• Title/Summary/Keyword: X-ray target

Search Result 470, Processing Time 0.033 seconds

Oprimization Study for the CRC PIXE System Beam Transport Line

  • Jeong, Cheol-Ki;Lee, Goung-Jin
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.59-63
    • /
    • 2014
  • Proton Induced X-ray Emission (PIXE) is a MeV ion beam analysis method for use with particle accelerators. PIXE uses low-energy charged particles as an excitation mechanism to generate characteristic x-ray emission from each element in a target. In PIXE analysis, the beam current used is from a few nA to several tens of nA. Chosun University (Cyclotron Research Center) designed a $50{\mu}A$ beam line from the 13 MeV cyclotron for use with a PIXE analysis system, as well as performing beam transport line optimization research. In this study, the beam line operation conditions for the optimization process of beam transport and beam characteristics are shown.

RF-Sputted Vanadium Oxide Thin Films:Effect of Oxygen Partial Pressure on Structural and Electrochemical Properties

  • Park, Yong Jun;Park, Nam Gyu;Ryu, Gwang Seon;Jang, Sun Ho;Park, Sin Jong;Yun, Seon Mi;Kim, Dong Guk
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.9
    • /
    • pp.1015-1018
    • /
    • 2001
  • Vanadium oxide thin films with thickness of about 2000 $\AA$ have been prepared by radio frequency sputter deposition using a V2O5 target in a mixed argon and oxygen atmosphere with different Ar/O2 ratio ranging from 99/1 to 90/10. X-ray diffraction and X-ray absorption near edge structure spectroscopic studies show that the oxygen content higher than 5% crystallizes a stoichiometric V2O5 phase, while oxygen deficient phase is formed in the lower oxygen content. The oxygen content in the mixed Ar + O2 has a significant influence on electrochemical lithium insertion/deinsertion property. The discharge-charge capacity of vanadium oxide film increases with increasing the reactive oxygen content. The V2O5 film deposited at the Ar/O2 ratio of 90/10 exhibits high discharge capacity of 100 ${\mu}Ah/cm2-{\mu}m$ along with good cycle performance.

X-Ray Absorption Spectroscopic Study of 120 MeV $Ag^{9+}$ Ion-Irradiated N-Doped ZnO Thin Films

  • Gautam, Sanjeev;Lim, Weon Cheol;Kang, Hee Kyung;Lee, Ki Soo;Song, Jaebong;Song, Jonghan;Asokan, K.;Chae, Keun Hwa
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.315-315
    • /
    • 2013
  • We report the electronic structure modification in the swift heavy ion (SHI) irradiated N-doped ZnO thin films prepared by RF sputtering from ZnO target in different ratio of Ar/$N_2$ gas mixture using highly pure $N_2$ gas. The different N-ZnO thin lms were then irradiated with 120 MeV Ag ion beam with different doses ranging from $1{\times}10^{11}$ to $5{\times}10^{12}$ ions/$cm^2$ and characterized by XRD and near edge X-ray absorption ne structure (NEXAFS) at N and O K-edges. The NEXAFS measurements provide direct evidence of O 2p and Zn 3d orbital hybridization and also the bonding of N ions with Zn and O ions. The minimum value of resistivity of $790{\Omega}cm$, a Hall mobility of $22cm^2V^-1s^-1$ and the carrier concentration of $3.6{\times}10^{14}cm^{-3}$ were yielded at 75% $N_2$. X-ray diffraction (XRD) measurements revealed that N-doped ZnO films had the preferential orientation of (002) plane for all samples, while crystallinity start decreasing at 32.5% $N_2$. The average crystallite size varies from 5.7 to 8.2 nm for 75% and then decreases to 7.8 nm for 80% $Ar:N_2$ ratio.

