Development of a Cantilevered Patient Table Considering X-ray Transparency (X-선 투과특성을 고려한 외주형 수술용 테이블 개발)

  • Won B.H.;Chun K.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.189-190
    • /
    • 2006
  • A patient table considering x-ray transparency, mechanical safety and compact multi-axis moving mechanism has been developed. The goal of medical imaging technology is to keep radiation exposure of patients during x-raying to a minimum. In order to obtain clear pictures at low dose, however, the x-ray table which supports the patient must be sufficiently permeable to radiation to allow good image resolution. The table top is made of low density foam for x-ray transparent effective area and structural aluminum plate to connect moving mechanism under the table, covered with thin carbon fiber. This sandwich construction is very rigid and lightweight, so the table top can handle relatively heavy load comparing to its cantilevered structure which is unavoidable as long as cooperate with C-arm radiography. To verify the design results finite element static analysis and experimental tests have been done. According to the verification the results well satisfy certification guide lines as a medical device.

  • PDF

Design for Adhesive Carbon Heating Element X-ray Table with an Attached Heating Device (가열장치를 구비한 부착형 탄소발열체 X선 촬영대 고안)

  • Song, Jongnam;Kim, Eungkon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.131-137
    • /
    • 2015
  • The purpose of this study is to warm up the conventional X-ray table by inventing and design for X-ray table with an attached heating device using less unloaded X-ray, CNT (carbon nano tube) heating element. Configuration of the product design for adhesive carbon heating element X-ray is composed of a conventional X-ray table, carbon nano tube planar heating element, an electrode line, flame resisting protective film, and the bottom film. Characteristics and advantages of this invented product is to provide gentle feeling, the sense of security, and eliminating anxiety to the patient wearing a patient gown and feel the cool air while receiving the test. Thus we are strongly recommend to use this device in the clinical situation.

Charateristics of 10MV X-ray Beam from a Mevatron KD Linear Accelerator (Mevatron KD 선형 가속기에서의 10MV X-선 특성)

  • Yi, Byong-Yong;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.6 no.1
    • /
    • pp.101-108
    • /
    • 1988
  • The beam characteristics and dosimetric measurements of the 10MV X-ray beam from a Mevatron KD linear accelerator are examined. The Percent Depth Dose (POD) table and the Tissue Maximum Ratio (TMR) table are taken from measurement as a function of the field size and the depth. The calculated TMR table from PDD table is compared with those from measurement. Other beam characteristics such as output factor, beam profile (including flatness, symmetry and penumbra), wedge, and the variation of Dmax are presented.

  • PDF

The Adequacy of a Cross Table Lateral Cervical X-ray in Severely Traumatized Korean Patients (한국인 중증 외상 환자에서 촬영한 경추 외측면 단순 방사선 영상의 적절성)

  • Lee, Kyung-Hag;Kim, Yeong Cheol;Choi, Seok Ho;Han, Gook Nam;Lee, Soo Un;Lee, Jung Eun;Suh, Gil Joon;Yoon, Yeo-Kyu
    • Journal of Trauma and Injury
    • /
    • v.25 no.4
    • /
    • pp.241-246
    • /
    • 2012
  • Purpose: The objective of this study was to investigate the appropriateness of the cross table lateral cervical X-ray used in the emergency department for severely traumatized Korean patients. Methods: Patients visiting our institution from May 2011 to May 2012, who had injury severity score (ISS) > 15 and who received a cervical X-ray in the emergency department, were included in this study. Data including demographics, ISS score, GCS score, and place where the x-ray was taken were collected to evaluate their relationship with appropriate coverage of the cervical X-ray. The appropriateness of a cervical cross lateral view X-ray was evaluated using exposure of the basion, and the opisthion, as well as the distal level of exposure. Results: Fifty-two patients were included in this study. The identification rate of the basion was 79.2%, and the identification rate of the opisthion was 88.7%. Complete exposure of C7/T1 was accomplished in 3.8% of the patients. The ISS was higher for X-ray taken in the trauma bay, but the range of exposure showed no difference between the places where the X-rays taken. Patients who had exposure of C 5/6 or more had lower body weight and body mass index (BMI) compared with unexposed patients. Conclusion: In severely traumatized Korean patients, the adequacy of the cross table lateral cervical X-ray was inappropriate in most cases. No difference was observed in the exposure range between the places where the X-rays were taken, and patients with less exposure showed higher body weight and higher BMI.

Development of High Resolution Micro-CT System for In Vivo Small Animal Imaging (소형 동물의 생체 촬영을 위한 고해상도 Micro-CT 시스템의 개발)

  • Park, Jeong-Jin;Lee, Soo-Yeol;Cho, Min-Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.95-101
    • /
    • 2007
  • Recently, small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals such as mice and rats. One of newly developed imaging modalities for small animals is an x-ray micro-CT (computed tomography). We have developed two types of x-ray micro-CT systems for small animal imaging. Both systems use flat-panel x-ray detectors and micro-focus x-ray sources to obtain high spatial resolution of $10{\mu}m$. In spite of the relatively large field-of-view (FOV) of flat-panel detectors, the spatial resolution in the whole-body imaging of rats should be sacrificed down to the order of $100{\mu}m$ due to the limited number of x-ray detector pixels. Though the spatial resolution of cone-beam CTs can be improved by moving an object toward an x-ray source, the FOV should be reduced and the object size is also limited. To overcome the limitation of the object size and resolution, we introduce zoom-in micro-tomography for high-resolution imaging of a local region-of-interest (ROI) inside a large object. For zoom-in imaging, we use two kinds of projection data in combination, one from a full FOV scan of the whole object and the other from a limited FOV scan of the ROI. Both of our micro-CT systems have zoom-in micro-tomography capability. One of both is a micro-CT system with a fixed gantry mounted with an x-ray source and a detector. An imaged object is laid on a rotating table between a source and a detector. The other micro-CT system has a rotating gantry with a fixed object table, which makes whole scans without rotating an object. In this paper, we report the results of in vivo small animal study using the developed micro-CTs.

