• Title/Summary/Keyword: X8

Search Result 8,977, Processing Time 0.039 seconds

A Study on the Soil Contamination(Maps) Using the Handheld XRF and GIS in Abandoned Mining Areas (휴대용 XRF와 GIS를 이용한 폐광산 지역의 토양오염에 관한 연구)

  • Lee, Hyeon-Gyu;Choi, Yo-Soon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.3
    • /
    • pp.195-206
    • /
    • 2014
  • In this study, soil contamination maps related to Cu and Pb were created at the Busan abandoned mine in Korea using a handheld X-Ray Fluorescence(XRF) and Geographic Information Systems(GIS). Hydrological analysis was performed using the Digital Elevation Model(DEM) of the study area to identify the flow directions of surface runoff where pollutants can be dispersed from the soil contamination sources. 24 locations for measuring the soil contamination related to Cu and Pb were selected by considering the result of hydrological analysis. The results measured at the 24 locations using the handheld XRF showed that the highest value of Cu contamination is 8,255ppm and that of Pb is 2,146ppm. The field investigation data were entered into ArcGIS software, and then soil contamination maps regarding Cu and Pb with a 5m grid-spacing were created after performing spatial interpolations using the ordinary kriging method. As a result, we could know that high concentrations of Cu and Pb are presented at the waste and tailings dumps around the abandoned mine openings. This study also showed that the handheld XRF and GIS can be utilized to create soil contamination maps related to Cu and Pb in the field.

The Inelastic Behavior of High Strength Reinforced Concrete Tall Walls (고강도 철근콘크리트 고층형 내력벽의 비탄성 거동에 관한 실험 연구)

  • 윤현도;정학영;최창식;이리형
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.3
    • /
    • pp.139-148
    • /
    • 1995
  • The test results from three one fourth scale models using high strength Reinforced Concrete $f_x=704\;kg/cm^2,\;f_y=5.830\;kg/cm^2$ are presented. Such specimens are considered to represent the critical 3 storics of 60-story tall building of a structural wall system in area of high seismicity respectively. They are tested under inplane vertical and horizontal loading. The main varlable is the level of axial stress. The amounts of vertical and horizontal reinforcement are identical for the three walls testcd. The cross-section of all walls is barbell shape. The aspectratio($h_w/I_w$) of test specimen is 1.8. The aim of the study is to investigate the effects of levels of applied axial stresses on the inelastic behavior of high-strength R /C tall walls. Experimental results of high strength R /C tall walls subjected to axial load and simulated sels rnic loading show that it is possible to insure a ductlle dominant performance by promotmg flex ural yielding of vertical reinforcement and that axial stresses within $O.21f_x$ causes an increase in horizontal load-carrying capacity, initial secant st~ffness characteristics, but an decrease in displacement ductility. energy dissipation index and work damage index of high strength K /C tall walls

A Design and Fabrication of the X-Band Transmit/Receive Module for Active Phased Array SAR Antennas (능동 위상 배열 SAR 안테나를 위한 X-대역 송수신 모듈의 설계 및 제작)

  • Chong, Min-Kil;Kim, Sang-Keun;Na, Hyung-Gi;Lee, Jong-Hwan;Yi, Dong-Woo;Baik, Seung-Hun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.10
    • /
    • pp.1050-1060
    • /
    • 2009
  • In this paper, a X-Band T/R-module for SAR(Synthetic Aperture Radar) systems based on active phased array antennas is designed and fabricated. The T/R modules have a and width of more than 800 MHz centered at X-Band and support dual, switched polarizations. The output power of the module is 7 watts over a wide bandwidth. The noise figure is as low as 3.9 dB. Phase and amplitude are controlled by a 6-bit phase shifter and a 6-bit digital attenuator, respectively. Further the fabricated T/R module has est and calibration port with directional coupler and power divider. Highly integrated T/R module is achieved by using LTCC(Low Temperature Co-fired Ceramic) multiple layer substrate. RMS gain error is less than 0.8 dB max. in Rx mode, and RMS phase error is less than $4^{\circ}$ max. in Rx/Tx phase under all operating frequency band, or the T/R module meet the required electrical performance m test. This structure an be applied to active phase array SAR Antennas.

