• Title/Summary/Keyword: X-ray Table

Search Result 74, Processing Time 0.026 seconds

The investigation of the exposure dose reduction of the Staff according to the Lead Curtain installation in EVAR(Endovascular Aneurysm Repair) surgical operation using C-arm (C-arm을 이용한 EVAR(Endovascular Aneurysm Repair) 시술시 Lead Curtain 설치에 따른 Staff의 피폭선량 감소에 대한 연구)

  • Yoo, In Woung;Chung, Jea Yeon;Lee, Kwan Seob
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.33-38
    • /
    • 2012
  • In EVAR procedure using long time C-arm, we studied exposure dose reduction and effeciency through measuring surgical staff's ESD by installing lead curtain operating table next to. The height 3 the spot (50cm, 100cm, 150cm) dose was measured on 2 locations for 600sec in the X-ray radiation considering the surgical staff's movement. To install the curtains, we compared before and after the dose. As a result, it can confirm that dose of the installation former of 50cm height and after is reduced about 75% and 91% in 2 locations. In 100cm height, the reduction of the dose was a bit confirmed. There as to dose value, measured on 150cm height the installation former and after was nearly no change. This research examined the exposure dose about the radiation of the surgical staff during EVAR procedure in which the operation time is the long time. It was implemented in the object that it reduces the radiation exposure. It could confirm the certain effect of the experimental result exposure dose reduction In EVAR procedure using long time C-arm, we studied exposure dose reduction and effeciency through measuring surgical staff's ESD by installing lead curtain operating table next to. The height 3 the spot (50cm, 100cm, 150cm) dose was measured on 2 locations for 600sec in the X-ray radiation considering the surgical staff's movement. To install the curtains, we compared before and after the dose. As a result, it can confirm that dose of the installation former of 50cm height and after is reduced about 75% and 91% in 2 locations. In 100cm height, the reduction of the dose was a bit confirmed. There as to dose value, measured on 150cm height the installation former and after was nearly no change. This research examined the exposure dose about the radiation of the surgical staff during EVAR procedure in which the operation time is the long time. It was implemented in the object that it reduces the radiation exposure. It could confirm the certain effect of the experimental result exposure dose reduction.

  • PDF

Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography (복부 일반촬영시 초점-필름간거리 변화가 피폭선량 및 화질에 미치는 영향)

  • Kim, You-Hyun;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.52-58
    • /
    • 1998
  • We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.

  • PDF

Change of Dose Distribution on the Beam Axis of 60Co γ Ray and 10MV X-Ray with Part Thickness (치료부위(治療部位)두께에 따른 Co-60 γ선(線)과 10MV X선(線)의 선축상(線軸上) 선량분포(線量分布)의 변화(變化))

  • Kang, Wee Saing;Koh, Kyoung Hwan;Ha, Sung Whan;Park, Charn Il
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.21-24
    • /
    • 1983
  • The thickness of the part being irradiated is finite. Percent depth dose tables being used routinely are generally obtained from dosimetry in a phantom much thickner than usual patient. At or close to exit surface, the dose should be less than that obtained from the percent depth dose tables, because of insufficient volume for backscattering. To know the difference between the true absorbed dose and the dose obtained from percent depth dose table, the doses at or close to the exit surface were measured with plate type ionization chamber with volume of 0.5ml. The results are as follows; 1. In the case of $^{60}Co$, percent depth dose at a given depth increases with underlying phantom thickness up to the 5cm. 2. In the case of $^{60}Co$, the dose correction factor at exit surface which is less than 1, increases with part thickness and decreases with field size. 3. Exposure time may not be corrected when the part above 10cm in thickness is treated by $^{60}Co$. 4. In the case of 10MV x-ray, the dose correction factor is nearly 1 and constant for the underlying phantom thickness and field size, so the correction of monitor unit is not necessary for part thickness.

