• 제목/요약/키워드: X-ray Exam

검색결과 31건 처리시간 0.023초

일반엑스선영상검사의 인자에 따른 산란방사선량 평가 및 분석 (Evaluation and Analysis of Scattered Radiation Dose according to Factors in General X-ray Examination)

  • 정동경;박명환;서정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권1호
    • /
    • pp.13-19
    • /
    • 2024
  • Control of scattered radiation is one of very important factors in the use of medical radiation. In general X-ray exam, the causes, measurement methods, and the kind of detectors of scattered rays within the radiation area are diverse. In this study, the dose of scattered ray was measured by changing the thickness of the polycarbonate phantom and the tube voltage. As a result of measurement of scattered radiation, the results show that the scattered dose significantly(p<.05) increased with growing of thickness of phantom in the tube voltage 40, 50 and 60 kVp(F(p)<.05, R2>64%). As tube voltage increased at all phantom thicknesses, the scattered dose also significantly(p<.05) increased(F(p)<.05, R2>69%). In cases where a significant correlation was shown, the coefficient of determination of more than 60% was shown in regression analysis. The results of this study can be used as data on scattered radiation dose according to the tube voltage and the object thickness in general X-ray imaging exam.

X선진단(X線診斷) 부문(部門)에 있어서 업무량(業務量)에 관(關)한 조사연구(調査硏究)(II) (A Study on Activities of Diagnostic X-ray Examination(II))

  • 경광현;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제1권1호
    • /
    • pp.44-54
    • /
    • 1978
  • This study was carried out with statistical materials during the last two years of period from Jan. 1975 to Dec. 1976 which presented at radiologic department of 5 hospitals in Seoul City. The primary purpose of this study was to obtained more detailed informations related to the activities of radiologic technologists in diagnostic X-Ray examinations part and to provide some basic materials for managements in activities of then and manpower managements of their organization and practice. From the results of this study, the following conclusions were obtained [1] During two year from the January of 1975 to the December of 1976, total number of case in X-ray examinations were 464,830 case and 22,029 case in 1975 and 24,461 in 1976. And ratio of icreased in X-Ray examinations by year was 11.09 per cent. [2] Regarding the examined portion of X-Ray examination, a great propotion was chest examination as 56.88 per cent. [3] An average, the required time per case in X-Ray exam. was 9.28 minutes and make used of 1.94 sheets of X-Ray film per case in radiography. [4] An average, ratio of increased in X-Ray film by year was 12.71 per cent and ratio of failed film in it was 2.23 per cent. [5] The frequency rate of film size showed the highest distribution of $8"{\times}10"$(28.17%) and the highest distribution of X-Ray film by month was July(8.93%). [6] An average, the amount of activities per a diagnostic X-Ray equipment was 34.92 case and make used of 67.81 sheets of X-Ray film in a day. [7] The mean number of case in X-Ray examinations by radiologic technologists was 29.29 cases and make used of 56.87 sheets of X-Ray film in a day. Also, the average number of case was reading by radiologists was 32.42 case and 62.97 sheets of X-Ray film in a day.

  • PDF

두개골 측방향 X-선 촬영에서 정확도 향상을 위한 촬영 보조 기구의 유용성 평가 (Evaluation of Usefulness of Assertive Devices to Improve the Accuracy in Skull lateral X-ray Projection)

