• Title/Summary/Keyword: X-ray method

Search Result 4,392, Processing Time 0.03 seconds

X-ray Fluorescence Analysis of Chemical Ingredients for Portland Cement (X-선 형광분석법에 의한 포틀란드 시멘트의 정량분석)

  • 임헌진;백연봉;김도생;윤준수;이경원
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.8
    • /
    • pp.928-934
    • /
    • 1996
  • Quantitative analysis each portland cement components was conducted by standard calibration method using X-ray fluorescence spectrometer. Standard sample and the unknown sample were prepared by fused cast bead method. In checking the errors of standard cement 227A372 the relative errors of constituents such as CaO, SiO2, Al2O3, Fe2O3, MgO and SrO were less than 1% and the relative errors of constituents such as So3, K2O, TiO2, Na2O P2O5, and Mn2O3 were less than 5% Sample preparation was mainly contributed to the errors. Compared with general wet chemical method the results of X-ray fluorescence analyses were more precise and accurate. Moreover it is possible to analyze precisely a little amount of the constituents such as SrO, Mn2O3 and P2O5 the analyses of which were very difficult using the wet chemical method.

  • PDF

Usefulness of Non-Invasive Measurement Tool on Performance Evaluation of Inverter Type X-ray Unit (인버터식 X선장치의 성능평가 시 비접속형 측정기의 유용성)

  • Kang, Se-Sik;Kim, Chang-Soo;Ko, Sung-Jin
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.123-127
    • /
    • 2008
  • Purpose: As the demand of a simple and precise method increases to evaluate the performance of the inverter type x-ray unit, we evaluated the usefulness of the recently-introduced X-ray Multi-Function Test Device (moldel : Xi (unfors)-prestige). Method: We compared the performance of X-ray Multi-Function Test Device (XMFTD) which is non-inveasive type device with the performance of Dynalyzer III that has been most widely used inveasive type measure device. Result: X-ray output dose was increased a little in the XMFTD, but both devices were below the performance evaluation standard, 0.002 in the output reproducibility. Linearity of XMFTD were below 0.1 which means that Dynalyzer III showed more excellency in linearity. As the the accuracy of exposure factor, 1.8 and 2 tube voltage, 2.01 and 2.3 tube current were measured. The exposure time was also measured by 0.01 sec ${\pm}10%$. Both devices were within the acceptance of performance evaluatioin standard. Conclusion: We proved the usefulness of X-ray Multi-Function Test Device (model: Xi (unfors)-prestige) to evaluated the performance on reproductibility and linearity of X-ray output and accuracy of exposure factor of inverter type unit.

  • PDF

Development of Portable X-ray CT System I - Evaluation of Wood Density using X-ray Radiography - (현장 적용이 가능한 X선 CT 시스템 개발 I - X선 촬영법을 이용한 목재의 밀도 측정 -)

  • Kim, Kwang-Mo;Lee, Sang-Joon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.15-22
    • /
    • 2006
  • ln order to manage efficiently many ancient wooden buildings, which have been preserved as cultural properties in Korea, the internal state of wood members should be evaluated exactly and periodically by a NDE (non-destructive evaluation) method. A research project was planned to develop an X-ray CT (computed tomography) system as a NDE method for wood, which could be easily applied in field. This paper includes the first part of this project. First of all, to establish a measuring procedure of wood density using X-ray radiography, the correlation between X-ray intensity and the film brightness was evaluated. Also, initial X-ray intensity was quantified with various radiate conditions controlled by the tube voltage and tube current. And then, the effects of density, annual ring angle, and thickness on the mass attenuation coefficient of wood were examined. Finally, Beer's law was modified with the above results and adopted to calculate the density of wood. As a result of this study, the measuring procedure of wood density was established using a portable soft X-ray device and this procedure was verified with some small wood specimens. This results will he used valuably for the following researches to develop a portable X-ray CT system.

Evaluation of Effectiveness of New Design Lead Apron during Pregnant X-ray Chest P-A (임산부 흉부 촬영중 사용할 새로 디자인된 납치마의 효율성 평가)

  • Kim, Hyeonggyun;Kwon, Soonmu;Jung, Hongmoon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.441-445
    • /
    • 2012
  • X-ray Chest P-A is very important and basic diagnosis examination for pregnant women. For a pregnancy period pregnant women should be treated very carefully not to be exposed to any radiation which might cause harmful damage to women and babies as well. Lead apron is one of the effective methods to protect pregnant women from the X-ray radiation. However, it is difficult to obtain the accurate position of pregnant women during X-ray Chest P-A since conventional lead apron method forces pregnant women to hold the apron by themselves only to make pregnant women very uncomfortable and hard to maintain accurate position during radiation. As a consequence, it is common to get low quality images of X-ray Chest P-A due to the overlap of apex of lung and scapular. In order to fix this problem, we made new design lead apron that allowed pregnant women to be more comfortable to maintain accurate position during X-ray Chest P-A position. Finally, with this new design lead apron, it was possible to get the best optimized images of X-ray Chest P-A of pregnant women by minimizing overlapping apex of lung and scapular.

A Study about Reduction Method of the X-Ray Film Image (X선 사진의 감력법에 대한 실험 고찰)

  • Lee, Sang-Suk
    • Journal of radiological science and technology
    • /
    • v.14 no.2
    • /
    • pp.55-55
    • /
    • 1991
  • I reduced overexposed X-Ray film image with farmer reduction method and $KMnO_4$ reduction method. The results are as follows : 1. In farmer reduction method, there appears linear decreasing film image density. 2. In $KMnO_4$ reduction method, there appears over proportional reduction. 3. When red prussiate is compared with $KMnO_4$ reduction method, the latter shows more intense reduction. 4. If the reduction solution isn't used within 10 minutes after dilution, it becomes oxidized and the ability is decreased remarkably.

