance of efficient segmentation and diameter measurement of TBADs based on the 3D deep CNN was both accurate and stable. This method is promising for evaluating aortic morphology automatically and alleviating the workload of radiologists in the near future.

A Modified Length-Based Grading Method for Assessing Coronary Artery Calcium Severity on Non-Electrocardiogram-Gated Chest Computed Tomography: A Multiple-Observer Study

  • Suh Young Kim;Young Joo Suh;Na Young Kim;Suji Lee;Kyungsun Nam;Jeongyun Kim;Hwan Kim;Hyunji Lee;Kyunghwa Han;Hwan Seok Yong
    • Korean Journal of Radiology
    • /
    • v.24 no.4
    • /
    • pp.284-293
    • /
    • 2023
  • Objective: To validate a simplified ordinal scoring method, referred to as modified length-based grading, for assessing coronary artery calcium (CAC) severity on non-electrocardiogram (ECG)-gated chest computed tomography (CT). Materials and Methods: This retrospective study enrolled 120 patients (mean age ± standard deviation [SD], 63.1 ± 14.5 years; male, 64) who underwent both non-ECG-gated chest CT and ECG-gated cardiac CT between January 2011 and December 2021. Six radiologists independently assessed CAC severity on chest CT using two scoring methods (visual assessment and modified length-based grading) and categorized the results as none, mild, moderate, or severe. The CAC category on cardiac CT assessed using the Agatston score was used as the reference standard. Agreement among the six observers for CAC category classification was assessed using Fleiss kappa statistics. Agreement between CAC categories on chest CT obtained using either method and the Agatston score categories on cardiac CT was assessed using Cohen's kappa. The time taken to evaluate CAC grading was compared between the observers and two grading methods. Results: For differentiation of the four CAC categories, interobserver agreement was moderate for visual assessment (Fleiss kappa, 0.553 [95% confidence interval {CI}: 0.496-0.610]) and good for modified length-based grading (Fleiss kappa, 0.695 [95% CI: 0.636-0.754]). The modified length-based grading demonstrated better agreement with the reference standard categorization with cardiac CT than visual assessment (Cohen's kappa, 0.565 [95% CI: 0.511-0.619 for visual assessment vs. 0.695 [95% CI: 0.638-0.752] for modified length-based grading). The overall time for evaluating CAC grading was slightly shorter in visual assessment (mean ± SD, 41.8 ± 38.9 s) than in modified length-based grading (43.5 ± 33.2 s) (P < 0.001). Conclusion: The modified length-based grading worked well for evaluating CAC on non-ECG-gated chest CT with better interobserver agreement and agreement with cardiac CT than visual assessment.

Appendiceal Visualization on 2-mSv CT vs. Conventional-Dose CT in Adolescents and Young Adults with Suspected Appendicitis: An Analysis of Large Pragmatic Randomized Trial Data

