• 제목/요약/키워드: X-ray system

검색결과 2,307건 처리시간 0.036초

신명 레이저와 X-선 발생 연구 (Simmyung Laser System and Study on the X-ray Generation)

  • Kong, Hong-Jin;Han, Ki-Gwan;Kim, Nam-Seong;Kim, Hyun-Soo;Um, Ki-Young;Park, Jong-Rak;Lee, Jae-Youg;Shin, Yun-Sup;Han, Ki-Ho
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1995년도 광학 및 양자전자학 워크샵 논문집
    • /
    • pp.185-189
    • /
    • 1995
  • A high-power Nb:glass laser system(Simmyung I) has been contructed and tested. In this system, we used a Nb:YLF laser as a master oscillator, a 4-pass amplifier for pre-amplification, 5 stages of rod amplifiers, and spatial filtering and image reaying usits. The system has demonstrated in excess of 80J(2TW) with 40 psec(FWHM) pulse duration. Output energy, gain and spatial were measured at each amplification stage. With this laser system a preliminary X-ray generation experiment was performed. Pinhole images, X-ray diode signals and X-ray speriment were obtained for the irradiated target of copper. Detailed descriptions of the system performance and the X-tay generation experiment are presented.

  • PDF

s-IGDT 시스템의 X-선원 배열 형태 및 투영상 개수에 따른 영상 화질 평가에 관한 연구 (Image Quality Evaluation according to X-ray Source Arrangement Type and the Number of Projections in a s-IGDT System)

  • 이다혜;남기복;이승완
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.117-125
    • /
    • 2022
  • Although stationary inverse-geometry digital tomosynthesis (s-IGDT) is able to reduce motion artifacts, image acquisition time and radiation dose, the image quality of the s-IGDT is degraded due to the truncations arisen in projections. Therefore, the effects of geometric and image acquisition conditions in the s-IGDT should be analyzed for improving the image quality and clinical applicability of the s-IGDT system. In this study, the s-IGDT images were obtained with the various X-ray source arrangement types and the various number of projections. The resolution and noise characteristics of the obtained s-IGDT images were evaluated, and the characteristics were compared with those of the conventional DT images. The s-IGDT system using linear X-ray source arrangement and 40 projections maximized the image characteristics of resolution and noise, and the corresponding system was superior to the conventional DT system in terms of image resolution. In conclusion, we expect that the s-IGDT system can be used for providing medical images in diagnosis.

경 엑스선 존 플레이트(Zone Plate) 설계 및 제작 (Design and Fabrication of Hard X-ray Zone Plate)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제4권3호
    • /
    • pp.27-31
    • /
    • 2010
  • 엑스선 영상의 공간분해능은 영상획득 장치에 사용되는 광학소자의 성능에 의해 결정된다. 8.5keV에서 높은 공간분해능 달성이 가능한 존 플레이트를 설계하였다. 방사광을 이용하는 대신 엑스선 튜브를 사용하는 영상시스템에서는 80nm의 공간분해능을 달성할 수 있음을 광선추적 기법을 이용하여 예측하였다. 전자빔 석판인쇄술을 이용하여 최외곽 폭 40nm를 갖는 존 플레이트가 제작하였다.

PCB 납땜 검사를 위한 X선 단층 영상 시스템의 해석 및 설계 (The analysis and design of X-ray cross sectional imaging system for PCB solder joint inspection)

  • 노영준;강성택;김형철;김성권
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.109-112
    • /
    • 1996
  • The more integrated and smaller SMD are needed, new solder joints packaging technologies are developed in these days such as BGA(Ball Grid Array), Flip Chip, J-lead etc. But, it's unable to inspect solder joints in those devices by visual inspection methods, because they are hided by it's packages. To inspect those new SMD packages, an X-ray system for acquiring a cross-sectional image of a arbitrary plane is necessary. In this paper, an analysis for designing X-ray cross sectional imaging system is presented including the way for correcting the distortion of image intensifier. And we show computer simulation of that system with a simple PCB model to show it's usefulness in applying PCB solder joint inspection.

