• 제목/요약/키워드: X-ray Imaging Apparatus

검색결과 11건 처리시간 0.03초

X-선 투과검사를 이용한 저항 점용접부 품질평가기법 (Weld Quality Evaluation Method for the Resistance Spot Welds using X-ray Transmission Inspection)

  • 이종대;이소정;방정환;윤길상;김목순;김준기
    • Journal of Welding and Joining
    • /
    • 제32권6호
    • /
    • pp.1-7
    • /
    • 2014
  • For the resistance spot welds of CR1180 and GA1180 TRIP steels, the weld quality evaluation method using the digitalized X-ray transmission imaging apparatus was investigated in comparison with the crosssectional examination method. In the case of the resistance spot welding of CR1180, three circular regions, such as WZ(white zone), GZ(grey zone) and DZ(dark zone), appeared on X-ray image and they corresponded to the diameters of indentation mark, nugget and corona bond, respectively. The variation of X-ray transmission thickness due to the thickness variation of the weld seemed to be mainly responsible for the formation of those contrasts. The X-ray image contrast formed from the variation of transmission thickness at the outer border line of DZ could also enable the inspections of the notch shape, nonuniformity of the welding pressure and spatter from its sharpness, concentricity and the normal straight line, respectively. The X-ray image of the resistance spot weld of galvannealed GA1180 TRIP steel was very similar to that of CR1180 TRIP steel except the crown shaped outer border line of DZ which was considered to be due to the melting behavior of zinc having the boiling temperature even lower than the melting temperature of steel.

가열장치를 구비한 부착형 탄소발열체 X선 촬영대 고안 (Design for Adhesive Carbon Heating Element X-ray Table with an Attached Heating Device)

  • 송종남;김응곤
    • 한국방사선학회논문지
    • /
    • 제9권3호
    • /
    • pp.131-137
    • /
    • 2015
  • 본 연구의 목적은 기존에 사용 중인 X선 발생장치의 촬영대를 따뜻하게 가열하면서도 X선 감약이 적은 탄소나노튜브(carbon nano tube, CNT) 발열체를 사용하여 가열장치를 구비한 X선 발생장치용 부착형 촬영대의 고안 및 설계를 하고자 한다. 고안된 제품의 구성은 부착형 탄소발열체 촬영대로서 기존 X선 촬영대, 탄소나노튜브 면상발열체, 전극선, 난연 처방된 보호필름과 바닥필름으로 구성되어 있다. 본 고안 제품의 특징과 장점은 냉기(冷氣)를 느끼는 촬영대에서 환의를 착용하고 검사를 받는 환자에게 온화한 느낌과 안전감을 제공하고 심적인 불안감을 해소하여 검사에 도움을 줄 수 있기 때문에 임상 적용을 적극 권장하는 바이다.

이동형 방사선 발생장치 차폐물 설치에 관한 연구 (A study on Protector Performance Evaluation According to X-ray Scattering Distribution of Portable Radiation System)

  • 김형균;성동근;조경미;김상범;김재영;최준호
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.85-92
    • /
    • 2009
  • This study, "The study about performance evaluations of mobile cover for X-ray's diffusion and distribution in mobile radiation" is based on the rules of mobile defense apparatus for radiation producer in 2006. To use the mobile cover for X-ray for diagnosis has been compulsory in common wards except operation rooms, emergency rooms and intensive care units. we have confirmed the effect in arbitrary shielding material after Qualitiy Control was carried out for accuracy in an experiment of mobile photographing equipment. The performance evaluation was conducted with the fabrics of selenium, 0.2 mmPb, 0.1 mmPb and aluminiums. Considering the result, we choosed 0.1 mmPb and attached cover to mobile photographing equipment. We have finished making the cover after drew up the draft to attach cover to mobile photographing equipment through the modeling and the structural analysis. the process of the study is that we assembled the manufactured structures and carried out the practical experiment to take the photograph after attaching the fabric of 0.1 mmPb to mobile photographing equipment. It is need of additional thesises hereafter that we compare the result between the part to improve for safety besides convenience in photographic experiment about clinical radiation and the effect of covering the diffusion in condition attached the cover.

  • PDF

ALVIM Phantom을 이용한 화질관리 (Image Quality Management Using ALVIM Phantom)

  • 임득춘;동경래;박용순;김창복;류영환
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.63-68
    • /
    • 2009
  • Among various physical or subjective assessments of the quality of X-ray images, physical assessments can be quantitative but they are eventually judged by the view of observers thus subjective assessments including the aspect of observers are required. The changes in the ability to detect lesions caused by changes in the thickness of acrylic plates were tested with the ROC interpretation method that has taken into consideration, all the features of physical assessments as well as observers' ability to observe and mental stages and even surrounding environments using an Alvim phantom and the result indicated that as the thickness of acrylic plates increased, the amount of noises occurred increased compared to signals and thus the ability to detect signals as well as the sensitivity that is an ability to signals accurately and the ability to distinguish noises from signals thus it is considered that more efforts of radiologic technologists will be required to detect small lesions of fat patients with diagnostic X-ray generating apparatus.