  • Jungheum Cho;Youngjune Kim;Seungjae Lee;Hooney Daniel Min;Yousun Ko;Choong Guen Chee;Hae Young Kim;Ji Hoon Park;Kyoung Ho Lee;LOCAT Group
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.413-425
    • /
    • 2022
  • Objective: We compared appendiceal visualization on 2-mSv CT vs. conventional-dose CT (median 7 mSv) in adolescents and young adults and analyzed the undesirable clinical and diagnostic outcomes that followed appendiceal nonvisualization. Materials and Methods: A total of 3074 patients aged 15-44 years (mean ± standard deviation, 28 ± 9 years; 1672 female) from 20 hospitals were randomized to the 2-mSv CT or conventional-dose CT group (1535 vs. 1539) from December 2013 through August 2016. A total of 161 radiologists from 20 institutions prospectively rated appendiceal visualization (grade 0, not identified; grade 1, unsure or partly visualized; and grade 2, clearly and entirely visualized) and the presence of appendicitis in these patients. The final diagnosis was based on CT imaging and surgical, pathologic, and clinical findings. We analyzed undesirable clinical or diagnostic outcomes, such as negative appendectomy, perforated appendicitis, more extensive than simple appendectomy, delay in patient management, or incorrect CT diagnosis, which followed appendiceal nonvisualization (defined as grade 0 or 1) and compared the outcomes between the two groups. Results: In the 2-mSv CT and conventional-dose CT groups, appendiceal visualization was rated as grade 0 in 41 (2.7%) and 18 (1.2%) patients, respectively; grade 1 in 181 (11.8%) and 81 (5.3%) patients, respectively; and grade 2 in 1304 (85.0%) and 1421 (92.3%) patients, respectively (p < 0.001). Overall, undesirable outcomes were rare in both groups. Compared to the conventional-dose CT group, the 2-mSv CT group had slightly higher rates of perforated appendicitis (1.1% [17] vs. 0.5% [7], p = 0.06) and false-negative diagnoses (0.4% [6] vs. 0.0% [0], p = 0.01) following appendiceal nonvisualization. Otherwise, these two groups were comparable. Conclusion: The use of 2-mSv CT instead of conventional-dose CT impairs appendiceal visualization in more patients. However, appendiceal nonvisualization on 2-mSv CT rarely leads to undesirable clinical or diagnostic outcomes.

Transplantation of human umbilical cord mesenchymal stem cells optimized with IFN-γ is a potential procedure for modification of motor impairment in multiple sclerosis cases: a preclinical systematic review and meta-analysis study

  • Mohamad Mahdi Esmaeili Araghi;Amir Abdolmaleki;Hadi Esmaeili Gouvarchin Ghaleh;Bahman Jalali Kondori;Akbar Ghorbani Alvanegh;Mehrdad Moosazadeh Moghaddam;Seyed Javad Hosseini Nejad Anbaran
    • Anatomy and Cell Biology
    • /
    • v.57 no.3
    • /
    • pp.333-345
    • /
    • 2024
  • Stem cells transplantation (SCT) is known as a newfound strategy for multiple sclerosis (MS) treatment. Human umbilical cord mesenchymal stem cells (hUCMSCs) contain various regenerative features. Experimental autoimmune encephalomyelitis (EAE) is a laboratory model of MS. This meta-analysis study was conducted to assess the overall therapeutic effects of hUCMSCs on reduction of clinical score (CS) and restoration of active movement in EAE-induced animals. For comprehensive searching (in various English and Persian databases until May 1, 2024), the main keywords of "Experimental Autoimmune Encephalomyelitis", "Multiple Sclerosis", "Human", "Umbilical Cord", "Mesenchymal", and "Stem Cell" were hired. Collected data were transferred to the citation manager software (EndNote x8) and duplicate papers were merged. Primary and secondary screenings were applied (according to the inclusion and exclusion criteria) and eligible studies were prepared for data collection. CS of two phases of peak and recovery of EAE were extracted as the difference in means and various analyses including heterogeneity, publication bias, funnel plot, and sensitivity index were reported. Meta-analysis was applied by CMA software (v.2), P<0.05 was considered a significant level, and the confidence interval (CI) was determined 95% (95% CI). Six eligible high-quality (approved by ARRIVE checklist) papers were gathered. The difference in means of peak and recovery phases were -0.775 (-1.325 to -0.225; P=0.006; I2=90.417%) and -1.230 (-1.759 to -0.700; P<0.001; I2=93.402%), respectively. The overall therapeutic effects of SCT of hUCMSCs on the EAE cases was -1.011 (95% CI=-1.392 to -0.629; P=0.001). hUCMSCs transplantation through the intravenous route to the animal MS model (EAE) seems a considerably effective procedure for the alleviation of motor defects in both phases of peak and recovery.