  • PDF

Investigation About Quality Control of General X-ray System

  • Kang, Byung-Sam;Son, Jin-Hyun;Dong, Kyung-Rae
    • 대한디지털의료영상학회논문지
    • /
    • 제13권4호
    • /
    • pp.157-164
    • /
    • 2011
  • This test is for checking investigation about quality control of general X-ray system in clinic and hospital. We compared general X-ray system of clinic and hospital which are selected freely in the metropolitan area using PMX-III and carried out quality control. Carried out Kilovoltage test, mR/mAs output test, Light filed/Beam alignment test, Half value layer test. Most of test result are appeared that failure rates of clinic is higher than hospital one. Therefore, we should lower failure rates through regular quality control and make environment which can get high quality image.

  • PDF

A method of X-ray source spectrum estimation from transmission measurements based on compressed sensing

  • Liu, Bin;Yang, Hongrun;Lv, Huanwen;Li, Lan;Gao, Xilong;Zhu, Jianping;Jing, Futing
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1495-1502
    • /
    • 2020
  • A new method of X-ray source spectrum estimation based on compressed sensing is proposed in this paper. The algorithm K-SVD is applied for sparse representation. Nonnegative constraints are added by modifying the L1 reconstruction algorithm proposed by Rosset and Zhu. The estimation method is demonstrated on simulated spectra typical of mammography and CT. X-ray spectra are simulated with the Monte Carlo code Geant4. The proposed method is successfully applied to highly ill conditioned and under determined estimation problems with a good performance of suppressing noises. Results with acceptable accuracies (MSE < 5%) can be obtained with 10% Gaussian white noises added to the simulated experimental data. The biggest difference between the proposed method and the existing methods is that multiple prior knowledge of X-ray spectra can be included in one dictionary, which is meaningful for obtaining the true X-ray spectrum from the measurements.

X선관을 이용한 불투명한 물체 내부 유동의 정량적 가시화 연구 (Quantitative Flow Field Visualization of a Flow inside an Opaque Tube Using Angiographic PIV Method)

  • 김국배;임남윤;류재춘;임대현;이형구;이상준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2935-2940
    • /
    • 2007
  • To diagnose circulatory diseases in the viewpoint of hemodynamics, we need to get quantitative hemodynamic information of blood flows related with the vascular diseases with high spatial resolution of tens micrometer and high temporal resolution in the order of millisecond. For investigating in-vivo hemodynamic phenomena, a new diagnosing technique combining medical radiography and PIV method was newly proposed and developed. This angiographic PIV technique consists of a medical X-ray tube, an X-ray CCD camera, a shutter module for double pulses of X-ray, and a synchronizer. The feasibility of the angiographic PIV technique was tested and quantitative flow velocity field distribution of a flow inside an opaque conduit was acquired by the developed system. It can be used for measuring flow phenomena of nontransparent fluids inside opaque conduits.

  • PDF

구내 방사선발생기의 선량 분포측정을 통한 필름유지기구(XCP-DS FIT)의 피폭선량감소에 대한 유용성 (Utilization-Focused Reduction of Radiation Exposure with XCP-DS FIT Sensor Holder by Measuring Dose of Dental X-ray Generator)

