• Title/Summary/Keyword: X-ray target

Search Result 470, Processing Time 0.031 seconds

Fabrication and Characterization of ZnGa2O4 Phosphor Target (ZnGa2O4 형광체 타겟의 제작 및 특성분석)

  • Kim, Yong-Chun;Hong, Beom-Joo;Kwon, Sang-Jik;Kim, Kyung-Hwan;Park, Yong-Seo;Choi, Hyung-Wook
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.12
    • /
    • pp.1347-1351
    • /
    • 2004
  • The ZnGa$_2$O$_4$ phosphor target was synthesized through solid-state reactions as calcine and sintering temperature in order to deposit ZnGa$_2$O$_4$ Phosphor thin film by rf magnetron sputtering system. The x-ray diffraction patterns of ZnGa$_2$O$_4$ phosphor target showed the position of (311) main peak. The cathodoluminescence(CL) spectrums of ZnGa$_2$O$_4$ phosphor target showed main peak of 370 nm to 400 nm, and maximum intensity at the calcine temperature of $700^{\circ}C$ and sintering temperature of 130$0^{\circ}C$. It was possible to prepare The ZnGa$_2$O$_4$ phosphor thin film with synthesized ZnGa$_2$O$_4$ phosphor target and The prepared ZnGa$_2$O$_4$ phosphor thin film showed the position of (311) main peak.

Effects of laser polarization on hot electron emission in femtosecond laser-plasmas

  • Zhang, J.;Chen, L.M.;Teng, H.;Liang. T.J.;Zhao, L.Z.;Wei, Z.Y.
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.98-102
    • /
    • 2001
  • Effects of laser polarization were studied on behaviors of fast electrons produced from an aluminum target irradiated by a solid target irradiated by obliquely incident laser pulses at Bx10$\^$15/ W/cm$^2$. Jet emission of outgoing fast electrons collimated in the polarization direction was observed for the s-polarized laser irradiation, whereas for the p-polarized irradiation, very directional emission of outgoing fast electrons was found close to the normal direction of the target. The behaviors of in-going fast electrons into the target for s- and p-polarized irradiation were also investigated by observing x-ray Bremsstrahlung radiation at the backside of the target.

  • PDF

Design of a DC-DC converter for intra-oral CMOS X-ray image sensors (Intra Oral CMOS X-ray Image Sensor용 DC-DC 변환기 설계)

  • Jang, Ji-Hye;Jin, Li-Yan;Heo, Subg-Kyn;Josonen, Jari Pekka;Kim, Tae-Woo;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2237-2246
    • /
    • 2012
  • A bias circuit required for an oral sensor is manufactured inside the oral sensor chip to reduce its size and cost. The proposed DC-DC converter supplies the required reference and bias currents for their corresponding regulators by using IREF of the reference current generator. Their target voltages of the voltage regulators are regulated by the negative mechanism by generating their reference voltages required for their corresponding regulators. In addition, a constant current IB0/IB1 is supplied by being mirrored by a current mirror ratio and then VREF is generated. It is confirmed by measurements that the average volatge, ${\sigma}$, and $4{\sigma}$ of the designed DC-DC converter for intra oral sensors with a $0.18{\mu}m$ X-ray CMOS process are within their required ranges. And the line-pair pattern image shows a high-resolution characteristic without blurring. Also, a good oral image can be obtained.