Feasibility Study of Parallel- Plate Detector Using Dielectric film for 6 MV X-ray (6MV X-선 검출특성 조사를 위하여 유전체 필름을 이용하여 제작한 평행판 검출기의 유용성)

  • 조문준;김용은;이병용;김정기;임상욱;김현수;김기환
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.105-111
    • /
    • 2004
  • The parallel plate detector with dielectric film for dosimetry was designed to measure detection characteristic of 6 MV X-ray with medical linear accelerator. PTFE film was inserted into FEP films that are made by two one-side metal coated materials for ion source. The thicknesses of PTFE dielectric film was 100 ${\mu}{\textrm}{m}$ and the thickness of FEP dielectric film was 100 ${\mu}{\textrm}{m}$, respectively. This detector was fixed by two acrylic plate for physical hardness ad geometrical consistency. The geometrical condition for measurement with parallel-plate for detector was below; SSD=100 cm and the 5 cm depth between detector and phantom surface The major parameter of detector characteristics such as zero drift current, leakage current, charge response by applied voltage, reproducibility, linearity, TMR measurement, dose rate effect were measured. The zero drift currents are 8.3 pA and leakage currents are 10 pA. The charge response of applied voltage is showing linearity in 414 voltage. The measurement deviation of reproducibility in this detector is within 1% for dose and the linearity of applied dose shows in this detector. The TMR curves in phantom between this parallel plate detector and reference detector are matched within 3% deviation from maximum dose depth to 7.5 cm depth. It is considered that this dosimetric system is satisfactory for the purpose of the constancy check of the 6 MV x-ray from medical linear accelerator.

  • PDF

Study on the Behavior of Curved Track in Honam High-Speed Line considering the Running Performanace for HEMU 430-X (HEMU 430-X 주행특성을 고려한 호남고속철도 곡선궤도구조의 거동연구)

  • Kang, Yun-Suk;Um, Ki-Young;Kim, Seog-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.8
    • /
    • pp.4068-4076
    • /
    • 2013
  • The wheel-rail interaction forces are influenced by the velocity of vehicle, wheel load, alignment (curve radius, cant etc). For the safety of track structure, it is required to evaluate the influences for track and influential factors. Recently, the HEMU 430-X, which was developed by Next Generation High-Speed Rail Development R&D Project, achieved 421.4km/h in a test run of Daegu.Busan section of the Gyeongbu high speed rail on March in 2013. In the case of additional speed-up test on Test-Bed Section(Gongju.Jeongeup: KP 100~128km Osong starting point), the analysis of track forces is required for outer rail by the increase of dynamic force and centrifugal force of vehicle. In this paper, the vehicle speed variation on HSL line is evaluated by TPS analysis considering the tractive effort of HEMU 430-X, tested running resistance and alignment of Honam HSR. And the track forces are evaluated by centrifugal force and impact factor on curved track.

Perception of Risk and Using Status of Hand-Held Dental X-Ray Unit (이동형 치과 X선 발생장치 사용실태와 위험지각)

  • Han, Gyeong-Soon
    • Journal of dental hygiene science
    • /
    • v.14 no.4
    • /
    • pp.442-447
    • /
    • 2014
  • The aim of this study was to analyze perception of risk and using status of hand-held dental x-ray unit among dental hygienists in metropolitan area. This research was based on perception of risk and using status of hand-held dental x-ray unit survey in 257 dental hygienists from July 7 to 31, 2014. Data were analyzed with t-test, one way ANOVA, and multivariable logistic regression analysis using SPSS Windows 21.0 program and significance level was set at p<0.05. The hand-held dental x-ray unit to cover all type patients was 24.8%. The 62.6% of patients and 81.3% of operator doesn't wear lead apron, the experience rate of radiation education was 40.1%. The average of risk perception was 3.08 points. The associated factors of risk perception were career, number of radiation exposure per day, and possession of fixed x-ray unit. The increased of accumulated dose when the occupationally exposed work continues, it is necessary to effort of defense against dental radiation.

Characteristics of Chaff Echoes Observed by X-band Dual Polarization Radar (X-밴드 이중편파레이더에서 관측된 채프에코의 특성)

  • Seo, Eun-Kyoung;Park, Sora;Nam, Kyung-Yeub;Heo, Sol-Ip
    • Journal of the Korean earth science society
    • /
    • v.34 no.1
    • /
    • pp.1-12
    • /
    • 2013
  • To effectively remove chaff echoes, which are often misidentified as precipitation echoes on weather radars, this study examines the relationship between the radar reflectivity and each of dual polarimetric parameters. The dual polarimetric parameters are collected only for the echo areas identified as chaff echoes on the NIMR X-band dual polarization radar. Overall, the polarimetric parameters (i.e., reflectivity, differential reflectivity, cross correlation coefficient, standard deviation of differential reflectivity and specific differential phase) for chaff echoes have a wider range of values than those for precipitation echoes and the chaff filaments tend to be horizontally oriented to radar beams. There appears to be a considerable overlap in the cross correlation coefficient range of chaff and precipitation echoes since some precipitation echoes have cross correlation coefficient lower than 0.8. Therefore, although the cross correlation coefficient is known to be a good variable in identifying and separating chaff echoes from precipitation echoes, it is suggested that additional care should be taken when using the cross correlation coefficient solely in removing chaff echoes.

