• Title/Summary/Keyword: X-ray PTV

Search Result 11, Processing Time 0.027 seconds

Simultaneous Measurement of Size and Velocity of Microbubbles inside Opaque Tube Using X-ray PTV Technique (X-ray PTV 기법을 이용한 불투명 튜브 내부의 미세기포의 크기 및 속도 동시 측정)

  • Kim, Seok;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.2
    • /
    • pp.69-75
    • /
    • 2006
  • The microbubbles were used in various fields, such as turbulent control, drag reduction, material science and life science. The X-ray PTV using X-ray micro-imaging technique was employed to mea-sure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Micro-bubbles of $10{\sim}60{\mu}m$ diameter moving upward in an opaque tube (${\phi}$=2.7mm) were tested. Due to the different refractive indices of water and air, phase contrast X-ray images clearly show the exact size and shape of over-lapped microbubbles. In all of the working fluids tested (deionized water, tap water, 0.01 and 0.10M NaCl solutions), the measured terminal velocity of the microbubbles rising through the solution was proportional to the square of the bubble diameter. The rising velocity was increased with increasing mole concentration. The microbubble can be useful as contrast agent or tracer in life science and biology. The X-ray PTV technique should be able to extract useful information on the behavior of various bio/microscale fluid flows that are not amenable to analysis using conventional methods.

  • PDF

Advanced Flow Visualization Techniques for Diagnosing Microscale Biofluid Flows (미세 생체유동 해석을 위한 첨단 유동가시화기법)

  • Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • Recently microscale biofluid flows have been receiving large attention in various research areas. However, most conventional imaging techniques are unsatisfactory due to difficulties encountered in the visualization of microscale biological flows. Recent advances in optics and digital image processing techniques have made it possible to develop several advanced micro-PIV/PTV techniques. They can be used to get quantitative velocity field information of various biofluid flows from visualized images of tracer particles. In this paper, as new advanced micro-PIV techniques suitable for biofluid flow analysis, the basic principle and typical applications of the time-resolved micro-PIV and X-ray micro-PIV methods are explained. As a 3D velocity field measurement technique for measuring microscale flows, holographic micro-PTV method is introduced. These advanced PIV/PTV techniques can be used to reveal the basic physics of various microscale biological flows and will play an important role in visualizing veiled biofluid flow phenomena, for which conventional methods have many difficulties to analyze.

Intensity Modulated Radiation Therapy of Brain Tumor

  • Kim, Sung-Kyu;Kim, Myung-Se
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.61-64
    • /
    • 2002
  • As intensity modulated radiation therapy compared with conventional radiation therapy, tumor target dose increased and normal tissues and critical organs dose reduced. In brain tumor, treatment planning of intensity modulated radiation therapy was practiced in 4MV, 6MV, 15MV X-ray energy. In these X-ray energy, was considered the dose distribution and dose volume histogram. As 4MV X-ray compared with 6MV and 15MV, maximum dose of right optic-nerve increased 10.1 %, 8.4%. Right eye increased 5.2%, 2.7%. And left optic-nerve, left eye, optic chiasm and brainstem incrased 1.7% - 5.2%. Even though maximum dose of PTV and these critical organs show different from 1.7% - 10.1% according to X-ray energies, these are a piont dose. Therefore in brain tumor, treatment planning of intensity modulated radiation therapy in 9 treatment field showed no relation with energy dependency.

  • PDF

Study of Energy Dependency in Intensity Modulated Radiation Therapy of Brain Tumor (세기조절방사선치료를 이용한 뇌종양에서 에너지 의존성에 관한 연구)

  • 김성규
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.104-108
    • /
    • 2002
  • As intensity modulated radiation therapy compared with conventional radiation therapy, tumor target dose increased and normal tissues and critical organs dose reduced. In brain tumor, treatment planning of intensity modulated radiation therapy was practiced in 4MV, 6MV, 15MV X-ray energy. In these X-ray energy, was considered the dose distribution and dose volume histogram. As 4MV X-ray compared with 6MV and 15MV, maximum dose of right optic-nerve increased 10.1%, 8.4%. Right eye increased 5.2%, 2.7%. And left optic-nerve, left eye, optic chiasm and brainstem increased 1.7% - 5.2%. Even though maximum dose of PTV and these critical organs show different from 1.7% - 10.1% according to X-ray energies, these are a piont dose. Therefore in brain tumor, treatment planning of intensity modulated radiation therapy in 9 treatment field showed no relation with energy dependency.