  • PDF

Comparative Analysis of Absorption Doses between Exposed and Unexposed Area on Major Organs During CT Scan (전산화 단층촬영시 주선속내 외의 주요장기 흡수선량 비교분석)

  • 사정호;서태석;최보영;정규회
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.59-71
    • /
    • 2000
  • It is possible to obtain a fast CT scan during breath holding with spiral technique. But the risk of radiation is increased due to detailed and repeated scans. However, the limitation of X-ray doses is not fully specified on CT, yet. Therefore, the purpose of the present study is to define the limitation of X-ray doses on CT The CT unit was somatom plus 4. Alderson Rando phantom, Solenoid water phantom, TLD, and reader were used. For determining adequate position and size of organs, the measurement of distance(${\pm}$2mm) from the midline of vertebral body was performed in 40 women(20~40 years). On the brain scan for 8:8(8mm slice thickness, 8mm/sec movement velocity of the table) and 10:10(10mm slice thickness, 10mm/sec movement velocity of the table) methods, the absorption doses of exposed area of the 10:10 were slightly higher than those of 8:8. The doses of unexposed uterus were negligible on the brain scan for both 8:8 and 10:10. On the chest scan for 8:8, 8:10(8mm slice thickness, 10mm/sec movement velocity of the table), 10:10, 10:12(10mm slice thickness, 12mm/sec movement velocity of the table) and 10:15(10mm slice thickness, 15mm/sec movement velocity of the table) methods, 8:8 method of the absorption doses of exposure area was the most highest and 10:15 method was the most lowest. The absorption doses of 8:10 method was relatively lower than those of the other methods. In conclusion, the 8:10 method is the most suitable to give a low radiation burden to patient without distorting image quality.

  • PDF

Survery on Business of the Departments of Radiology in Health Centers (보건소(保健所)의 방사선과(放射線科) 업무(業務)에 관한 조사연구(調査硏究))

  • Choi, Jong-Hak;Jeon, Man-Jin;Huh, Joon;Park, Sung-Ock
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.21-28
    • /
    • 1985
  • We serveyed the actual condition of business of the departments of radiology of 45 health conters (except 3) in the area of Seoul, Kyungki and Inchon from March, 1984 to November, 1984. The results are summarized as follows : 1. T.O. of the radiologic technologist is three persons in each health center of Seoul area, and one person in each one of Kyungki and Inchon area. P.O. is 2-5 persons in Seoul area, 1-2 persons in Kyungki or Inchon area. 2. The number of all the radiologic technologists employed now is 75 persons, and among all of them, when analized by position class 7th is 54.7%, class 8th 28.0%, class 9th is 13.3%, and class 6th is 2.7%, and by sex, female is 68.0%, male is 32.0%, by educational background, for the most part, junior college graduates come to 73.3%, by age group 60% of them is in their twenties, 16.0% is in their thirties and forties, 8.0% is in their fifties, and by career after certificate 60% have the career of 1-5 years, 13.3% have the one of 6-7 years or mor than 21 years, and 6.7% have the one of 11-15 years of 16-20 years. 3. All the diagnostic x-ray equipment being kept is 62, and among them flxing equipment is 71.0%, portable equipment is 29.0% and by rating of X-ray equipment, maximum tube current 100 mA is 46.8%, maximum KV 100KVP is 72.6%, the most part. 4. Photofluorographic camera and hood are equipped in every health center. While, as to the radiographic cassettes, $14{\times}14"$ cassetts are equipped in every health center, but cassettes of other sizes are in half of them. 5. Bucky's table is equipped in 11.9% health centers, the automatic processor is in 21.4%, the photofluorographic film changer is 9.5%, the grid is 73.8%, the protective apron is in 88.1%, and the protective glove is in 57.1% health centers. 6. The number of the people who got the x-ray examination for one year (by the year 1989) is the most, 1,000-6,000 in direct radiography of the chest, or 15,0001-45,000 in the health centers of Seoul area, 5,000-20,000 in Kyungki and Inchon area in photofluorography of the chest. Moreover, other radiographies are being taken extremely limitedly in all health centers. 7. In processing types of x-ray film, automatic processing is used in 9 health centers (21.4%), manual tank processing is in 30 (71.4%), and manual tray processing in 3 (7.2%). 8. As for collimation of x-ray exposure field, "continual using restricted by a subject size" has the most part, 78.6% "restricted using at every radiography" has 19%, and the case of "never considered" has 2.4% response. 9. As for the dosimeter used for radiation control, film badge (35.7%) and pocket dosimeter (26.2%) are used, and in 38.1% health centers the dosimeter is not equipped at all. Consideration of the previous radiation exposure is being done in only one health center. 10. Reading of radiographs is mainly depended on the radiologists electively (45.2%) or on the genral practitioners(45.2%).