  • PDF

Quality Assurance System for Determination of Center Position in X-ray and Proton Irradiation Fields using a Stainless Ball and Imaging Plates in Proton Therapy at PMRC

  • Yasuoka, Kiyoshi;Ishikawa, Satoko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.189-191
    • /
    • 2002
  • In the proton therapy using a gantry system, periodical verification of iso-center position is very important to assure precision of patient positioning system at any gantry angles in proton treatment. In the gantry system, there are three different types of iso-center; 1) in a geometrical view, 2) in an X-ray beam's eye view, 3) in a proton beam's eye view. Idealistically, they would be an identical point. They could, however, be different points. It may be a source of errors in patient positioning. At PMRC, we have established a system of verification for iso-center positions using a stainless ball of 2-cm in diameter and an imaging plate. This system provides the relation among a center of a patient target position, a center of proton irradiation field, and/or a center of X-ray field in accuracy of 50$\square$m in the 2) and 3) views, as images of a center of the stainless ball and a center of a 100 mm${\times}$100 mm-aperture brass collimator recorded on the imaging plate, which is setup at 1-cm behind the ball. In addition, it provides simultaneously the images of the ball and the collimator on an imaging intensifier (II), which is setup downstream of the proton or X-ray beam. We present a method of quality assurance (QA) for calibration of iso-center position in a rotation gantry system at PMRC and the performance of this system. A proton beam position on the 1$\^$st/ scatterer in the nozzle of the gantry affects less sensitive (reduced by a factor of 1/5) to the results of the iso-center position. The effect is systematically correctable. The effect of the nozzle (or the collimator) position is less than 0.5 mm at the maximum extraction (390 mm).

  • PDF

Study of Energy Dependency in Intensity Modulated Radiation Therapy of Brain Tumor (세기조절방사선치료를 이용한 뇌종양에서 에너지 의존성에 관한 연구)

  • 김성규
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.104-108
    • /
    • 2002
  • As intensity modulated radiation therapy compared with conventional radiation therapy, tumor target dose increased and normal tissues and critical organs dose reduced. In brain tumor, treatment planning of intensity modulated radiation therapy was practiced in 4MV, 6MV, 15MV X-ray energy. In these X-ray energy, was considered the dose distribution and dose volume histogram. As 4MV X-ray compared with 6MV and 15MV, maximum dose of right optic-nerve increased 10.1%, 8.4%. Right eye increased 5.2%, 2.7%. And left optic-nerve, left eye, optic chiasm and brainstem increased 1.7% - 5.2%. Even though maximum dose of PTV and these critical organs show different from 1.7% - 10.1% according to X-ray energies, these are a piont dose. Therefore in brain tumor, treatment planning of intensity modulated radiation therapy in 9 treatment field showed no relation with energy dependency.

  • PDF

Production and Utility Assessment of Pediatric Genital Shields Using 3D Printing Technology with Colorjet 3D Printing (결합제 분사 방식 3D 프린팅 기술을 활용한 소아 생식기 차폐체 제작 및 유용성 평가)

  • In-Ja Lee;Da-Yeong Hong
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.543-551
    • /
    • 2023
  • In this study, the aim was to assess the shielding performance of different 3D printing materials, specifically those produced using FDM, SLA, and CJP methods, with a focus on their application as shielding devices in clinical settings. Additionally, the weight of lead shielding materials can evoke reluctance in pediatric patients undergoing X-ray imaging. A total of 12 materials were printed using their respective 3D printers. These materials were then subjected to X-ray testing using diagnostic X-ray equipment and an exposure meter. The goal was to evaluate their shielding capabilities in comparison to 1 mm lead. The results of this evaluation revealed that VisiJet PXL-Pastel, produced using the CJP method, exhibited the highest shielding performance. Therefore, VisiJet PXL-Pastel by CJP method was selected for the creation of a shielding device designed for pediatric reproductive organs. Subsequent tests demonstrated that both the newly created shielding device and conventional lead shielding equipment achieved the same maximum shielding rate at 50 kVp. Specifically, the shielding rate for the 3D printed device was measured at 84.53%, while the conventional lead shielding equipment, categorized as Apron1 (85.74%), Apron2 (99.98%), and Apron3 (99.04%), demonstrated similar performance. In conclusion, the CJP-produced VisiJet PXL-Pastel material showcased excellent radiation shielding capabilities, allowing for anatomical observations of the target organs and their surrounding structures in X-ray images. Furthermore, its lower weight in comparison to traditional lead shielding materials makes it a clinically practical and useful choice, particularly for pediatric applications.