  • 장보석
    • 한국방사선학회논문지
    • /
    • 제18권2호
    • /
    • pp.153-159
    • /
    • 2024
  • 일반 X-선 촬영에서 경험이 없는 비숙련자의 경우, 검사 실패의 경험을 통해 숙련되는 과정을 겪는다. 이것은 불필요한 의료 피폭 가중의 문제를 유발한다. 본 연구에서는 배치 전 비숙련 방사선사가 임상 숙련도를 높일 수 있는 방안으로, 시각적, 공간적 보조 장치를 이용한 두개골 측방향 촬영 실습을 통해, 촬영 보조장치 사용에 따른 정확도와 유용성을 평가하였다. 육안적 관찰과 학습에 의존해서 촬영한 경우 영상 왜곡을 나타내는 회전 이격도 7.85 ± 1.45 mm, 기울임 이격도 4.84 ± 0.5 mm였다. 시각적 보조 장치를 이용해서 실습한 경우 회전 이격도 4.4 ± 0.76 mm, 기울임 이격도 3.01 ± 0.87mm였다. 공간적 보정 기구를 이용해서 실습한 경우 회전과 기울임 이격도는 5.2 ± 0.69 mm, 3.33 ± 0.61 mm로 나타났다. 배치 후 작업 환경과 동일한 조건에서 경험적 촬영 실습에 의한 영상 왜곡은 5.4% 감소하였으나, 기울임에 의한 영상 왜곡은 1.2% 증가하였다. 시각적 보조 장치를 이용해서 실습한 경우, 경험적 촬영 실습보다 회전이격도 40.1% 기울임 이격도 30.7% 감소하였다. 공간적 보정 기구를 사용할 경우, 기존의 경험적 실습 방식보다 회전 이격도 41.7%, 기울임 이격도 23.7% 감소하였다. 따라서 비숙련 방사선사의 배치 전 시각적, 공간적 촬영 보조 기구를 이용한 실습은 배치 후 검사 정확도 향상과 재촬영률 감소에 도움을 줄 수 있을 것으로 사료된다.

기관지내 발생한 폐과오종 - 1례 보고 - (Endobronchial Hamartoma - 1 case -)

  • 문석환
    • Journal of Chest Surgery
    • /
    • 제22권3호
    • /
    • pp.473-477
    • /
    • 1989
  • Pulmonary hamartoma has been considered as rare disease, which consists of lung tumor less than 1 %. Originally described by Albrecht in 1904, hamartoma is tumor like malformation-abnormal mixing of the normal components of organ-and is applied also to tumor found in many organs other than the lung. Lately, the major conclusions are that pulmonary hamartoma is neoplastic rather than developmental error in origin. Because pulmonary hamartoma frequently mimics lung cancer, especially in cancer-risk age groups, its clinical significance is great. Recently, we experienced 1 cases of endobronchial hamartoma which located at the right main stem bronchus. The patient was a 54 year old male who was admitted due to symptoms of fever 4 chilliness and dyspnea. Radiologic studies such as chest x-ray, chest tomogram and chest C-T scan revealed that the nearly total haziness of the right lung was caused by endobronchial tumor. The mass was considered as a benign by bronchoscopic exam, so we removed it surgically by tracheobronchotomy without pulmonary resection. Postoperative chest x-ray revealed satisfactory reexpansion of previous collapsed right lung. The patient discharged uneventfully.

  • PDF

유방촬영시 관찰조건에 따른 임상영상평가 (Evaluation of Clinical Image on Observational Condition in Mammography)

  • 김미현;김창복;지연상;동경래
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.89-95
    • /
    • 2010
  • High contrast and high resolution are the most important factors for examining mammography images. Despite of the inconveniences of screen-film, most clinics still prefer them to computed radiography(CR) and direct radiography(DR). The reading of screen-film mammography images is influenced by the brightness from the X-ray illuminator, the exam room and incoming light from outside sources. Therefore, a comparative analysis on the results of mammo phantom images would be variated by the changes in the reading environment. There was no influence on reading results from the examiners close distance eyesight(p > 0.05); however, reading of micro lesions improved with greater darkness in the X-ray film reading room and the brightness of the X-ray illuminator(p < 0.05). Also, observation of fiber and mass images were maximized at a distance of 50 cm from the reader. Now, it is possible to observe these small classification groups using a magnifying glass without being physically close to the image. For the image of mammography, obtaining high quality images is important but in order to get an accurate clinical lesions of the reading also needs to be considered the optimal environmental factors.