Verification of Dose Distribution for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 방사선 수술의 선량분포의 실험적 확인)

  • Park Kyung Ran;Kim Kye Jun;Chu Sung Sil;Lee Jong Young;Joh Chul Woo;Lee Chang Geol;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.421-430
    • /
    • 1993
  • The calculation of dose distribution in multiple arc stereotactic radiotherapy is a three-dimensional problem and, therefore, the three-dimensional dose calculation algorithm is important and the algorithm's accuracy and reliability should be confirmed experimentally. The aim of this study is to verify the dose distribution of stereotactic radiosurgery experimentally and to investigate the effect of the beam quality, the number of arcs of radiation, and the tertiary collimation on the resulting dose distribution. Film dosimetry with phantom measurements was done to get the three-dimensional orthogonal isodose distribution. All experiments were carried out with a 6 MV X-ray, except for the study of the effects of beam energy on dose distribution, which was done for X-ray energies of 6 and 15 MV. The irradiation technique was from 4 to 11 arcs at intervals of from 15 to 45 degrees between each arc with various field sizes with additional circular collimator. The dose distributions of square field with linear accelerator collimator compared with the dose distributions obtained using circular field with tertiary collimator. The parameters used for comparing the results were the shape of the isodose curve, dose fall-offs fom $90\%$ to $50\%$ and from $90\%\;to\;20\%$ isodose line for the steepest and shallowest profile, and $A=\frac{90\%\;isodose\;area}{50\%\;isodose\;area-90\%\;isodose\;area}$(modified from Chierego). This ratio may be considered as being proportional to the sparing of normal tissue around the target volume. The effect of beam energy in 6 and 15 MV X-ray indicated that the shapes of isodose curves were the same. The value of ratio A and the steepest and shallowest dose fall-offs for 6 MV X-ray was minimally better than that for 15 MV X-ray. These data illustrated that an increase in the dimensions of the field from 10 to 28 mm in diameter did not significantly change the isodose distribution. There was no significant difference in dose gradient and the shape of isodose curve regardless of the number of arcs for field sizes of 10, 21, and 32 mm in diameter. The shape of isodose curves was more circular in circular field and square in square field. And the dose gradient for the circular field was slightly better than that for the square field.

  • PDF

Dosimetric Characteristics of Multileaf Collimator-based Intensity-modulated Arc Therapy for Stereotactic Radiosurgery (방사선수술 시 다엽 콜리메이터를 기초로 한 IMAT의 선량분포)

  • Yun, Sang-Mo;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.93-97
    • /
    • 2007
  • This study was designed to evaluate radiosurgery technique using multiple noncoplanar arc therapy with intensity modulated fine MLC shaped photon beam. The stereotactic radiosurgery was performed with 6-MV X-ray beams from a Clinac 21EX LINAC (Varian, Palo Alto, CA, USA) with a MLC-120, which features a full $40{\times}40cm$ field and is the first MLC for general use that offers 0.5 cm resolution for high precision treatment of small and irregular fields. We used a single isocenter and five gantry-couch combinations with a set of intensity modulated arc therapy. We investigated dosimetric characteristics of 2 cm sized spherical target volume with film (X-OMAT V2 film, Kodak Inc, Rochester NY, USA) dosimetry within $25{\times}25cm$ acrylic phantom. A simulated single isocentric treatment using inversely Planned 3D radiotherapy planning system demonstrated the ability to conform the dose distribution to an spherical target volume. The 80% dose level was adequate to encompass the target volume in frontal, sagittal, and transverse planes, and the region between the 40% and 80% isodose lines was $4.0{\sim}4.5mm$ and comparable to the dose distribution of the Boston Arcs. We expect that our radiosurgery technique could be a treatment option for irregular-shaped large intracranial target.

  • PDF

Acoustic scattering characteristics of chub mackerel (Scomber japonicus) by KRM model (KRM 모델을 이용한 고등어(Scomber japonicus)의 음향산란특성 규명)

  • PARK, Geunchang;OH, Wooseok;OH, Sunyoung;LEE, Kyounghoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.1
    • /
    • pp.32-38
    • /
    • 2022
  • In this study, Target strength for multi-frequency (38 kHz, 70 kHz, 120 kHz and 200 kHz) of chub mackerel (Scomber japonicus) was estimated using by the KRM model. The body shape of the Chub mackerel was described by an X-ray system and the body length of 20 individuals ranged from 16 cm to 28 cm. The swimbladder tilt angle ranged between -8 and -14°, the maximum TS value according to the swimming angle of chub mackerel was -33.0 dB at -11°. The averaged TScm according to fork length was -66.02 dB at 38 kHz, -66.50 dB at 70 kHz, -66.00 dB at 120 kHz and -67.35 dB at 200kHz, respectively.