MR T2 Map Technique: How to Assess Changes in Cartilage of Patients with Osteoarthritis of the Knee (MR T2 Map 기법을 이용한 슬관절염 환자의 연골 변화 평가)

  • Cho, Jae-Hwan;Park, Cheol-Soo;Lee, Sun-Yeob;Kim, Bo-Hui
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.298-307
    • /
    • 2009
  • By using the MR T2 map technique, this study intends, first, to measure the change of T2 values of cartilage between healthy people and patients with osteoarthritis and, second, to assess the form and the damage of cartilage in the knee-joint, through which this study would consider the utility of the T2 map technique. Thirty healthy people were selected based on their clinical history and current status and another thirty patients with osteoarthritis of the knee who were screened by simple X-ray from November 2007 to December 2008 were selected. Their T2 Spin Echo (SE hereafter) images for the cartilage of the knee joint were collected by using the T2 SE sequence, one of the multi-echo methods (TR: 1,000 ms; TE values: 6.5, 13, 19.5, 26, 32.5. 40, 45.5, 52). Based on these images, the changes in the signal intensity (SI hereafter) for each section of the cartilage of the knee joint were measured, which yielded average values of T2 through the Origin 7.0 Professional (Northampton, MA 01060 USA). With these T2s, the independent samples T-test was performed by SPSS Window version 12.0 to run the quantitative analysis and to test the statistical significance between the healthy group and the patient group. Closely looking at T2 values for each anterior and lateral articular cartilage of the sagittal plane and the coronal plane, in the sagittal plane, the average T2 of the femoral cartilage in the patient group with arthritis of the knee ($42.22{\pm}2.91$) was higher than the average T2 of the healthy group ($36.26{\pm}5.01$). Also, the average T2 of the tibial cartilage in the patient group ($43.83{\pm}1.43$) was higher than the average T2 in the healthy group ($36.45{\pm}3.15$). In the case of the coronal plane, the average T2 of the medial femoral cartilage in the patient group ($45.65{\pm}7.10$) was higher than the healthy group ($36.49{\pm}8.41$) and so did the average T2 of the anterior tibial cartilage (i.e., $44.46{\pm}3.44$ for the patient group vs. $37.61{\pm}1.97$ for the healthy group). As for the lateral femoral cartilage in the coronal plane, the patient group displayed the higher T2 ($43.41{\pm}4.99$) than the healthy group did ($37.64{\pm}4.02$) and this tendency was similar in the lateral tibial cartilage (i.e., $43.78{\pm}8.08$ for the patient group vs. $36.62{\pm}7.81$ for the healthy group). Along with the morphological MR imaging technique previously used, the T2 map technique seems to help patients with cartilage problems, in particular, those with the arthritis of the knee for early diagnosis by quantitatively analyzing the structural and functional changes of the cartilage.

  • PDF

Study on the Difference in Intake Rate by Kidney in Accordance with whether the Bladder is Shielded and Injection method in 99mTc-DMSA Renal Scan for Infants (소아 99mTc-DMSA renal scan에서 방광차폐유무와 방사성동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구)

