• Title/Summary/Keyword: X-ray target

Search Result 470, Processing Time 0.03 seconds

Characterization of Phosphorus Doped ZnO Thin Films grown by Pulsed Laser Deposition Method (펄스 레이저 증착법에 의해 증착된 Phosphorus 도핑된 ZnO 박막의 특성 분석)

  • Lim, Sung-Hoon;Kang, Hong-Seong;Kim, Gun-Hee;Chang, Hyun-Woo;Lee, Sang-Yeol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.55-56
    • /
    • 2005
  • The properties of phosphorus doped ZnO thin films deposited on (001) sapphire substrates by pulsed laser deposition (PLD) were investigated depending on various deposition conditions. The phosphorus (P) doped ZnO target was composed of ZnO + x wt% Al (x=1, 3, 5). The structural, electrical and optical properties of the ZnO thin films were measured by X-ray diffraction (XRD), Hall measurements and photoluminescence (PL). As the deposition temperature optimized, the electrical properties of the phosphorus doped ZnO (ZnO:P) layer showed a electron concentration of $7.76\times10^{16}/cm^3$, a mobility of 10.225 $cm^2/Vs$, a resistivity of 7.932 $\Omega$cm. It was observed the electrical property of the film was changed by dopant activation effect as target variations and deposition conditions.

  • PDF

Property Variation of Diamond-like Carbon Thin Film According to the Annealing Temperature (열처리에 따른 Diamond-like Carbon (DLC) 박막의 특성변화)

  • Park, Ch.S.;Koo, K.H.;Park, H.H.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.1
    • /
    • pp.49-53
    • /
    • 2011
  • Diamond-like carbon (DLC) films is a metastable form of amorphous carbon containing a significant fraction of Sp3 bond. DLC films have been characterized by a range of attractive mechanical, chemical, tribological, as well as optical and electrical properties. In this study DLC films were prepared by the RF magnetron sputter system on $SiO_2$ substrates using graphite target. The effects of the post annealing temperature on the Property variation of the DLC films were examined. The DLC films were annealed at temperatures ranging from 300 to $500^{\circ}C$ using rapid thermal process equipment in vacuum. The variation of electrical property and surface morphology as a function of annealing treatment was investigated by using a Hall Effect measurement and atomic force microscopy. Raman and X-ray photoelectron spectroscopy analyses revealed a structural change in the DLC films.

Clinical Application of Artificial IntelligenceBased Detection Assistance Devices for Chest X-Ray Interpretation: Current Status and Practical Considerations (흉부 X선 인공지능 검출 보조 의료기기의 임상 적용: 현황 및 현실적 고려 사항)

  • Eui Jin Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.4
    • /
    • pp.693-704
    • /
    • 2024
  • Artificial intelligence (AI) technology is actively being applied for the interpretation of medical imaging, such as chest X-rays. AI-based software medical devices, which automatically detect various types of abnormal findings in chest X-ray images to assist physicians in their interpretation, are actively being commercialized and clinically implemented in Korea. Several important issues need to be considered for AI-based detection assistant tools to be applied in clinical practice: the evaluation of performance and efficacy prior to implementation; the determination of the target application, range, and method of delivering results; and monitoring after implementation and legal liability issues. Appropriate decision making regarding these devices based on the situation in each institution is necessary. Radiologists must be engaged as medical assessment experts using the software for these devices as well as in medical image interpretation to ensure the safe and efficient implementation and operation of AI-based detection assistant tools.

The Study of Formation of Ti-silicide deposited with Composite Target [II] (Composite Target으로 증착된 Ti-silicide의 현성에 관한 연구[II])

  • Choi, Jin-Seog;Paek, Su-Hyon;Song, Young-Sik;Sim, Tae-Un;Lee, Jong-Gil
    • Korean Journal of Materials Research
    • /
    • v.1 no.4
    • /
    • pp.191-197
    • /
    • 1991
  • The surface roughnesses of titanium silicide films and the diffusion behaviours of dopants in single crystal and polycrystalline silicon substrates durng titanium silicide formation by rapid thermal annealing(RTA) of sputter deposited Ti-filicide film from the composite $TiSi_{2.6}$ target were investigated by the secondary ion mass spectrometry(SIMS), a four-point probe, X-ray diffraction, and surface roughness measurements. The as-deposited films were amorphous but film prepared on single silicon substrate crystallized to the orthorhombic $TiSi_2$(C54 structure) upon rapid thermal annealing(RTA) at $800^{\circ}C$ for 20sec. There was no significant out-diffusion of dopants from both single crystal and polycrystalline silicon substrate into titanum silicide layers during annealing. Most of the implanted dopants piled up near the titanium silicide/silicon interface. The surface roughnesses of titanium silicide films were in the range between 16 and 22nm.