  • PDF

Comparison of Dose Distributions Calculated by Anisotropic Analytical Algorithm and Pencil Beam Convolution Algorithm at Tumors Located in Liver Dome Site (간원개에 위치한 종양에 대한 Anisotropic Analyticalal Algorithm과 Pencil Beam Convolution 알고리즘에 따른 전달선량 비교)

  • Park, Byung-Do;Jung, Sang-Hoon;Park, Sung-Ho;Kwak, Jeong-Won;Kim, Jong-Hoon;Yoon, Sang-Min;Ahn, Seung-Do
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.106-113
    • /
    • 2012
  • The purpose of this study is to evaluate the variation of radiation dose distribution for liver tumor located in liver dome and for the interest organs(normal liver, kidney, stomach) with the pencil beam convolution (PBC) algorithm versus anisotropic Analyticalal algorithm (AAA) of the Varian Eclipse treatment planning system, The target volumes from 20 liver cancer patients were used to create treatment plans. Treatment plans for 10 patients were performed in Stereotactic Body Radiation Therapy (SBRT) plan and others were performed in 3 Dimensional Conformal Radiation Therapy (3DCRT) plan. dose calculation was recalculated by AAA algorithm after dose calculation was performed by PBC algorithm for 20 patients. Plans were optimized to 100% of the PTV by the Prescription Isodose in Dose Calculation with the PBC algorithm. Plans were recalculated with the AAA, retaining identical beam arrangements, monitor units, field weighting and collimator condition. In this study, Total PTV was to be statistically significant (SRS: p=0.018, 3DCRT: p=0.006) between PBC and AAA algorithm. and in the case of PTV, ITV in liver dome, plans for 3DCRT were to be statistically significant respectively (p=0.013, p=0.024). normal liver and kidney were to be statistically significant (p=0.009, p=0.037). For the predictive index of dose variation, CVF ratio was to be statistically significant for PTV in the liver dome versus PTV (SRS r=0.684, 3DCRT r=0.732, p<0.01) and CVF ratio for Tumor size was to be statistically significant (SRS r=-0.193, p=0.017, 3DCRT r=0.237, p=0.023).

A study on uncertainty by passage of time of stereotactic body radiation therapy for spine metastasis cancer (척추 전이암 환자의 정위적방사선치료 시 시간 경과에 따른 불확실성에 관한 연구)

  • Cho, Yong Wan;Kim, Joo Ho;Ahn, Seung Kwon;Lee, Sang Kyoo;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.79-86
    • /
    • 2015
  • Purpose : The purpose of this study was to determine the proper treatment time of stereotactic body radiation therapy for spine metastasis cancer by using the image guidance system of CyberKnife(Accuray Incorporated, USA) which is able to correct movements of patients during the treatment. Materials and Methods : Fifty seven spine metastasis cancer patients who have stereotactic body radiation therapy of CyberKnife participate, 8 of them with cervical spine cancer, 26 of them with thoracic spine cancer, and 23 of them with lumbar spine cancer. X-ray images acquired during the treatment were classified by treatment site. From the starting point of treatment, motion tendency of patients is analyzed in each section which is divided into every 5 minutes. Results : In case of cervical spine, there is sudden increase of variation in 15 minutes after the treatment starts in rotational direction. In case of thoracic spine, there is no significantly variable section. However, variation increases gradually with the passage of time so that it is assumed that noticeable value comes up in approximately 40 minutes. In case of lumbar spine, sharp increase of variation is seen in 20 minutes in translational and rotational direction. Conclusion : Without having corrections during the treatment, proper treatment time is considered as less than 15 minutes for cervical spine, 40 minutes for thoracic spine, and 20 minutes for lumbar spine. If treatment time is longer than these duration, additional patient alignments are required or PTV margin should be enlarged.