  • PDF

유방 미세석회화 조직검사에서 X선 유도 하 조직검사와 초음파 유도 하 조직검사의 유용성 (Usefulness of X-ray Guided Biopsy and Ultrasound Guided Biopsy in Breast Microcalcification Biopsy)

  • 최미선;송종남
    • 한국방사선학회논문지
    • /
    • 제10권3호
    • /
    • pp.201-206
    • /
    • 2016
  • 유방암에 관한 사회적인 관심이 증가되고 있는 가운데 진단의 가장 기본이 되는 검사는 유방 X선 촬영과 유방 초음파 검사이다. 특히 유방 미세석회화는 조직학적 진단을 필요로 하며 유방 미세석회화 조직검사를 시행하고 있다. 이에 미세석회화 진단에 기본이 되는 X선 유도 하 조직검사(needle localized open biopsy)와 초음파 유도 하 조직검사(sono guided core needle biopsy)를 분석하여 평가하고자 한다. 유방 미세석회화를 주소로 내원한 환자에서 확대 촬영을 시행한 241예를 대상으로 X선 유도 하 조직검사(needle localized open biopsy)와 초음파 유도 하 조직검사(sono guided core needle biopsy)의 연령대 별 분포와 병소의 위치를 분석하고 확대촬영 시행 후 이루어진 검사를 분류해서 X선 유도 하 조직검사와 초음파 유도 하 조직검사의 빈도를 분석하고 악성과 양성의 결과를 확인 하였다. 그 결과 X선 유도 하 조직검사(needle localized open biopsy)가 64예(26.6%)로 초음파 유도 하 조직검사(sono guided core needle biopsy) 12예(4.9%)에 비해 5.4배 높은 것으로 나타났다. 초음파 장비의 발달과 입체정위 흡입법(stereotactic vacuum-assisted biopsy)등의 발달로 미세석회화의 조직학적 진단방법이 다양해지고 있지만, 각각 검사의 특성과 한계점을 고려해 볼 때 X선 유도 하 조직검사(needle localized open biopsy)가 유방 미세석회화 병변에서는 정확한 조직학적 진단을 제공한다고 사료된다.

위 X선촬영 실태에 관한 조사 연구 (The Study on Actual Conditions done and the Image Quality of UGI)

  • 이선숙;허준;김성수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권1호
    • /
    • pp.39-42
    • /
    • 1997
  • This study was done at 45 medical facilities located in Seoul. The purpose of study is twofold. First, this is to investigate usually who extmines patients for UGI and how many films are used for the examination. Secondly, this is to evaluate image qualities of UGI in terms of representation of lesser curvatures, amount of Ba and air and other criteria for the exam. The results are as follows : 1. In most cases, the UGI is examined by the Dr(67%), by the RT(22%), and together(11%). 2. The total films used ranged from 5 sheets(42%) to 7 sheets(18%). 3. The amount of Ba given to Pt. was mostly $200{\sim}300\;ml$(60%) and gastrografin was used $3{\sim}4\;g$(86.6%) for the examination. 4. For the evaluation of qualities, lack of representation of lesser curvature was 86.7%, lack of Ba and air and bubble formation was 62%, 46.7% and 42.2% respectively.

  • PDF

폐과오종(肺過誤腫)의 일치험례(一治驗例) (A Case of Pulmonary Hamartoma)

  • 박광훈;지정희
    • Journal of Chest Surgery
    • /
    • 제9권2호
    • /
    • pp.169-174
    • /
    • 1976
  • Since. its first description by Albrecht in 1904 that hamartoma (Greek. meaning "error" and "tumor")is tumor-like malformation characterized by abnormal mixture of normal constituent in any organ it arises, hamartoma involving the lung has assumed the following clinical features.: 1) all the pulmonary lesions presenting as "coin lesions", it occupies about 8% according to various reports. It also constitutes the most prevalent lesion of all the benign lung tumors, appearing in 0.25% of the general population. 2) Peak incidence of the lesion occurs in the 5th and 6th decade as the carcinoma patient do, and the occasional growing tendency and periperal location as in this presentation renders the differential diagnosis from the malignant disease difficult and surgical intervention inevitable for definite histological diagnosis and treatment. 3) Nearly all the clinical investigations such as history, physical exam, bronchoscopy, culture, and cytological exam of sputum sre likely to futile:the only tool for detecting the presence of the lesion is X-ray, butthat's short of telling the true nature of it. 4) Because of its age of presentation and growing tendency in middle-aged adult, it still controversial whether it is developmental anomaly as Albrecht described, or true neoplasm denovo of fibrous connective tissue origin. This is a case report of surgical experience of pulmonary hamartoma which had nearly all the typical clinical features above mentioned and was reviewed with related literatures.