  • PDF

Compressed-sensing (CS)-based Image Deblurring Scheme with a Total Variation Regularization Penalty for Improving Image Characteristics in Digital Tomosynthesis (DTS) (디지털 단층합성 X-선 영상의 화질개선을 위한 TV-압축센싱 기반 영상복원기법 연구)

  • Je, Uikyu;Kim, Kyuseok;Cho, Hyosung;Kim, Guna;Park, Soyoung;Lim, Hyunwoo;Park, Chulkyu;Park, Yeonok
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • In this work, we considered a compressed-sensing (CS)-based image deblurring scheme with a total-variation (TV) regularization penalty for improving image characteristics in digital tomosynthesis (DTS). We implemented the proposed image deblurring algorithm and performed a systematic simulation to demonstrate its viability. We also performed an experiment by using a table-top setup which consists of an x-ray tube operated at $90kV_p$, 6 mAs and a CMOS-type flat-panel detector having a $198-{\mu}m$ pixel resolution. In the both simulation and experiment, 51 projection images were taken with a tomographic angle range of ${\theta}=60^{\circ}$ and an angle step of ${\Delta}{\theta}=1.2^{\circ}$ and then deblurred by using the proposed deblurring algorithm before performing the common filtered-backprojection (FBP)-based DTS reconstruction. According to our results, the image sharpness of the recovered x-ray images and the reconstructed DTS images were significantly improved and the cross-plane spatial resolution in DTS was also improved by a factor of about 1.4. Thus the proposed deblurring scheme appears to be effective for the blurring problems in both conventional radiography and DTS and is applicable to improve the present image characteristics.

Comparison of $^{67}Ga$ Planar Imaging and SPECT for the Evaluation of Activity in Undetermined Minimal Pulmonary Tuberculosis (흉부 X-선상 활동성 미정으로 판독된 경증 폐결핵 환자에서 활동성 판정에 대한 $^{67}Ga$ 평면영상과 SPECT의 비교분석)

  • An, Min;Chang, Won-Kyu;Kim, Kyoung-Gon;Kim, Sung-Min;Kim, Yun-Kwon;Kim, So-Yeon;Kim, Young-Jung;Park, Byung-Yik;Cho, Min-Koo;Lee, Gwon-Jun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.6
    • /
    • pp.870-878
    • /
    • 2000
  • Background : We have studied the $^{67}Ga$ SPECT to determine the activity of pulmonary tuberculosis, especially in patients with minimal extent of the disease on chest radiographs. Because active minimal pulmonary tuberculosis is sometimes difficult to diagnose by means of initial chest X-ray, sputum examination and $^{67}Ga$ planar imaging, we compared $^{67}Ga$ planar imaging with SPECT to evaluate minimal pulmonary tuberculosis activity. Methods : $^{67}Ga$ planar imagings and SPECTs of 69 patients suspected of minimal pulmonary tuberculosis by the initial chest X-ray were performed and compared to each other. Active pulmonary tuberculosis was defined by a positive AFB smear and/or culture in the sputum and changes shown on the serial chest X-ray findings. Results : 1) $^{67}Ga$ planar imaging imagings showed positive uptakes in 24 patients and no uptakes in 13 patients, patients, which confirms active pulmonary tuberculosis. But SPECT imagings showed positive uptakes in 25 patients and no uptakes in 12 patients. 2) Patients confirmed with inactive pulmonary tuberculosis showed no uptake on $^{67}Ga$ planar imaging. Only one of the 32 patients confirmed as having inactive pulmonary tuberculosis showed positive uptake on $^{67}Ga$ SPECT imaging. Conclusions : According to the results of our study, $^{67}Ga$ planar imaging and SPECT are both sensitive in detecting the activity of minimal pulmonary tuberculosis. The difference between the two methods is not statistically significant, and the negative predictive value of the $^{67}Ga$ SPECT is not higher than that of $^{67}Ga$ planar imaging.

  • PDF

How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions?