  • PDF

Comparison of Three- and Four-dimensional Robotic Radiotherapy Treatment Plans for Lung Cancers (폐암환자의 종양추적 정위방사선치료를 위한 삼차원 및 사차원 방사선치료계획의 비교)

  • Chai, Gyu-Young;Lim, Young-Kyung;Kang, Ki-Mun;Jeong, Bae-Gwon;Ha, In-Bong;Park, Kyung-Bum;Jung, Jin-Myung;Kim, Dong-Wook
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.238-248
    • /
    • 2010
  • Purpose: To compare the dose distributions between three-dimensional (3D) and four-dimensional (4D) radiation treatment plans calculated by Ray-tracing or the Monte Carlo algorithm, and to highlight the difference of dose calculation between two algorithms for lung heterogeneity correction in lung cancers. Materials and Methods: Prospectively gated 4D CTs in seven patients were obtained with a Brilliance CT64-Channel scanner along with a respiratory bellows gating device. After 4D treatment planning with the Ray Tracing algorithm in Multiplan 3.5.1, a CyberKnife stereotactic radiotherapy planning system, 3D Ray Tracing, 3D and 4D Monte Carlo dose calculations were performed under the same beam conditions (same number, directions, monitor units of beams). The 3D plan was performed in a primary CT image setting corresponding to middle phase expiration (50%). Relative dose coverage, D95 of gross tumor volume and planning target volume, maximum doses of tumor, and the spinal cord were compared for each plan, taking into consideration the tumor location. Results: According to the Monte Carlo calculations, mean tumor volume coverage of the 4D plans was 4.4% higher than the 3D plans when tumors were located in the lower lobes of the lung, but were 4.6% lower when tumors were located in the upper lobes of the lung. Similarly, the D95 of 4D plans was 4.8% higher than 3D plans when tumors were located in the lower lobes of lung, but was 1.7% lower when tumors were located in the upper lobes of lung. This tendency was also observed at the maximum dose of the spinal cord. Lastly, a 30% reduction in the PTV volume coverage was observed for the Monte Carlo calculation compared with the Ray-tracing calculation. Conclusion: 3D and 4D robotic radiotherapy treatment plans for lung cancers were compared according to a dosimetric viewpoint for a tumor and the spinal cord. The difference of tumor dose distributions between 3D and 4D treatment plans was only significant when large tumor movement and deformation was suspected. Therefore, 4D treatment planning is only necessary for large tumor motion and deformation. However, a Monte Carlo calculation is always necessary, independent of tumor motion in the lung.

Effects of recycling on the biomechanical characteristics of retrieved orthodontic miniscrews

  • Yun, Soon-Dong;Choi, Sung-Hwan;Cha, Jung-Yul;Yu, Hyung-Seog;Kim, Kwang-Mahn;Kim, Jin;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.47 no.4
    • /
    • pp.238-247
    • /
    • 2017
  • Objective: The aim of this study was to compare recycled and unused orthodontic miniscrews to determine the feasibility of reuse. The comparisons included both miniscrews with machined surfaces (MS), and those with etched surfaces (ES). Methods: Retrieved MS and ES were further divided into three subgroups according to the assigned recycling procedure: group A, air-water spray; group B, mechanical cleaning; and group C, mechanical and chemical cleaning. Unused screws were used as controls. Scanning electron microscopy, energy-dispersive X-ray spectrometry, insertion time and maximum insertion torque measurements in artificial bone, and biological responses in the form of periotest values (PTV), bone-implant contact ratio (BIC), and bone volume ratio (BV) were assessed. Results: Morphological changes after recycling mainly occurred at the screw tip, and the cortical bone penetration success rate of recycled screws was lower than that of unused screws. Retrieved ES needed more thorough cleaning than retrieved MS to produce a surface composition similar to that of unused screws. There were no significant differences in PTV or BIC between recycled and unused screws, while the BV of the former was significantly lower than that of the latter (p < 0.05). Conclusions: These results indicate that reuse of recycled orthodontic miniscrews may not be feasible from the biomechanical aspect.