In situ Electric-Field-Dependent X-Ray Diffraction Experiments for Ferroelectric Ceramics (강유전 세라믹의 전기장 인가에 따른 in situ X-선 회절 실험)

  • Choi, Jin San;Kim, Tae Heon;Ahn, Chang Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.5
    • /
    • pp.431-438
    • /
    • 2022
  • In functional materials, in situ experimental techniques as a function of external stimulus (e.g., electric field, magnetic field, light, etc.) or changes in ambient environments (e.g., temperature, humidity, pressure, etc.) are highly essential for analyzing how the physical properties of target materials are activated/evolved by the given stimulation. In particular, in situ electric-field-dependent X-ray diffraction (XRD) measurements have been extensively utilized for understanding the underlying mechanisms of the emerging electromechanical responses to external electric field in various ferroelectric, piezoelectric, and electrostrictive materials. This tutorial article briefly introduces basic principles/key concepts of in situ electric-field-dependent XRD analysis using a lab-scale XRD machine. We anticipate that the in situ XRD method provides a practical tool to systematically identify/monitor a structural modification of various electromechanical materials driven by applying an external electric field.

Docking Study of the Cystein Protease Cathepsin K Inhibitors : A Target for the Treatment of Osteoporosis

  • Park, Heung-Jin;Park, Hyung-Yeon;Kim, Chan-Kyung;Lee, Bon-Su
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.180.2-180.2
    • /
    • 2003
  • Cathepsin K, a cysteine protease of the papain superfamily, is predominantly expressed in osteoclasts and has been postulated as a target for the treatment of osteoporosis. Crystallographic and structure-activity studies on a series of azepanone-based diamino and acyclic ketone derivative inhibitors of cathepsin K have led to the design and identification. X-ray structure of the cysteine protease cathepsin K (1NL6) co-crystalized with an inhibitor with 2.8${\AA}$ resolution was used to predict the protein-ligand interactions and to estimate the binding affinity from the docking score by FlexX module. (omitted)

  • PDF

Evaluation of Hydrogenation Properties on Ti-Cr-Nb Alloys Manufactured by Arc Melting (아크용해법에 의한 Ti-Cr-Nb합금의 제조와 수소와 특성 평가)

  • Lee, Young-Geun;Hong, Tae-Whan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.6
    • /
    • pp.482-489
    • /
    • 2008
  • Ti-Cr alloys consist of BCC solid solution, C36, C14 and C15 Laves phase at high temperature. Among others, the BCC solid solution phase was reported to have a high hydrogen storage capacity. However, activation, wide range of hysteresis at hydrogenation/dehydrogenation, and degradation of hydrogen capacity due to hydriding/dehydriding cycles must be improved for its application. In this study, to improve such problems, we added a Nb. For attaining target materials, Ti-10Cr-xNb(x=1, 3, 5wt.%) specimens were prepared by arc melting. The arc melting process was carried out under argon atmosphere. As-received specimens were characterized using XRD(X-ray diffraction), SEM(Scanning Electron Microscopy) with EDX(Energy Dispersive X-ray) and TG/DSC(Thermo Gravimetric Analysis/Differential Scanning Calorimetry). In order to examine hydrogenation behavior, the PCI(pressure-Composition-Isotherm) was performed at 293, 323, 373 and 423K.

Development of an electron source using carbon nanotube field emittes for a high-brightness X-ray tube (탄소나노튜브를 이용한 고휘도 X-선원용 전자빔원 개발)

  • Kim, Seon-Kyu;Heo, Sung-Hwan;Cho, Sung-Oh
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.252-257
    • /
    • 2005
  • A high-brightness electron beam source for a microfocus X-ray tube has been fabricated using a carbon-nanotube (CNT) field emitter. The electron source consists of cathode that includes a CNT field emitter, a beam-extracting grid, and an anode that accelerates that electron beam. The microfocus X-ray tube requires an electron beam with the diameter of less than 5 $\mu$m and beam current of higher than 30 $\mu$A at the position of the X-ray target. To satisfy the requirements, the geometries of the field emitter tips and the electrodes of the gun was optimized by calculating the electron trajectories and beam spatial profile with EGUN code. The CNT tips were fabricated with successive steps: a tungsten wire with the diameter of 200 $\mu$m was chemically etched and was subsequently coated with CNTs by chemical vapor deposition. The experiments of electron emission at the fabricated CNT tips were performed. The design characteristics and basic experimental results of the electron source are reported.