  • PDF

이동형 방사선 차폐장치의 성능평가에 관한 연구 (A Study on the Performance Evaluation of Portable Radiation Shielding Apparatus)

  • 구본열;한상현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권4호
    • /
    • pp.289-295
    • /
    • 2018
  • When using a mobile X-ray unit, primary radiation creates medical images and secondary radiation scatters in many directions, which reduces image quality and causes exposure to patients, care givers and medical personnel. The purpose of this study was to develop a radiation shielding system for effectively shielding secondary radiation and evaluate its effectiveness. Using a mobile X-ray unit, spatial dose according to presence of human equivalent phantom and spatial dose using the developed shielding device were measured, and the phantom at 80 cm equidistance from center of X-ray was compared with spatial dose according to use of a shield. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from the head direction($-90^{\circ}$) to the body direction($+90^{\circ}$). In the spatial dose measurement with and without the phantom, when the human equivalent Phantom was used, the spatial dose was increased by 40% in all directions from 40 cm to 100 cm from the central X-ray, and about 88% of the space dose was reduced when using the developed shields with the phantom. The equidistance dose at 80 cm from the central X-ray was increased by 39% from $5.1{\pm}0.26{\mu}Gy$ to $7.1{\pm}0.15{\mu}Gy$ when the human equivalent phantom was used, and when phantom was used and shielding was used, the spatial dose was reduced by about 90% from $7.1{\pm}0.15{\mu}Gy$ to $0.7{\pm}0.07{\mu}Gy$. The spatial dose of natural radiation was measured to be about $0.2{\pm}0.04{\mu}Gy$ when using the developed shielding with Phantom at a distance of 1 m or more. It is expected that by using the developed shielding system, it will be possible to effectively reduce secondary radiation dose received in all directions and to ensure safe imaging.

응급실 침대 위 흉부전후방향 엑스선 검사를 위한 상의고정장치 개발 (Development of the Upper Wear Fixation Device for Chest AP X-ray Imaging on the Emergency Stretcher Bed)

  • 임우택;홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권3호
    • /
    • pp.205-211
    • /
    • 2022
  • This study aimed to provide basic data for 3D printing in the medical health field by developing upper wear fixation device (UWFD), an auxiliary device for shortening chest AP examination time on emergency room beds and non-contact with patients. The standard of hooks was modeled according to the bed frame using the Autodesk Fusion 360. It was printed with Form2 (Formlabs, Somerville, MA, USA), as SLA (stereo lithography apparatus) method, and was washed and hardened using Form Wash and Form Cure. The completed UWFD conducted an online survey on 4 items of stability, convenience, availability, preference and general characteristics. The total stability average was 3.93±0.80, the total convenience average was 3.93±0.68, the total availability average was 4.01±0.89, and the total preference average was 3.80±1.08. This study was significant in suggesting improvements in the general X-ray examination process in the emergency room by designing and making aids to easily fixing the patient's top to the frame of the emergency bed while meeting promptness and non-contact with the patient.

모래 입자의 형상과 내부마찰각의 상관관계에 관한 연구 (Shear Resistance of Sandy Soils Depending on Particle Shape)

  • 서형석;조유민;윤태섭;김광염
    • 한국지반공학회논문집
    • /
    • 제32권6호
    • /
    • pp.41-48
    • /
    • 2016
  • 본 연구에서는 영상처리 기법을 이용해 총 9개의 모래 시료의 형상을 정량화하여 전단강도와의 상관관계를 분석하였다. 분석 시료는 6개의 자연모래 시료와 3개의 부순모래 시료이며 이를 고해상도 3차원 X-ray CT 촬영하여 그로부터 개별 입자 영상을 분리하고 구형도(Sphericity) 및 이완도(Elongation)와 같은 형상 계수를 통해 모래 시편의 형상을 정량화 하였다. 또한 시료의 상대밀도를 다르게 조성하여 직접전단시험을 수행해 첨두내부마찰각(Peak friction angle)과 극한내부마찰각(Critical state friction angle)을 획득하였다. 시료의 구형도가 감소하고 이완도가 증가할수록, 첨두내부마찰각과 극한내부마찰각은 유사한 기울기를 보이며 증가함을 확인하였으며 두 내부마찰각 사이 절댓값 차이는 입자 형상보다는 상대밀도 차이로부터 기인함을 확인하였다.