  • Park, Jeong Kyun;Cha, Jae Hoon;Kim, Kwang Hyun;An, Jong Ki;Hong, Da Young;Seong, Hyo Jin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.27-31
    • /
    • 2016
  • Purpose $^{99m}Tc-DMSA$ renal scan is a test for the comparison of the function by imaging the parenchyma of the kidneys by the cortex of a kidney and by computing the intake ratio of radiation by the left and right kidney. Since the distance between the kidneys and the bladder is not far given the bodily structure of an infant, the bladder is included in the examination domain. Research was carried out with the presumption that counts of bladder would impart an influence on the kidneys at the time of this renal scan. In consideration of the special feature that only a trace amount of a RI is injected in a pediatric examination, research on the method of injection was also carried out concurrently. Materials and Methods With 34 infants aged between 1 month to 12 months for whom a $^{99m}Tc-DMSA$ renal scan was implemented on the subjects, a Post IMAGE was acquired in accordance with the test time after having injected the same quantity of DMSA of 0.5mCi. Then, after having acquired an additional image by shielding the bladder by using a circular lead plate for comparison purposes, a comparison was made by illustrating the percentile of (Lt. Kidney counts + Rt. Kidney counts)/ Total counts, by drawing the same sized ROI (length of 55.2mm X width of 70.0mm). In addition, in the format of a 3-way stopcock, a Heparin cap and direct injection into the patient were performed in accordance with RI injection methods. The differences in the count changes in accordance with each of the methods were compared by injecting an additional 2cc of saline into the 3-way stopcock and Heparin cap. Results The image prior to shielding of the bladder displayed a kidney intake rate with a deviation of $70.9{\pm}3.18%$ while the image after the shielding of the bladder displayed a kidney intake rate with a deviation of $79.4{\pm}5.19%$, thereby showing approximately 6.5~8.5% of difference. In terms of the injection method, the method that used the 3-way form, a deviation of $68.9{\pm}2.80%$ prior to the shielding and a deviation of $78.1{\pm}5.14%$ after the shielding were displayed. In the method of using a Heparin cap, a deviation of $71.3{\pm}5.14%$ prior to the shielding and a deviation of $79.8{\pm}3.26%$ after the shielding were displayed. Lastly, in the method of direct injection into the patient, a deviation of $75.1{\pm}4.30%$ prior to the shielding and a deviation of $82.1{\pm}2.35%$ after the shielding were displayed, thereby illustrating differences in the kidney intake rates in the order of direct injection, a Heparin cap and the 3-way methods. Conclusion Since a substantially minute quantity of radiopharmaceuticals is injected for infants in comparison to adults, the cases of having shielded the bladder by removing radiation of the bladder displayed kidney intake rates that are improved from those of the cases of not having shielded the bladder. Although there are difficulties in securing blood vessels, it is deemed that the method of direct injection would be more helpful in acquisition of better images since it displays improved kidney intake rate in comparison to other methods.

  • PDF

Changes of Polyamine Metabolism and Delayed Neuronal Degeneration of Hippocampus after Transient Cerebral Ischemia in Mongolian Gerbils (뇌허혈 손상에 있어서 Polyamine 대사의 변동이 해마신경세포의 지연성괴사에 미치는 효과에 관한 연구)

  • Shin, Kyung-Ho;Shin, Hwa-Jung;Lee, Young-Jae;Kim, Hyung-Gun;Choi, Sang-Hyun;Chun, Yeon-Sook;Chun, Boe-Gwun
    • The Korean Journal of Pharmacology
    • /
    • v.32 no.3
    • /
    • pp.323-334
    • /
    • 1996
  • Male Mongolian gerbils $(60{\sim}80g)$ were given DL-difluoromethylornithine (DFMO; 250mg/kg, ip) and methylglyoxal bis(guanylhydrazone) (MGBG; 50 mg/k, ip), respectively, 1 h prior to transient (7 min) occlusion of bilateral common carotid arteries (OBC7) and a daily dose of one of them for 6 days after recirculation, and the polyamine contents, activities of ornithine and S-adenosylmethionine decarboxylases (ODC and SAM-DC), and light microscopic findings of the hippocampus were evaluated. The hippocampal putrescine (PT) levels of the control gerbils treated with saline (STGr), markedly increased after OBC7, showing a peak level at 24 h after recirculation. The peak PT level was reduced in DFMO treated gerbils (DTCr) and in MGBG treated gerbils (MTGr). And 7 days after recirculation, the PT level of DTGr was decreased to about 75% of the PT level in the sham operated group (nonTGr) and to about 55% of the STGr level, respectively. The hippocampal spermidine (SD) level of STGr tended to decline, showing the lowest value at 8 h after recirculation. But the spermidine (SD) level of DTGr was somewhat higher at 8 h after OBC7 than those of STGr and MTGr The hippocampal spermine (SM) levels of all the experimental groups were little changed for 7 days after OBC. OBC7 markedly increased the hippocampal ODC activity. reaching a maximum (about 3 times higher than preischemic level) at 8 h and rapidly recovered to the control value by 24 h in STGr gerbils, and the OBC7-induced increase of ODC activity was significantly attenuated by DFMO or MGBG treatment. Whereas OBC7 induced a rapid decrease of the hippocampal SAMDC activity follwed by gradual recovery to the preischemic level, and the decrease of the SAMDC activity was slightly attenuated by DFMO or MGBG treatment. 7 Days after OBC7 the histological finding of the hippocampal complex stained with cresyl violet showed an extensive delayed neuronal damage in the CA1 region and to a lesser extent, in the dentate gyrus, sparing the CA3 region. And the neuronal death was aggevated by DFMO but significantly attenuated by MGBG. The immunochemical reactivity of hippocampus to anti-GFAP antibody was significantly increased in the CA1 region and to a lesser extent, in the dentate gyrus 7 days after OBC7, but was little changed in the CA3. And the increase of the anti-GFAP immunoreactivity was moderately enhanced by DFMO and significantly suppressed by MGBG. These results suggest that the polyamine metabolism may play a modulatory role in the ischemic brain damage.