  • PDF

의료영상 진단을 위한 팔꿉관절 X-선 검사 보조기구 개발 (Development of Elbow Joint X-ray Examination Aid for Medical Imaging Diagnosis)

  • 김형균
    • 한국방사선학회논문지
    • /
    • 제18권2호
    • /
    • pp.127-133
    • /
    • 2024
  • 팔꿉관절은 3개의 뼈대가 조합하여 관절을 이루고 있으며 신체적 활동 및 외력에 의한 이상 시 X-선 등, 방사선 검사로 영상진단을 한다. 팔꿉 관절 선행연구에 의하면 전완부(forearm)의 Z축 거상에 의한 기울기 자세에서 영상평가 기준에 부합하는 새로운 검사법이 발표되어 이에 최적화된 기구를 설계하고 다른 상지 검사에서도 활용 가능한 보조기구를 개발하고자 하였다. 2D 도면 및 3D 모델링 설계로 디자인 후 4부분의 파트로 구분 된 디자인을 ABS 소재의 3D 프린팅 방법으로 출력 후 조립 단계를 거쳐 제품을 완성하였다. 개발된 보조기구는 Z축 거상 기울기 4단계 각도(0, 5, 10, 15도) 기능과 1도 단위로 360도 회전되어 고정하는 기능으로 구성하였다. 개발된 보조기구는 사용 빈도의 누적 및 신체적 활용에 의한 하중 문제에 대해 구조해석을 통하여 최대 등가응력(equivalent stress) 56.107 Pa, 변위(displacement) 1.6548e-5 mm 의 안전한 물성치 범위로 개발되었다. 또한 개발된 보조기구는 팔꿉관절의 X-선 검사뿐만 아니라 위팔뼈 회전에 의한 어깨 기능검사에서도 활용할 수 있으며 비금속 소재로 MRI, CT 검사에서도 적용이 가능하도록 개발되었다. 개발된 보조기구는 향후 다양한 장치 및 의료영상 검사의 임상 적용을 통하여 검사의 정확성 및 효율화에 기여하리라 판단한다.

국가건강검진의 방사선검사 이용량 및 피폭선량 추정 (Estimated Exposure Dose and Usage of Radiological Examination of the National Health Screening)

  • 길종원;박종혁;박민희;박찬영;김소영;신동욱;김원동
    • Journal of Radiation Protection and Research
    • /
    • 제39권3호
    • /
    • pp.142-149
    • /
    • 2014
  • 한국은 국가건강검진을 시행하여 국민건강증진에 크게 기여하고 있으며 그 수검률 또한 증가하고 있다. 본 연구는 수검률 증가에 따른 방사선검사의 증가가 예상되어 그 이용 빈도(이용량)와 피폭선량을 파악하고자 한다. 본 연구는 2011년 국민건강보험공단 건강검진 분석 자료에서 방사선검사를 분리하여 이용량을 파악하고, UNSCEAR 2008년 보고서의 수록되어 있는 검사별 선량을 적용하여 국가건강검진에서 방사선검사로 인한 피폭선량을 추정한다. 주요 분석결과 2011년 국가건강검진 수검자 1인당 평균 피폭선량은 0.57 mSv로 추정되었고, 최대 11.081 mSv, 최소 0.02 mSv로 추정되었다. 방사선검사의 이용 빈도와 피폭선량은 각각 총 16,005,914건, 6,311.76 person-Sv로, 이중 이용량은 흉부 X선검사가 1,070,569 (69.17%)건으로 가장 높았고, 피폭선량은 위장조영검사가 5,217.94 (82.67%) person-Sv로 가장 높았다. 성 연령별 결과 39세 이하를 제외한 전 연령대에서 여성의 수검비율과 피폭선량이 높았고, 특히 50-54세 여성이 1,674,787 (10.5%)건, 701.59 (11.1%) person-Sv로 가장 높았다. 검사별 선량에서 위장조영검사가 전체 82.67%를 차지하는 만큼 의료상(목적) 반드시 시행하는 경우를 제외하고는 위장내시경검사를 선택하여 수검 받도록 정책적으로 장려하고 외국의 사례와 같이 경제성과 실효성 평가에 따라 폐지된다면 국가건강검진에의 방사선피폭은 현저히 줄어들 것으로 예상한다.