Distribution of the Scatter Ray in Fluoroscopy X-ray Room (투시 검사실 내 공간산란선 분포 측정)

  • Cho, Pyong-Kon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.349-354
    • /
    • 2011
  • The results of the scattery distribution in the fluoroscopy X-ray room were as follows. When the measurement was done at the same height with the table, measured value was 0.78 mGy/min ~ 0.04 mGy/min (95%) within 50 cm and 250 cm. At 50 cm below the table, it was 0.17 mGy/min ~ 0.02mGy/min (86%) and at 50 cm above the table was 1.37 mGy/min ~ 0.05 mGy/min (96%), displaying a decrease. At the same time, the amount of rays were reduced in 50 ~ 60% at the same height with the table than the location 50 cm above the table, 90~95% of reduction rate was observed at 50 cm below the table. For the collimator, comparing to the case when it was completely open, the amount of ray was reduced from 0.78 mGy/min to 0.16 mGy/min at 50cm away and 0.04 mGy/min to 0.01 mGy/min at 250cm away thus approximately 80% on average was reduced when the collimator was reduced to 25%. Comparing with the case when there was a object on the table, the amount of scatter ray was reduced by 96.7% at every location when there is not a object on the table.

Evaluation of Image Quality according to the Use of Attachable X-ray Table Equipped with Heating Device (가열장치를 구비한 부착형 X선 촬영대의 사용에 따른 화질 평가)

  • Song, Jongnam;Kim, Eungkon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.219-225
    • /
    • 2015
  • This study aims to evaluates the image quality of CR and DR that are scanned with the use of the attachable carbon heater X-ray scanner table equipped with heating device by measuring SNR and CNR before and after the attachment of the said table. In the aluminum staircase testing, CR increased SNR and CNR when attached with the table, while DR decreased SNR and CNR. In the human-body model phantom testing, CR increased SNR and CNR only in the low-energy low-dose radiation and the high-energy high-dose radiation, but decreased SNR and CNR under all other conditions. In conclusion, the use of such table can make the patient feel comfortable by removing his or her anxiety, thus helping the testing, but in the actual clinical application thereof, if the thickness and material of the bottom film and the protective film, including the carbon heater, are not considered, it affects the picture quality, thereby requiring continuous research on the use of such table.

3D Coordinates Acquisition by using Multi-view X-ray Images (다시점 X선 영상을 이용한 3차원 좌표 획득)

  • Yi, Sooyeong;Rhi, Jaeyoung;Kim, Soonchul;Lee, Jeonggyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.10
    • /
    • pp.886-890
    • /
    • 2013
  • In this paper, a 3D coordinates acquisition method for a mechanical assembly is developed by using multiview X-ray images. The multi-view X-ray images of an object are obtained by a rotary table. From the rotation transformation, it is possible to obtain the 3D coordinates of corresponding edge points on multi-view X-ray images by triangulation. The edge detection algorithm in this paper is based on the attenuation characteristic of the X-ray. The 3D coordinates of the object points are represented on a graphic display, which is used for the inspection of a mechanical assembly.

Usefulness Evaluation of Merchant Auxiliary Equipment of Body Type Changing Suitable for X-ray Table Integral Type (체형변화에 적합한 X-선 검사대 일체형 Merchant 보조장비의 유용성 평가)

  • Seoung, Youl-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2773-2779
    • /
    • 2013
  • The purpose of this study was to evaluate of the usefulness and to develop new auxiliary equipment that can bending angle of the bone of the knee various depending on the thickness of the thigh of the human. The subjects agreed for research purposes and were selected from normal person who do not have past knee-related diseases and grouped thin group A and thick group B for the thigh. We set in order to obtain images in the axial direction of the bones of the knee, $35^{\circ}$ to increase by $5^{\circ}$ angle of knee flexion, $45^{\circ}$, to $55^{\circ}$, and we performed combinations of 9 tests by incident angle X-ray per each angle, $40^{\circ}$, $50^{\circ}$ and $60^{\circ}$. As a result, we have developed an Merchant auxillary equipment of X-ray table integral type in radiographic images which was easy to use and could take images of various integral knee joint angles adjusting different body types. Using the auxiliary equipment, in the case of X-ray incident angle $50^{\circ}$ and $60^{\circ}$ with the knee flexion angle of $40^{\circ}$ in group A, and in group B, Knee flexion angle of $45^{\circ}$ and $35^{\circ}$, the X-ray incident angle at $60^{\circ}$, excellent images were derived. Future, it would be very useful in the examination of patients with a variety of body types.