  • PDF

Postoperative Radiation Therapy for Chest Wall Invading pT3N0 Non-small Cell Lung Cancer: Elective Lymphatic Irradiation May Not Be Necessary (흉벽을 침범한 pT3N0 비소세포폐암 환자에서 수술 후 방사선치료)

  • Park, Young-Je;Ahn, Yong-Chan;Lim, Do-Hoon;Park, Won;Kim, Kwan-Min;Kim, Jhingook;Shim, Young-Mog;Kim, Kyoung-Ju;Lee, Jeung-Eun;Kang, Min-Kyu;Nam, Hee-Rim;Huh, Seung-Jae
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.253-260
    • /
    • 2003
  • Purpose: No general consensus has been reached regarding the necessity of postoperative radiation therapy (PORT) and the optimal techniques of its application for patients with chest wall invasion (pT3cw) and node negative (NO) non-small cell lung cancer (NSCLC). We retrospectively analyzed the PT3cwN0 NSCLC patients who received PORT because of presumed inadequate resection margin on surgical findings. Materials and Methods: From Aug. 1994 till June 2000, 21 pT3cwN0 NSCLC patients received PORT at Samsung Medical Center; all of whom underwent curative on-bloc resection of the primary tumor plus the chest wall and regional lymph node dissection. PORT was typically stalled 3 to 4 weeks after operation using 6 or 10 MV X-rays from a linear accelerator. The radiation target volume was confined to the tumor bed plus the immediate adjacent tissue, and no regional lymphatics were included. The planned radiation dose was 54 Gy by conventional fractionation schedule. The survival rates were calculated and the failure patterns analyzed. Results: Overall survival, disease-free survival, loco-regional recurrence-free survival, and distant metastases-free survival rates at 5 years were 38.8$\%$, 45.5$\%$, 90.2$\%$, and 48.1$\%$, respectively. Eleven patients experienced treatment failure: six with distant metastases, three with intra-thoracic failures, and two with combined distant and intra-thoracic failures. Among the five patients with intra-thoracic failures, two had pleural seeding, two had in-field local failures, and only one had regional lymphatic failure in the mediastinum. No patients suffered from acute and late radiation side effects of RTOG grade 3 or higher. Conclusion: The strategy of adding PORT to surgery to improve the probability, not only of local control but also of survival, was justified, considering that local control was the most important component in the successful treatment of pT3cw NSCLC patients, especially when the resection margin was not adequate. The incidence and the severity of the acute and late side effects of PORT were markedly reduced, which contributed to improving the patients' qualify of life both during and after PORT, without increasing the risk of regional failures by eliminating the regional lymphatics from the radiation target volume.