  • PDF

The analytical application for cement using X-Ray diffraction and X-Ray fluorescence spectrometer (X-Ray Diffraction과 X-Ray Fluorescence를 이용한 시멘트 비교 분석)

  • Jung, Ji Eun;Jang, Yu Rim;Kim, Ki-Wook;Heo, Sangcheol;Min, Ji-Sook
    • Analytical Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.340-351
    • /
    • 2013
  • The chemical element and structural characterization of different types of cements and its brick stones are been investigated under forensic aspects using X-ray florescence (XRF) and X-ray diffraction (XRD) spectrometer. The XRF provides rapid compositional data for controlling almost all stages of raw materials, clinker and cement. The decisive advantage of XRD methods is based on the unique character of the diffraction patterns of crystalline substances, the ability to distinguish between elements and their oxides, and the possibility to identify chemical compounds, polymeric forms, and mixed crystals by non-destructive examination. Therefore, combination of these examinations is useful and able to apply for the forensic analysis in comparison of cements and brick stones. There are more study remained to determine the viability of method for forensic analysis of brick stones and the limits of the discrimination that can be achieved.

Monte carlo estimation of activation products induced in concrete shielding around electron linac used in an X-ray container inspection system (X-ray 컨테이너 화물검색시스템의 전자선형가속기 주변 콘크리트 차폐벽 내 방사화생성물에 대한 몬테카를로법 평가)

  • Cho, Young-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.1035-1039
    • /
    • 2010
  • Activation products generated by photoneutrons in concrete shielding wall around electron linac were estimated for a high energy X-ray container cargo inspection system. Monte carlo code, MCNPX2.5.0 was used for reference system of 9MeV fixed type dual-direction container cargo inspection system installed at major harbors in Korea. Activation products inventory generated by photoneutron (n,$\gamma$) reaction are estimated, and then radiation dose rate is calculated from the results.

An empirical study on the X-ray attenuation capability of n-WO3/n-Bi2O3/PVA with added starch

  • Oliver, Namuwonge;Ramli, Ramzun Maizan;Azman, Nurul Zahirah Noor
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3459-3469
    • /
    • 2022
  • Matrix composites of n-WO3/n-Bi2O3/PVA with different loadings of n-WO3/n-Bi2O3 mixtures (0-15 wt%) and starch (0 and 3 wt%) were fabricated by using melt-mixing method. The X-ray attenuation capability were evaluated based on mass attenuation coefficient (μ/⍴) using a general diagnostic X-ray machine at 40-100 kVp. The effect of starch addition on the dispersion of the fillers in the PVA matrix were observed by using FESEM through morphological analysis. The fabricated samples have shrunken and caused their thickness to be decreased (0.35 mm-0.55 mm) after the drying process even though fixed thickness (2.0 mm) was set initially. The density and HVL values of the samples with 3 wt% starch was seen lower than samples without starch (0 wt%), however the former have provided improvement in filler dispersion and better X-ray attenuation capability compared to the latter. As conclusion, the matrix composite of n-WO3/n-Bi2O3/PVA with 15 wt% of n-Bi2O3, 8 wt% of n-WO3 and 3 wt% starch can be selected as the best promising candidate for X-ray shielding materials.

Development of Knot Quantification Method to Predict Bending Strength Using X-ray Scanner

  • Oh, Jung-Kwon;Kim, Kwang-Mo;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.5
    • /
    • pp.33-41
    • /
    • 2008
  • This study was aimed to develop the knot quantification method to predict bending strength, using x-ray scanner. The bending strength prediction model was proposed in this paper. The model was based on Knot Depth Ratio (KDR) and closely-spaced knot was taken into account. The previous paper reported that KDR is the ratio of the knot and transit zone to the lumber thickness. Even though KDR involves transit zone, it was verified that the ratio of the moment of inertia for knot to gross cross section ($I_k/I_g$) based on KDR was a good predictor for bending strength of lumber. To take closely-spaced knot into account, a projection method was also proposed. This projection method improved the predictive accuracy significantly. It showed coefficient of determinant of 0.65 and root mean square error (RMSE) of 9.17.

Development of High Voltage Generator for Diagnostic X-ray Equipment (진단용 X선 기기의 고전압 발생장치 개발)

  • Kim, Young-Pyo;Kim, Tae-Gon;Cheon, Min-Woo;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.764-765
    • /
    • 2010
  • The medical treatment X-ray machineries used in diagnosis of the human body is possible to diagnosis inside of the human body with the method of noninvasive so that it has shared a very important role in diagnosis from the medical institution. High voltage occurrence system which is most important in occurrence of X-ray has mainly been used the existing type of high voltage transformer, however it has a low efficiency of X-ray occurrence since it is a big and heavy, and a high ripple ratio of the direct current high voltage come to the X-ray tube. In order to solve this problem, the research has been advanced about the high voltage power supply system, and the inverter type of the high voltage occurrence system which occurs a high voltage by increasing the power frequency from about ten times to about hundred times with the inverter has currently used mainly. Also, the operation of tube voltage and tube current was controlled by using PWM method and the operation results were identified using an oscilloscope.

  • PDF