  • PDF

Quasi-monochromatic Parallel Radiography Achieved with a Polycapillary Plate

  • Sato, Eiichi;Komatsu, Makoto;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Ichimaru, Toshio;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.418-421
    • /
    • 2002
  • Fundamental study on quasi-monochromatic parallel radiography using a polycapillary plate and a plane-focus x-ray tube is described. The x-ray generator consists of a negative high-voltage power supply, a filament (hot cathode) power supply, and an x-ray tube. The negative high-voltage is applied to the cathode electrode, and the transmission type target (anode) is connected to the ground potential. The maximum voltage and current of the power supply were -100 kV (peak value) and 3.0 mA, respectively. In this experiment, the tube voltage was regulated from 20 to 25 kV, and the tube current was regulated by the filament temperature and ranged from 1.0 to 3.0 mA. The exposure time is controlled in order to obtain optimum film density, and the focal spot diameter was about 10 mm. The polycapillary plate is J5022-21 made by Hamamatsu Photonics Inc., and the outside and effective diameters are 87 and 77 mm, respectively. The thickness and the hole diameter of the polycapillary are 1.0 mm and 25 ${\mu}$m, respectively. The x-rays from the tube are formed into parallel beam by the polycapillary, and the radiogram is taken using an industrial x-ray film of Fuji IX 100 without using a screen. In the measurement of image resolution, we employed three brass spacers of 2, 30, and 60 mm in height. By the test chart, the resolution fell according to increases in the spacer height without using a polycapillary. In contrast, the resolution slightly fell with corresponding increases in the height by the polycapillary. In angiography, fine blood vessels of about 100 ${\mu}$m are clearly visible.

  • PDF

Fine Structure on the Epidermis of the Scalp of the Head-Irradiated Rats (방사선 조사를 받은 흰쥐 머리피부 표피층의 미세구조)

  • Ko, Jeong-Sik;Kim, Jae-Ho;Yang, Nam-Gil;Ahn, E-Tay;Park, Kyung-Ho;Kim, Jin-Gook
    • Applied Microscopy
    • /
    • v.24 no.2
    • /
    • pp.63-77
    • /
    • 1994
  • This experiment was performed to study the morphological responses of the epidermis of the rat scalp, following X-ray irradiation. Male rats were divided into normal and experimental groups. Rats anesthetized with sodium thiopental, were exposed only on their head areas with a single dose of 3,000rads or 6,000rads, respectively. Radiation was produced by Mitsubishi Linea Accelerator ML-4MV at the speed of 200rads/min. The target distance was 80cm. Animals were sacrificed on six hours, two days and six days following irradiation. By the perfusion fixation through the heart, rats were fixed with 1% glutaraldehyde-1% paraformaldehyde solution. Pieces of the tissue taken from the scalp were refixed in 2.5% glutaraldehyde-1.5% paraformaldehyde solution, followed by post-fixation with 1% osmium tetroxide, and embedded within araldite mixture. The sections were cut on a LKB-V ultratome, stained with uranyl acetate and lead citrate, and were observed with JEM 100CX-II electron microscope. The results were as follow; 1. Six hours after exposure to 3,000rads of X-ray. Disrupted intercellular spaces, within which some amorphous materials were filled, disrupted mitochondria, and vacuoles in the keratinocytes were frequently observed, but six days after exposure to 3,000rads of X-ray, Morphology of the keratinocytes was generally restored. 2. Many of the morphological changes were seen on the six days after exposure to 6,000rads of X-ray. 3. Widened intercellular spaces and thickened dense plaques of the desmosomes were frequently observed after exposure to 6,000rads of X-ray. 4. In the experimental groups, the Langerhans and the Merkel cells were damaged, similarly to the keratinocyte. Above results suggest that head irradiation with the dose of 3,000rads temporarily damaged the epidermis of the scalp, though most of the structures recover within six days, whereas with the dose of 6,000rads it severely damaged the epidermis without showing any recovering tendency.