Economic Injury Level of the Striped Cabbage Flea Beetle, Phyllotreta striolata (Coleoptera: Chrysomelidae), on Chinese Cabbage (시설배추에서 벼룩잎벌레의 경제적 피해수준 설정)

  • Lee, Young Su;Kim, Jin Young;Hong, Soon Sung;Park, Hong Hyun
    • Korean journal of applied entomology
    • /
    • v.53 no.2
    • /
    • pp.93-96
    • /
    • 2014
  • This study was conducted to determine the economic injury levels and control thresholds for the striped cabbage flea beetle, Phyllotreta striolata (Coleoptera: Chrysomelidae), on Chinese cabbage at two different planting times. The number of inoculated adults per 10 cabbages was 0, 2, 4, 8, and 16 at the early developmental stage of the cabbage5 days after planting) and 0, 10, 20, 30, and 40 at the middle developmental stage (30 days after planting). Damages to the leaves at the first inoculation were 2.5-21.1% and at the second inoculation were 1.8-26.3% after harvesting. The linear relationships between population density and yield reduction were as follows: Y = 1.3475X + 2.135 ($R^2$ = 0.8699) at the early developmental stage and Y = 0.703X - 1.78 ($R^2$ = 0.966) at the middle developmental stage. On the basis of these results, the economic injury levels caused 5% loss of yield; there were 2.1 adults per 10 Chinese cabbage at the early developmental stage and 9.6 adults per 10 Chinese cabbage at the middle developmental stage.

A Study on the Physical Characteristics of Photoconductors for Photon Counting based X-ray Sensor Application (광계수형 기반의 X선 영상센서 적용을 위한 광도전체 물성 연구)

  • Park, Ji Koon;Noh, Si Cheol;Choi, Il Hong;Jung, Bong Jae;Kang, Sang Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.423-428
    • /
    • 2014
  • Digital X-ray imaging devices using a TFT based flat panel array has been used in medical field. But, recently, lots of research on the photon counting sensor has been reported. In this study, we evaluated the physical properties of the photoconductor by suggesting the standard and testing method for quantitative performance evaluation of photon counting x-ray imaging sensor. First, we measured the leakage current and the sensitivity of photon counting x-ray imaging sensor and we evaluated the characteristic of rising time for determining the signal shaping time. In addition, the set-up study was conducted on the basis of the IEC 62220-1-2 recommendations to define the number of incident photons per unit area. And the efficiency of the charge collection was also evaluated. As a result, the characteristic was measured as $200pA/mm^2$ of the leakage current, $7{\mu}C/cm^2R $ of the X-ray sensitivity, and $0.765{\mu}s$ of the rising time.

Sterilization of Yakju(Rice Wine) Using a Batch-type High Voltage Pulsed Electric Field System (고전장펄스를 이용한 약주의 회분식 살균)

  • Kim, Su-Yeon;Park, Young-Seo;Mok, Chul-Kyoon
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.1247-1253
    • /
    • 1999
  • Yakju(rice wine) was sterilized with high-voltage pulses of short time on a batch pulsed electric field(PEF) system. The initial microbial counts of Yakju were 7.52 X $10^4\;CFU/mL$ for total aerobes, 2.20 X $10^4\;CFU/mL$ for lactic acid bacteria and 7.08 X $10^4\;CFU/mL$ for yeasts. The pH, acidity and electric conductivity of Yakju were 3.36, 0.462% and 1.24 mS/cm, respectively. Yakju was treated with 2-250 of pulses exponential-wave formed electric pulses under the field strength of 12.5-25 kV/cm. The critical strengths of the electrical field for the sterilization of Yakju were 7.5 kV/cm for total aerobes, 8.5 kV/cm for lactic acid bacteria and 6.5 kV/cm for yeasts. Logarithmic survival rates decreased linearly at low pulse number, but curvilinearly at high pulse number. The PEF sterilization kinetics of Yakju could be analysed by In s = In A-k In (n) and the sterilization rate constant increased with electric field strength and the size of target microorganisms. No changed in pH, acidity, and the growth of microorganisms were found in the PEF treated Yakju during the storage for 6 weeks at both $4^{\circ}C$ And $30^{\circ}C$.

  • PDF