  • Kim, Ah Na;Chang, Young Jae;Cheon, Bo Kyung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.27 no.2
    • /
    • pp.145-151
    • /
    • 2014
  • Background: The physician's hands are close to the X-ray field in C-arm fluoroscopy-guided pain interventions. We prospectively investigated the radiation attenuation of Proguard RR-2 gloves. Methods: In 100 cases, the effective doses (EDs) of two dosimeters without a radiation-reducing glove were collected. EDs from the two dosimeters-one dosimeter wrapped with a glove and the other dosimeter without a glove-were also measured at the side of the table (Group 1, 140 cases) and at a location 20 cm away from the side of the table (Group 2, 120 cases). Mean differences such as age, height, weight, radiation absorbed dose (RAD), exposure time, ED, and ratio of EDs were analyzed. Results: In the EDs of two dosimeters without gloves, there were no significant differences ($39.0{\pm}36.3{\mu}Sv$ vs. $38.8{\pm}36.4{\mu}Sv$) (P = 0.578). The RAD ($192.0{\pm}182.0radcm^2$) in Group 2 was higher than that ($132.3{\pm}103.5radcm^2$) in Group 1 (P = 0.002). The ED ($33.3{\pm}30.9{\mu}Sv$) of the dosimeter without a glove in Group 1 was higher than that ($12.3{\pm}8.8{\mu}Sv$) in Group 2 (P < 0.001). The ED ($24.4{\pm}22.4{\mu}Sv$) of the dosimeter wrapped with a glove in Group 1 was higher than that ($9.2{\pm}6.8{\mu}Sv$) in Group 2 (P < 0.001). No significant differences were noted in the ratio of EDs ($73.5{\pm}6.7%$ vs. $74.2{\pm}9.3%$, P = 0.469) between Group 1 and Group 2. Conclusions: Proguard RR-2 gloves have a radiation attenuation effect of 25.8-26.5%. The radiation attenuation is not significantly different by intensity of scatter radiation or the different RADs of C-arm fluoroscopy.

Spatial Dose Distribution for C-arm Examination within Operation Room Using Monte Carlo Method (몬테카를로 방법을 이용한 이동형 X선 투시검사 시 수술실 내 공간선량평가)

  • Kim, Jung-Hoon;Shin, Eom-Hyeon
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.205-210
    • /
    • 2021
  • The purpose of this study was to analyze the spatial dose according to the distance by location of medical workers when using a mobile X-ray fluoroscopy device in the operating room through a simulation experiment. The MCNPX program was used for the simulation, and the location of medical workers was set around the operating table, and the spatial dose distribution according to the distance and changes in imaging conditions was evaluated. As a result, The highest score was 2.74×10-4 mGy, 2.72×10-4 mGy, and 1.18×10-4 mGy based on the 10 cm distance from the operating table. Spatial dose depending on the distance 100cm, A point 5.15×10-5 mGy is decreased 19% of 10cm, D point 5.12×10-5 mGy, 19 % of 10cm, and G pint, 1.73×10-5 mGy is reduced by 15% of 10cm. Based on this study, medical-related workers directly or indirectly participating in surgery carry potential risks of radiation exposure during surgery, but there are difficulties in radiation protection due to the nature of their work. Therefore, efforts to reduce exposure suitable for the operating room environment will be required.

Evaluation of Approximate Exposure to Low-dose Ionizing Radiation from Medical Images using a Computed Radiography (CR) System (전산화 방사선촬영(CR) 시스템을 이용한 근사적 의료 피폭 선량 평가)

  • Yu, Minsun;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.455-464
    • /
    • 2012
  • This study suggested evaluation of approximately exposure to low-dose ionization radiation from medical images using a computed radiography (CR) system in standard X-ray examination and experimental model can compare diagnostic reference level (DRL) will suggest on optimization condition of guard about medical radiation of low dose space. Entrance surface dose (ESD) cross-measuring by standard dosimeter and optically stimulated luminescence dosimeters (OSLDs) in experiment condition about tube voltage and current of X-ray generator. Also, Hounsfield unit (HU) scale measured about each experiment condition in CR system and after character relationship table and graph tabulate about ESD and HU scale, approximately radiation dose about head, neck, thoracic, abdomen, and pelvis draw a measurement. In result measuring head, neck, thoracic, abdomen, and pelvis, average of ESD is 2.10, 2.01, 1.13, 2.97, and 1.95 mGy, respectively. HU scale is $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, and $2,318{\pm}4.64$, respectively, in CR image. At this moment, using characteristic relationship table and graph, ESD measured approximately 2.16, 2.06, 1.19, 3.05, and 2.07 mGy, respectively. Average error of measuring value and ESD measured approximately smaller than 3%, this have credibility cover all the bases radiology area of measurement 5%. In its final analysis, this study suggest new experimental model approximately can assess radiation dose of patient in standard X-ray examination and can apply to CR examination, digital radiography and even film-cassette system.