Treatment Results of CyberKnife Radiosurgery for Patients with Primary or Recurrent Non-Small Cell Lung Cancer (원발 혹은 재발성 비소세포 폐암 환자에서 사이버나이프률 이용한 체부 방사선 수술의 치료 결과)

  • Kim, Woo-Chul;Kim, Hun-Jung;Park, Jeong-Hoon;Huh, Hyun-Do;Choi, Sang-Huoun
    • Radiation Oncology Journal
    • /
    • v.29 no.1
    • /
    • pp.28-35
    • /
    • 2011
  • Purpose: Recently, the use of radiosurgery as a local therapy in patients with early stage non-small cell lung cancer has become favored over surgical resection. To evaluate the efficacy of radiosurgery, we analyzed the results of stereotactic body radiosurgery in patients with primary or recurrent non-small cell lung cancer. Materials and Methods: We reviewed medical records retrospectively of total 24 patients (28 lesions) with non-small cell lung cancer (NSCLC) who received stereotactic body radiosurgery (SBRT) at Inha University Hospital. Among the 24 patients, 19 had primary NSCLC and five exhibited recurrent disease, with three at previously treated areas. Four patients with primary NSCLC received SBRT after conventional radiation therapy as a boost treatment. The initial stages were IA in 7, IB in 3, IIA in 2, IIB in 2, IIIA in 3, IIIB in 1, and IV in 6. The T stages at SBRT were T1 lesion in 13, T2 lesion in 12, and T3 lesion in 3. 6MV X-ray treatment was used for SBRT, and the prescribed dose was 15~60 Gy (median: 50 Gy) for PTV1 in 3~5 fractions. Median follow up time was 469 days. Results: The median GTV was 22.9 mL (range, 0.7 to 108.7 mL) and median PTV1 was 65.4 mL (range, 5.3 to 184.8 mL). The response rate at 3 months was complete response (CR) in 14 lesions, partial response (PR) in 11 lesions, and stable disease (SD) in 3 lesions, whereas the response rate at the time of the last follow up was CR in 13 lesions, PR in 9 lesions, SD in 2 lesions, and progressive disease (PD) in 4 lesions. Of the 10 patients in stage 1, one patient died due to pneumonia, and local failure was identified in one patient. Of the 10 patients in stages III-IV, three patients died, local and loco-regional failure was identified in one patient, and regional failure in 2 patients. Total local control rate was 85.8% (4/28). Local recurrence was recorded in three out of the eight lesions that received below biologically equivalent dose 100 $Gy_{10}$. Among 20 lesions that received above 100 $Gy_{10}$, only one lesion failed locally. There was a higher recurrence rate in patients with centrally located tumors and T2 or above staged tumors. Conclusion: SBRT using a CyberKnife was proven to be an effective treatment modality for early stage patients with NSCLC based on high local control rate without severe complications. SBRT above total 100 $Gy_{10}$ for peripheral T1 stage patients with NSCLC is recommended.

Image-Guided Radiotherapy for Target Localization in Prostate Cancer with Implanted Markers

  • Suh, Ye-Lin;Park, Sung-Ho;Ahn, Seung-Do;Kim, Jong-Hoon;Lee, Sang-Wook;Shin, Seong-Soo;Choi, Eun-Kyung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.68-70
    • /
    • 2005
  • To precisely localize target in prostate cancer, image-guided radiotherapy was performed using the $ExacTrac^{\circledR}$ x-ray system (Brainlab, Germany) with implanted markers. For three prostate cancer patients, three gold markers were implanted into prostate. Orthogonal portal images were acquired every treatment and CT scans were repeated 3~5 times during the course of treatment. After correcting setup errors calculated by the system, the position of the implanted markers and the distance between them were detected in daily portal images and in CT images, and analyzed retrospectively. Deviation of the relative position of the implanted markers and the distance between them were less than 1 mm in lateral, longitudinal, and vertical direction for three patients, both in portal images and CT images. This study reveals that image-guided radiotherapy using the $ExacTrac^{\circledR}$ system is useful to verify positioning errors and localize prostate target with implanted markers, reducing the planning target volume (PTV) margin as well as irradiation to rectum and bladder.

  • PDF