  • 이경희
    • 한국방사선학회논문지
    • /
    • 제6권6호
    • /
    • pp.465-471
    • /
    • 2012
  • 본 연구에서는 ALOKA PDM-117(X-ray 측정용 선량계)선량계를 이용하여 구내방사선 촬영기에서 발생하는 방사선에 대하여 거리의 변화에 따른 선량분포를 3차원으로 측정하였다. 구내 방사선촬영에 있어서 XCP 필름 유지기구(XCP-DS FIT)를 사용하여 영상을 얻는 경우 방사선의 선량 분포는 변할 수 있고 이것은 방사선영상과 환자피폭에 영향을 미치게 된다. 따라서 위치에 따른 선량을 표준화하여 XCP 필름 유지기구 사용 유무에 따른 선량과의 관계를 알아볼 필요성이 있다. 본 연구에서는 측정된 3차원 선량분포를 통하여 등각촬영시 얻을 수 있는 최적의 영상과 동일한 선량을 얻기 위한 조사시간과 거리와의 관계 및 선량분포의 모서리 퍼짐 현상에 대한 결과를 정량적으로 측정하였다. 거리가 증가함에 따라 중심 선량은 감소하였지만 조사통 가장자리 부분의 방사선 퍼짐은 증가하는 경향을 보였다. 이것은 XCP 필름 유지기구를 사용하는 경우에 선속 가장자리 부분에서 방사선의 선량이 퍼지는 경향을 보이기 때문이므로 환자의 병소이외의 부분에 대한 피폭에 주의를 기울여야 함을 정량적으로 확인 하였다. 본 연구의 결과는 품질 좋은 치아영상을 얻고, 환자의 피폭선량을 줄이는데 매우 유용하게 사용되어 질 수 있을 것으로 사료된다.

X-ray 후방산란 기술을 이용한 항공기용 복합재료의 다중 층간 박리 평가 (Assessment of Multiple Delamination in Laminated Composites for Aircrafts using X-ray Backscattering)

  • 김노유
    • 비파괴검사학회지
    • /
    • 제30권1호
    • /
    • pp.46-53
    • /
    • 2010
  • 항공기용 복합재료 내부 여러 층에서 발생하는 박리를 정량적으로 평가하기 위한 X-ray 후방산란 검사장치를 개발하였다. 복합재료 두께방향으로의 역산란 밀도변화로부터 층간 박리를 검사하는 슬릿 방식의 카메라와 컴퓨터로 제어되는 X-ray 선원, 그리고 센서로 구성되는 X-ray 후방산란장치를 제작하여 그 성능을 충격하중에 의해 만들어진 인공결함시편을 이용해 검증하였다. 결함평가를 위해 복합재료내 산란장의 크기를 이론적으로 계산하는 수학적 해석 모델을 볼츠만 방정식을 이용하여 제안하였으며 적응필터 알고리즘을 사용하여 산란 노이즈를 최소화 하였다. 다중 박리 결함을 X-ray 후방산란장치를 통해 효과적으로 검출하였으며, 박리 위치와 박리 상태를 모두 정확하게 검사할 수 있음을 실험을 통해 확인하였다.

Calibration-free real-time organic film thickness monitoring technique by reflected X-Ray fluorescence and compton scattering measurement

  • Park, Junghwan;Choi, Yong Suk;Kim, Junhyuck;Lee, Jeongmook;Kim, Tae Jun;Youn, Young-Sang;Lim, Sang Ho;Kim, Jong-Yun
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1297-1303
    • /
    • 2021
  • Most thickness measurement techniques using X-ray radiation are unsuitable in field processes involving fast-moving organic films. Herein, we propose a Compton scattering X-ray radiation method, which probes the light elements in organic materials, and a new simple, non-destructive, and non-contact calibration-free real-time film thickness measurement technique by setting up a bench-top X-ray thickness measurement system simulating a field process dealing with thin flexible organic films. The use of X-ray fluorescence and Compton scattering X-ray radiation reflectance signals from films in close contact with a roller produced accurate thickness measurements. In a high-thickness range, the contribution of X-ray fluorescence is negligible, whereas that of Compton scattering is negligible in a low-thickness range. X-ray fluorescence and Compton scattering show good correlations with the organic film thickness (R2 = 0.997 and 0.999 for X-ray fluorescence and Compton scattering, respectively, in the thickness range 0-0.5 mm). Although the sensitivity of X-ray fluorescence is approximately 4.6 times higher than that of Compton scattering, Compton scattering signals are useful for thick films (e.g., thicker than ca. 1-5 mm under our present experiment conditions). Thus, successful calibration-free thickness monitoring is possible for fast-moving films, as demonstrated in our experiments.