• Title/Summary/Keyword: X-ray visualization

Search Result 65, Processing Time 0.023 seconds

A Case of Tuberculous Meningoencephalitis Presenting as Prominent Psychotic Features (현저한 정신증상으로 발현된 결핵성 뇌수막뇌염 1예)

  • Yu, Hyun-Jung;Oh, Jee-Young;Kim, Jee-Hyun;Kim, Jung-Eun;Park, Kee-Duk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.6
    • /
    • pp.603-608
    • /
    • 2001
  • Intracranial vasculitis is a rare and disastrous complication of tuberculous meningitis if not treated properly. Focal neurologic deficits according to the vessels involved are common manifestation. Here, we report a 29-year-old man who suffered abrupt, bizarre behavioral changes caused by vasculitis complicating tuberculous meningoencephalitis. The diagnosis of tuberculous meningitis is based upon both the CSF findings and a chest X-ray. His systemic symptoms disappeared by after being administered antituberculous medication but various psychotic features such as hypersomnia, hyperphagia and aggressive behavior continued. A brain MRI showed multiple small parenchymal tuberculous nodules, and the brain MR angiography revealed a narrowing of the proximal middle cerebral arteries and a reduced visualization of the cerebral vessels, suggesting widespread vasculitis. Intravenous dexamethasone successfully ameliorated his behavioral changes. In addition both the follow up brain MRI and angiography showed a normalization of the previous findings.

  • PDF

Particle loading as a design parameter for composite radiation shielding

  • Baumann, N.;Diaz, K. Marquez;Simmons-Potter, K.;Potter, B.G. Jr.;Bucay, J.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3855-3863
    • /
    • 2022
  • An evaluation of the radiation shielding performance of high-Z-particle-loaded polylactic acid (PLA) composite materials was pursued. Specimens were produced via fused deposition modeling (FDM) using copper-PLA, steel-PLA, and BaSO4-PLA composite filaments containing 82.7, 75.2, and 44.6 wt% particulate phase contents, respectively, and were tested under broad-band flash x-ray conditions at the Sandia National Laboratories HERMES III facility. The experimental results for the mass attenuation coefficients of the composites were found to be in good agreement with GEANT4 simulations carried out using the same exposure conditions and an atomistic mixture as a model for the composite materials. Further simulation studies, focusing on the Cu-PLA composite system, were used to explore a shield design parameter space (in this case, defined by Cu-particle loading and shield areal density) to assess performance under both high-energy photon and electron fluxes over an incident energy range of 0.5-15 MeV. Based on these results, a method is proposed that can assist in the visualization and isolation of shield parameter coordinate sets that optimize performance under targeted radiation characteristics (type, energy). For electron flux shielding, an empirical relationship was found between areal density (AD), electron energy (E), composition and performance. In cases where ${\frac{E}{AD}}{\geq}2MeV{\bullet}cm{\bullet}g^{-1}$, a shield composed of >85 wt% Cu results in optimal performance. In contrast, a shield composed of <10 wt% Cu is anticipated to perform best against electron irradiation when ${\frac{E}{AD}}<2MeV{\bullet}cm{\bullet}g^{-1}$.

Micro-computed tomography for assessing the internal and external voids of bulk-fill composite restorations: A technical report

  • Tosco, Vincenzo;Monterubbianesi, Riccardo;Furlani, Michele;Giuliani, Alessandra;Putignano, Angelo;Orsini, Giovanna
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.303-308
    • /
    • 2022
  • Purpose: This technical report aims to describe and detail the use of micro-computed tomography for a reliable evaluation of the bulk-fill composite/tooth interface. Materials and Methods: Bulk-fill composite restorations in tooth cavities were scanned using micro-computed tomography to obtain qualitatively and quantitatively valuable information. Two-dimensional information was processed using specific algorithms, and ultimately a 3-dimensional (3D) specimen reconstruction was generated. The 3D rendering allowed the visualization of voids inside bulk-fill composite materials and provided quantitative measurements. The 3D analysis software VG Studio MAX was used to perform image analysis and assess gap formation within the tooth-restoration interface. In particular, to evaluate internal adaptation, the Defect Analysis addon module of VG Studio Max was used. Results: The data, obtained with the processing software, highlighted the presence and the shape of gaps in different colours, representing the volume of porosity within a chromatic scale in which each colour quantitatively represents a well-defined volume. Conclusion: Micro-computed tomography makes it possible to obtain several quantitative parameters, providing fundamental information on defect shape and complexity. However, this technique has the limit of not discriminating materials without radiopacity and with low or no filler content, such as dental adhesives, and hence, they are difficult to visualise through software reconstruction.