Numerical optimization of transmission bremsstrahlung target for intense pulsed electron beam

  • Yu, Xiao;Shen, Jie;Zhang, Shijian;Zhang, Jie;Zhang, Nan;Egorov, Ivan Sergeevich;Yan, Sha;Tan, Chang;Remnev, Gennady Efimovich;Le, Xiaoyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.666-673
    • /
    • 2022
  • The optimization of a transmission type bremsstrahlung conversion target was carried out with Monte Carlo code FLUKA for intense pulsed electron beams with electron energy of several hundred keV for maximum photon fluence. The photon emission intensity from electrons with energy ranging from 300 keV to 1 MeV on tungsten, tantalum and molybdenum targets was calculated with varied target thicknesses. The research revealed that higher target material element number and electron energy leads to increased photon fluence. For a certain target material, the target thickness with maximum photon emission fluence exhibits a linear relationship with the electron energy. With certain electron energy and target material, the thickness of the target plays a dominant role in increasing the transmission photon intensity, with small target thickness the photon flux is largely restricted by low energy loss of electrons for photon generation while thick targets may impose extra absorption for the generated photons. The spatial distribution of bremsstrahlung photon density was analyzed and the optimal target thicknesses for maximum bremsstrahlung photon fluence were derived versus electron energy on three target materials for a quick determination of optimal target design.

Application of sound scattering models to swimbladdered fish, red seabream (Chrysophys major)

  • Kang Donhyug;Hwang Doojin;Na Jungyul;Kim Suam
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.233-236
    • /
    • 2000
  • The acoustical response of fish depends on size and physical structure na, most important, on the presence or absence of a swimbladder. Acoustic scattering models for swimbladdered fish represent a fish by an ideal pressure-release surface having the size and shape as the swimbladder. Target strength experiments of red seabream (Chrysophrys major) have been conducted using 38 (split-beam), 120 (split-beam) and 200kHz (dual-beam) frequencies. At each start of each experiment, the live fish are placed in the cage at the surface, then the cage is lowed to about $4{\cal}m$ depth where it remains during the measurements. To test the acoustic models, predictions of target strength based on swimbladder morphometries of 10 red seabream offish total length from $103{\cal}mm{\;}to{\;}349{\cal}mm$ ($3 <$TL/\lambda$ < 45)are compared with conventional target strength measurements on the same, shock-frozen immediately after caged experiments. X-ray was projected along dorsal aspect to know the morphological construction of swimbladder. and fish body. At high frequencies, Helmholtz-kirchhoff(HK) approximation would greatly enhance swimbladdered fish modeling. Sound scattering model [HK-ray approximation model] for comparison to experimental target strength data was used to model backscatter measurements from individual fish. The scattering data can be used in the inverse method along with multiple frequency sonar systems to investigate the adequacy of classification and identification of fish

  • PDF

The Effect of Grid Ratio and Material of Anti-scatter Grid on the Scatter-to-primary Ratio and the Signal-to-noise Ratio Improvement Factor in Container Scanner X-ray Imaging