디지털 방사선 촬영술을 이용한 치근 흡수 판독에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE TOOTH ROOT RESORPTION FOR DIGITAL RADIOGRAPHY)

  • 오필교;김재덕
    • 치과방사선
    • /
    • 제25권2호
    • /
    • pp.375-387
    • /
    • 1995
  • The purpose of this study was to quantitatively evaluated experimental tooth root resorption for digital radiography. For this study, experimentally three root sites were used, and radiograms were taken with standardized apparatus. Digital imaging system were consisted of NEC PC-980l(computer), TRINITRON(monitor), SONY XC-711 CCD camera. The display monitor had a resolution of 512X512 pixels. The obtained results were as follows: 1. In the difference of the four X-ray film of the contrast correction, the contrast difference was one gray scale variation at mean value. 2. Viewing of the view box of the periapical radiographs, experimental tooth root resorption of the periapical area of the first premolar, middle of mesial surface of the first molar mesial root, middle of lingual surface of the first molar distal root were recognized by increased diameter. 3. On the analysis by histogram, the periapical area of the first premolar, the middle of mesial surface of the first molar mesial root were each recognized tooth root resorption of the 5,6,7 pixel, 2,4,5 pixel by increased diameter. 4. On the analysis by histogram, the middle of lingual surface of the first molar distal root was each recognized tooth root resorption of the none, 3,6 pixel by increased diameter.

  • PDF

Cone beam형 전산화단층영상을 이용한 영구치 치근과 근관의 형태 평가 (Evaluation of imaging reformation for root and pulp canal shapes of permanent teeth using a cone beam computed tomography)

  • 홍종현;김규태;최용석;황의환
    • Imaging Science in Dentistry
    • /
    • 제37권3호
    • /
    • pp.165-170
    • /
    • 2007
  • Purpose: To estimate the shape of root and pulp canal using a dental cone beam computed tomography (CBCT) and to evaluate the accuracy of imaging reformation. Materials and Methods: CBCT images were obtained with incisors, premolars, and molars as the destination by using PSR $9000N^{TM}$ Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) and i-CAT (Imaging Sciences International, Inc, USA) cone beam CT unit that have different kind of detector and field of view, and compared these with the shape and the size of actual root and root canal. Results: When the measuring value of cone beam computed tomography concerning to each root's bucco-lingual diameter and mesio-distal diameter was compared with the value of the actual root, it reveals an error range $-0.49{\sim}+0.63$ mm at PSR900N and $-0.97{\sim}+1.14$ mm at i-CAT (P>0.05). It was possible to identify and measure PSR$9000N^{TM}$ Dental CT system to the limit $0.48{\pm}0.06mm$ (P>0.05) and i-CAT CBCT to the limit $0.86{\pm}0.09mm$ (P<0.05) on estimating the size and the shape of root canal. Two kinds of CBCT images revealed the useful reproducibility to estimate the shape of root, but there was the difference to estimate the shape of root according to apparatus. The reproducibility of root shape in the image of three-dimensions at PSR 900N is low such as 0.65 mm in a case of minute root canal. Conclusions: CBCT images revealed higher accuracy of the imaging reformation for root and pulp and clinically CBCT is a useful diagnostic tool for the assessment of root and canal. However, there are different qualities of imaging reformation according to CBCT apparatus and limitation of reproducibility for minute root canals.

  • PDF

방사선 검출기 적용을 위한 액정 기반 다층 구조의 광 특성 평가 (The optical characteristics study of sandwich structure based liquid crystal for the radiation detector application)

  • 신정욱;강상식;박지군;조성호;차병열;김진영;이건환;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.390-392
    • /
    • 2005
  • The digital radiation detectors are used clinically by diagnostic apparatus. However the digital radiation detector are some problem like high operating voltage, light blurring, low conversion efficiency, low fill factor, etc. Thus we propose a new radiation detector that the photoconductor layer and liquid crystal layer are coupled in sandwich structure. X-ray absorption in the photoconductor layer controls the state of the liquid crystal via creation of charge carrier and the light modulation of liquid crystal make image formation. The advantage of the new radiation detector is that high resolution image is acquired and the signal amplification is possible by external visible light source. In this study, we study the optical properties and electrical properties of the new radiation detector to irradiate X-ray. The Mercury Iodide($HgI_2$) was used by photoconductor material, and the aluminum is used by reflective layer. The thickness of Mercury Iodide is about $200{\mu}m$, the operating voltage of the liquid crystal is 1.5~5V. The electrical properties of Mercury Iodide was measured, and the transmission efficiency of liquid crystal was measured by modulation potential.

  • PDF