Measurement of S1 foramen depth for ultrasound-guided S1 transforaminal epidural injection

  • Ye Sull Kim;SeongOk Park;Chanhong Lee;Sang-Kyi Lee;A Ram Doo;Ji-Seon Son
    • The Korean Journal of Pain
    • /
    • v.36 no.1
    • /
    • pp.98-105
    • /
    • 2023
  • Background: Ultrasound-guided first sacral transforaminal epidural steroid injection (S1 TFESI) is a useful and easily applicable alternative to fluoroscopy or computed tomography (CT) in lumbosacral radiculopathy. When a needle approach is used, poor visualization of the needle tip reduces the accuracy of the procedure, increasing its difficulty. This study aimed to improve ultrasound-guided S1 TFESI by evaluating radiological S1 posterior foramen data obtained using three-dimensional CT (3D-CT). Methods: Axial 3D-CT images of the pelvis were retrospectively analyzed. The radiological measurements obtained from the images included 1st posterior sacral foramen depth (S1D, mm), 1st posterior sacral foramen width (S1W, mm), the angle of the 1st posterior sacral foramen (S1A, °), and 1st posterior sacral foramen distance (S1ds, mm). The relationship between the demographic factors and measured values were then analyzed. Results: A total of 632 patients (287 male and 345 female) were examined. The mean S1D values for males and females were 11.9 ± 1.9 mm and 10.6 ± 1.8 mm, respectively (P < 0.001); the mean S1A 28.2 ± 4.8° and 30.1 ± 4.9°, respectively (P < 0.001); and the mean S1ds, 24.1 ± 2.9 mm and 22.9 ± 2.6 mm, respectively (P < 0.001); however, the mean S1W values were not significantly different. Height was the only significant predictor of S1D (β = 0.318, P = 0.004). Conclusions: Ultrasound-guided S1 TFESI performance and safety may be improved with adjustment of needle insertion depth congruent with the patient's height.

Clinical Review of Pediatric Adenoviral Lower Respiratory Infection (아데노바이러스에 의한 소아 하기도 감염에 대한 임상적 고찰)

  • Son, Jin-A;Lee, Sang-Il;Lee, Nam-Young;Kim, Jung-Hee
    • Pediatric Infection and Vaccine
    • /
    • v.3 no.2
    • /
    • pp.154-162
    • /
    • 1996
  • Purpose : Adenoviruses(Ad) have been shown to play an important role in the etiology of severely acute respiratory diseases, particulary in infants and young children, and the occurrence of fatal outcome and chronic pulmonary sequelae in association with adenoviral infection has been a cause of great interest and concern. This report presents the resul of a retrospective analysis on 30 cases of lower respiratory infection from which adenovirus was isolated. Patients & Methods : The 30 patients in this study represent all detected cases of adenovial infection out of 240 children who were admitted to Sang Sung Medical Center between February to June 1996 showing signs and symptoms of lower respiratory tract infection. The diagnosis of adenovirus infection was based on microscopic visualization of typical cytopathic effect in HEp-2 tissue culture and used monoclonal Ab with nasopharyngeal aspiration. Results : The male/female ratio was 2:1 and the majority of age range was below 36months. Clinical diagnoses in all 30 patients were pneumonia(n=21), bronchitis and Bronchiolitis(n=5) and ARDS(n=4). We recieved the most of patients in the month of May. The chief complaints were fever(93.3%) and cough(80%) and extrapulmonary symptoms were diarrhea(n=5), seizure(n=4), abdominal pain(n=1). The mean duration of fever was $11.95{\pm}6.54$days. Physical examination on admission were crackles(73.3%), coarse breathing sounds(60%), hepatosplenomegaly(33.3%), decreased brething sounds(30%). In WBC counts, 8cases were below $4000/mm^3$ and 14 cases were above $10,000/mm^3$. In platelets counts, 4cases were below $150,000/mm^3$ and 10 cases were above $450,000/mm^3$. 21 cases were above 1 in CRP. GOT and GPT were abnormal in some cases. Chest X-ray revealed diffuse pulmonary infiltration(n=15), pleural effusion(n=6), consolidation(n=4) and hyperaeration(n=3). Seven patients were treated at the peditric intensive care unit with respiratory support and high dose of gammaglobulin. However, one patients died even through he was treated with NO ventilation and high frequency ventilation. Conclusion : Those with adenoviral pneumonia and respiratory infection having long fever duration and symptoms like bacterial pneumonia must be carefully differentiated in order to provide proper treatement and preventive measures due to possible fatal outcome.

  • PDF