  • Lee, Jeonghee;Lim, Chang Hwy;Park, Jong-Won;Kim, Ik-Hyun;Moon, Myung Kook;Lim, Yong-Kon
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.4
    • /
    • pp.197-204
    • /
    • 2017
  • Background: X-ray imaging detectors for the nondestructive cargo container inspection using MeV-energy X-rays should accurately portray the internal structure of the irradiated container. Internal and external factors can cause noise, affecting image quality, and scattered radiation is the greatest source of noise. To obtain a high-performance transmission image, the influence of scattered radiation must be minimized, and this can be accomplished through several methods. The scatter rejection method using an anti-scatter grid is the preferred method to reduce the impact of scattered radiation. In this paper, we present an evaluation the characteristics of the signal and noise according to physical and material changes in the anti-scatter grid of the imaging detector used in cargo container scanners. Materials and Methods: We evaluated the characteristics of the signal and noise according to changes in the grid ratio and the material of the anti-scatter grid in an X-ray image detector using MCNP6. The grid was composed of iron, lead, or tungsten, and the grid ratio was set to 2.5, 12.5, 25, or 37.5. X-ray spectrum sources for simulation were generated by 6- and 9-MeV electron impacts on the tungsten target using MCNP6. The object in the simulation was designed using metallic material of various thicknesses inside the steel container. Using the results of the computational simulation, we calculated the change in the scatter-to-primary ratio and the signal-to-noise ratio improvement factor according to the grid ratio and the grid material, respectively. Results and Discussion: Changing the grid ratios of the anti-scatter grid and the grid material decreased the scatter linearly, affecting the signal-to-noise ratio. Conclusion: The grid ratio and material of the anti-scatter grid affected the response characteristics of a container scanner using high-energy X-rays, but to a minimal extent; thus, it may not be practically effective to incorporate anti-scatter grids into container scanners.

Fine Structure on the Pigment Epithelial Cell and the Bruch's Membrane of the Rat Retina after X-Irradiation (X-선 조사를 받은 흰쥐 망막의 색소상피세포와 기저복합층의 미세구조)

  • Ko, Jeong-Sik;Shin, Ki-Ho;Ahn, E.Tay;Yang, Nam-Gil;Park, Kyung-Ho;Kim, Jin-Gook
    • Applied Microscopy
    • /
    • v.23 no.2
    • /
    • pp.11-26
    • /
    • 1993
  • This experiment was performed to study the morphological responses of the pigment epithelial cell and the Bruch's membrane of the retina of rat following X-ray irradiation. Male rats were divided into normal and experimental groups. The heads of the rats, under sodium thiopental anesthesia, were exposed to 3,000 rads or 6,000 rads of radiation in a single dose, respectively. The source was a Mitsubishi Linear Accelerator ML-4MV. The target to skin distance was 80cm, and the. dose rate was 200 rads/min. The experimental groups were sacrificed on the 6th hour, 2nd and 6th day after X-ray irradiation. Under anesthesia, 1% glutaraldehyde-1% paraformaldehyde solution(0.1M Millonig's phosphate buffer, pH 7.3) was perfused through the left ventricle and ascending aorta. Pieces of the tissue taken from the posterior region of the retina were fixed in 2.5% glutaraldehyde-1.5% paraformaldehyde(0.1M Millonig's phosphate buffer, pH 7.3) and 1% osmium tetroxide(0.1M Millonig's phosphate buffer, pH7.3), and embedded in araldite mixture. The ultrathin sections contrasted with uranyl acetate and lead citrate were observed with JEM 100 CX-II electron microscope. The results were as follow; 1. The morphological changes of the pigment epithelial cells were not pronounced after exposure to 3,000 rads of X-ray. But on the 6th hour after exposure to 6,000 rads of X-ray, bulging nuclear membrane protruding into the cytoplasm and nuclear chromatin clumped into numerous masses along the nuclear membrane were observed. At the 2nd and 6th day post-irradiation, partial cytolysis or necrosis were seen. 2. The thickness of the Bruch's membrane of the experimental groups were increased in the time and dose range covered by this study, and splitting or diffusing basal laminae of the choriocapillary layer were observed frequently in the experimental group. Above results suggest that large amount(6,000 rads) of head irradiation induce direct hazardous effects on the pigment epitherial cells and Bruch's membrane of the retina of the rat, but pigment epithelial cells are more radioresistant than Bruch's membrane.

  • PDF