  • PDF

Image reconstruction algorithm for momentum dependent muon scattering tomography

  • JungHyun Bae;Rose Montgomery;Stylianos Chatzidakis
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1553-1561
    • /
    • 2024
  • Nondestructive radiography using cosmic ray muons has been used for decades to monitor nuclear reactor and spent nuclear fuel storage. Because nuclear fuel assemblies are highly dense and large, typical radiation probes such as x-rays cannot penetrate these target imaging objects. Although cosmic ray muons are highly penetrative for nuclear fuels as a result of their relatively high energy, the wide application of muon tomography is limited because of naturally low cosmic ray muon flux. This work presents a new image reconstruction algorithm to maximize the utility of cosmic ray muon in tomography applications. Muon momentum information is used to improve imaging resolution, as well as muon scattering angle. In this work, a new convolution was introduced known as M-value, which is a mathematical integration of two measured quantities: scattering angle and momentum. It captures the objects' quantity and density in a way that is easy to use with image reconstruction algorithms. The results demonstrate how to reconstruct images when muon momentum measurements are included in a typical muon scattering tomography algorithm. Using M-value improves muon tomography image resolution by replacing the scattering angle value without increasing computation costs. This new algorithm is projected to be a standard nondestructive radiography technique for spent nuclear fuel and nuclear material management.

Effect of the Substrate Temperature on the Characteristics of CIGS Thin Films by RF Magnetron Sputtering Using a $Cu(In_{1-x}Ga_x)Se_2$ Single Target

  • Jung, Sung-Hee;Kong, Seon-Mi;Fan, Rong;Chung, Chee-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.382-382
    • /
    • 2012
  • CIGS thin films have received great attention as a promising material for solar cells due to their high absorption coefficient, appropriate bandgap, long-term stability, and low cost production. CIGS thin films are deposited by various methods such as co-evaporation, sputtering, spray pyrolysis and electro-deposition. The deposition technique is one of the most important processes in preparing CIGS thin film solar cells. Among these methods, co-evaporation is one of the best technique for obtaining high quality and stoichiometric CIGS films. However, co-evaporation method is known to be unsuitable for commercialization. The sputtering is known to be very effective and feasible process for mass production. In this study, CIGS thin films have prepared by rf magnetron sputtering using a $Cu(In_{1-x}Ga_x)Se_2$ single quaternary target without post deposition selenization. This process has been examined by the effects of deposition parameters on the structural and compositional properties of the films. In addition, we will explore the influences of substrate temperature and additional annealing treatment after deposition on the characteristics of CIGS thin films. The thickness of CIGS films will be measured by Tencor-P1 profiler. The crystalline properties and surface morphology of the films will be analyzed using X-ray diffraction and scanning electron microscopy, respectively. The optical properties of the films will be determined by UV-Visible spectroscopy. Electrical properties of the films will be measured using van der Pauw geometry and Hall effect measurement at room temperature using indium ohmic contacts.

  • PDF

Diagnosis of Thickness Quality Using Multivariate Statistical Analysis in Hot Finishing Mill

  • Kim, Heung-Mook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.116.3-116
    • /
    • 2001
  • A diagnosis methodology for thickness quality in hot finishing mill is proposed based on multivariate statistical analysis. The thickness of hot strip is a key quality factor that is measured by x-ray thickness gauge. Currently, the thickness quality is guaranteed by upper and lower limit of thickness deviation from target thickness. But if any over-limit is occurred, there is no in-line method to identify the causes. In this paper, many parameters are extracted from the thickness deviation signal such as mean deviation(top, middle, tail), rms deviation(top, middle, tail) and peak deviation(top, middle, tail) as time domain parameters ...

  • PDF

A study on the fabrication of Y-Ba-Cu-O High Tc superconducting thin film by sputtering system (스퍼터링 방식에 의한 Y-Ba-Cu-O 고온 초전도 박박의 제작에 관한 연구)

  • Chae, Kee-Byung;Kang, Ki-Sung;Soh, Dae-Wha
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.81-83
    • /
    • 1992
  • The superconducting thin films deposited on $SiO_x$ substrate by R.F magnetron sputter using $YBa_2Cu_3O_x$ single target have been made and annealed at $940^{\circ}C$ for 30 min. The thickness of films were 1000-2000${\AA}$ with a rate of 20-25${\AA}/min$ and superconducting properties of thin films depended on the compositions of pre-annealed the thin films. It has been analyzed by SEM photo-analysis and X-ray diffraction patterns of these samples obtained under the various conditions of this sputtering methods. and recognized the supperconducting thin films by electric properties.

  • PDF